HomeMy WebLinkAboutOrdinance 2857 ORDINANCE N0. AN ORDINANCE AMENDING PARAGRAPH 11-1-5 OF SECTION 11-1 OF CHAPTER 11 OF ORDINANCE NO. 1389, -WHICH IS A PARAGRAPH OF THE BUILDING CODE OF THE CITY OF FORT WORTH, THE SAME BEING AN ORDINANCE COVERING AND REGULATING THE CONSTRUCTION, ERECTION., ALTERATIONS ETC., OF THE BUILDINGS AMID STRUCTURES IN FORT WORTH AND PROVIDING FOR THEIR SAFETY' BY CHANGING CERTAIN PROVISIONS THEREOF WITH REFERENCE TO FIREPROOFING MATERIALS USED IN BUILDINGS AND OTHER STRUCTURES; DECLARING THE ORDINANCE TO BE CUMULATIVE; AND PROVIDING AN EFFECTIVE DATE. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF FORT WORTHY TEXAS SECTION 1• That Paragraph 11-1-5 of Section 11-1 of Chapter 11 of Ordinance No. 1389 be amended to read as follows: Chapter 11. FIRE PROTECTION Section 11-1. FIREPROOFING STRUCTURAL NUMBERS. Paragraph 11-1-5. Fireproofing Materials. In buildings of First-Class and Second-Class "A" Construction, every metal structural member which supports. loads or resists stresses shall be fireproofed to have a fire resistance rating as follows: Beams and girders supporting columns, masonry or reinforced concrete halls shall have a fire resistance rating of not less than four (4) hours. Other beams and girders shall have a fire resistance rating of not less than three (3) hours. Beams and girders shall be individually protected in a manner to give the required fire resistance rating; except that beams may be protected by a fire resisting ceil- ing of such construction that the fire resistance rating of the floor and ceiling assembly, or roof and ceiling assembly will be not less than three (3) hours, provided the space above the ceiling is fire-stopped with noncombustible material to form areas of not more than 2000 square feet. Trusses supporting columns or masonry or reinforced concrete walls shall be individually protected by noncombus- tible construction having a fire resistance rating of not less than four (4) hours. Other trusses shall be protected by construction having a fire resistance rating of not less than three (3) hours; except that trusses which support only roof loads and ceilings over floor areas having a clear height not less than twenty-five (25) feet below the lower chords of the truss may be protected by a ceiling of noncom- bustible construction having a fire resistance rating of not less than one (1) hour. Columns shall have a fire resistance rating of not less than four (4) hours, and all spaces between the required fireproofing and the member protected shall be fire-stopped at each floor level. Where fireproofing of columns is exposed to damage from trucking or handling of merchandise, it shall be jacketed for a height of five (51 feet from the floor with a substantial cover or provided with wheel guards. The floor and roof construction shall have a fire resistance rating of not less than three (3) hours. Floor and roof slab in reinforced concrete construction, other than slab supported on joists, shall be at least four (4) inches thick. Every metal structural member which supports loads or resists stresses in that portion of the building which is below the street or ground grade floor construction shall be protected by encasing completely with a poured in place fire- proofing material of a durable quality equal to concrete having coarse aggregate limestone or calcareous gravel to provide a fire resistance rating of four (4) hours. This type of fire- proofing shall also be used in damp places where metal may be subjected to rapid deterioration, and on columns on street or ground floor of Type 3 (Business buildings). 'Where a ceiling is used to fire protect supporting structural members of a floor or roof construction, such ceiling shall be continuous, but may have openings for non- combustible pipe ducts and electrical outlets, provided that the areas of such ducts and outlets opening through the ceil- ing aggregate not more than 100 square inches per 100 square feet of ceiling area. The ceiling shall be made continuous around recessed lighting fixtures, and openings for large heat- ing, cooling or ventilating ducts shall be protected by fire shutters operated with fuseable links. The fire resistance rating of various fireproofing materials and constructions shall be the same as the rating established by standard fire tests conducted in accord with the "Standard Methods of Fire Tests of Building Construction and Materials," ASTM E119-47 and listed in Appendix "A," 1949 edi- tion of the "National Building Code," promulgated by the National Board of Fire Underwriters, or as established by fire resistance reports, Nos. R-3187-1. R-3187-3, !R-2993, R-29942 R-2993 (supplement), R-2851 and 8-2773, of Underwriters Labora- tories, Inc. SECTION 2. This ordinance shall be and is hereby declared to be cumulative of all other ordinances of the City of Fort Worth affecting the construc- tion, erection, remodeling and rebuilding and inspection of buildings and structures in Fort Worth, and providing for their safety, and shall not operate to repeal or affect any such ordinance or ordinances except insofar as they are in conflict or inconsistent with the provisions of this ordinance. SECTION 3. This ordinance shall take effect and be in full force and effect from and after the date of its passage and publication as provided by la , APPROVED AS TO FORM: ss's ant City Attorney