Loading...
HomeMy WebLinkAboutOrdinance 3569 ORDINANCE NO. AN ORDINANCE AMENDING ORDINANCE NO. 2978, THE PLUMB- ING CODE, BY MAKING A PROVISION FOR THE INSTALLATION OF TERAZZO SHOWER BATHS, PROVIDING THAT THIS ORDINANCE SHALL BE CUMULATIVE OF ALL ORDINANCES AND PROVIDING AN EFFECTIVE DATE. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF FORT WORTH, TEXAS: SECTION 1. That Paragraph 12-3 of Ordinance No. 2978, being the Plumbing Code of the City of Fort Worth, be amended and as amended shall hereafter read as follows: Paragraph 12-3. SHOWER BATH AND TRAP. Each shower bath shall be provided with trap of Cast Iron, Brass or lead with water seal of not less than 2" or more than 4". Inlet and outlet of this trap shall not be less than 2" in diameter. Showers installed in- dependent of shower heads over bath tubs shall be wasted through a double drainage floor drain appliance as made by the various manufacturers, and approved by the Plumb- ing Inspector. Drilling of the brass strainer will not be permitted. Waste shall connect with either vertical stack or horizontal house drain independent of all other fixtures, and in no case shall be connected to lead bend or lead ferrule serving water closets. When 2" P-Traps are used under showers in order to keep from cutting the floor joist, the extension from trap to strainer shall be of cast iron or brass and the distance from floor line to trap shall not exceed 24, and the dis- tance from water seal to point of entrance on vertical or horizontal connection on continuous waste shall not exceed 51. Beyond this limit, traps shall be revented. Wherever built-up shower baths are installed except those constructed on concrete slabs directly on the earth the base may be precast terazzo receptor with flange cast integral and shall be of galvanized-bonder- ized steel and shall extend not less than one inch above the shoulder. The shoulder shall be not less than one inch high and not less than one-and-one-quarter inches wide or the base of the shower stalls shall be lined with sheet lead weighing not less than four pounds to the square foot. Lead shower pans shall be protected on both upper and lower sides by coating with asphalt and application of 30 pound asphalt felt over such coating on both sides of pan. The sheet lead shall be turned up on all sides to a height of not less than b". Base and walls of shower stall shall be of non-absorbent materials and impervious to moisture. When shower baths are installed in manufacturing establishments, shop and engine or boiler rooms in basements or if the floor in such places are con- structed on the ground using concrete or tile, then the double drainage fixture and lead pan need not be used. Cast iron combination "P" trap with strainer may be used with wastes and vents in such business establishments. Prefabricated shower stalls with metal walls and enameled metal, stainless steel or terrazo receptor may be installed on the ground floor of residential buildings only. Said stalls installed in residential buildings above the ground floor shall have terrazo receptors. Shower walls and receptor shall be con- nected with water tight joints in such installation. SECTION 2. This ordinance shall be cumulative of all the ordinances of the City of Fort Worth, and in the event that any other ordinance shall be in conflict herewith, the terms and provisions of this ordinance shall be controlling. SECTION J. This ordinance shall be effective from and after its passage and pub- lication as provided by law. APPROVED AS TO FORM: 1 Assistant City Attorney ORDINANCE No. �� f. Title ;� :<!��'� S-'�A:��Jl//Y-Y)t."� �"""y �/I'Lam .!/`�✓"C.�wV Adopted Final Adoption ` Published• ; !ys`T . �v. /- ,'9� ' File&_ Day of t v im ' , 19 'City Secretary P P. O.No.42978-U