HomeMy WebLinkAboutContract 44534 (2)Tariff for Retail Delivery Service
Oncor Electric Delivery LLC
`". i
� _ ,� - _ _
6.3 Agreements and Forms
Applicable: Entire Certified Service Area Page 1 of 3
Effective Date: January 1, 2002 010407 Revision: Original
6.3.4 Discretionary Service Agreement
WR 3180324
th J'uNF zo� s,
This Discretionary Service Agreement ("Agreement") is made and entered into this �_day of
by Oncor Electrlc Dellvery Company LLC ("Oncor Electric Delivery' or "Company"), a Delaware limited liability
company, under the Delaware Limited Liability Company Act, and a distribulion utility, and the City of Fort Worth
("Customer'), a municipality, each hereinafter sometimes referred to individually as "Party" or both referred to coilectively
as the "Parties". In consideration of the mutual covenants set forth herein, the Parties agree as follows:
1. Discretlonary Services to be Provlded — Company agrees to provide, and Customer agrees to pay for the following
discretionary services in accordance with this Agreement:
Per a request from the City of Fort Worth, Oncor Electric Delivery LLC (OED) relocated and/or removed electric
distribution facilities for the proposed construction of the White Settlement Street Bridge in the Trinity River Vision
Development. It is proposed to install 2580 ft of 3-795 AAC 7.2/12.5 KV primary conductors in a double circuit
configuration with an existing distribution feeder circuit, 310 ft of 3-795 AAC 7.2/12.5 KV primary w/ #2 AAAC neutral,
620 ft of #2 AAAC 7.2/12.5 KV primary w/ #2 AAAC neutral, 250 ft of 2-#2 AAAC 7.2/12.5 primary conductors, 75 ft of
#2/0 AL quad secondary cable, 135 ft of #2 AL triplex secondary cable, 270 ft of 3-1000 AL 7.2/12.5 KV URD primary
cables in a 6" conduit, 50 ft of 3-1/0 AL 7.2/12.5 KV URD primary cables in a 4" conduit; reconductor 715 ft of #2 ACSR
7.2/12.5 KV primary conductors with 3- 795 AAC 7.2l12.5 KV primary conductors; remove 3100 ft of 3-#795 AAC
7.2/12.5 KV prfmary conductors, 1770 ft of 3-336 ACSR 7.2/12.5 KV primary, 100 ft of 3-#4 ACSR 7.2/12.5 primary
conductors, 440 ft of various size secondary cables,.
This pro)ect will be woriced on Oncor Electric Delivery WR# 3180324.
2. Nature of Service and Company's Retail Delivery Service Tariff — Any discretionary services covered by this
Agreement will be provided by Company, and accepted by Customer, in accordance with applicable Public Utility
Commission of Texas ("PUCT") Substantive Rules and Company's Tariff for Retail Delivery Service (including the Service
Regulations contained therein), as it may from time to time be fixed and approved by the PUCT ("Company's Retail
Delivery Tariff ). During the term of this Agreement, Company is entitled to discontinue service, interrupt service, or refuse
service initiation requests under this Agreement in accordance with applicable PUCT Substantive Rules and Company's
Retail Delivery Tariff. Company's Retail Delivery Tariff is part of this Agreement to the same extent as if fully set out
herein. Unless otherwise expressly stated in this Agreement, the terms used herein have the meanings ascribed thereto in
Company's Retail Delivery Tariff.
3. Discretfonary 5ervice Charges -- Charges for any discretionary services covered by this Agreement are determined
in accordance with Company's Retail Delivery Tariff. Company and Customer agree to comply with PUCT or court orders
concerning discretionary service charges.
4.Term and Termination — This Agreement becomes effective upon acceptanCe by both the Company and the Customer
and continues in effect until all associated work by Oncor Electric Delivery LLC is complete and reimbursements are
secured, with no allowances for betterment. Terminetion of this Agreement does not relieve Company or Customer of any
obligation accrued or accruing prior to termination.
5. No Other Obllgations -- This Agreement does not obligate Company to provide, or entitle Customer to receive, any
service not expressly provided for herein. Customer is responsible for making the arrangements necessaty for it to
receive any further services that it may desire from Company or any third party.
6.Governing Law and Regulatory Authority -- This Agreement was executed in the State of Texas and must in all
respects be governed by, interpreted, construed, and enforced in accordance with the laws thereof. This Agreement is
subject to all valid, applicable federal, state, and local laws, ordinances, and rules and regulations of duly constituted
regulatory authorities having jurisdiction.
7. Amendment --Thls Agreement may be
not be effective until reduced to writing an
and Company's Retail Delivery Tariff are
amendment of this Agreement.
amended only upon mutual agreement of the Parties, which amendment will
d executed by the Parties. Bui changes to applicable PUCT Substantive Rules
applicable to this Agreement upon their effective date and do not require an
R�CEIV�L� ��1� 11 ��i3
Tariff for Retail Delivery Service
Oncor Electric Delivery LLC
6.3 Agreements and Forms
icable: Entire Certified Service Area
Page 2 of 3
010407 Revision: Original
8. Entirety of Agreement and Prior Agreements Superseded — This Agreement, (ncluding all attached Exhibits, which
are expressly made a part hereof for all purposes, constitutes the en8re agreement and understandfng between the
Parties with regard to the service(s) expressly provided for in this Agreement. The Parties are not bound by or liable for
any statement, representation, promise, inducement, understanding, or undertaking of any kind or nature (whether written
or oraij with regerd to the subject matter hereof not set forth or provided for herein. it is expressly acknowledged that the
Parties may have other agreements covering other services not expressiy provided for herein, which agreements are
unaffected by this Agreement.
9. Notices -- Notices given under this Agreement are deemed to have been duly delivered if hand delivered or sent by
United States certified mail, return receipt requested, postage prepaid, to:
(a) If to Company:
Oncor Electric Delivery LLC
Larry K. Baldwin
115 W. 7�h Street, Suite 625
Fort Worth, TX 76102
Office: 817-215-6184
(b) If to Customer:
City of Fort Worth
Mark Rauscher
Planning 8� DevelopmenUProgram Management Office
1000 Throckmorton Street, 2nd Floor
Fort Worth, TX 76102
The above-listed names, titles, and addresses of either Party may be changed by written notification to the other.
10. invoic(ng and Payment — Invoices for any discretionary services covered by this Agreement will be mailed by
Company to the following address (or such other address directed in writing by Customer), uniess Customer is capable of
receiving electronic invoicing from Company, in which case Company is entitled to transmit electronic invoices to
Customer.
City of Fort Worth
Mark Rauscher
Planning 8 DevelopmenUProgram Management Office
1000 Throckmorton Street, 2nd Floor
Fort Worth, TX 76102
If Company transmits electronic involces to Customer, Customer must make payment to Company by electronic funds
transfer. Electronic invoic(ng and payment by electronic funds transfer will be conducted in accordance with Company's
standard procedures. Company must rece(ve payment by the due date specifiiad on the invoice. If payment is not
received by the Company by the due date shown on the invoice, a late fee will be calcuiated and added to the unpaid
balance until the entire invoice is paid. The late fee will be 5% of the unpaid balance per fnvoice period.
11. No Waiver -- The failure of a Party to thfs Agreement to insist, on any occasfon, upon strict performance of any
provision of this Agreement wlll not be considered to waive the obligations, rights, or duties imposed upon the Parties.
12. Taxes -- Ail present or future federal, state, municipal, or other lawfui taxes applicabfe by reason of any service
performed by Company, or any compensation paid to Company, hereunder must be paid by Customer.
13. Headings -- The descriptive headings of the various articles and sections of this Agreement have been inserted for
convenience of reference only and are to be afforded no significance (n the interpretation or construction of this
Agreement.
14. Multipie Counterparts -- This Agreement may be executed in two or more counterparts, each of which is deemed an
originai but all constitute one and the same instrument.
Tariff for Retail Delivery Service
Oncor Electric Delivery LLC
6.3 Agreements and Forms
Applicable: Entire Certified Service Area Page 3 of 3
Effective Date: January 1, 2002 010407 Revision: Original
15. Other Terms and Conditlons —
(i) Customer agrees that payment shall be made within 60 days of the date the project is completed or the date
the invoice is received, whichever (s later. Project is deemed as complete for billing purposes upon removal of
Oncor's electric distribution facilities as fndicated on exhibit plans less the removal of poles where foreign
contacts encumber the removai of said poles. The estimated amount to be invoiced is 5415.181.78.
Customer has requested and will be billed for actual charges. A line item detail of actual charges will be
provided upon presentation of a final invoice.
(ii) Customer has disclosed to Company all underground facilities owned by Customer or any other party that is
not a public utility or governmental entity, that are located within real property owned by Customer. In the event
that Customer has failed to do so, or in the event of the existence of such facilities of which Customer has no
knowledge, Company, its agents and contractors, shall have no liability, of any nature whatsoever, to Customer,
or Customer's agents or assignees, for any actual or consequential damages resulting from damage to such
undisclosed or unknown facilities.
(iii) The Discretionary Service Charges provided in this agreement are for Oncor Electric Delivery facilities onlv
and do not include any charges related to the relocation of any facilities owned by a franchised utility,
governmental entity, or licensed service provider (Joint User). The customer must contact all Joint Users and
make arrangements to have their facilities transferred or relocated. Oncor Electric Delivery can not complete
the relocation/removal of facilities outline in this agreement until Joint Users(s) remove their facilities attached to
Oncor Electric Delivery poles.
(iv) Construction of this project wlll not begin untfl this signed document is returned to Oncor Electric Delivery
Company LLC at the above referenced address.
(v) The estimated cost provided for this agreement is good for 90 days. If this agreement has not been executed
by both parties by Auaust 23. 2073 or if Customer requests Company's performance of Discretionary Services
to begin after Auaust 23. 2013, Company reserves the right to void this Agreement and submit an updated
Discretionary Service Agreement with recalculated cost for lhe Discretionary Services to be provided
(vi) The discretionary services performed hereunder by Oncor Electric Delivery are a portfon of the relocation
obligations as set forth in Paragraph 1 of the Memorandum of Understanding Trinity River Vision Project dated
September 28w, 2012 by and between the City of Forth Worth and Oncor Electric Delivery.
IN WITNESS WHEREOF, the Parties have caused this Agreement to 6e sign by their respective duly authorized
representatives.
ONCOR LECTRIC DELIVERY COMPANY LLC
ey:
�
Name: �ftti►� ��N6/�t1f�5T
Title: �«. �Dt�f �✓�(Zii f�C�S � Q�,
CITY �L /��
gy: a
Name: �r/%�i%L��7 t,.�.fl� .
Title: � . C � ���� :r
Date: � ��
:�` � •�" " j : ,�,
�.
%i :�7 c ' �� � � ��ri�
3
-2a��z
ONC R
�
Electria Delivery LLC
ONCOR WR No.: 3180324
Descript[on: White Settlement Bridge
As of Date: 5129/2013
Estimate VOID Date: 8/29/2013
...� . :��.
. . . ,, • ,
�„ .. � •
.. . ,
: E.��hi�bit ''�." � Sc�pe of �hTork � � �
The City of Fort Worth has requested the relocation and/or removal of Oncor
Electric Distribution facili�ies for th� proposed improvements for the Trinity
River Vision Project along White Settlement Road.
It is proposed to insta.11 approxirnately 2580 feet of 3-?95 A.AC 7.2/ 12.5 KV
primary conductors in a double circuit conf guration with an exis�ing
distribution feeder circuit; 310 feet of 3-795 AAC 7.2/ 12.5 KV primary w/ #2
AAAC neutral; 62� feei of #2 AA.AC 7.2/ 12.5 KV prirnary w/ #2 AAAC neutral;
250 feet of 2-#2 AA.AC ?.2/ 12.5 KV primary conductors; 75 feet of #2/0 AL
quad secondary cable;� 135 feet of #2 AL trp secondary cable; 270 feet of 3-1000
AL 7.2 / 12.5 I£V primary UG cables in a 6" eonduit; 50 feet of 3� 1/ 0 AL
7.2 / 12.5 KV primary UG cables in a 4" conduit; reconductor 715 £eet of #2
ACSR 7.2/ 12.5 KV primary conductors with 3- 795 .AAC 7.2/ 12.5 KV primary
conduetors; remove 3100 feet of 3-#795 AAC ?.2 j 12.5 KV primary eonductors;
1770 feet of 3-336 ACSR 7.2/ I2.5 KV primary; 100 feet of 3-#4 ACSR 7.2/ 12.5
primary conductors, 440 feet of varzous size secondar� cables.
� C R
N
�
Electric Delirrery LLC
ONCOR WR No.:
Descrtptlon:
As of Dats:
Estlmate VOID Date:
3180324
White Settiement B�idge
5/29/2013
8/29t2013
�..� . '� �:
• ,s . ,
, �11.11���,� tt�ll _ ��.i.m�:�C�',� �'�Stl�.�.l.� . .
Labor 162,425.99
Materlals 113,411.16
Vouchers 34,000.00
subtotai: 309,837.15
lndirect Construction Overhead 106,344.63
subtotal: 415,181.78
�
Less Betterment
_�, . ;
0,00
0.00
415,181.78
V 1 �1t., �
�
Electric Delivery LLC
ONCOR WR No.:
Description:
As of Date:
Estimate VOID Date:
3180324
Whibe Settlemerrt Br(dge
5l29/2093
8l2812073
�•.. . •i �.
. . .. . : .
. � . �� E�hibiti "�'" -- : Lab�r iE�tim�.�e � � .
Estiamr�a � � ����a
Work Unit �. Descriptiori�� . � n� .�stimgted Cost
Brecket, Trenstormer Mounttng. includes: Asremble Bracket And
OH43�OR Mount Bracket Unitaf Maasure = Each. 1 ; 9.39 i 9.39
Bracket, 8tando}f (1 Ot 2 3ingle Phase, Or 1 Or 2 7tivo Phase},
Piberglass. lnciudes: Drlliing Pole, Bracket And Mounting Hardware.
OH4Q80R UnR Of Meaeure A Each. 2 S 18.31 5 32.62
Rack, Cable. tncludas: Hardware And Moun� Unit Of Measure � Per
CV31001 RaCk. 7 ; 48.97 s 48.97
Cut Pole Top, Inciudes: Cut Poio And Remove Oround Wire As
OHA4101 Required. Unit Of TNessure ■timit Of One Per Work Point 1 i 88.84 ; 68,84
8etup Ug For Puiling Cable Thru A!0 Primary: lncludea 8et Up Truck,
Any (Vecesaary Rigging, TaOboard, Pereonai Protective Equipment,
Preparing Cabie To Putl, Breakdown, And Cleanup After Pull. Used an
ProJecta With 300' Or Less Of Cabie (exciudea 3econdaryy 3ervices,
CB2d021 And St LlgMj. Unk Of Meaeu►++� One Per proJact 1 E 81.21 S 89.21
in-Ifnelunderslung Disconnsct Includea: Assemble Discormect And
Deadenda, Instaii Diaconnect And Deadenda, Temporary Jumpor, Sap
OH41201 (aa Requlred), Jumpero And Connecttone. Unit Of Measure = Each, 1 S 88.40 = 88.40
Oh 9ervice, Quad Any Slze, Any Length, Inctudes: Setuptbreakdown,
Amr Neceasary Cover, Service, Hardware, Decadents), ConnecUons On
Both Ends, 3ag, Voltage Test, Phase Maricinp {rotatlon), And Cleanup.
(removai Includas Open Wire Or Bundled.) Excludes �Ie1d AssemWed
SV9020R Servlces: Unit Of Meaaure � Each. 1 ; 114.89 s 114.89
Arrestor, Distributlon. includes: Atrestor, VYildlife Protectlon, Ground,
And Mount Bracket When Appilcable, Jumpers And Connectbn's). Unit
OH41701 Of Measure � Each. 2 S 63.64 � 12T.08
Pols Risor, Above 3". Inciudes: 3etup16reakdown, Hardwere, Conduft
U78040R W/puil8tring, And Brackets. Unit Of MQasuro a Each. 1 ; 129.82 S 129,62
Ground Rod, Dirt Inciudes: load dround Rod, Clamp, Cunnector,
Conducto� As Requlred, Lacatos, Excavate 9ite, tnstali t3round Rod,
Inafail Conductor, Make Connsctlons, Backfili, And Cleanup. Unk Of
�� 18fl� Measure = Each. 3 S 47.72 ; 143.18
Bracket, 8tandoff (1 Or 2 3ingle Phase, Or 1 Or 2 7wo Phesej,
Fiberglass. Inciudes: Drllling Pok, Bracket And Mountlng Hardware.
��� Unit Of Measure � Each. 7 S 22.80 f 159.60
Prlmary Cabie For Pols Rlser, Three Phaee Through 4I0. Inciudea: 8ot
Uplbreakdown, lnstailing Pull Rope, iden8fying Phaaes, Pulltng Cab(e
INout Of Condutt, Malrrtatning Motsturo 3eal At Cable Enda, And
C820131 Cleanup. Unit Of Meaeure= Par Wser. 1 S 158.b8 S 189.68
Arreator, Dlatributlon. includea: Arrostor, Wlldlife Protect(on, Oround,
And Mount Bracket UYhen Applicabla, Jumpera And Connectlon'a). Unk
�H41TOR Of Measurem Each. 4 ; 44A2 ; 176.08
Oh Service Connection's). Includes: ConnecHons On Both Hnda And
3V90901 Vottage Teat Unk Of Measure m Per 3ervice. 4 $ BO,BU
f 242.40
Wildl{fe ProterstloR Appllea anly To Installadon On F�claUng
M37180i Equipmant Inciudea: Probector. Unk Of Measure � Each. 27 $ 9.39 $ 2B3.53
In-Iins/underotung Dlsconnect Includea: Assemble Disconnect Md
Deedends, Insfali Diaconnect Md Deadends, Temporary Jumper, 8ag
(as Requlred), Jumpers And Connecdons. Unit Of Measure= Settlf
OH41211 Three. 1 s 259.22 t 2b9.22
.•- •-
'• : ' �� .. .� .� �. .� . .�� . ... .. . ..
�. �ii�01'�C Vfl�t ' .. , � .. . . ..
, , • • ;. : D6l�CI'IpE1011 �`Btltlla�d .COSt
�, .
.: • �
., ,..�
tlam ' stimated ,
.... . . . . �: ., . : .. . . . t! C�� Unl �.
in-Iinelundaralung Disconnect Innludes: Assembla Df�connactMd
Deadands, install DlsconnactAnd Deadends, TemporaryJumper, Sag
(ea Requlred), Jumpors And Coonectlons. Unit Of Meaaure � 9et Oi
OH4721R Three. 9 ; 289,22 S 259.22
Pad MountloverNeadlsuhaurtacefveuk Equipment, Three Phaea, To
Includa Trartaformer, Swkchgear, Primary Metering Cabinet Or Cabinet
Of My Kind. Includaa: Delivery To Job 8ite, Setuplbraakdown, Md
T3tS0101 3et Unit Oi Meeaure = Each. 1 � 276.73 B 270,73
StralghtSplico, Primary, Through4/0. Includes: Satuplbreakdown,
Cabla Preparation, Lug, Pro-molded 8plice, Tagsftagging, Oround, And
UT81001 Cisanup. Unit Of Measure = Each. 8 S 94.40 s 283.20
Down Ouy Or Polo To Pote Guy, Any 9ize, All Lengths. includes: Pole
And Anchor Attechment Hardware, Ouy, c3roundlguy Inaulato� Ae
OH4380R Required, Ouy Tenaion, And Ouy (ivard. Unit Of Measuro = Each. 9 ; 31.70 ; 286.30
Oh 3econdary, Through 410, Through 4 Conductors. (does Not Includa
eare Conductor) Includes: 3econclary, HaMware, Jumpers,
ConnecUons On Both Ends, And Voltsge Test Exciudas Set Up, Cover
Up, Deadends And Fleld Asaembled 3econdary. Doas Not Includa
OH41951 Transfer. 9ee Oh4260. tlntt Of Nleaaure = Per Foot 212 S 1.88 S 394.32
8wftch, Loadbroak, t3ang Operated Or Scadamete. Includes: Uncrata,
Assemble, Mount switch, Arrestoro, Temporary Jumpero, Orounds,
WlidliFe Protectlon, Operate 3witch, AdJuet As Needed, And Cfeanup.
OH4M30R Exciudes PermaneM Jumpere Unft Of Meaeure p Each. 1 s 421.b2 ; 421.52
Primary CaWe, 8i�gle Phase. Inciudos: Set Up/breakdown, Puiling
Cable IrJout Of Conduit, Maintaining Molsture Seai At Cable Enda, And
CB20001 Cleanup. Unit Of Meaaure = per Foot 586 $ 0.8Z a 4b7.a8
ob 3econdary, 7hrough 4/0, Thraugh A Conductors. (does Not Include
Bare Conductor) Includea: 3econdary, Hardware, Connectlona On Both
Ends, And Voltage 7est. Exc�udes Set Up, Cover Up, And Fleld
Assembled Secondary. Doea Not Inciude Trensfer. 3ee Oh4200. Unft Ot
OH4198R Meaeure � Per Fooi 344 Z 1.41 s 485.04
Terminate, Prtmary Cabie Pole Rlaer, Three Phese, Through 4l0;
Includea: Hardware, Bracket, t3�ip, Terminators, Tarminal lugs,
arounda, Jumpers, Lightning Arrestors, 3eaiing Compound,
Connectlons, Wildlife ProtecEion, And Tagaltagging. lln(t Of Meaeure 4
UT80101 Each. 1 S A89.25 i 489.25
Pull Box, Primary, Three Phase. includss: F�ccaveUon, Providfng And
Installing Pea Gravel Base, Cable Rack, Connect Conduit, Ground Rod,
eackfill, Compactlon, 8et 7o Final Grade, 34cure Enclosura, Fln Plate,
CV31401 Md Cieanup. Unit Of Measure � Each. 1 S 624A1 : 62A.41
PHmary Cable For Pde Riser, ThreA Phase, Larger Than 4/0. Includee:
Set Uplbreakdown, lnatallinp Pull Rope, IdenUtylnq Phases, Pullfng
Cable in/out Of Conduit, Malntalning Moisture 3eal At Cable Ende, Md
CB2023i Cleanup. UnJt Of Meeaure = Per Riser. 2 s 278.79 S 553.58
Dea�nd Conductor. Secondary Or Neutral, My Sirs. Includea: �
lnsulaEor Andtor Dead�end, Hardwaro And Sag. Bundled Conductor
OH409oR Considered One Dead-end. Unk Of Meaaure = Each. 23 = 24.89 S 687,87
Pole Riser, Above 3". inctudea: 3otuptbreakdown, Hardware, Condutt
UT6040) W/pull8tring, And Breckets. Untt Ot Measure m Each. 3 S 211.20 s 633.80
Dead-end Conductor, Primary, Larger Than 4/0 Wire. inciudes:
Insutator Andlor Dead�nd, Hardware, And 3agging, Unk Of Measure =
OH40801 per Conductor. 18 S 51.04 � 785.80
Trnnaformer, 3ingte Phaee, Over SOkva On Pole Or Plallorm. Includes:
Tranaformer Leadaljumpers As Required, Connectlona, Wildlife
• Protectlon, Verify Voltage, And Claanup. Excludas Brackets Unit Of
OH4340R Meaeure = Each. 3 S 288.88 = 797.Q4
Cutou� Fused Or 3olld Blade. tnciudea: Mount Cutout On Bracket As
Requ(red, Drill Hote'a) As Required, Hardware, Cutout, AndJor Bracket,
OH41101 Fuse, Jumpers) And ConnecUon's). Unit Of Measure = Eaeh. 17 S 48.43 � 823.31
.�: .-
� Wb1'k Unit � � , . �'p�sCri�tloh . . . Estia"ted .` Estimated ' Eatlmabed Coat
- i � n �odt P � �
Oh Servke, Dupiex Or Triple�y Any S(ze, My Length. Includes:
3etup/breakdown, Any Necessary Cover, Servica, Qecade�s),
Hardware, Connecttons On Both Enda, Sag, Voitaga Test, And
Cleanup. (remov� Includes Open 4Yire Or Bundtad,) Exc�udes Fleld
3V9� Assembied 3ervices. Unit Of Measure � Each. 8 $ t0a.6S = 888 20
Cutout Fused Or 3olid Blade. Includes: Mount Cutout Qn Bracket As
Requlred, Drill Hole's) As Requlred, Hatdware, Cutout, Andlor 8racket,
OH4110R Fuse, Jumpers And Connection's). UnR Of Measure = E.�¢h. 21 S 46.07 # 946A7
Pole, Wood, 66', Machins Dig Wkh Auger. Inciudes: FMW Pola, Locatsa,
Setuptteardown, Dig Hole, GroundingJguard As Requlred, Sat Pole,
BackN11, Tamp Or Foam As Requlred, Pola Plata, Fin, Drhren Ground
P310321 removal Onty), Cleanup And Haut-ofF Ot 8potL UnR Of Meaaura = EacA. 2 ; 618.18 s 1,038.3Z
Conduit, 20' 3taik, 4" Through 6, Pvc. Inciudes: Conduft In Trench,
Couplings, Bends, Glue, Piacement Of Marker 8all' As Requlred, And
CV31401 Pull Tape. Unk Of Measuro = Per FooG 1148 S 0.98 � 1,134.54
Trench, Dirt 3T"'firough 60" Dapth And Through 12" VYidth. includas:
Locataa, Excavatton including Any Hand Digginp Baokfiliing, Normai
CV30101 CompacUon, Ar�d Cisanup. Unft Of Messure = Aer Linea� Foot 333 i 3.b0 $ 1,186.60
Dead-end Conductor, Primary, Through 4!0 Wire.lncludea: Inaulator
Andlor Oead-end, Hardware, And 8agg(ng. Un(t Of Maasure � Per
OH40TOR Conductor. 86 S 14.81 ; 1,258.86
Tranafonner, Single Phese, 80kva And Below, Or Indivtdual Capacikor
Unit On Poie Or PleHortn, lnciudse: 7renafo�ner LeadafJumpars Aa
Required, Connectlons, YVlidiffe Protectton And Verity Voltage.
OH43301 Excludes Bracketa Un(t Of Measure = Eaah. 10 ; 126.48 i 1,284.B0
Transformor, Singla Phase, 60kva And Below, Or Indtviduel Capacitor
Unit On Pofe Or Pletform. includes: i'ransformer Leads/jumpeia As
Required, Connecttons, Wlidlifa Protectbn And VeH(y VolEage.
OHA330R Excludes BreCketa. Unit Of Measur9 � EBCh. 18 : 73.44 ; 1,321.92
Terminate, PHmary Cable Poie Rtser, Thrae Phase, Larger Than 4/Q.
Includes: Hardwere, Bracket, �rip, 7erminators, Termina! Luge,
Qrounda, Jumpers, Lightning Arrestors, 8eail�e Compound,
Connecttons, WiIdINe Protectlon, And Tage/tegging. Unit Of Measure �
UT80201 Each. 2 ; 706.20 S 1,412.40
Crosaarm, Woodlflberglasa, Up To 10', Singis. inciudea: Drilling Po(e,
Crassarm, Bracee, And Nlountlng Herdware. Excludee pins, Insulatora,
�Q�� Deadenda. Unit Ot Meaau� � Each. 42 S 38.03 S 1,4y2,10
Conductor, Extension, {bundied Conductor Consldered Ae One
Eonductor), Up To 10'. Inciudes: Conductor, Temporary Jumpey And
OH42401 8plice's). Unit Of Measure = Each. 18 ; 88d1 ; 1,691.38
Crosaarm Woodlflberglaes, Up To 10', Doubie, includea: OMlling Pote,
Crossarm, Braces And Mourrting Hardware. Excludaa Pins, tnsuMtora,
OH4040R peadenda. Unit df Meaaure = Each. 23 � 70,13 S 1,612.89
Croasarm, Wood/flberglass, Up To 10', 3tng(e. includes: DriQing Pole,
Croesarm, Braces, And Mourrting Hardware. Excludes Pins, insulators,
OH4030R �eadends. Unk Ot Measuro � Each. 89 $ 28.38 s 1,673.24
Oh Jumper.permanerrt Includaa PNmary Or Secondary: Conductor,
OH4026R An Nxassary Tie , And Cannections. Unit Of Measure �+ Each. 89 E 24.87 S 2,195.53
Down Ouy O� Polo Ta Pole Ouy, Any Size, Ail t.engtha. Includes: Pole
Md Anchor AttachmeM Hardware, Ciuy, t3roundtguy insulator As �
oli4380! Requlred, Ouy Tension, And c3uy Guard. Unit Of Measure n Each. 46 s SO.Ug = 2,282.25
Dead-end Conductor. Secondary Or Neutral, My Siza lncludea:
Insulator And/or Dead�end, Hardware And Sag. Bundied Conductor
OH40901 Conakiered One Dead-end. Unit Ot Measure• Fach. 47 : 49.43 S 2,323.21
Crossarm Woodlflbarglaes, Up To 10', Doubie. Includas: Drilling Pole,
Crosaarm, 8racea And Moundng Hardware. Exciudes Pine,lnauiators,
���� Deadenda. Unit Of Measure= Each. 32 S 78.80 S 2,457.80
Oh 8e4up, New Constructlon, Large ProJecta (4 Work Points Worksd
Or Morej Per Work Poirtt Worked. includes: Truck 3et•up/broakdown,
Tatiboard, Peraonal Protecflve Fquipmerrt, Work Aree Protectton,
Normal Trafiic Control And Cleanup. Excludea 3ervices For 3ervice
OH40101 Departmertt Unk Of Meaaure � Each Work Point Worked. 70 a 47.06 f 3,293.60
:�: �_
. � .. . . .. . : Estlambe.d Estimated
. worir unft � � . . . D'es�riptfo� � ' ' . .'. �j st R it. �stlmated cdst
Mchor, F�cpandinplplate. Machina Dig. InciuQes: Load AnchoNrod,
Locates, Aeaembk Anchor, Setup/breakdown, Dig Hole, Instaii Anchor
P310901 Wl Rod, Backflil, Tamp, And Cleanup. Unit Of Meaaure ■ Each. 23 i 166.15 S 3,691.46
Pole, Wood, 60' Through 80', Machine Dig With Auger. Inciuder Haui
Pota, Locatsa, 8atuplteardowtr, Diy Hoia, Groundfngf9uerd As
Required, Locataa, 3et Poie, Beckflll, Tamp Or Foam As Requlred, Pole
Plete, Fin, Ddven firound (removal Only), Cleanup, And Haul-oft 0/
P31010R 5poil. Unit Of Measura = Each. 12 S 336.7d S 4,029.00
Dead-end Conductor, Primary. Through MO Wire. tncludea: Inaulator
Andlor Dead-ond, Herdware, And Sagping. Unit Ot Meaaure � Per
OH40701 Conduchor. 148 s 28.00 S 4,080:00
Prfmary Cable, Three Phasa, LergerThen 4I0. lncludes: 3et
Uplbreakdown, Idantifying Phasea, Puliing CeWe tnlout Of Conduk,
Malrriaining Moisturo 3ea1 At Gable Ends, And Ctaenup. Excludes
C820201 Crene Coat Unit Of Measure ■ Per Foot 813 S 3.7b ; 4,674.7a
Hend Dig Hole For Pole Throuph 60'. Inoludes: Locatss„
Setuplbreakdown, Dig Hoia, And secu�ing Site For Pubilc safety.
P810401 Excludea Rock Dlgging. Unit Of Measure � Each. 44 $ 11T.14 ; B,184.16
Irreuletor Or Mesaenger Ciamp, AII Voltnges (excluding Dead-end
insulatora), Primary Or Secondary. Includss: Inaulator, Pin►raak,
D�Ilifng if Required, Hardware, And Securing Conductor To ineulator.
OH41001 UnR Of Measare 4 Hach. 210 a 26.08 ; 8,286.80
fnsulator Or Msesenger Clamp, All Voltagas �excluding Dead-end
Ineulators), Primary Or Secondary, l�cludes: Inautator, Pin/rack,
DrlNing I} Rsquired, Hardware, And Securing Conductor To tnauletor.
(thle Unk Will Cover Installing 3preaders in Rte On A Pole Chanpe Out)
OH4100it Unit Of Measure � Each. 288 S 20.07 5 8,780.16
Oh Jumpecpertnanetrt inciudes Primaty Or3econdery: Conductor,
OH40231 My Neceseary Tie, And Connectlona. Unit Of Mearure' Each. 132 E 64.32 s 7,170.24
Poia, Wood, Through 48', Mechine Dig Wkh Auger. lncludes: Haul Pole,
Locatee, Setup/teardown, Dig Hole, Oroundinglguerd As Required, Set
Pole, Backfiii, Tamp Q� Foam Aa Required, Pole Plate, Fin, Drtven
t3round (removal Oniy); Cleanup And Haul-off Of spoll. Un(t Of Measure
PS10001 � EaCh. 24 S 330.84 a 7,840.18
Pole, Woad, 50' Through 60', Machine Dlg With Auger. Includea: Heul
Polo, Locatea, 3etuplteardown, Dig Hole, G�oundinglgueM Aa
Requlred, locates, 9et Pole, Backfill, Tamp Or Foam As Required, Pole
Plate, Fln, Driven Ciround ��emoval Only), Ciaanup, And Haut-off Of
P810101 Spoil. Unit Of Meaaure � Each. 22 3 439.27 a 9,868.94
Poie, Wood, Through Ab', Machine Dig With Auger. Includas: Haul Pole,
' Locatea, Setup/teardown, Dig Hole, Groundinglguard Aa Requlred, 9et
Pole, Backfill, Tamp Or Foam As Requlred, Pole Piate, Fin, �Mven
Ciround (removal Oniy), Cleanup And Haui�oft Ot Spoil. Unit Of Measure
PS1000R = Eact►. 49 i 228.93 s 11,119.87
Covar•up. inctudee: Placement And Removai Of All Rubber Biankot(s)
And/or Ali Rubber Hoaes Required Per Work Polnt, Unk Of Measure �
MS7U001 Each Work PoiM. 194 S 80.30 = 91,898.20
Bare Conductor, Any Size. Includes: Roilere, 8wing, Rope, Conductor,
OH4190R And Cloanup. Unit Of Measure = Per Foot, Per Eonductor. i8496 S 0.16 S 12,Q79.38
Set Up(breakdown, TmnsionerAnd Pu11er, inciudea: Tensloner, Pulling
Rig, Grounding, Pull Rops, Conductor Preparatlon And Conductor To
OH41801 First Roller. (any Numqer Of Conducton) Un(t Of Meaeure = Each. 19 S 667.97 i 12,891.43
Bare Conductor, Any 91ze. Includes: Rollers, String, Rope, Conductor,
' OHA1901 And Cleanup. Unit Of Measure � Per Foot, Per Conductor. 38819 Z 0.47 S 16,103.93
$ 162,425.98
Page Number 6
�I�C R
�
Electric Delivery LLC
ONCOR WR No.: 3780324
Descriptlon: White Settlement Brldge
As of Date: b/2812013
Estlmate VO(D Date: 8/29/2013
Page Number 7
Esdmate Values are good for 80 daya
5113,411.16
:�: .:
V i �1 �,,,
��
Electria Delivery LLC
ONCOR WR No.; 3180324
Descrtption: Whtte Settlement Bridge
As of Date: 5/29/2013
Estimate VOID Date: 8/Z912093
Estimate Vafuea are good for 90 days
� .� ���hibit "B►� - �Tou�her�s Estir�at� � .
Description � � � �stimfiteti` � . �stimated � Estimated.
� . .. � . . .. . . . Quantt ' Unit - ,
� • Cost.perUnit . � �os��
Contract Design Assistance 124 hours $ 125.00 $ 15,500.00
Contract CADD Assistance 100 hours $ 150.00 $ 15,000.00
Surveying
2S hours $ 125.00 $ 3,5Q0.00
� 34,000.00
Page Number 9