Loading...
HomeMy WebLinkAbout(0185) Plans for Council.pdfComposition Roof to be specified by Owner bll C)^^,- PiFilnoc cr,o.,NPo l ^v P? ^JC Pl.-nn INSULATED CLG. JOISTS DRYWALL SURFACE Front Elevation DRYWALL SURFACE 2X4 INSULATED STUDS @ 16" O.G. MONOLITHIC SLAB (TO BE DESIGNED BY FOUNDATION ENGINEER) ROOF MATERIALS AS IONS NG OARD FOP PLANE FASCIA BOARD SOFFIT SIDING PER PLAN 1/2" 5HEATHING W/ VAPOR BARRIER SINGLE 50LE PLATE TYP,. WALL SECTION (RIGHT WALL SCALE 1 " = 1'-0" Rear Elevation NEZ Strategic Plan Area Design Guidelines APPROVED APPROVED By Victoria Rainbow -Jackson at 1:03 pm, Jul 31, 2020 All construction must meet or exceed locally adopted building codes. Living Area 1 st Floor: Garage: Entry Porch/Gourtyard: Back Patio: GENERAL NOTE5: 1. All penetrations in top or bottom plates for plumbing or electrical runs to be sealed. See electrical notes for additional specifications. 2. Provide 1 /2" water proof gypsum board around all tubs and showers. 3. Vent dryer and all fans to outside air thru vent with damper. 4. All linear dimensions located on exterior walls originate at outside of veneer. 5. All linear dimensions located on interior walls originate at centerline of interior walls. 6. All doors should be located min. of 3" from each intersecting wall. 1. Verify attic access location with owner. 5. All cabinet specifications should be verified by owner. cl. All door roughing dimensions should match manuf. specs. EXTERIOR NOTE5: 1. All exterior columns/posts to be built from 2x4 studs, wrapped by Hardie Panels. and Hardie Trim. 2. All Corner Boards, Fascia, Soffit, Frieze & Trim to be Hardie Material. 3. All 1 x2 Board-N-Batten is 12" on Center. 4. All Tongue & Groove Cedar to be smooth side out. 1, q2q Sq r 1=t 513 5q r Ft 5311 5q r Ft 105 Sq r Ft r • I • ra Win ul E 0 OE 0 U V m E Ln o 0 . Ln s X X � � Q a oO � N co s 0 � w 0 a m m ai Nr x f DATE: 7/16/2020 SCALE: 1 /4" = 1 ' SHEET: 1 NEZ Strategic Plan Area Design Guidelines APPROVED 01 APPROVED By Victoria Rainbow -Jackson at 1:03 pm, Jul 31, 2020 Left Elevation 0 Right Elevation All construction must meet or exceed locally adopted building codes. Living Area 1 st Floor: Garage: Entry Porch/Gourtyard: Back Patio: GENERAL NOTE5: 1. All penetrations in top or bottom plates for plumbing or electrical runs to be sealed. See electrical notes for additional specifications. 2. Provide 1 /2" water proof gypsum board around all tubs and showers. 3. Vent dryer and all fans to outside air thru vent with damper. 4. All linear dimensions located on exterior walls originate at outside of veneer. 5. All linear dimensions located on interior walls originate at centerline of interior walls. 6. All doors should be located min. of 3" from each intersecting wall. 7. Verify attic access location with owner. b. All cabinet specifications should be verified by owner. q. All door roughing dimensions should match manuf. specs. EXTERIOR NOTE5: 1. All exterior columns/posts to be built from 2x4 studs, wrapped by Hardie Panels. and Hardie Trim. 2. All Corner Boards, Fascia, Soffit, Frieze & Trim to be Hardie Material. 3. All 1 x2 Board-N-Batten is 12" on Center. 4. All Tongue & Groove Cedar to be smooth side out. 1, q2q Sq r 1=t 513 5q r Ft 5311 5q r Ft 105 Sq r Ft r • • ra Win ' ^ 1 L/ E 0 OE 0 U V f m Ul U Ln t— X (a Q N � (6 Ln Co (a s w � �N Q) > J O a m m x f < O 4 o cA DATE: 7/16/2020 SCALE: 1 /4" = 1 ' SHEET: 2 I I I I I L — — — J -11/2" If3 I/ ° 1 m ®� 14' 24'-10" +Q O � � N 5-111/2"N I J — iry 3 6 rA 1 3 Bench `Y � 3 o II L W 3065 C N O m S M � o O O - ^ - \ • m 4'7 N(,1�% dJM M 068 '- rn n\ 21' 32-5 1/2" 25-6 1/2" 2020FX 2020FX f11 2020FX 2020FX 1'-11" � 3'-1 7/6" 2' 2'2' l' 1 1/4" 2' 2' 2' 5-3 1/5' 1'-10 1/2" Vaulted Ceiling (No Attic) 2il �_ 10' Flat ceiling 8'-3 1/2" -rE 3' ��E rn 14'-5" 3066 25-1 1/2" 8'-10 1 /4" 1'-1 1/2" 2'5-8 3/4" 20505H I 85-0 1/2" = 6'-8 3/4" 14'-5 1/2" 8'-1 2' 3'-1 3/4" 1` 2, �' 2' 1 -b 2'-8 1 /4" 3' - 20505H 2O505H 3040L5 "P-q 3016L5 2'-1" 3' - - 4'-5 1/2" 6' 4' d? cn courtyard ceiling Vaulted - No Attic Space U, vu, Ln Q. 12-5" 6' l" o_ o a o (V (V �p C> m Im ® Q m N I X I c\ o U, r w - _ �f m E2_4" O �O X o N O ° _ I m o � rr u1 D (V SM ry > I N E -. - ^ - 3 > (� o a m % :3-- - N O co m T M 0 I 0 m 2' 'T 3/4" LT_ 1' N 14 o CV S m 10'-T 12'-4" r � 2020F� �020F�n­i�2 3016L5 12'-6 TY 2' 2' 2' 2b Val, 1'-q 1/2" 3, 1'-11 1/2" 2-7 1 /2" 32-5 1/2" Door Schedule Qty S ize % d1h Height Description 21'-q 1/2" J J V43142 W3142 W3842 BGVg2141 O OTG3i26% ; B31 1 B31 I BGB38 m L—--_L----Kitchenm m r- - i' 10" 1 4'-3 3/4" - - - - -_- - � 4'-3 3/4" I o 0 o B24R 513461 B24L I N 11'-0 3/4" n 1 Island Bench 6'-10 1/2" 14'-5 1/2 4'-3 1/2" N N N 36" Di ct en Ga Insert 12-5" -A COVERED (COURTYARD) PATIO (V 12-b" X 31'-T 2 N in m m U3 co O Q O O x N m � N m O lV 21' 88'-10 1/2" 52-2 1/2" 52'-l" Window Schedule Qty Size VMth He ight Description 1 1663 L IN 13 " 60 11 Hinged -Door PO4 7 2020FX 24 " 24 " = ixod Glass 2 2063 R IN 24 " 60 " Hinged -Door PO4 1 2050FX 24 " 60 " Fixed Glass 1 3063 L 36 " 60 " Pocket -Door PO4 4 2050SH 24 " 60 " Single Hung 2 3063 L EX 36 " 60 " ext. Hinged -Panel 2 2666SH 30 " 73 " Single Hung 2 3063 L IN 36 " 60 " H inged-Door'304 3 3016LS 36 " 13 " Left.Sliding 2 3063 L/R IN 36 " 60 " Double Hinged -Door PO4 1 3040LS 36 " 43 " Left Sliding 4 3063 R IN 36 " s0 " Hinged -Door D04 1 3050SH 36 " 60 " Single Hung 1 5068 L IN 60 " s0 " Slider -Door PO4 2 3060SH 36 " 72 " Single Hung 1 5 0B0 R EX 60 96 Pivot Door 1 4646R.S 54 " 54 " Right Sliding 2 6060 R EX 72 " 96 " ext. Slider -Glass 1 5616FX 66 " 1S " nixed Glass All construction must meet or exceed locally adopted building codes. 22'-6 1/2" 3060 N � � lV ry li, 1668 3065 Linen 1 7 I� r BenEch N 1m IN — ' 3-0 1 /2" m L - m(nj- to CA > 12' 3016L5 4'-10" 3' 12-3 1/2" 3'-6 1/2" Q m NEZ Strategic Plan Area Design Guidelines �r r . )VED APPROVED By Victoria Rainbow -Jackson at 1:03 pm, Jul 31, 2020 Living Area 1st Floor: Garage: Entry Porch/Courtyard: Back Patio: GENERAL NOTES: 1. All penetrations in top or bottom plates for plumbing or electrical runs to be sealed. See electrical notes for additional specifications. 2. Provide 1/2" water proof gypsum board around all tubs and showers. 3. Vent dryer and all fans to outside air thru vent with damper. 4. All linear dimensions located on exterior walls originate at outside of veneer. 5. All linear dimensions located on interior walls originate at centerline of interior walls. 6. All doors should be located min. of 3" from each intersecting wall. 1. Verify attic access location with owner. 5. All cabinet specifications should be verified by owner. 9. All door roughing dimensions should match manuf. specs. i=LOOR PLAN NOTES: 1. All bathroom cabinets to have 21 " depth and 36" countertop height unless specified otherwise. 2. All kitchen cabinets to have 24" depth and 36" countertop height unless specified otherwise. 3. All level 1 ceiling heights to be 10'-0" unless specified otherwise. 4. Confirm details of fireplace with owner. 1,g2q 5qr Ft 513 5q r Ft 53q 5q r Ft 105 5q r Ft ra QC unm N 0 0E 0 V r m Ln U O � Ln s X x r) Q co s a � w 4, o � > — 0 a m m C4 x >— :3 m o� �C DATE: 7/16/2020 SCALE: 1 /411 = 1 ' SHEET: 3