HomeMy WebLinkAbout(0219) SP-20-030FORTWORTH
City Council Meeting Date:
December 15, 2020
Case Number SP-20-030
ZONING MAP CHANGE
STAFF REPORT
Council District 5
Zoning Commission Recommendation: Continued
Approval by a vote of 9-0 Case Manager
Surplus
Council Initiated
Opposition: None submitted
Support: Two people spoke; 1 letter; Historic Stop Six
Owner/Applicant: Cavile Public Facility Corporation
Site Location: 5400 & 5420 E. Rosedale Street
Proposed Use: Required Plan for PD 1262
UDC Recommendation: Approval
Staff Recommendation: Approval
Yes No X
Laura Evans
Yes No X
Yes No X
Acreage: 5.11
Background:
The proposed site is along E. Rosedale between the intersections of Stalcup Road and Andrew Avenue.
When the PD was first approved, Council approved revised development regulations for maximum
building height, transitional height plane and minimum parking requirement with a site plan required. The
applicant has submitted the required site plan for the development.
During the creation of the site plan, the applicant discovered additional changes need to the previously
adopted PD/MU regulations in order to respond to site conditions. As such, the applicant has proposed
four (4) additional regulation revisions from those initially approved in the original PD. Because no two
sites are alike, these types of request are not unusual as a project moves from concept to an actual site
plan.
The Urban Design Commission met on this case Thursday October 15t", and recommended approval for
all four new regulations.
Below is a table outlining the requested site specific development standards.
Development
Standard
MU-1
Proposed PD/MU-1
Revised
Regulation
Required
Yes
Primary and
4.130 (d) (4) Setback Table, the
33' primary street maximum setback
Side Street
primary street maximum setback is 20'
and 36' side street maximum setback
Setbacks
and the side street maximum setback
to provide 18' clearance for overhead
is 20'.
electrical lines on primary and side
streets.
Yes
Page 1 of 3
4.130 (d) (2) a. Primary street
Primary
frontage. Building facades shall be
Street
located within the area between the
30% primary street frontage to allow
Frontage
property line and the maximum
for guest entry court.
setback for a minimum of 50% of the
primary street frontage of the parcel.
Yes
Surface
4.130 (e) (3) a. Surface parking shall
Allow 4 parking spaces between the
Parking
not be permitted between a building
building front and the street at the
Location
front and the street
entry court and south parking area.
Yes
Individual
4.130 (g) (6) d. 1. Apartments,
No individual street- oriented entry for
Entries
condominiums and manor houses with
each unit abutting the street frontage
street level units shall provide an
to allow for building security for
individual street -oriented entry for each
proposed Senior Living residential
unit abutting the street frontage.
use.
Surrounding Zoning and Land Uses:
North "E" Neighborhood Commercial / railroad
East A-5" One Family / single family
South "A-5" One Family / single family
West "E" Neighborhood Commercial / multifamily
Recent Relevant Zoning and Platting History:
Zoning History: ZC-19-152 from PD 1088 to PD/MU-1; subject site
ZC-19-116 Map Amendment for Stop Six Council -initiated rezoning for stop six
overlay to require certain development standards approved by City Council 9-10-19.
Site Plan Comments:
The site plan as submitted is not in general compliance with the Zoning Ordinance regulations.
1. The applicant is requesting a waiver from the maximum setback requirement for both the
primary and side street frontages. The MU-1 ordinance requires a maximum setback of 20'
along the primary and side street frontages. (Revised Regulation Required)
a. The applicant has indicated that the additional setback is needed for clearance from
existing overheard electrical lines that are along these frontages. Staff recommends
approval.
2. The applicant is requesting a waiver from primary street frontage requirement. The MU-1
ordinance requires buildings be located within the allowed setback area for a minimum of
50% of the primary street frontage. (Revised Regulation Required)
a. The applicant has indicated that they are intending to have 30% of the building in this
location in order to allow for a guest entry court. While this is not an ideal location for
parking, staff feels the location will not have a significant effect on the surrounding
uses or public realm.
3. The applicant is requesting a waiver from the surface parking location requirement. The MU-1
ordinance does not allow for any surface parking space to be located between the building
front and street. (Revised Regulation Required)
a. The applicant is requesting four (4) parking spaces between the front of the building
on Stalcup Road. Since Stalcup Road is the primary street for this development, the
portion of the building facing this street is considered the front of the building.
Because these spaces are located within a front entry courtyard, these spaces will
have minimal impact on the pedestrian realm.
4. The applicant is requesting a waiver from the screening requirements and location of service
areas. The MU-1 ordinance requires apartments with street level units provide individual
street -oriented entry for each unit along a street frontage. (Revised Regulation Required)
a. The applicant has indicated that they are proposing to have all of the units have
entries that are located internal to the development for additional building security.
Staff does not have any concerns with this request
Page 2 of 3
(Comments made by Platting (Subdivision Ordinance), Transportation/Public Works, Fire, Park
& Recreation, and Water Department staff cannot be waived through the Zoning Commission
and City Council. Approval of the zoning site plan does not constitute the acceptance of
conditions.)
Public Notification:
300 foot Legal Notifications were mailed on October 26, 2020.
The followina oraanizations were notified: (emailed October 19, 2020)
Organizations Notified
East Fort Worth Neighborhoods Coalition
Neighborhoods of East Fort Worth
Historic Stop Six NA*
Historic Rosedale Park NA
Historic Carver Heights NA
Handley NA
East Fort Worth, Inc.
Streams And Valleys Inc
Trinity Habitat for Humanity
Historic Handley Development
Corporation
Southeast Fort Worth Inc
East Fort Worth Business Association
*Located within this registered Neighborhood Association
Attachments:
• Area Zoning Map with 300 ft. Notification Area
• Site Plan
• Area Map
• Future Land Use Map
• Aerial Photograph
Page 3 of 3
FORT WORTH.
Area Zoning Map
Applicant:
Cavile Public Facility Corporation
Address:
5400 & 5420 E. Rosedale Street
Zoning From:
PD 1262
Zoning To:
Required Site Plan
Acres:
5.11386435
Mapsco:
79L
Sector/District:
Southeast
Commission Date:
11/11/2020
Contact:
817-392-8043
1421
1011
542333 44515�5 545 5�6 5d6
,y
1444
z
1017
5iO3
W
1022
1021
$
1141
UU
W
1425
{i
• S309
102E
LL
1109
5317
M19
5321
Z
1029
°
1109
1113
1112
5331
0
�
�
�
1117
�,
�
y�
�
n
1119
-
5 311
53A.
E
M1 j
oo
w
1604
7y] =
u`yi
lei 12
L1R❑-'Ji�i�
W
1B13
A'5
552:}
5324
A'
5307
1708
1701
1705
1709
1712
❑
x
L1720
1721
725
- Subject Area
® 300 Foot Notification
729
17M
1705
1'J=
1701
1T32
1704
1705
1 T]t
1708
17M
1712
I:QI
1709
17]
1712
1713
W
1717
1719
1719
1712
1721
72
14
1717
1713
1 T20
1725
172d
1720
1724
1725
1724
1728
1729
1728
1723
1728
1733
1732
1732
1737
1736
1733
173�
1732
�7]3
17$6
5628
1J21 }y};
5501 '
E
5529 5U7
AMIAc A IUIR
L u.
47 pp
WA)Ftfih
t*r
41
kA
►.
SSd1 �
g �rs�ru�ra4v�+�
SUP 7�06 gE09 551 561T 521
0 137.5 275 550 Feet
Created: 10/22/2020 1:17:02 PM
O
u
O
1
H
G
I
I
i
I
E - NEIGHBORHOOD
COMMERCIAL
F
E
D
IIIRETAINING
WALL
6'-0" OPEN DESII
FENCE ALONG
PROPERTY LINE
SLIDING VEHICLE
GATE
1 2 3 4 5 6 7 8 9
E- NEIGHBORHOOD
COMMERCIAL
— — — — — - — I - LIGHT
_ INDUSTRIAL
L
EAST ROSEp
OVERHEAD POWER LINE
TO BURIED
— UNDERGROUND
— sss•s°
++ +
+ _---- + j 2)8CU. Y •I
8------_J INS.
(� I
SIDEWALK ❑ �° ((� a
PLANTING AREA I L
DUMPSTER
ENCLOSURE AND
I I I I I SERVICE AREA ACCESSIBLE
ROUTE B
PLANTING AREA —I TOTAL PARKING SPACES
l PROVIDED ONSITE: 149
PLANTING AREA
+
NO STREET -ORIENTED LANDSC ENTRIES ALONG APING WITH T
ROSEDALE FOR GRASS SOD GROU BEES AND
INDIVIDUAL UNITS 20' MAXIMUM ALONG ROW ON EA COVER
SETBACK AND STALCUP ROAD ROSEDALE
— — --_ — — PROPERTY BOUNDARY
LINE
+ --
+
303'-0"
`�%FRONTAGE
FFE ± 658.00
SIDEWALK
r--- _-- -
----__
I
RESIDENT i 4
COURTYARD L_
\ GROUND COVER
_
\ S SOD
11
I I
—
\\ +
,
PLANTING ARE
_
20' MAXIMUM
_
10
A
�
_ SETBACK
_
—I
MAIN ENTRY &
GUEST PARKING
26' FIRE LANE
�
�
—
i
PROPOSED 15'
ACCESSIBLE
PUBLIC SEWER EASEMENT
\
ROUTE A
112
�
I
1 1
FFE ± 670.00
II I
I
1 1 I I
1
�—
1
RESIDENT
PROPOSED
I
ENTRY
LIMITS OF POND
I
GROUND COVER
1 1
GRASS SOD
____----____
Cc
ACCESSIBLE
ROUTE C
\
i
PLANTING AREA
°a
SIDEWALK
V RETAINING WALL
\ \
o °°°0 10
GROUND COVER
\ \
SIDEWALK
i
o o
\ 26' FIRE LANE
GRASS SOD
o
10 0
0�0
\
°° ®°°°° o `� °B
13
o o a
I
EXISTING TREE TO 2 PARKING
DOa�°a
REMAIN
SPACES IN FRONT
J
o
OF BUILDING LINE
r
MONUMENTAL SIGN
13
�-- - — - — — - — --
- — - — — - —
--
PROPERTY BOUNDARY
- — - —
— — — --------I----_J
LINE
KUTMAN COURT
B
-n---- - - - - -- --- - - - --------,-- - - - -
i i
A-5 - ONE FAMILY A-5 - ONE FAMILY
RESIDENTIAL RESIDENTIAL
I I
1 SITE PLAN
A 1 " = 20'4'
2
3
4
6'-0" OPEN DESIGN
FENCE ALONG
PROPERTY LINE
10 L
PROJECT LOCATION MAP
��
,PROJECT
LOCATION
GENERALNOTES
o a
R
H
_
3
O
to a)
.2R
N 0
0
It
w
OVERHEAD POWER LINE
DOCK BAYS SHALL BE SCREENED FROM PUBLIC RIGHT OF WAY.
TO BURIED
UNDERGROUND
2
ALL SIGNAGE WILL COMPLY WITH TO ARTICLE 4, SIGNS.
3.
ALL LIGHTING WILL CONFORM TO THE LIGHTING CODE.
AND WILL BE SHIELDED FROM ADJACENT RESIDENTIAL PROPERTIES.
4.
PROJECT WILL COMPLY WITH SECTION 6.302, URBAN FORESTRY.
5.
PEDESTRIAN SIDEWALKS WILL BE CONSTRUCTED G
INTERCONNECTING ALL BUILDING AND STREET R.O.W.
/
6.
LANDSCAPE AREAS SHALL BE IRRIGATED IN ACCORDANCE
WITH CITY OF FORT WORTH CODE.
7.
FIRE HYDRANTS WILL BE LOCATED THROUGHOUT THE
DEVELOPMENT IN ACCORDANCE WITH THE FIRE CODE.
/W9
8.
ALL BUILDING EXTERIOR CONSTRUCTION TO BE A MIX OF
MASONRY.
'o
4
A-5-ONE FAMILY
°
RESIDENTIAL
9.
ALL BUILDING HEIGHTS TO COMPLY WITH CURRENT ZONING
RESTRICTIONS
N 1
In N
10.
PROJECT WILL COMPLY WITH SECTION 6.301, LANDSCAPING
� � O 0
� # O
CC,
"t 8
� �
SIDEWALK
11.PROJECT
WILL COMPLY WITH ENHANCED LANDSCAPING
w
c
H
N a'
E
t
PLANTING AREA
I
RE -LOCATED
BUS STOP
II
2 PARKING
SPACES IN FRONT
OF BUILDING LINE
o Z
---
i� O
PLANTING AREA
0 wit,
co
U Y 00 cn i to LO t° r2I to M t°
F
NO STREET -ORIENTED
ENTRIES ALONG
STALCUP FOR
PARKING CALCULAITONS
INDIVIDUAL UNITS
174 UNITS / 0.5 = 87 SPACES E
21,363 SF / 350 = 62 SPACES
TOTAL REQUIRED = 149 SPACES
TOTAL PROVIDED = 149 SPACES
PLANTING AREA
I
I
w
I
N �
z
I
BUILDING INFORMATION
GROUND FLOOR
28,227 G.S.F.
FIRST FLOOR
44,419 G.S.F.
SECOND FLOOR
44,419 G.S.F.
THIRD FLOOR
44,419 G.S.F.
FORTH FLOOR
16,284 G.S.F.
BUILDING OVERALL
178,518 G.S.F.
1 BD. ROOM UNIT
163 UNITS
2 BD. ROOM UNIT
11 UNITS
TOTAL UNIT COUNT
174 UNITS
° o
rn am~.
r 0
O
�202
U jp
c
N
O
Q U
d0a
o]Eoa
°roc -
r O > j
O
E
N E O.
� C N
m
Lii
3
a
L ]i l_L
00 Lll
°
Zco
r
N N
d O X
a
_
���
LJJ Q
^
w
U
c
0� �o
L _ 4
3;
co
a M `X
w r ? a
Ld
0
�0 ^ a
3:�a3�r
V
o 0 -6
G
N ILL 3
\ ARCHITECT/REPRESENTATIVE:
\-�--._ BENNETT BENNER PARTNERS Zonning
500 W 7TH STREET
SUITE 1400 Commission
OVERHEAD POWER LINE FORT WORTH, TEXAS 76102
P t N 20106 00
CONTACT: MICHAEL BENNETT
PHONE: (817) 335-4991
OWNER:
CAVILE PUBLIC FACILITIY CORPORATION
1202 E 13TH STREET
FORT WORTH, TEXAS 76102
PHONE: (817) 333-3400
SP-20-030
APPROVED BY CITY COUNCIL xx/xx/2020
PD/MU-1 - SENIOR LIVING
PD SITE PLAN OF
COWAN PLACE
ROSEDALE PLAZA ADDITION
BLOCK 1R
VOLUME 388-44, PAGE 48
5.0952 ACRES
A-5 -ONE FAMILY PREPARED OCTOBER 27, 2020
RESIDENTIAL DIRECTOR OF DEVELOPMENT SERVICES
A-5 - ONE FAMILY
RESIDENTIAL
SIGNATURE DATE
i I
i i
I I
Previously approved variances.
I II
Requested variance.
1. Per 4.130 (d) (8) Maximum height single -use. Three stories or 45 feet, whichever is less as measured from
5. Per 4.130 (d) (4) Setback Table, the primary street maximum setback is 20' and the side street maximum
the top of the finished slab at grade level to the top of the highest wall top plate.
setback is 20'.
Approved variance: Maximum height single -use. Four stories of 45 feet, whichever is less as measured from
Requested variance: 33' primary street maximum setback and 36' side street maximum setback to provide
the top of the finished slab at grade level to the top of the highest wall top plate
18' clearance for overhead electrical lines on primary and side streets.
2. Per 4.130 (d) (10) a. Three stories, single use: maximum 40 units/acre with surface parking
6. Per 4.130 (d) (2) a. Primary street frontage. Building facades shall be located within the area between the
Approved variance: Four stories, single use: maximum 40 units/acre with surface parking
property line and the maximum setback for a minimum of 50 % of the primary street frontage of the parcel.
3. Per 4.130 (e) (2) Residential Parking Table, Apartment/Condominium: 0.75 to 1 off-street required per
Requested variance: 30 % primary street frontage to allow for guest entry court.
bedroom located behind the front building line; Plus, 1 space per 250 square feet of common areas, offices,
7. Per 4.130 (e) (3) a. Surface parking shall not be permitted between a building front and the street
and recreation (less hallways, laundry rooms, and storage)
Approved variance: Apartment/Condominium: 0.5 off-street parking required per senior or age restricted
Requested variance: Allow 4 parking spaces between the building front and the street at the entry court
dwelling unit located behind the front building line; plus 1 space per 350 square feet of common areas,
and south parking area.
offices, and recreation (less hallways, laundry rooms, and storage)
8. Per 4.130 (g) (6) d. 1. Apartments, condominiums and manor houses with street level units shall provide an
4. Per 4.130 (f) (1) d. A transitional height plane of 45 degrees shall apply to portions of a building above three
individual street -oriented entry for each unit abutting the street frontage.
Requested variance: No individual street- oriented entry for each unit abutting the street frontage to allow
stories, or 45 feet, whichever is less starting from the property line of the one- or two-family district.
for building security for proposed Senior Living residential use.
Approved variance: No transitional height plan requireme ts.
5 6 1 7 8
9 10
ro/ec o. .
Issue Date: 10/23/2020
Rev Description Date
C
B
plot date/time: 10/27/2020 2:57:31 PM
A
SITE PLAN
SP.100
4-
FORT WORTH.
"M
Future Land Use
J
W_
L.L
0
�z
L.F
����rC��� Co►��lettor� �
SAYLE
F-POLLARD-SMITH
t - A -Activity Street
Institutional
tttttttttttttttttt- CMCO - Commercial Connector
Neighborhood Commercial
tttttttttttttttttt- CMU - Commercial Mixed Use Street
General Commercial
tttttttttttttttttt- NC - Neighborhood Connector
Light Industrial
SL -System Link
!
Heavy Industrial
Vacant, Undeveloped, Agricultural
Mixed -Use
Rural Residential
Industrial Growth Center
Suburban Residential
Infrastructure
Single Family Residential
100 Year Flood Plan
Manufactured Housing
Public Park, Recreation, Open Space
Low Density Residential
Private Park, Recreation, Open Space
Medium Density Residential
Lakes and Ponds
- High Density Residential
270 135 0 270 Feet
z
L1J
SI}
'E
I
4,
M
SP-20-030
� �y �'allrFeclor.
WWI
PA
+ firA dA r[ + rl U
N
A Comprehensive Plan shall not constitute zoning regulations or
as tab is hzoning district bow dad as. (Texas Local Government Code,
Section 213.005.) Land use designationswere approved
by City Council on March 6, 2018.
Created: 10/22/2020 1 :16:57 P M
FORTWORTHG
SP-20-030
Aerial Photo Map
w IF
i
+ - ., #
F1L ki�7��
i,
a.
YLE "
�OLLARD-METH
� w r
r � -
R l l D U r -�-
T I T --
a -
yLLIE
61
ROSEEWE
MAC: AR Ufa
_ 4
AtNWRfGHT
+ y
� Ik
PA T-v
N
0 170 340 680 Feet