HomeMy WebLinkAbout(0163) ZC-20-171Case Number ZC-20-171
FORTWORTH
ZONING MAP CHANGE
STAFF REPORT
City Council Meeting Date:
February 16, 2021
Zoning Commission Recommendation:
Approval based on UDC and Staff recommendations by a
vote of 9-0
Opposition: None submitted
Council District 7
Continued
Case Manager
Surplus
Council Initiated
Yes No X
Laura Evans
Yes No X
Yes No X
Owner/Applicant: NTP35 LP
Site Location: 7400 - 8800 blocks NW Highway 287 (north side) Acreage: 52.63
Proposed use: Urban Residential and Mixed -Use
Request: From: "UR" Urban Residential and "G" Intensive Commercial
To: "PD/MU-2" Planned Development for all uses in "MU-2" High Intensity Mixed -Use
with waivers to Setbacks, Yard Standards, Minimum Height Single Use,
Maximum Height Single Use, Off Street Parking, Off -Street Parking and Loading
Standards, Enhanced Landscaping, Landscaping in Parking and Driveway Areas,
Fagade Design Standards, Facade Variation, Fenestration, Building Materials,
Building Entries, Signs, Screening, and Drive -In Business alcohol sales; site plan
required
"PD/UR" Planned Development for all uses in "UR" Urban Residential with
waivers to Setbacks, Off Street Parking, Other Off -Street Parking and Loading
Standards, Enhanced Landscaping, Parking Lot Landscaping, Facade Variation,
Fagade Design Standards, Building Materials, Building Entries, Signs, Screening,
Height, and Density, and allowed uses; site plan required
Land use Compatibility: Requested change is compatible.
Comprehensive Plan Consistency: Requested change is consistent (Technical
inconsistency).
UDC Recommendation: Approval of Staff Recommendations
Staff Recommendation: Approval of:
MU-2: Setbacks, Minimum Height Single Use, Maximum
Height Single, Maximum Parking requirements,
Minimum Parking requirements, Enhanced Landscaping
Requirements, Commercial and Mixed -Use Ground Floor
Fenestration (as amended), Residential Fenestration (as
amended), Fenestration Alternatives (as amended),
Building materials
Page 1 of 13
UR: Rear Setbacks, Minimum Parking Requirements,
Off -Street Parking and Loading Standards (Hwy 287
Only), Enhanced Landscaping Requirements, Building
Materials; Service Area Location & Screening (as
amended), Roof Top Screening, Maximum Height;
Maximum Density
Background:
The site is located at the southeast intersection of Tarrant Parkway and Highway 287, and was zoned to
its current zoning districts in 2019. Surrounding land uses vary, but are predominantly intensive
commercial and similar uses.
The Scope of Work for the project is an approximately 146 acre master planned development at the
Northwest corner of IH-35 & Hwy 287 including commercial & residential. The applicant is proposing
several development regulations that differ from the current "UR" Urban Residential and "MU-2" High
Intensity Mixed -Use zoning regulations. They have stated that due to the varied uses and site
configurations that the modifications to the zoning ordinance are needed. A site plan will be provided at
a later date and will be required to go through the public hearing process.
The proposed development as currently shown has a few multifamily and commercial buildings
proposed, with some garage parking and a substantial amount of surface parking. A majority of the
surface parking is located on the edges of the development, allowing the main streets to function as
urban, pedestrian -friendly areas. The overall layout of the site lends itself to being a regional destination
with its variety of proposed uses.
The primary puropose of the MU-2 district is to provide areas in which a variety of higher density
housing types exist among commercial, institutional, and selected light industrial uses. The higher
density allowed in MU-2 is appropriate in this location. The primary puropose of the UR district is to
provide a transitional zone between one- and two-family districts and more intense mixed -use districts
or non -compatible uses. In this case, the site is not near any single family neighborhoods, and is
surrounded by intensive commercial uses and major roads, including two highways.
There are a number of requests from the applicant that staff does not feel comfortable supporting at this
time due to lack of information. When the applicant comes back to submit the site plan for the
development at a later date, it will most likely provide the additional detail needed to make a
recommendation for some of the requested regulations. Denial of a waiver today does not preclude the
applicant from requesting it again at a later date.
At its November 16, 2020 meeting, the Urban Design Commission unanimously voted to recommend
approval to the Zoning Commission for "PD/MU-2" and PD/UR following staff's recommendations.
Below are two tables that outline the current MU-2 and UR regulation, the proposed regulation, and staff
analysis.
REQUESTED MU-2 DEVELOPMENT REGUALTIONS
REQUEST MU-2 STANDARD PROPOSED STANDARD ANALYSIS
Page 2 of 13
Primary Street — 0720'
Minimum rear yard setback
Setbacks
Side Street — 0720'
may be 0'. Buildings may be
Staff supports this
Rear Yard — 5' min
set back up to 11' from a
request
Common Lot Line — 075'
common property line.
Decreasing the
Building facades shall be
Building facades shall be
percentage of the
located within the area
located within the area
building fagade
between the property line and
between the property line
requirement would
Yard Standards
the maximum setback for a
and the maximum setback
not meet the intent of
minimum of 70 percent (%) of
for a minimum of 55%
promoting a
the primary street frontage of
average of the primary
pedestrian -oriented
the parcel.
street frontage.
form and walkability
in mixed -use areas.
Reducing the
Two (2) stories at a minimum
minimum height for
18 feet of occupiable space
Small buildings or single
single use buildings
Minimum Height
as measured from the top of
use commercial buildings
will not have a
Single Use
the finished slab at grade
may be 1 story.
significant impact on
level to the top of the highest
the development and
wall top plate.
surrounding
properties.
Five (5) stories as measured
Increasing the
maximum height for
from the top of the finished
A maximum height of 8
single use buildings
Maximum Height
slab at grade level to the top
of the highest wall top plate.
stories (plus height bonus)
will not have a
Single
is allowed for multifamily
significant impact on
Up to two additional stories
buildings.
the development and
with height bonuses.
surrounding
properties.
Commercial uses in
other zoning districts
have an allowed
maximum parking
Maximum
Maximum commercial,
requirement of 125%.
Staff does believe
Parking
100% maximum
mixed use parking is 125%
that allowing the
requirements
of required.
increase will have a
negative effect on the
development and
surrounding
properties.
Page 3 of 13
Minimum Parking
requirements
Off -Street
Parking and
Loading
Standards
Enhanced
Landscaping
Point
Requirements
Required
Spacing for
Parking Lot Tree
Planting
Townhouse — 2 spaces per
dwelling unit.
Apartment/Condominium
— .75 to 1 space per
bedroom, plus 1 space per
250 square feet of common
areas, offices, and recreation
(less hallways, laundry
rooms, and storage).
Surface parking shall not be
permitted between a building
front and the street, except
angled, perpendicular, or
parallel parking that is
designed to function as on -
street parking
Maximum Surface Parking
Lot Frontage — The
percentage of parking lot
frontage along any street
shall not exceed the following
maximums:
• 40% of the development
site's total frontage length
along a project's primary
streets, and
• 70% of the development
site's total frontage length
alonq a proiect's side streets.
30 points of enhanced
landscaping are required with
10 point from street trees
Every parking space is
required to be not more than
60 feet from a large canopy
tree, planted within a median,
strip or island, measured from
the trunk at planting.
Townhouse - 1.5 parking
spaces per dwelling unit.
Apartment/Condominium
- 1.45 parking spaces per
dwelling unit.
Senior Living (Age restricted
to 50 and over) - 1 parking
space per dwelling unit.
Surface parking shall be
permitted between a
building and the street off of
internal streets and private
drives.
The maximum surface
parking lot frontage shall not
exceed 40% average of the
developments total site
frontage along a projects
primary streets.
Only installation of street
trees and pedestrian level
lighting are required.
Every Parking space is
required to be not more than
100 feet from a large
canopy tree.
The changes in
parking ratios for
townhouse and
multifamily
developments will not
have a significant
impact on the
development.
In other zoning
districts staff has
supported the
reduction of required
parking for
developments that
were shown as senior
living. Staff supports
this reauest.
Allowing parking
between the building
and the street which
is not on -street
parking is not
conducive to a
pedestrian -friendly,
urban, walkable
environment
The request matches
the proposed change
to the MU-2
ordinance that will be
forthcoming. As
such, staff supports
this request.
With the amount of
impervious cover that
is being added, staff
believes additional
trees will increase the
quality of life of the
residents and visitors
Page 4 of 13
Required size of landscape
of the development
islands and linear
landscaping strips containing
trees:
Staff believes the
Within parking lots with non-
5' x 5' diamond -shaped
decrease of the size
porous surfaces: 130 square
landscape islands are
of the landscape
feet; 8 feet minimum width.
permitted.
islands could have a
negative effect on the
required trees
longevity.
Each new building facade
Each new building facade
that is greater than 50 feet in
that is greater than 100 feet
Without a site plan
width and is oriented to a
in width and is oriented to a
that shows the
publicly accessible street or
publicly accessible street or
lengths of proposed
Facade Variation
open space shall incorporate
open space shall
buildings, Staff is not
each of the following scaling
incorporate all scaling
ready to recommend
elements. For building
elements. For building
approval for this
facades less than 50 feet in
facades less than 100 feet
request.
width, a minimum of two
in width, a minimum of two
elements are required
elements are required.
Fenestration:
Ground Story from 2-12'
Commercial or mixed use
above grade:
ground story fenestration
Staff believes the
Primary Street — 60%
may not be 60% fronting
minimum fenestration
Fenestration
Side Street — 40%
primary streets and 40%
for commercial or
fronting side streets,
mixed -use should not
Upper Stories:
depending upon type of use.
be less than 40%
Primary Street — 25%
Minimum 20%.
Side Street — 25%
Residential ground story uses
Residential ground story
The requested
Fenestration
do not have a fenestration
fenestration will be 20 /o
regulation is more
requirement
fronting primary streets and
restrictive than the
20 /o fronting side streets.
zoning ordinance
If the windows do not
meet the visible
transmittance rating
of 0.5 or greater, the
Fenestration alternatives may
Energy efficient windows
alternative can count
Fenestration
count no more than 50
shall count 1 o towards
toward fifty percent of
Alternatives
percent (%) of the total
re
fenestration re uirement
qu.
the fenestration
fenestration requirement
requirement.
Building able to see
into buildings at the
ground level provides
safety and promotes
Page 5 of 13
Fagade Design
Standards
Building
Materials
Building Entries
— Individual
Entries
Building Entries
— Apartment
Spacing
Parking structure openings
shall not exceed
50 percent (%) of the total
ground floor facade.
Not less than 70 percent (%)
of all new building facades
(not including door and
window areas) facing publicly
accessible streets or open
space shall be constructed of
the following masonry
materials:
•Stone
•Brick
•Terra cotta
•Patterned pre -cast concrete
•Cement plaster stucco
•Cement board siding
•Cast stone or prefabricated
brick panels
Apartments, condominiums,
and manor houses with street
level units shall provide an
individual street -oriented
entry for each unit abutting
the street frontage.
Apartments and
condominiums shall provide
primary entrances at intervals
not to exceed 125 linear feet
of street -oriented building
frontage. Entrance spacing is
measured from the edge of
door to the edge of the next
door.
Parking structure openings
may not exceed 70% of the
total ground floor facade. At
least 50% will be covered by
material surface or
landscaping or architectural
screening. See parking
structure conceptual facade
exhibit.
a. Patterned, texture coated,
or textured concrete is
allowed.
b. Maximum 40% cement
board siding may be used
c. Maximum 20% pre -
finished metal facade
material may be used
(requires ACC approval).
Apartments, condominiums
and manor houses with
street level units are not
required to have individual
entries, each building will
have an entry on street
level.
Building entries may be up
to 175' apart. See multi-
family entry exhibit.
interaction between
the private and public
realms
Increasing the
parking structure
openings does not
meet the intent of the
mixed -use ordinance
of promoting a
pedestrian -oriented
urban form.
Per HB 2439 the City
of Fort Worth is
currently not
enforcing building
materials
The requirement for
individual street
entries is intended to
activate the street
and increase
pedestrian activity.
Staff does not
support this request.
If the request for no
individual entries is
granted, staff does
not support
increasing the
primary entry
requirements.
Page 6 of 13
Building Entries
— Corner
Buildings
Signs —
Maximum
Aggregate Area
Signs —
Calculation Area
Signs —
Allowable Sign
Area
Service Area
Location &
Screening
Entrances to corner buildings
with ground floor retail uses
shall be located at the corner
of the primary street.
Maximum sign area 500
square feet per fagade
Sign Calculation Area:
The facade area shall be
calculated by multiplying the
width times the height, with a
maximum calculated height of
15 feet.
For structures exceeding 15
feet in height, allowable sign
square footage shall be
calculated as 1.5 square feet
per linear foot of building
facade.
1. Trash and recycling
collection, and other similar
service areas, must be
located to the side or rear of
buildings and behind the
primary structures on street
frontages.
2. All refuse and recycling
collection containers shall be
located on a concrete pad
and shall be screened on 3
sides by a fence or wall.
An entry or patio shall be
provided on corners of
building on a primary street
with ground floor retail uses
The entry may face a
oaseo.
There is no maximum
aggregate area of signs per
fagade.
The fagade area shall be
calculated at 45 feet.
There is not a reduction on
the allowable sign area for
structures exceeding 15 feet
in height.
If trash and/or recycling
collection is located on the
street frontage, it shall be
screened with a solid wall
on 3 sides with landscaping
and have a metal gate.
Collection areas shall not be
located at front door/main
entry.
Staff supports this
request
Without having a
proposed sign packet
to review staff
cannot support this
reauest
Without having a
proposed sign packet
to review staff
cannot support this
request
Without having a
proposed sign packet
to review staff
cannot support this
request
Staff will support this
regulation if the
language is amended
to "Collection areas
shall not be located
along a primary
frontage"
Page 7 of 13
Roof Top
Screening
Drive-in
Business
Architectural screening
elements of sufficient height
shall conceal roof top
mechanical equipment from
ground level view from
abutting property or abutting
public street (not including an
alley).
Drive-in businesses may be
permitted in accordance with
the use tables in Chapter 4,
Articles 6 and 8, provided that
no such use shall be
permitted to sell alcoholic
beverages for consumption
on the premises.
Rooftop shall be screened
by parapet or built in screen
up to the same height as
roof mounted equipment.
On any sloped roof area,
equipment is to be located
on the side that does not
face a public street.
Drive thru windows are
allowed on establishments
that sell alcohol, but alcohol
cannot be sold at the drive
thru window.
REQUESTED UR DEVELOPMENT REGUALTIONS
The requested
regulation is more
restrictive than the
zoning ordinance
Due to the changing
importance of drive-
thru and pick up
options, staff
supports this request
REQUEST
UR STANDARD
PROPOSED STANDARD
ANALYSIS
Rear Setback
20' for primary structure
Minimum rear yard setback
Staff supports this
may be 0
request
In other zoning districts
staff has supported the
Minimum
reduction of required
Parking
Multifamily — 1 space per
Senior Living - 1 parking
parking for
requirements
bedroom
space per dwelling unit
developments that were
shown as senior living.
Staff supports this
request.
Allowing parking
between the building
Surface parking shall not be
and the street which is
Off -Street
permitted between a building
Surface parking shall be
not on -street parking is
Parking and
front and the street, except
permitted between a
not conducive to a
Loading
angled, perpendicular, or
building and the street off of
pedestrian -friendly,
Standards
parallel parking that is
internal streets and private
urban, walkable
designed to function as on-
drives.
environment.
street parking
Staff supports this
request for the frontage
Page 8 of 13
along Highway 287
The request matches
Enhanced
Only installation of street
the proposed change to
Landscaping
30 points required, 10 from
trees and pedestrian level
the MU-2 ordinance
Point
street trees
lighting are required.
that will be forthcoming.
Requirements
As such, staff supports
this request.
Landscaping
No parking screening is
This is not an ordinance
for On -Street
N/A
required for "on street
requirement
Parking
parking".
Every parking space is
With the amount of
required to be not more than
impervious cover that is
60 feet from a large canopy
Every Parking space is
being added, staff
tree, planted within a
required to be not more
believes additional
median, strip or island,
than 100 feet from a large
trees will increase the
measured from the trunk at
canopy tree.
quality of life of the
Required
planting.
residents and visitors of
Spacing for
the development
Parking Lot
Tree Planting
Required size of landscape
islands and linear
Staff believes the
landscaping strips containing
5' x 5' diamond -shaped
decrease of the size of
trees:
landscape islands are
the landscape islands
Within parking lots with non-
permitted.
could have a negative
porous surfaces: 130 square
effect the required
feet; 8 feet minimum width.
trees longevity
Each new building facade
Each new building facade
that is greater than 50 feet in
that is greater than 100 feet
width and is oriented to a
in width and is oriented to a
Without a site plan that
publicly accessible street or
publicly accessible street or
shows the lengths of
Fagade
open space shall incorporate
open space shall
proposed buildings,
Variation
each of the following scaling
incorporate all scaling
Staff is not ready to
elements. For building
elements. For building
recommend approval
facades less than 50 feet in
facades less than 100 feet
for this request.
width, a minimum of two
in width, a minimum of two
elements are required.
elements are required.
Page 9 of 13
Fagade Design
Standards
Building
Materials
Building Entries
Townhome
Signs
Parking structure openings
shall not exceed
50 percent (%) of the total
ground floor facade.
Not less than 70 percent (%)
of all new building facades
(not including door and
window areas) facing
publicly accessible streets or
open space shall be
constructed of the following
masonry materials:
-Stone
-Brick
-Terra cotta
-Patterned pre -cast concrete
-Cement plaster stucco
-Cement board siding
-Cast stone or prefabricated
brick panels
Apartments, condominiums,
and manor houses with
street level units abutting a
one -or -two-family district, or
along a frontage with an
established residential
character, shall provide
individual street oriented
entries for each unit along
the primary street frontage.
On premise signs on single
family houses, manor
houses with two dwelling
units and townhouses are
limited to one unilluminated
nameplate Der unit bearina
Parking structure openings
may not exceed 70% of the
total ground floor facade. At
least 50% will be covered
by material surface or
landscaping or architectural
screening. See parking
structure conceptual fagade
exhibit.
a. Patterned, texture
coated, or textured
concrete is allowed.
b. Maximum 40% cement
board siding may be used.
c. Maximum 20% pre -
finished metal fagade
material may be used
(requires ACC approval).
Apartments, condominiums
and manor houses with
street level units are not
required to have individual
entries, each building will
have an entry on street
level. Interval of entry
spacing may exceed 125
feet. a. See multi -family
entry exhibit.
Increasing the parking
structure openings
does not meet the
intent of the UR
ordinance of promoting
a pedestrian -oriented
urban form.
Per HB 2439 the City of
Fort Worth is currently
not enforcing building
materials
Because there is not
residential character in
the development,
individual entries are
not required in "UR"
zoning.
Staff will strongly
encourage the use of
individual entries in
order to promote a
pedestrian -oriented
form
Townhomes may have Without having a
signage similar to proposed sign packet to
apartments. review staff cannot
support this request
Page 10 of 13
Signs
Non -
Residential
Signs
Service Area
Location &
Screening
the family name of the
occupants residing in the
residence not to exceed one
square foot in area.
A sign or combination of
signs shall have a maximum
allowable area of exposure
on each dedicated street
frontage of not more than
one square foot of sign area
for each ten linear feet of
frontage along said street;
provided, however, at least
one sign shall be allowed
having an area of 12 square
feet.
An illuminated sign for those
uses permitted that are not
residential is allowed. The
sign shall not exceed 30
square feet in area, shall be
no higher than six feet above
grade, and shall be placed a
minimum of ten feet behind
the property line. Such sign
shall not be placed within 20
feet of drives providing
ingress and egress to the
Trash and recycling
collection, and other similar
service areas, must be
located to the side or rear of
buildings and behind the
primary structures on street
frontages.
2. All refuse and recycling
collection containers shall be
located on a concrete pad
and shall be screened on 3
sides by a fence or wall.
Maximum sign area shall
be 200 square feet. Blade
signs/marque signs are
allowed to be mounted on
building face, and under
canopy or awning.
Nonresidential site signs
may be up to 8 feet above
grade and up to 100 square
feet.
Nonresidential wall signs
are allowed to be up to 10%
of wall area up to 25 feet
tall.
If trash and/or recycling
collection is located on the
street frontage, it shall be
screened with a solid wall
on 3 sides with landscaping
and have a metal gate.
Collection areas shall not
be located at front door
main entry.
Without having a
proposed sign packet to
review staff cannot
support this request
Without having a
proposed sign packet to
review staff cannot
support this request
Staff will support this
regulation if the
language is amended
to "Collection areas
shall not be located
along a primary
frontage"
Page 11 of 13
Architectural screening
Rooftop shall be screened
elements of sufficient height
by parapet or built in screen
shall conceal roof top
up to the same height as
The requested
Roof Top
mechanical equipment from
roof mounted equipment.
regulation is more
Screening
ground level view from
On any sloped roof area,
restrictive than the
abutting property or abutting
equipment is to be located
zoning ordinance
public street (not including
on the side that does not
an alley).
face a public street.
3 stories or 38 feet,
whichever is less as
measured from the top of the
The increased height
finished slab at grade level
Maximum height of 8
will not have a
Height
to the top of the highest wall
stories (Plus height bonus)
significant or negative
top plate.
is allowed.
impact on surrounding
properties
Up to four stories with height
bonus
3 stories, single use = 40
units/acre
The increase in density
Density
4 stories, single use with
65 units per acre allowed
is in line with the
proposed height
height bonus
for all types
increase. Staff supports
(structured parking or open
this request
space) = 60
units/acre
UR is a residential
Allowed
Only residential uses are
Additional building types
zoning district.
uses/building
allowed
are commercial, restaurant,
Commercial and
types
and entertainment
Industrial uses are not
allowed.
Site Information:
Surrounding Zoning and Land Uses:
North "G" Intensive Commercial / undeveloped
East "I" Light Industrial & "G" Intensive Commercial / undeveloped
South PD 1270 / Hwy 287
West "G" Intensive Commercial / undeveloped
Zoning History: ZC-19-173 from I to UR and I to G; effective 3/19/20; subject site
Public Notification:
300 foot Legal Notifications were mailed on November 18, 2020.
The followina oraanizations were notified: (emailed November 16, 2020)
Organizations Notified
North Fort Worth Alliance
West Fork Ranch HOA
Chisholm Ridge HOA
Streams And Valleys Inc
Trinity Habitat for Humanity
Keller ISD
Northwest ISD
Eagle Mountain -Saginaw ISD
*Located within this Neighborhood Association
Page 12 of 13
Development Impact Analysis:
1. Land Use Compatibility
The applicant is proposing a zoning change to PD/MU-2 and PD/UR for a future mixed use
development. Surrounding land uses are primarily undeveloped with three major roadways
surrounding the site.
The proposed zoning for the sites is compatible at this location.
2. Comprehensive Plan Consistency — Far North
The 2020 Comprehensive Plan designates the subject property as General Commercial. The
proposed rezoning meets the below policies within the following Comprehensive Plan:
• Identify and designate on future land use maps mixed -use neighborhood centers and/or new
mixed -use growth centers in rapidly developing areas, based on proximity to future rail transit
and key transportation intersections.
• Locate multifamily units within walking distance of public transportation, employment,
recreation, and/or shopping to increase accessibility and decrease vehicular traffic.
• Locate large commercial and institutional uses adjacent to arterial streets, preferably at the
intersections of other arterials and highways.
• Separate incompatible land uses with buffers or transitional uses. Some land uses have
attributes such as height, proportion, scale, operational characteristics, traffic generated, or
appearance that may not be compatible with the attributes of other uses.
• Encourage urban residential development in appropriate locations to create more walkable,
pedestrian -oriented neighborhoods.
Based on conformance with the policies stated above, the proposed zoning is consistent
(Technical Inconsistency) with the Comprehensive Plan.
Attachments:
• Area Zoning Map with 300 ft. Notification Area
• Site Plan
• Location Map
• Future Land Use Map
• Aerial Photograph
• UDC Staff Report
Page 13 of 13
FORT WORTH.
Area Zoning Map
Applicant:
NTP35 LP
Address:
7400 - 8800 blocks NW Highway 287 (north side)
Zoning From:
UR, G
Zoning To:
PD/MU-2 and PD/UR; site plan required
Acres:
52.62835658
Mapsco:
35EF
Sector/District:
Far North
Commission Date:
12/9/2020
Contact:
817-392-8043
ZC-20-171
�u
a �
�
8917891
o
RLVA 2a012201 2341 2233 23a1d917 8940 8940
2245 2317 89178g17 8940 8357
8941
3101 3101 3021
2329 2301 d317 8900 8900
2301 2399
8900
31,31 3025 3025
3025 (Co 3101
2532225 2221
22A1
88iS
Y* 3025 3025 3Q25
�J
8825 8825 2`'
3025 3=5 3025
2098 8825
ti 2317 2401 L¢i
' 2317 2d01
e"1'
A
PD1 275
PD170
- Subject Area
300 Foot Notification
G
P D 1 270
710-A4
;p
4�
W
w PD710-A
J
J
G
4L
R
0 355 710 1,420 Feet
Created: 11/17/2020 10:31:03 AM
ZC-20-171
Area Map
.rm
N
0 1,000 2,000 4,000 Feet
Created: 11/17/2020 10:30:22 AM
FORT WORTH.
"M
Future Land Use
k� l
IL`TJII�
}
r_
0
A -Activity Street
Institutional
r� CMCO - Commercial Connector
Neighborhood Commercial
tttttttttttttttttt- CMU - Commercial Mixed Use Street
General Commercial
r� NC - Neighborhood Connector
Light Industrial
SL -System Link
!
Heavy Industrial
Vacant, Undeveloped, Agricultural
Mixed -Use
Rural Residential
Industrial Growth Center
Suburban Residential
Infrastructure
Single Family Residential
100 Year Flood Plan
Manufactured Housing
Public Park, Recreation, Open Space
Low Density Residential
Private Park, Recreation, Open Space
Medium Density Residential
U
Lakes and Ponds
- High Density Residential
1,100 550 0 1,100 Feet
ZC-20-171
0
z
Tinercial Cut in
A"
LF
Emma
iw; DES
V)
U)
w
x
w
J
J
c{.
0
1z
N
A Comprehensive Plan shall not constute zoning regulations or
as tab ishzoning district boundaries. (Texas Local Government Code,
Section 213.005.) Land use designationswere approved
by City Council on March 6, 2018.
Created: 11/17/2020 1021.41 AM
41,
.1
THE PRESIDIO
LOTS 1, 7,8,9,10,1 1,1 13,14,15
I ND 16 BLOCK A
CABINET r, PAGE 12801, 12805, &
i I l 2806, P.R.T.C.T.
I I ZONED 'T'
� I \
I
TRACT 29
— 0.70 Ac.
EXISTING LAND USE: VACANT
PROPOSED LAND USE: MIXED USE
TRACT 30
0.70 Ac.
EXISTING LAND USE: VACANT
PROPOSED LAND USE: MIXED USE
TRACT 2s
3.91 Ac.
EXISTING LAND USE: VACANT
PROPOSED LAND USE: MULTI FAMILY
TRACT 31
9.82 Ac.
LAND USE: VACANT
TRACT 27 \
2.85 Ac.
EXISTING LAND USE: VACANT \
PROPOSED LAND USE:
HOTEL/CONFERENCE CENTER \
TRACT 23
1.50 Ac.
EXISTING LAND USE: VACANT
PROPOSED LAND USE:
HOTEL/CONFERENCE CENTER
TRACT 22
8.52 Ac.
EXISTING LAND USE: VACANT
PROPOSED LAND USE: MULTI FAMILY
I
THE PRESIDIO "'
LOTS 1, 2,7,8,9,10,1 1,12, p >-
13,14,15 AND 16 BLOCK A 3
CABINET A, PAGE 12804, 12805, Q Y
& 12806, P.R.T.C.T.
ZONED "I" I W a
F-
J
NORTH TARRANT PARKWAY
,,G°i TRACT 25
/1n 70 70 Ar-
TRACT 19 \
5.14 Ac.
EXISTING LAND USE: VACANT
PROPOSED LAND USE: MULTI FAMILY
TRACT 18
4.46 Ac.
EXISTING LAND USE: VACANT
PROPOSED LAND USE: MULTI FAMILY
I THE PRESIDIO
LOT 1, 2, AND 3, BLOC D
CABINET A, PAGE 12790 & 2791,
P.R.T.C.T.
ZONED "I"
o �T
LOT 3R,
BLOCK 1
LAND USE: VACANT
LOT 2R,
BLOCK 1 I
LAND USE: VACANT I
— — I
LOT 1 R, LOT 10, I LOT 4R, BLOCK 1
I
BLOCK 1 I LAND USE: VACANT
LAND USE:
LAND UOCK CANT ' VACANT
LOT 5,
BLOCK 1
LAND USE: VACANT
LOT 6,
BLOCK 1
LAND USE: VACANT
— ffTREAT WAY
a�
R.o `/�
LOT 7R, BLOCK 1
LAND USE: VACANT I
I LOT 11, I
BLOCK 1
LAND USE :
VACANT — —
I , I
G' LOT 12, BLOCK 1
LAND USE: VACANT
I
I
LOT 8, BLOCK 1
LAND USE: COMMERCIAL/RETAIL
W
U_
ag
O3
a
M�
00
CD a
X d
---
--L,T11G4PA£ES't*A-------
Cie
I TRACT 12
Z
TRACT 11
3.21 Ac.
LAND USE: VACANT
I
i '/411
\
TRACT 14
3.99 Ac.
I LAND USE: VACANT
2.54 Ac.
LAND USE: VACANT
G11
TRACT 13
2.34 Ac.
I
LAND USE: VACANT
TRACT 15
7.20 Ac.
LAND USE: VACANT
♦ � f
\o
TRACT 17 - -- --
4.15Ac.
LAND USE: VACANT
ARCF11 T;ECC= T:
13642 Omega Rd
Dallas, Texas 75244-4514
972-387-1000
TRACT 16
4.40 Ac.
LAND USE: VACANT
ODD BY:
McKeever Companies
2525 Ridgmar Blvd, Suite 440
Fort Worth, Texas. 76116
817-236-6100
PREPARED BY:
GOODWIN<
BARSHALL
z
CIVIL ENGINEERS — PLANNERS — SURVEYORS
2405 Mustang Drive, Grapevine, Texas 76051
(817) 329 - 4373
TBPE REGISTRATION # F-2944
TBPLS # 10021700
�
Vantage±ract, Akvry 7!Eritaye irs[p p
-
-
HERIrR�E
Urw
''
v
rei
z
�
gyros
ej
6
s
v
n
o•
7AnAMiPkW
i�
3
g
Te,rant 9kwp
E H,,MO CA
7�$V
6p
Tharrpwn Rd
L�
rlington TrPJ
SITE
ORT w . TH
arsuey aa�u F7d
Q,as
�
gR.iRKVI
�s+woo
-
d Bw
Basrawo,d ®trd
a
..
a
,4
2
al
VICINITY MAP
N.T.S.
SITE DATA
GROSS ACREAGE: ±54.191 ACRES
EXISTING ZONING: "G" & ''UR"
EXISTING LAND USE: VACANT
PROPOSED ZONING: "MU-2-PD'' & ''UR-PD"
PROPOSED LAND USE: MIXED USE & MULTI -FAMILY
PROPOSED DENSITY: 75 UNITS PER ACRE
LEGEND
TRACT I
PROPOSED "MU-2-PD" ZONING
TRACT 2
PROPOSED "UR-PD" ZONING
EXISTING ZONING BOUNDARY
PROPOSED ZONING BOUNDARY
— — R.O.W.
Director of Plannina and Development
Signature Date
W
N
S
E
GRAPHIC SCALE 1"=200'
0 200 400 600
ZONING EXHIBIT
OF
NORTH CITY ADDITION - EAST
BEING
±54.191 ACRES
SITUATED IN THE
WILLIAM McGOWAN SURVEY, ABSTRACT NO.999
CITY OF FORT WORTH, TARRANT COUNTY, TEXAS
Date: October 2020
COPYRIGHT 2020 - USE BY WRITTEN PERMISSION OF GOODWIN & MARSHALL, INC. ONLY