Water Sampling Table
Location of Water Sampling
Sampling
Quantity
Numberof
Samples
1
2718 LF of Water Pipe
4 EA/1000
11
2
1 Dead End Main
4 EA/1000
4
3
2 Branched off Main
4 EA
8
4
Fire Line
2 EA
2
5
Fire Hydrant
1 EA
1
Subtotal
26
Total Sample Tested (2 Consecutive Passing)
52
Total Estimated Cost for Water Sampling ($30/Each)
$1,560.00
I 50.07 ACRES
PROP. 7'X5' RCB
1
6" WATER METER \
CITY OF FORT WORTH �\
0
VARIABLE WIDTH
SEWER FACILITY ESMT.
INST. # D209069748
D.R.T.C.T.
E:
_F —
)M
EXHIBIT:
CITY COST-PARTICIPATION
8/27/2021
LONE STAR GAS \
COMPANY 50' WIDE RIGHT
OF WAY AND EASEMENT
VOL. 3062, PG. 414
D.R.T.C.T. / PFZOP
sTA n+nn nl
w
i / \ CITY OF FORT WORTH \
\ VARIABLE WIDTH J
WTERLINE EASEMENT
\ COL. 16126, PG. 399
GULF PIPELINE COMPANI'� \ D.R.T.C.T.
16' R.O.W. AND ESMT. \
VOL. 607, PG 392; \ \
VOL. 10701, PG. 459
(D.R.T.C.T.) \
\ \ (ABANDONED BY \
CHAPEL HILL WEST LLC.) \
INST. NO D219153659
\ (D.R.T.C..T) \
CT 1
A TEXAS
APANY \ \
321
N
0 100, 200'
SCALE: 1" = 100'
LEGEND
PROPERTY LINE
EASEMENT LINE
X Ex W EXISTING WATERLINE
Ex SS EXISTING SEWER LINE
- - - - - - EXISTING STORM DRAIN LINE
N 104— w PROPOSED WATERLINE
_*.__SS SS �r PROPOSED SEWER LINE
PROPOSED STORM DRAIN LINE
NOTES:
\ 1. ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH
THESE PLANS AND CITY STANDARD SPECIFICATIONS EXCEPT AS
NOTED HEREIN OR APPROVED BY THE CITY.
2. THE CONTRACTOR SHALL COORDINATE ALL PHASES OF INSPECTION
OF UTILITIES WITH THE CITY PRIOR TO CONSTRUCTION AND/OR
INSTALLATION. ALL PIPES AND PIPE FITTINGS SHALL BE INSPECTED BY
THE CITY PRIOR TO COVERING AND/OR BACKFILLING OF UTILITY
TRENCHES.
3. THE CONTRACTOR SHALL MAKE APPLICATION FOR SERVICES, OBTAIN
ALL PERMITS AND PAY ALL CHARGES, FEES, AND CONNECTION COSTS
FOR EACH UTILITY SERVICE.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING
"AS -BUILT" PLANS TO THE ENGINEER OF RECORD SHOWING ALL
UTILITY INSTALLATION VARIANCES FROM THE FINAL CONSTRUCTION
DOCUMENTS. FIELD CHANGES SHALL BE LOCATED ON THE "AS -BUILT"
PLANS BY DISTANCE TO THE LOT LINES OR PROPERTY LINES.
5. UNLESS OTHERWISE NOTED, ALL CONCRETE USED IN UTILITY
INSTALLATION SHALL BE CLASS "A" (3000 PSI).
6. ALL WATER MAINS SHALL BE A MINIMUM OF PVC C900, DR 18, CLASS
150.
7. WATER AND SANITARY SEWER SERVICES SHALL MEET PLUMBING
CODE REQUIREMENTS.
8. ALL WATER MAINS, UNLESS OTHERWISE NOTED, SHALL HAVE A
MINIMUM COVER OF 48" BELOW FINISHED GRADE.
9. WHEN WATER MAINS AND SANITARY SEWERS ARE INSTALLED, THEY
SHALL BE INSTALLED NO CLOSER TO EACH OTHER THAN NINE FEET
HORIZONTALLY IN ALL DIRECTIONS AND PARALLEL LINES MUST BE
INSTALLED IN SEPARATE TRENCHES.
10. ALL METER BOXES SHALL BE LOCATED IN NON -TRAFFIC AREAS.
11. TRENCH BACKFILL MATERIAL SHALL BE MECHANICALLY COMPACTED
IN 6" LIFTS TO THE TOP OF SUBGRADE TO A MINIMUM OF 95%
STANDARD PROCTOR DENSITY UNLESS OTHERWISE SHOWN ON
THESE PLANS OR STATED IN THE CITY SPECIFICATIONS.
12. ALL BORE PITS, TRENCHES, AND INSPECTION HOLES SHALL BE
BACKFILLED WITHIN 48 HOURS OF THE INSTALLATION OF UTILITY
LINES. THE METHOD OF COMPACTION SHALL BE SUCH THAT A SOIL
DENSITY EQUAL TO THAT EXISTING PRIOR TO THE START OF
CONSTRUCTION WILL BE REQUIRED AS VERIFIED BY AN APPROVED
TESTING LABORATORY. ANY EXCESS OR SURPLUS MATERIAL
RESULTING DUE TO DISPLACEMENT OF UTILITY LINES AND CONDUITS
SHALL BE DISPOSED OF IN A MANNER ACCEPTABLE TO THE CITY
BENCHMARKS
NOTES:
1. THE CITY OF FORT WORTH DESIGN AND CONSTRUCTION
STANDARDS APPLY WHETHER INDICATED ON THESE
PLANS OR NOT.
2. CONTRACTOR SHALL FIELD VERIFY LOCATION AND
DEPTH OF ALL EXISTING UTILITIES PRIOR TO
CONSTRUCTION.
3. ALL T.C.EQ. PIPE SEPARATION MUST BE MET.
4. ALL WYE CONNECTIONS AND BENDS SHALL BE
MANUFACTURED FITTINGS.
5. ALL HORIZONTAL AND VERTICAL FITTINGS AND VALVES
SHALL BE RESTRAINED BY THRUST BLOCKING AND
MECHANICAL RESTRAINT PER DESIGN CRITERIA
SECTION 5.6.3 AND COFW SPEC 33 11 11
6. MINIMUM RADIUS OF CURVE AND MAXIMUM DEFLECTION
ANGLE OF PIPE JOINTS WILL BE RESTRICTED TO 50% OF
MANUFACTURER'S RECOMMENDATION, AFTER WHICH
THE USE OF HORIZONTAL OR VERTICAL BENDS WILL BE
REQUIRED. NO BENDING OF PIPE IS ALLOWED.
7. WATER AND PRIVATE STORM CROSSINGS INCLUDED IN
ENCROACHMENT AGREEMENT: PN21-00085
WATER / SEWER STUDY (WSS) RECORD NO. WSS-2021-1298
BM #1 - 1/2" IRON ROD FOUND WITH CAPS
STAMPED "BROOKS BAKER" IN THE
WESTERLY R.O.W. LINE OF NORTH
= OF
1+
SAGINAW BLVD (US HWY 81 AND STATE
i �P,• '' �9
HWY 287 BUS) IN THE NORTH LINE OF A
TESCO EASEMENT +/- 11,480' FROM THE
/*:
�
"' ""' ""
INTERSECTION OF THE WESTERLY R.O.W.
B SKI
� TH A B RTK
LINE OF NORTH SAGINAW BLVD AND THE
•• .. • •: ••i
/� 99 b
SOUTH R.O.W. LINE OF BONDS RANCH
/
I,
ROAD.
ELEVATION = 822.31'�
�� •.�,C \��i
BM #2 - PK NAIL FOUND IN THE
� ii�
WESTERLY R.O.W. LINE OF NORTH
08/23/2021
SAGINAW BLVD (US HWY 81 AND STATE
HWY 287 BUS) AND IN THE NORTH LINE
PELOTON LAND SOLUTIONS
OF A TESCO EASEMENT +/- 2,100' FROM
TEXAS FIRM NO. 12207
THE INTERSECTION OF THE WESTERLY
THE SEAL APPEARING ON THIS DOCUMENT WAS
R.O.W. LINE OF NORTH SAGINAW BLVD
AUTHORIZED BY THOMAS C. BARTKOWSKI, P.E. # 99976.
AND THE SOUTH R.O.W. LINE OF BONDS
RANCH ROAD.
ELEVATION = 821.95'
U)
Z
w
w
O
z_
0
_J
H
Lu
W
H
U)
(06
V
Z_
0-
Z_
Q
O
I—
00
W
W
W Y
L: U)
Z J
J_
U) =
0Y O
W J
FO
Q m