Loading...
HomeMy WebLinkAboutContract 58879CSC No.-58879 FORT WORTH CITY OF FORT WORTH COOPERATIVE PURCHASE AGREEMENT This Cooperative Purchase Agreement ("Agreement") is entered into by and between Garland/DBS, Inc ("Vendor") and the City of Fort Worth, ("City"), a Texas home rule municipality. The Cooperative Purchase Agreement includes the following documents which shall be construed in the order of precedence in which they are listed: 1. This Cooperative Purchase Agreement; 2. Exhibit A — Seller's Quote, Scope of Services or Purchase Order; 3. Exhibit B — Cooperative Agency Contract OMNIA Partners PW 1925; and 4. Exhibit C — Conflict of Interest Questionnaire Exhibits A, B, and C, which are attached hereto and incorporated herein, are made apart of this Agreement for all purposes. Vendor agrees to provide City with the services and goods included in Exhibit A pursuant to the terms and conditions of this Cooperative Purchase Agreement, including all exhibits thereto. City shall pay Vendor in accordance with the fee schedule in Exhibit A and in accordance with the provisions of this Agreement. Total payment made under this Agreement for the first year by City shall not exceed Fifty Thousand Dollars ($50,000.00). Vendor shall not provide any additional items or services or bill for expenses incurred for City not specified by this Agreement unless City requests and approves in writing the additional costs for such services. City shall not be liable for any additional expenses of Vendor not specified by this Agreement unless City first approves such expenses in writing. The term of this Agreement is effective beginning on the date signed by the Assistant City Manager below ("Effective Date") and ending on October 14, 2023 in line with cooperative contract. Upon the expiration of this Term, the Agreement shall renew automatically under the same terms and conditions for up to six (6) one-year renewal period (October 15 to October 14), unless City or Contractor provides the other party with notice of non -renewal at least 60 days before the expiration of the Initial Term or renewal period. However, if funds are not appropriated, the City may cancel the Agreement 30 calendar days after providing written notification to the Contractor. Vendor agrees that City shall, until the expiration of three (3) years after final payment under this Agreement, or the final conclusion of any audit commenced during the said three years, have access to and the right to examine at reasonable times any directly pertinent books, documents, papers and records, including, but not limited to, all electronic records, of Vendor involving transactions relating to this Agreement at no additional cost to City. Vendor agrees that City shall have access during normal working hours to all necessary Vendor facilities and shall be provided adequate and appropriate work space in order to conduct audits in compliance with the provisions of this section. City shall give Vendor reasonable advance notice of intended audits. Notices required pursuant to the provisions of this Agreement shall be conclusively determined to have been delivered when (1) hand -delivered to the other party, its agents, employees, servants or representatives, (2) delivered by facsimile with electronic confirmation of the transmission, or (3) received by the other party by United States Mail, registered, return receipt requested, addressed as follows: OFFICIAL RECORD CITY SECRETARY FT. WORTH, TX To CITY: To VENDOR: City of Fort Worth Garland/DBS, Inc Attn: Dana Burghdoff, Assistant City Manager Brian Lambert, General Manager 200 Texas Street Fort Worth, TX 76102-6314 Address: Facsimile: (817) 392-8654 3800 East 91st Street Cleveland, OH 44105 With copy to Fort Worth City Attorney's Office at Facsimile: N/A same address The undersigned represents and warrants that he or she has the power and authority to execute this Agreement and bind the respective Vendor. CITY OF FORT WORTH: bares LWALO7 F By: Dana Burghdoff ( 14, 20 19:38 CST) Name: Dana Burghdoff Title: Interim Assistant City Manager Date: Feb 14, 2023 APPROVAL RECOMMENDED: Steve o ke (Feb 10, 2023 17:09 CST) Name: Steve Cook Title: Property Management Director 4ovvuu FORTUu O0 ATTEST: o°°°° %o's, ao RM G 0 °B�.I d -o Pvo oo 0�0=d ti 0 EXASo4" �bnnab4° Name: Jannette Goodall Title: City Secretary VENDOR: Garland/D IIc 4 By: Name: Br an Lambert Title: General Manager Date: 1 I 3 ^ 2'3 CONTRACT COMPLIANCE MANAGER: By signing I acknowledge that I am the person responsible for the monitoring and administration of this contract, including ensuring all performance and reporting requirements. By: Denise Garcia (Feb 2309:11 CST) Name: Denise Garcia Title: Purchasing Manager APPROVED AS TO FORM AND LEGALITY: LIN , 7efflka iVM,11glfff Jessika Williams (Feb 14, 202310:29 CST) Name: Jessika Williams Title: Assistant City Attorney CONTRACT AUTHORIZATION: M&C: N/A OFFICIAL RECORD CITY SECRETARY FT. WORTH, TX EXHIBIT A ROOFING SUPPLIES AND SERVICES, WATERPROOFING, AND RELATED PRODUCTS AND SERVICES CONTRACT 2019 AMENDMENT NO. SIX (6) This Amendment No. Five is effective January 1, 2022 and is to modify the ROOFING SUPPLIES AND SERVICES, WATERPROOFING, AND RELATED PRODUCTS AND SERVICES CONTRACT 2019 agreed upon by Racine County, Wisconsin, 730 Wisconsin Avenue, Racine, Wisconsin 53403 ("County") and Garland/DBS, Inc. 3800 East 91s' Street, Cleveland, Ohio 44105 ("Contractor") (hereinafter each a "Party" and collectively referred to as "Parties") on September 27, 2019 ("Contract"). The Parties hereby agree to amend the Contract as follows: 1. WORK: To add products, delete products no longer available, and modify pricing as necessary (both increases and decreases) to account for market changes in manufacturing and worker safety. Details are provided in the Bid Form located in Attachment A of this Amendment No. 6. 2. PRICE: The County agrees to the revised prices, products, and services, Details are provided in the Bid Form, located in Attachment A of this Amendment No. Six. 2022 material price list details can also be provided upon request. ALL OTHER PROVISIONS OF THE CONTRACT SHALL REMAIN IN THEIR ENTIRETY. 10 nathan Delagrave ?cine County Executive DATE D;1V 0-aa, BY: Z " -tA Wendy 9. Christensen Racine County Clerk DATE: j ILi (0 ,o— GARLAND/DBS Inc. BY: � � oldaedzl DATE: 3/15/2022 Allan A. Orlacchio President REVIEWED BY FINJ�CE- ]RECTOR /S LZ Sin Date Cortlfled to be correct as to form J By _ AA0111e j bt -G p -oration sel ROOFING SUPPLIES AND SERVICES, WATERPROOFING, AND RELATED PRODUCTS Page 1 of 1 AND SERVICES CONTRACT 2019 IFB #PW1925 Roofing Supplies and Services, Waterproofing, and Related Products and Services Attachment C - Bid Form rk<i'�; }` °rSEp�fil�5 "T ;far. h: .a`Yt�.?;:�b.iv.&�<.r ., '. 1.00 Roof Management, Design Assistant andlor Professional Services 1.01 Full-time Quality Assurance monitoring DAY 600.00 1.02 Asbestos core testing and analysis (testing only, excludes labor for sampling and repair) EA 75.00 1.03 Analysis and evaluation (14" x 14" roof core) (Lab testing only, repairs charged at roof repair rates for appropriate system type) EA NSP 1.04 Aerial Roof Survey - Roof Pictures & Drawings Including Geometries, Slope, Calculated Area and Perimeter Measurements EA NSP 1.05 Aerial Wall Survey- Wall Pictures & Drawings Including Geometries, Calculated Area and Perimeter Measurements EA NSP 1.06 Manufacturer Standing Seam Material Quantity Estimating EA NSP 1.07 Nuclear Moisture Survey, Non destructive roof scan 1.07.01 Non destructive roof scan, up to 20 000 SF EA 2,000.00 1.07.02 Non destructive roof scan, over 20,000 SF SF 0.09 1.08 Infrared Moisture Scanning 1.08.01 Non destructive infrared roof scan, up to 20 000 SF EA 1,500.00 1.08.02 Non destructive infrared roof scan, over 20,000 SF SF 0.07 1.08.03 Aerial infrared roof scan at night TRIP 1,750.00 1.09 Infrared scanning equipment rental DAY NSP 1.10 Roof investigation (visual roof survey) 1.10.01 Roof Investigation (Roof by Roof), per hour HOUR NSP 1.10.02 Visual Roof Survey (Roof by Roof) up to 20,000 SF EA NSP 1.10.03 Visual Roof Survey (Roof by Roof) over 20,000 SF SF NSP 1.10.04 Visual Roof Survey (Single Campus - All Roof Sections) SF 0.06 1.10.05 Visual Roof Survey (Multiple Campuses City -/County -wide - All Roof Sections) SF 0.10 1.10.06 Visual Roof Survey (Multiple Campuses State-wide - All Roof Sections) SF 0.10 1.10.07 Roof core cut (roof by roof) EA NSP 1.10.08 Roof core cut per roof section (all roof sections on campus(s)) EA 150.00 1.11 Comprehensive reporting 1.11.01 Comprehensive report for visual survey (Roof by Roof) EA NSP 1.11.02 Comprehensive report for visual survey(All Roof Sections on Campus(es) EA 100.00 1.11.03 Comprehensive report for each roof section(s) surveyed (Item 1.07) or scanned (Item 1.08) EA 250.00 1,11.04 Comprehensive report enertered into on-line data base for dynamic reporting and tracking all roofing sections on Campus(s) EA NSP 1.12 Manufacturer's Technical Representative Contractor Training Session at Job Start -Up DAILY NSP 1.13 Wind Uplift Testing - Mobilize and provide wind uplift testing per Factory Mutual System Roof Design Manual FM 1-52 EA NSP 1.14 Roof drawings to scale with all rooftop equipment and penetrations 1.14.01 Roof drawings (Roof by Roof) EA NSP 1.14.02 Roof drawings (All Roof Sections on Campus(es) EA 75.00 1.15 Project Building Code Review EA NSP 1.16 Additional and Occasional Services 1.16.01 Project Architect for Design Professional Services HOUR 125.00 1.16.02 Principle Architect for Design Professional Services HOUR 175.00 1.16.03 Project Engineer for Engineering Reviews HOUR 125.00 1.16.04 Principle Architect for Engineering Reviews HOUR 175.00 1,16.06 Roof Consultant HOUR 125.00 1.16.07 Full -Time Job Site Superintendent DAY 600.00 1.16.08 CAD Draftsman HOUR 75.00 1.17 Laboratory Analysis 1.17.01 Laboratory Fungal Analysis: Cultured Fungi Identification & Enumeration (Not including engineering time for sampling) EA 325.00 1.17.02 Laboratory Fungal Analysis: Total Fungi Spore Count (Not including engineering time for sampling) EA 325.00 1.17.03 Laboratory Mold Analysis: Viable Airborne Mold Analysis (Not including engineering time for sampling) I EA 325.00 70 1.17.04 Laboratory Analysis: Viable Surface Swab or Bulk Substrate Analysis (Not including engineering time for sampling) EA 325.00 1.17.05 Laboratory Analysis: Non -Viable Surface Swab or Bulk Substrate Analysis (Not including engineering time for sampling) EA 325.00 1.17.06 Destructive Roof Sample Analysis: Comprehensive laboratory testing of a core sample from an existing roof to include tensile/tear strength, scrim type, interply bitumen weight and roof composition; Repair the roof core area with similar materials. EA NSP 1.18 Travel Expenses 1.18.01 Per Diem - Meals and Incidentals DAY NSP 1.18.02 Lodging DAY NSP 1.18.03 Mileage on Company / Personal Vehicle MILE NSP 1.18.04 Airfare (Economy) JOB NSP 1,18.05 Vehicle Rental DAY NSP 1.19 Seamer Rental Charges DAY NSP 1.20 Set-up Charges for Metal In -Shop Fabrication EA NSP 1.21 Set-up On -Site Roll Forming EA NSP 1.22 Roof Fastener Pull Tests (As Many as Required per Roof Section) EA NSP 1.23 Wind Uplift Design Calculations EA NSP 1.24 Roof Drainage Capacity Calculations EA NSP 1.25 Roof Edge Metal Calculations - ANSI/SPRI ES-1 Standards EA NSP 1.26 Dew Point Calculations EA NSP 1.27 Energy Payback Calculations EA NSP 1.28 Project Life -Cycle Cost Calculation EA NSP 1.29 Substantial Completion Walkthrough with Report and Punchlist EA NSP 1.30 Final Walkthrough with Report EA NSP 1.31 On -Site Quality Control Inspections with Report from Manufacturer's Rep - 3 Days per Week WEEK NSP 1.32 "As -Built" Drawings Upon Project Completion EA NSP 1.33 R.A. or P.E. Reviewed and Stamped Shop Drawings EA NSP 1.34 R.A. or P.E. Reviewed and Stamped Specifications EA NSP 1.35 Non-R.A./P.E. Reviewed Shop Drawings EA NSP 1.36 Project Design Assistance - Hourly Rate for Consultations with Architect of Record EA NSP 1.37 Project Design Assistance - Development of a recommended specification for a roofing or waterproofing project EA NSP 1.38 Roof Asset Management Report with recommended options for future course of actions and associated budgets for capital expense and maintenance planning. EA NSP 1.39 Five year capital expense and maintenance plan ( All roof section on for campus(es)) EA NSP 1.40 Additional ro ess ono Services 1,40.01 Option 1: Professional Services (Third party architectural design, engineering or consulting services quote on corporate letterhead) Cost plus added to quote % 14% 1.40.02 Option 2: R.S. Means or Gordian Group Catalog (Used when professional services line item pricing is not available) Cost plus added to catalog pricing % 14% 2.00. Tear -off &Dispose of Debris -- 2.01 SYSTEM TYPE BUR W/ Insulation and Gravel Surfacing - Metal Deck SF 2.86 2.02 SYSTEM TYPE BUR W/ Insulation and Gravel Surfacing - Wood / Tectum Deck SF 2.86 2.03 SYSTEM TYPE BUR W/ Insulation and Gravel Surfacing - Lightweight / Gyp Deck SF 2.86 2.04 SYSTEM TYPE BUR W/ Insulation and Gravel Surfacing - Concrete Deck SF 2.86 2.05 SYSTEM TYPE BUR W/ Insulation and Mineral Surfacing - Metal Deck SF 2.66 2.06 SYSTEM TYPE BUR W/ Insulation and Mineral Surfacing - Wood / Tectum Deck SF 2.66 2.07 SYSTEM TYPE BUR W/ Insulation and Mineral Surfacing - Lightweight / Gyp Deck SF 2.66 71 SYSTEM TYPE 2.08 BUR Wl Insulation and Mineral Surfacing - Concrete Deck SF 2.66 SYSTEM TYPE 2.09 Single -Ply W/ Insulation - Metal Deck SF 2.16 SYSTEM TYPE 2.10 Single -Ply W1 Insulation - Wood / Tectum Deck SF 2.16 SYSTEM TYPE 2.11 Single -Ply W/ Insulation - Lightweight / Gyp Deck SF 2.16 SYSTEM TYPE 2.12 Single -Ply W/ Insulation - Concrete Deck SF 2.16 SYSTEM TYPE 2.13 Ballasted Single -Ply W/ Insulation - Metal Deck SF 3.10 SYSTEM TYPE 2.14 Ballasted Single -Ply W/ Insulation - Wood / Tectum Deck SF 3.10 SYSTEM TYPE 2.15 Ballasted Single -Ply W/ Insulation - Lightweight / Gyp Deck SF 3.10 SYSTEM TYPE 2.16 Ballasted Single -Ply W/ Insulation - Concrete Deck SF 3.10 SYSTEM TYPE 2.17 Coal Tar BUR W/ Insulation and Gravel Surfacing - Metal Deck SF 3.19 SYSTEM TYPE 2.18 Coal Tar BUR W/ Insulation and Gravel Surfacing - Wood / Tectum Deck SF 3.19 SYSTEM TYPE 2.19 Coal Tar BUR W/ Insulation and Gravel Surfacing - Lightweight / Gyp Deck SF 3.19 SYSTEM TYPE 2.20 Coal Tar BUR W/ Insulation and Gravel Surfacing - Concrete Deck SF 3.19 SYSTEM TYPE 2.21 Coal Tar BUR W/ Insulation and Mineral Surfacing - Metal Deck SF 3.00 SYSTEM TYPE 2.22 Coal Tar BUR W/ Insulation and Mineral Surfacing - Wood / Tectum Deck SF 3.00 SYSTEM TYPE 2.23 Coal Tar BUR W/ Insulation and Mineral Surfacing - Lightweight / Gyp Deck SF 3.00 SYSTEM TYPE 2.24 Coal Tar BUR W/ Insulation and Mineral Surfacing - Concrete Deck SF 3.00 SYSTEM TYPE 2.25 Metal Roofing System - Metal Deck SF 2.88 SYSTEM TYPE 2.26 Metal Roofing System - Wood / Tectum Deck SF 2.88 SYSTEM TYPE 2.27 Metal Roofing System - Lightweight / Gypsum Deck SF 2.88 SYSTEM TYPE 2.28 Metal Roofing System - Concrete Deck SF 2.88 SYSTEM TYPE 2.29 Dimensional/Architectural Shingle Roof -Wood Deck SF 1.16 SYSTEM TYPE 2.30 3-Tab Shingle Roof -Wood Deck SF 1.16 SYSTEM TYPE 2.31 Clay Tile Shingle Roof -Wood Deck SF 3.11 SYSTEM TYPE 2.32 Concrete Tile Shingle Roof - Wood Deck SF 3.11 SYSTEM TYPE 2.33 Slate Tile Shin le Roof - Wood Deck SF 3.53 SYSTEM TYPE 2.34 Cedar / Wood Shake Shingle Roof - Wood Deck SF 3.11 SYSTEM TYPE 2.35 Add to save good Clay Tile Shingles for reuse SF 0.90 72 SYSTEM TYPE 2.36 Add to save good Concrete Tile Shingles for reuse SF 0.90 SYSTEM TYPE 2.37 Add to save good Slate Tile Shingles for reuse SF 0.90 SYSTEM TYPE 2.38 Add to save good Cedar / Wood Shake Shingles for reuse SF 1.87 SYSTEM TYPE 2.39 Polyurethane Foam (PUF) Roof (Average of 2" thick) W/ Underlying Insulation and UV -Resistant Coating - Metal Deck SF 3.02 SYSTEM TYPE Polyurethane Foam (PUF) Roof (Average of 2" thick) W/ Underlying Insulation and UV -Resistant Coating - Wood ! 2.40 Tectum Deck SF 3.02 SYSTEM TYPE Polyurethane Foam (PUF) Roof (Average of 2" thick) W/ Underlying Insulation and UV -Resistant Coating - Lightweight / 2.41 Gyp Deck SF 3.02 SYSTEM TYPE Polyurethane Foam (PUF) Roof (Average of 2" thick) W/ Underlying Insulation and UV -Resistant Coating - Concrete 2.42 Deck SF 3.02 SYSTEM TYPE 2.43 Add of Each Additional Average Depth 1" of Polyurethane Foam (PUF) Roofing SF 1.15 SYSTEM TYPE 2.44 BUR w/ Gravel Surfacing to the Existing Insulation (Insulation to be Re -Used) SF 2.88 SYSTEM TYPE 2.45 BUR w/ Mineral Surfacing to the Existing Insulation (Insulation to be Re -Used) SF 2.86 SYSTEM TYPE 2.46 Single -Ply to the Existing Insulation (Insulation to be Re -Used SF 2.32 SYSTEM TYPE 2.47 Ballasted Single -Ply to the Existing Insulation (Insulation to be Re -Used SF 1.80 SYSTEM TYPE 2.48 Coal Tar BUR with Gravel Surfacing to the Existing Insulation (Insulation to be Re -Used) SF 3.34 SYSTEM TYPE 2.49 Coal Tar BUR with Mineral Surfacing to the Existing Insulation (Insulation to be Re -Used) SF 3.34 MULTIPLIER -TEAR-OFF & DISPOSE OF DEBRIS 2.99 Each Additional Roof System % 38.00 3.00 " " Removal & Replacernerif of,Roof Deck DECK TYPE 3.01 Spot Metal Deck Replacement Multiple areas under 1 square) SF 16.68 DECK TYPE 3.02 Spot Wood Deck Replacement (Multiple areas under 1 square) SF 15.26 DECK TYPE 3.03 Spot Gypsum Deck Replacement (Multiple areas under 1 square) SF 48.66 DECK TYPE 3.04 Spot Concrete Deck Replacement Multiple areas under 1 square SF 37.30 DECK TYPE 3.05 Spot Lightweight Deck Replacement (Multiple areas under 1 square) SF 21.61 DECK TYPE 3.06 Spot Tectum Deck Replacement (Multiple areas under 1 square) SF 20.70 DECK TYPE 3.07 Large Areas of Metal Deck Replacement (Replacement areas averaging greater than 1 square) SF 10.36 DECK TYPE 3.08 Large Areas of Wood Deck Replacement (Replacement areas averaging greater than 1 square) SF 10.98 DECK TYPE 3.09 Large Areas of Gypsum Deck Replacement (Replacement areas averaging greater than 1 square) SF 39.89 DECK TYPE 3.10 Large Areas of Concrete Deck Replacement (Replacement areas averaging greater than 1 square) SF 30.56 DECK TYPE 3.11 Large Areas of Lightweight Deck Replacement (Replacement areas averaging greater than 1 square) SF 16.25 73 DECK TYPE 3.12 Large Areas of Tectum Deck Replacement (Replacement areas averaging greater than 1 square) SF 16.56 4.00 Insulation Recovery ;Board & Insulations Options RECOVERY BOARD TYPE 1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Adhered in Hot ASTM D 312 Type III or IV Asphalt; 4.01 Mopped SF 1.06 RECOVERY BOARD TYPE 4.02 1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Adhered with Insulation Adhesive SF 2.01 RECOVERY BOARD TYPE 4.03 1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Metal Deck SF 1.07 RECOVERY BOARD TYPE 1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Wood / Tectum 4.04 Deck SF 1.15 RECOVERY BOARD TYPE 1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Lightweight / 4.05 Deck SF 1.17 _Gypsum RECOVERY BOARD TYPE 4.06 1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Concrete Deck SF 1.21 RECOVERY BOARD TYPE 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck ! Securock / Equal) Installed Over an Existing 4.07 Roof Adhered in Hot ASTM D 312 Type III or IV Asphalt; Mopped SF 1.83 RECOVERY BOARD TYPE 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing 4.08 Roof Adhered with Insulation Adhesive SF 2.69 RECOVERY BOARD TYPE 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing 4.09 Roof Mechanically Fastened to Roof Deck - Metal Deck SF 1.86 RECOVERY BOARD TYPE 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing 4.10 Roof Mechanically Fastened to Roof Deck - Wood / Tectum Deck SF 2.04 RECOVERY BOARD TYPE 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing 4.11 Roof Mechanically Fastened to Roof Deck - Lightweight / Gypsum Deck SF 2.07 RECOVERY BOARD TYPE 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing 4.12 Roof Mechanically Fastened to Roof Deck - Concrete Deck SF 2.14 ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF) Install 1.0" of Polyisocyanurate Insulation Over an Existing Roof. All Wet Insulation Must be Replaced Prior to Installation 4.13 of New Course of Insulation SF 1.97 ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF) Install 1.5" of Polyisocyanurate Insulation Over an Existing Roof. All Wet Insulation Must be Replaced Prior to Installation 4.14 of New Course of Insulation SF 2.13 ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF) Install 2.0" of Polyisocyan u rate Insulation Over an Existing Roof. All Wet Insulation Must be Replaced Prior to Installation 4.15 lof New Course of Insulation SF 2.49 ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF) Install 2.5" of Polyisocyanu rate Insulation Over an Existing Roof. All Wet Insulation Must be Replaced Prior to Installation 4.16 of New Course of Insulation SF 2.87 ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF) 4.17 Add for Cutting New Insulation to Match the Profile of an Existing Metal Roof. SF 1.43 INSULATION SUBSTITUTION OPTION Deduct for Providing an R-Value of greater than or equal to 10, but less than 15; instead of the Standard R-Value of 20 4.18 (Should be Negatively Priced) - All Applications Other Than Metal Roof Systems SF -0.60 74 INSULATION SUBSTITUTION OPTION Deduct for Providing an R-Value of greater than or equal to 15, but less than 18; instead of the Standard R-Value of 20 4.19 (Should be Negatively Priced) - All Applications Other Than Metal Roof Systems SF -0.36 INSULATION SUBSTITUTION OPTION: Deduct for Providing an R-Value of greater than or equal to 18, but less than 20 instead of the Standard R-Value of 20 4.20 (Should be Negatively Priced) - All Applications Other Than Metal Roof Systems SF -0.17 INSULATION SUBSTITUTION OPTION: Add for Providing an R-Value of 25 Instead of the Standard R-Value of 20 - All Applications Other Than Metal Roof 4.21 Systems SF 0.64 INSULATION SUBSTITUTION OPTION: Add for Providing an R-Value of 30 Instead of the Standard R-Value of 20 - All Applications Other Than Metal Roof 4.22 Systems SF 1.30 INSULATION SUBSTITUTION OPTION Substitute 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) in Place of the 4.23 lWood Fiber or Perlite - Adhered in Hot ASTM D 312 Type III or IV Asphalt; Mopped SF 1 0.77 INSULATION SUBSTITUTION OPTION Substitute 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock I Equal) in Place of the 4.24 Wood Fiber or Perlite - Adhered with Insulation Adhesive SF 0.77 INSULATION SLOPE OPTION Provide a 1/4" Tapered Polyisocyanurate Insulation System while Maintaining the Average R-Value Including Tapered 4.25 Crickets; Adhered in ASTM D 312 Type III or IV Hot Asphalt; Mopped SF 7.29 INSULATION SLOPE OPTION Provide a 1/8" Tapered Polyisocyanurate Insulation System while Maintaining the Average R-Value; Adhered in ASTM D 4.26 312 Type III or IV Hot Asphalt; Mopped SF 5.21 INSULATION SLOPE OPTION Provide a 1/4" Tapered Polyisocyanurate Insulation System while Maintaining the Average R-Value Including Tapered 4.27 Crickets; Adhered with Insulation Adhesive SF 11.82 INSULATION SLOPE OPTION Provide a 1/8" Tapered Polyisocyanurate Insulation System while Maintaining the Average R-Value; Adhered with 4.28 Insulation Adhesive SF 8.30 INSULATION SUBSTITUTION OPTION 4.29 Provide a 1/4" Tapered Insulating Lightweight Concrete System while Maintaining Average R-Value SF 10.89 INSULATION SUBSTITUTION OPTION 4.30 Provide a 1/8" Tapered Insulating Lightweight Concrete System while Maintaining Average R-Value SF 10.10 INSULATION ATTACHMENT OPTION: 4.31 Provide Attachment Pattern in Compliance with FM 1-60 Wind Uplift Instead of FM 1-90 SF -0.04 INSULATION ATTACHMENT OPTION: 4.32 Provide Attachment Pattern in Compliance with FM 1-120 Wind Uplift Instead of FM 1-90 SF 0.21 5.00�, Coat`NewRogfing With El astomeric.Coating ROOF SYSTEM TYPE Apply an Acrylic Coating per Specifications (1.5 Gallons per Square per Coat - 2 Coats Required) - Mineral -Surfaced 5.01 Modified Roof SF 4.16 ROOF SYSTEM TYPE Apply an Acrylic Coating per Specifications (1.0 Gallon per Square per Coat - 2 Coats Required) - Smooth -Surfaced 5.02 Modified Roof SF 3.24 ROOF SYSTEM TYPE Apply a bright white, water -based, acrylic -urethane hybrid roof coating per Specifications (1.5 Gallons per Square per 5.03 Coat - 2 Coats Required) - Mineral -Surfaced Modified Roof SF 5.55 ROOF SYSTEM TYPE Apply a bright white, water -based, acrylic -urethane hybrid roof coating per Specifications (1.0 Gallon per Square per Coat 5.04 - 2 Coats Required) - Smooth -Surfaced Modified Roof SF 1 4.13 ROOF SYSTEM TYPE Apply an Acrylic base coat and a PVDF top coat per Specifications (1.5 Gallons per Square Base Coat - 1/2 Gallon per 5.05 Square Top Coat) - Mineral -Surfaced Modified Roof SF 5.15 75 ROOF SYSTEM TYPE Apply an Acrylic base coat and a PVDF top coat per Specifications (1 Gallon per Square Base Coat - 1/2 Gallon per 5.06 Square Top Coat) -Smooth-Surfaced Modified Roof SF 4.53 ROOF SYSTEM TYPE Apply an Urethane Coating per Specifications (1 Gallon per Square per Coat - 2 Coats Required) - Smooth or Mineral 5.07 Surfaced Modified; With Reinforced Seams (Base Coat Seam with 1.5 Gallons per Square & Reinforcement) SF 9.63 ROOF SYSTEM TYPE Apply a single -component, aliphatic, polyurea liquid adhesive per Specifications (Apply 1.0 gallon per Square on Seams & wait 24 Hours / Apply base coat at 1.0 gallon per Square / broadcast mineral at 35 lbs. per Square or white gravel at 5.08 200 lbs. per Square / wait 24 hours and apply top coat at 1.0 gallon per Square - Mineral -Surfaced Modified SF 8.30 ROOF SYSTEM TYPE Apply a single -component, aliphatic, polyurea liquid adhesive per Specifications (apply base coat at 1.0 gallon per Square / broadcast mineral at 35 lbs. per Square or white gravel at 200 lbs. per Square / wait 24 hours and apply top 5.09 coat at 1.0 gallon per Square - Smooth -Surfaced Modified SF 8.30 ROOF SYSTEM TYPE Apply an Aluminum Coating per Specifications (3/4 Gallon per Square per Coat - 2 Coats Required) - Smooth or Mineral 5.10 Surfaced Modified SF 2.25 ROOF SYSTEM TYPE Apply a Fibered Aluminum Coating per Specifications (2 Gallons per Square per Coat - 1 Coat Required) - Smooth or 5.11 IMIneral Surfaced Modified SF 2.74 6.00 Roof Deck and Insulation O t Y== =Y 6. METAL ROOF DECK- HOT APPLICATION'=ASTM D"312 T,YPE`llIFOR'IV ASPHALT Mechanically Fasten Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20 In Compliance with FM 1-90 6.01.01 INSULATION OPTION: Requirements SF 4.05 6.02 WOOD ROOF DECK - HOT APPLICATION - ASTM D 312 TYPE III OR IV ASPHALT Mechanically Fasten Polyisocyanurate / Hot Mop Wood Fiber or Perlite to 6.02.01 INSULATION OPTION: Provide an Average R-Value of 20 SF 3.82 Without Insulation - Must Include Rosin & Mechanically Fasten Glass Base 6.02.02 INSULATION OPTION: Sheet SF 1.32 3 TECTUM ROOF DECK - HOT APPLICATION - ASTM D 312 TYPE III OR IV ASPHALT Mechanically Attach Base Sheet Utilizing FM 1-90 Attachment Patterns & Hot Mop Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value 6.03.01 INSULATION OPTION: of 20 SF 6.62 Without Insulation - Must Include Rosin & Mechanically Fasten Glass Base 6.03.02 INSULATION OPTION: Sheet SF 1.92 LIGHTWEIGHT CONCRETE / GYPSUM ROOF DECK- HOT APPLICATION - ASTM D 312 TYPE III OR IV ASPHALT Must Mechanically Attach a Base Sheet; Hot Mop Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20 6.04.01 INSULATION OPTION: In Compliance FM 1-90 Requirements SF 6.62 Without Insulation - Must at Least Mechanically Fasten a Base Sheet to the Roof Deck Prior to Installation Installed with FM 1-90 Attachment 6.04.02 INSULATION OPTION: 1 Patterns SF 1.92 CONCRETE ROOF DECK - HOT APPLICATION - ASTM D 312 TYPE III OR IV ASPHALT Prime Roof Deck; Hot Mop Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20 6,05.01 INSULATION OPTION: In Compliance FM 1-90 Requirements SF 4.44 76 Without Insulation - Prime Roof Deck; Must at Least 1/2" Wood Fiber or Perlite Hot Mopped to Deck 6.05.02 INSULATION OPTION: In Compliance FM 1-90 Requirements SF 1.15 TUr- METAL ROOF DECK - COLD PROCESS APPLICATION Mechanically Fasten Polyisocyanurate Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to Provide an Average R-Value of 20 6.06.01 INSULATION OPTION: In Compliance FM 1-90 Requirements SF 4.52 6.07 WOOD ROOF DECK - COLD PROCESS APPLICATION Mechanically Fasten Polyisocyanurate / Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to 6.07,01 INSULATION OPTION: Provide an Average R-Value of 20 SF 4.52 Without Insulation - Must Include Rosin & Mechanically Fasten Glass Base 6.07.02 INSULATION OPTION: Sheet SF 1.32 TO- TECTUM ROOF DECK - COLD PROCESS APPLICATION Mechanically Attach Base Sheet & Adhere Polyisocyanurate in Insulation Adhesive / Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to Provide an Average R-Value 6.08.01 INSULATION OPTION: of 20 SF 9.04 Without Insulation - Must Include Rosin & Mechanically Fasten Glass Base 6.08.02 INSULATION OPTION: Sheet SF 1.93 . 9 LIGHTWEIGHT CONCRETE ! GYPSUM ROOF DECK- COLD PROCESS APPLICATION Must Mechanically Attach a Base Sheet; Adhere Polyisocyanurate in Insulation Adhesive / Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to Provide an Average R-Value of 20 6.09.01 INSULATION OPTION: In Compliance FM 1-90 Requirements SF 9.04 Without Insulation - Must at Least Mechanically Fasten a Base Sheet to the Roof Deck Installed with FM 1-90 Attachment 6.09.02 INSULATION OPTION: Patterns SF 1.93 FTr,, -�.- CONCRETE R0QFRECK -COLD, PROCESS APPIL CATION Adhere Polyisocyanurate in Insulation Adhesive / Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to Provide an Average R-Value of 20 6.10.01 INSULATION OPTION: In Compliance FM 1-90 Requirements SF 6.69 Without Insulation - Must at Least 1/2" High Density Asphalt Coated Wood Fiber Adhered with Insulation Adhesive to Deck 6.10.02 INSULATION OPTION: In Compliance FM 1-90 Requirements SF 1.68 61f , MET ALROOF'DECK-TORCH�APPLIEDTSELF-ADHERINGAPPLICATION Mechanically Fasten Polyisocya n u rate / Adhere Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value of 20 6.11.01 INSULATION OPTION: In Compliance FM 1-90 Requirements SF 5.33 612 WOOD ROOF} }DECK.= TORCH,APPLIED / SELF -ADHERING- - ;LIGATION 77 Mechanically Fasten Polyisocyanurate / Adhere Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value 6.12.01 INSULATION OPTION: of 20 SF 5.33 Without Insulation - Must Mechanically Attach 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / 6.12.02 INSULATION OPTION: ISecurock / Equal) I SF 1.33 6.13 TECTUM ROOF DECK -TORCH APPLIED / SELF -ADHERING APPLICATION Mechanically Attach Base Sheet & Adhere Polyisocyanurate in Insulation Adhesive / Adhere Treated Gypsum Insulation Board with Glass -Mat (e,g, DensDeck / Securock / Equal) with Insulation Adhesive to Provide an 6.13.01 INSULATION OPTION: Average R-Value of 20 SF 9.90 Without Insulation - Must Mechanically Attach 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / 6.13.02 INSULATION OPTION: Securock / Equal) SF 1.96 674 LIGHTWEIGHT CONCRETE / GYPSUM ROOF DECK - TORCH APPLIED / SELF•ADHERING APPLICATION 7- Must Mechanically Attach a Base Sheet; Adhere Polyisocyanurate in Insulation Adhesive / Adhere Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value of 20 6.14.01 INSULATION OPTION: In Compliance FM 1-90 Requirements SF 9.90 Without Insulation - Must at Least Mechanically Fasten a Base Sheet to the Roof Deck Prior to Installation Installed with FM 1-90 Attachment 6.14.02 INSULATION OPTION: I Patterns SF 1.99 CONCRETE ROOF DECK - TORCH APPLIED 9 SELF -ADHERING APPLICATION Adhere Polyisocyanu rate in Insulation Adhesive / Adhere Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value of 20 6.15.01 INSULATION OPTION: In Compliance FM 1-90 Requirements SF 7.42 Without Insulation - Must Adhere 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) in Insulation Adhesive 6.15.02 INSULATION OPTION: In Compliance FM 1-90 Requirements SF 2.22 6.11V- INSTALL PRIOR TO ROOF SYSTEM INSULATION:, HOT ASPHALT -APPLIED VAPOR BARRIER ON METAL DECK: Mechanically -Fasten Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal), Apply 2 Plies of Glass Felt in Hot ASTM D 312 Type III OR IV Asphalt In Compliance with FM 1-90 6.16.01 f VAPOR BARRIER OPTION: Requirements SF 3.00 78 HOT ASPHALT -APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, Apply 2 Plies of Glass Felt in Hot ASTM D 312 Type III OR IV Asphalt In Compliance with FM 1-90 6.16.02 VAPOR BARRIER OPTION: Requirements SF 3.10 HOT ASPHALT -APPLIED VAPOR BARRIER ON CONCRETE DECK: Prime Deck Prior to Applying 2 Plies of Glass Felt in Hot ASTM D 312 Type III 6.16.03 VAPOR BARRIER OPTION: OR IV Asphalt SF 2.07 COLD ASPHALT -APPLIED VAPOR BARRIER ON METAL DECK: Mechanically -Fasten Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal); Apply 2 Plies of Glass Base in Cold Process Modified Asphalt In Compliance with FM 1-90 6.16.04 VAPOR BARRIER OPTION: Requirements SF 4.74 COLD ASPHALT -APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, Apply 2 Plies of Glass Base in Cold Process Modified Asphalt In Compliance with FM 1-90 6.16.05 VAPOR BARRIER OPTION: Requirements SF 4,74 COLD ASPHALT -APPLIED VAPOR BARRIER ON CONCRETE DECK: Prime Deck Prior to Applying 2 Plies of Glass Base in Cold Process Modified 6.16.06 VAPOR BARRIER OPTION: Asphalt SF 3.68 TORCH -APPLIED VAPOR BARRIER ON METAL DECK: Mechanically -Fasten Treated Gypsum Insulation Board with Glass -Mat (e,g. DensDeck / Securock / Equal); Heat Weld with Torch 1 Ply of SBS Modified Asphalt -Based, Fiberglass Reinforced Torch Base Sheet - Minimum of 80 Ibf/in tensile Torch -Applied Base Sheet (ASTM D 5147) In Compliance with FM 1-90 6.16.07 VAPOR BARRIER OPTION: Requirements SF 5.21 TORCH -APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, Heat Weld with Torch 1 Ply of SBS Modified Asphalt -Based, Fiberglass Reinforced Torch Base Sheet - Minimum of 80 Ibf/in tensile Torch -Applied Base Sheet (ASTM D 5147) In Compliance with FM 1-90 6.16.08 VAPOR BARRIER OPTION: Requirements SF 5.38 79 TORCH -APPLIED VAPOR BARRIER ON CONCRETE DECK: Prime Deck Prior to Heat Welding with Torch 1 Ply of SBS Modified Asphalt - Based, Fiberglass Reinforced Torch Base Sheet - Minimum of 80 Ibf/in tensile Torch -Applied Base Sheet (ASTM D 6.16.09 VAPOR BARRIER OPTION: 5147) SF 4.31 HOT ASPHALT -APPLIED VAPOR BARRIER ON METAL DECK: Mechanically -Fasten Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal), ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 Ibf/in tensile in Hot ASTM D 312 Type III OR IV Asphalt In Compliance with FM 1-90 6.16.10 VAPOR BARRIER OPTION: Requirements SF 3.99 HOT ASPHALT -APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type 1 - 70 Ibf/in tensile in Hot ASTM D 312 Type III OR IV Asphalt In Compliance with FM 1-90 6.16.11 VAPOR BARRIER OPTION: Requirements SF 4.29 HOT ASPHALT -APPLIED VAPOR BARRIER ON CONCRETE DECK: Prime Deck Prior to ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 Ibf/in tensile in Hot ASTM D 312 Type III 6.16.12 VAPOR BARRIER OPTION: OR IV Asphalt SF 3.15 COLD ASPHALT -APPLIED VAPOR BARRIER ON METAL DECK: Mechanically -Fasten Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal); ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 Ibf/in tensile in Cold Process Modified Asphalt In Compliance with FM 1-90 6.16,13 VAPOR BARRIER OPTION: Requirements SF 4.93 COLD ASPHALT -APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type 1 - 70 Ibf/in tensile in Cold Process Modified Asphalt In Compliance with FM 1-90 6.16.14 VAPOR BARRIER OPTION: Requirements SF 4.91 80 COLD ASPHALT -APPLIED VAPOR BARRIER ON CONCRETE DECK: Prime Deck Prior to ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 Ibf/in tensile in Cold Process Modified 6.16.15 VAPOR BARRIER OPTION: Asphalt SF 3.85 BUILT-UP D FIED F WITH FLOOD COATAND AGGREGATE IN 7.00 HOT ASTM ID 312 TYPE III OR IV ASPHALT. ` ROOF CONFIGURATION 7.01 2 Plies of Glass Felt, Cap Sheet, Flood Coat and Aggregate All In Hot ASTM D 312 Type III OR IV Asphalt' ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 Ibf/in 7.01.01 ROOFING MEMBRANE OPTION: tensile SF 6.12 ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 Ibf/in 7.01.02 ROOFING MEMBRANE OPTION: tensile SF 7.38 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 Ibf/in 7.01.03 ROOFING MEMBRANE OPTION: tensile SF 7.29 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 Ibf/in 7.01,04 ROOFING MEMBRANE OPTION: tensile SF 8.40 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 Ibf/in 7.01.05 ROOFING MEMBRANE OPTION: tensile SF 8.86 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 7.00 Must includes coverage for roof uplift 7.02 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar 7.03 WARRANTY UPCHARGE: Limitations SF NSP Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 7.04 WARRANTY UPCHARGE: Limitations SF NSP-1 Add to provide coverage for roof uplift 7.05 WARRANTY UPCHARGE: pressures up to 120 MPH SF NSP-2 DEDUCT TO SQUARE FOOT COST - Hot Applied Modified BUR Substitute Additional Glass Felt (Hot Applications) in Place of ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 7.06 Minimum of 70 Ibf/in tensile (i.e. 3 Ply BUR) SF 2.28 ADD TO PER SQUARE FOOT COST - Hot Applied Modified BUR 7.07 Each Additional Glass Felt (Hot Applications) Inter -ply Installed SF 0.82 BU LT UP MOD F ED ROOF WITH FLOOD COAT AND AGGREGATE N COLD DROSS ASPIAT0.3. ROOF�CO,�FIGURATION� L p q ��k t'� � �"WIN��i 8.01 �'` 2 Pliesof Glass Base;CapSheet, Flood "Coat and Aggregate'Ail irr GoliJ Process Mollified Asphalt ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 Ibf/in 8.01.01 ROOFING MEMBRANE OPTION: tensile SF 10.08 ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 Ibf/in 8.01.02 ROOFING MEMBRANE OPTION: tensile SF 1 11.49 81 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 Ibf/in 8.01.03 ROOFING MEMBRANE OPTION: tensile SF 11.41 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 Ibf/in 8.01.04 ROOFING MEMBRANE OPTION: tensile SF 12.51 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 Ibf/in 8.01.05 ROOFING MEMBRANE OPTION: tensile SF 12.96 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 8,00 Must includes coverage for roof uplift 8.02 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar 8.03 WARRANTY UPCHARGE: Limitations SF NSP Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 8.04 WARRANTY UPCHARGE: Limitations SF NSP-1 Add to provide coverage for roof uplift 8.05 WARRANTY UPCHARGE: pressures up to 120 MPH SF NSP-2 DEDUCT TO SQUARE FOOT COST - Cold Applied Modified BUR Substitute Additional Glass Base Sheet in Place of ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 8.06 70 Ibf/in tensile (i.e. 3 Ply BUR) SF -1.25 ADD TO PER SQUARE FOOT COST - Cold Applied Modified BUR 8.07 Each Additional Glass Base (Cold Applications) Inter -ply Installed SF 1.88 BUILT-UP MODIFIED'ROOFADHEEGATE RED IN HOT ASTM D;312 TYPE) OR IV . ASPHALT,- FLO"COAT & AGGRIN.MODIFIED COALTAR PITC OD H ROOF ONFI RATION 9.01 2 ply of Glass Felt, Cap Sheet, Set In Hot Asphalt, Flood Coat in Modified Coal Tar Pitch and Aggregate ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 Ibf/in tensile, Flood Coat in Modified Hot Coal 9.01.01 ROOFING MEMBRANE & COATING OPTION: Tar Pitch With 2000% Elongation SF 8.92 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 Ibf/in tensile, Flood Coat in Modified Hot Coal 9.01.02 ROOFING MEMBRANE & COATING OPTION Tar Pitch With 2000% Elongation SF 10.18 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 Ibf/in tensile, Flood Coat in Modified Hot Coal 9.01.03 ROOFING MEMBRANE & COATING OPTION Tar Pitch With 2000% Elongation SF 10.11 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 Ibf/in tensile, Flood Coat in Modified Hot Coal 9.01.04 ROOFING MEMBRANE & COATING OPTION Tar Pitch With 2000% Elongation SF 11.21 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 600 Ibf/in tensile, Flood Coat in Modified Hot Coal Tar 9.01.05 ROOFING MEMBRANE & COATING OPTION Pitch With 2000% Elongation SF 11.67 82 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 9.00 Must includes coverage for roof uplift 9.02 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar 9.03 WARRANTY UPCHARGE: Limitations SF NSP Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 9.04 WARRANTY UPCHARGE: Limitations SF NSP-1 Add to provide coverage for roof uplift 9.05 WARRANTY UPCHARGE: pressures up to 120 MPH SF NSP-2 Add/Deduct for Installing Flood Coat in 9.06 COATING OPTION: Cold Process Coal Tar Pitch SF -0.56 BUILT-UP MODIFIED _R OF'W TH MINERAL CAP; H ET -A HERED IN, 10.00 HOT A§TM D •312 TYPE 111 'OR IV ASPHALT, ROOF CONFIGURATION .• . _ .. _; -. _ 10.01 2 ply of Glass Felt, Mineral Surfaced Cap Sheet, SetIn Hot ASTM D 312 Type 111 or IV Asphalt ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 Ibf/in 10,01.01 ROOFING MEMBRANE OPTION: tensile SF 5.06 ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 Ibf/in 10.01.02 ROOFING MEMBRANE OPTION: tensile SF 6.63 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 Ibf/in 10.01.03 ROOFING MEMBRANE OPTION: tensile SF 6.03 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 Ibf/in 10.01.04 ROOFING MEMBRANE OPTION: tensile SF 7.63 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 Ibf/in 10.01.05 ROOFING MEMBRANE OPTION: tensile SF 8.37 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 10.00 Must includes coverage for roof uplift 10.02 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Labor & Material Warranty with No Dollar 10.03 WARRANTY UPCHARGE: Limitations SF NSP-3 Labor & Material Warranty with No Dollar 10.04 WARRANTY UPCHARGE: Limitations SF NSP-1 Add o provide coverage for roof upliTF- 10.05 WARRANTY UPCHARGE: pressures up to 120 MPH SF NSP-2 I 4 I 1 L S Y 11 00 x.. COLD PROCESS A1SPHALT' ROOF CONFIGURATION 11.01 2 ply Glass Base, Mineral Cap Sheet, Set in Cold Process' Modified Asphalt 83 ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 Ibf/in 11.01.01 ROOFING MEMBRANE OPTION: tensile SF 7.84 ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 Ibf/in 11.01.02 ROOFING MEMBRANE OPTION: tensile SF 9.40 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 Ibf/in 11.01.03 ROOFING MEMBRANE OPTION: tensile SF 8.79 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 Ibf/in 11.01.04 ROOFING MEMBRANE OPTION: tensile SF 10.39 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 Ibf/in 11.01.05 ROOFING MEMBRANE OPTION: tensile SF 11.14 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 11.00 Must includes coverage for roof uplift 11.02 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Labor & Material Warranty with No Dollar 11.03 WARRANTY UPCHARGE: Limitations SF NSP-3 Labor & Material Warranty with No Dollar 11.04 WARRANTY UPCHARGE: Limitations SF NSP-1 Add o provide coverage for root uplift 11.05 WARRANTY UPCHARGE: pressures up to 120 MPH SF NSP-2 2-PLY ROOF SYSTEMS - COMBINATIONS OF A BASE PLY & A CAP SHEET (TOP PLY) PLEASE NOTE: BASE PLY & CAP SHEET COMBINATIONS MUST BE 12.00 APPROVED BY THE MANUFACTURER ROOF CONFIGURATION 12.01 1 Ply Modified Base Sheet Adhered in Hot ASTM D 312 Type III or IV Asphalt ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet 12.01.01 BASE PLY OPTION: Material Type I - 70 Ibf/in tensile SF 2.81 ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet 12.01.02 BASE PLY OPTION: Material Type III - 220 Ibf/in tensile SF 3.56 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet 12.01.03 BASE PLY OPTION: Material Type III - 310 Ibf/in tensile SF 3.71 ADD/DEDUCT TO PER SQUARE FOOT COST - Hot Applied Modified Multi -ply Systems Each Additional Modified Base Sheet (All Hot Applications) Installed. To be combined with line items above for a labor cost reduction to installed price of two plies of the same modified base sheet vs. the installation of a single base sheet 12.01.04 (i.e. 12.01.02 + 12.01.02 + 12.01.04 = Two Plies Installed) SF -0.33 ROOF CONFIGURATION 12.02 1 Ply Modified Base Sheet Adhered In Cold Process Modified Asphalt ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet 12.02.01 BASE PLY OPTION: Material Type 1- 70 Ibf/in tensile SF 3.53 ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet 12.02.02 BASE PLY OPTION: Material Type III - 220 Ibf/in tensile SF 4.29 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet 12.02.03 BASE PLY OPTION: Material Type III - 310 Ibf/in tensile SF 4.44 84 ADD/DEDUCT TO PER SQUARE FOOT COST - Cold Applied Modified Multi -ply Systems Each Additional Modified Base Sheet (All Cold Applications) Installed. To be combined with line items above for a labor cost reduction to installed price of two plies of the same modified base sheet vs. the installation of a single base sheet 12.02.04 (i.e. 12.02.02 + 12.02.02 + 12.02.04 = Two Plies Installed) SF -0.38 Add/Deduct for Cold Applied Modified Multi -ply Systems Substitute Cold Process Adhesive with 12.02.05 INTERPLY ADHESIVE OPTION: Alternative Solvent Free Adhesive SF 1.89 ROOF CONFIGURATION 12.03 1 Ply of Torch Base Sheet Installed with Torch Application SBS Modified Asphalt -Based, Fiberglass Reinforced Torch Base Sheet - Minimum of 80 Ibflin tensile Torch -Applied Base 12.03.01 BASE PLY OPTION: Sheet (ASTM D 5147) SF 3.13 ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet 12.03.02 BASE PLY OPTION: Material Type III - 210 Ibf/in tensile SF 4.16 ADD/DEDUCT TO PER SQUARE FOOT COST - Torch -Applied Modified Multi -ply Systems Each Additional Modified Base Sheet (All Torch -Applied Applications) Installed. To be combined with line items above for a labor cost reduction to installed price of two plies of the same modified base sheet vs. the installation of a single 12.03.03 base sheet (i.e. 12.03.02 + 12.03.02 + 12.03.03 = Two Plies Installed) SF -0.21 ROOF CONFIGURATION , 12.04 1'Ply of Self -Adhering Base Installed Using Self -Adhering Backing SBS Modified Asphalt -Based, Polyester OR Fiberglass/Polyester OR Fiberglass Reinforced Self -Adhering Base Sheet - 12.04.01 BASE PLY OPTION: Minimum of 50 Ibf/in tensile SF 3.20 ADD/DEDUCT TO PER SQUARE FOOT COST - Torch -Applied Modified Multi -ply Systems Each Additional Modified Base Sheet (All Torch -Applied Applications) Installed. To be combined with line items above for a labor cost reduction to installed price of two plies of the same modified base sheet vs. the installation of a single 12.04.02 base sheet (i.e. 12.04.01 + 12.04.01 + 12.04.02 = Two Plies Installed) SF -0.21 ROOF CONFIGURATION t 12.05 1 Ply Cap Sheet, Flood Coat and Aggregate Adhered In Hot ASTM D 312 Type III OR IV Asphalt ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 Ibf/in 12.05.01 ROOFING MEMBRANE OPTION: tensile SF 3.53 ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 Ibf/in 12.05.02 ROOFING MEMBRANE OPTION: tensile SF 4.93 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 Ibf/in 12.05.03 ROOFING MEMBRANE OPTION: tensile SF 4.85 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III — Minimum of 500 Ibf/in 12.05.04 ROOFING MEMBRANE OPTION: tensile SF 5.96 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III — Minimum of 600 Ibf/in 12.05.05 ROOFING MEMBRANE OPTION: tensile SF 6.42 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.05 Must includes coverage for roof uplift 12.05.06 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Add to provide coverage for a 25 Year :ZT Labor & Material Warranty with No Dollar WARRANTY UPCHARGE: Limitations SF NSP 85 Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 12,05.08 WARRANTY UPCHARGE: Limitations SF NSP-1 Add to provide coverage for roof uplift 12.05.09 WARRANTY UPCHARGE: pressures up to 120 MPH SF NSP-2 ROOF CONFIGURATION 12.06 11 Ply Mineral Surfaced Cap Sheet Adhered In Hot ASTM D 312 Type III or IV Asphalt ASTM D 6163 SIBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 Ibf/in 12.06.01 ROOFING MEMBRANE OPTION: tensile SF 4.49 ASTM D 6163 SIBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 Ibf/in 12.06.02 ROOFING MEMBRANE OPTION: tensile SF 6.01 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 Ibf/in 12.06.03 ROOFING MEMBRANE OPTION: tensile SF 5.41 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 Ibf/in 12.06.04 ROOFING MEMBRANE OPTION: tensile SF 7.01 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 Ibf/in 12.06.05 ROOFING MEMBRANE OPTION: tensile SF 7.76 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.06 Must includes coverage for roof uplift 12.06.06 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar 12.06.07 WARRANTY UPCHARGE: Limitations SF NSP-3 Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 12.06.08 WARRANTY UPCHARGE: Limitations SF NSP-1 Add to provide coverage for roof uplift 12.06.09 WARRANTY UPCHARGE: pressures up to 120 MPH SF NSP-2 ROOF CONFIGURATION # 1 Ply Cap Sheet, Set in Hot ASTM D 312 Type III or IV Asphalt, Flood Coat & Aggregate in Hot Modified Coal Tar 12.07 Pitch ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 Ibf/in tensile, Flood Coat in Modified Hot Coal 12.07.01 ROOFING MEMBRANE & COATING OPTION: Tar Pitch With 2000% Elongation SF 7.44 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 Ibf/in tensile, Flood Coat in Modified Hot Coal 12.07.02 ROOFING MEMBRANE & COATING OPTION Tar Pitch With 2000% Elongation SF 8.74 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 Ibf/in tensile, Flood Coat in Modified Hot Coal 12.07.03 ROOFING MEMBRANE & COATING OPTION Tar Pitch With 2000% Elongation SF 8.67 86 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 Ibf/in tensile, Flood Coat in Modified Hot Coal 12.07.04 ROOFING MEMBRANE & COATING OPTION Tar Pitch With 2000% Elongation SF 9.77 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum 600 Ibf/in tensile, Flood Coat in Modified Hot Coal 12.07.05 ROOFING MEMBRANE & COATING OPTION Tar Pitch With 2000% Elongation SF 10.21 Add/Deduct for Installing Flood Coat in 12.07.06 COATING OPTION: Cold Process Coal Tar Pitch SF -0.68 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.07 Must includes coverage for roof uplift 12.07.07 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar 12.07.08 WARRANTY UPCHARGE: Limitations SF NSP Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 12.07.09 WARRANTY UPCHARGE: Limitations SF NSP-1 Add to provide coverage for roof uplift 12,07.10 WARRANTY UPCHARGE: I pressures up to 120 MPH SF NSP-2 ROOF CONFIGURATION 12.08 1 Ply Cap Sheet, Flood Coat and Aggregate Adhered In Cold Process Modified Asphalt ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 Ibf/in 12.08.01 ROOFING MEMBRANE OPTION: tensile SF 6.79 ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 Ibf/in 12.08.02 ROOFING MEMBRANE OPTION: tensile SF 8.11 ASTM D 6162 SIBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 Ibf/in 12.08.03 ROOFING MEMBRANE OPTION: tensile SF 8.02 ASTM D 6162 SIBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 Ibf/in 12.08.04 ROOFING MEMBRANE OPTION: tensile SF 9.13 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 Ibf/in 12.08.05 ROOFING MEMBRANE OPTION: tensile SF 9.59 Add/Deduct for Cold Applied Modified BUR Substitute Cold Process Adhesive with 12.08.06 MEMBRANE ADHESIVE & COATING OPTION: Alternative Solvent Free Adhesive SF 5.43 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.08 Must includes coverage for roof uplift 12.08.07 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar 12.08.08 1 WARRANTY UPCHARGE: Limitations I SF I NSP 87 Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 12.08.09 WARRANTY UPCHARGE: Limitations Ipressures SF NSP-1 Add to provide coverage for roof uplift 12.08.10 WARRANTY UPCHARGE: up to 120 MPH SF NSP-2 ROOF CONFIGURATION 12.09 11 Ply Mineral Surfaced Cap Sheet Adhered in Cold Process Modified Asphalt ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 Ibf/in 12.09.01 ROOFING MEMBRANE OPTION: tensile SF 5.29 ASTM D 6163 SIBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 Ibf/in 12.09.02 ROOFING MEMBRANE OPTION: tensile SF 6.72 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 Ibflin 12.09.03 ROOFING MEMBRANE OPTION: tensile SF 6.07 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 Ibf/in 12.09.04 ROOFING MEMBRANE OPTION: tensile SF 8.28 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 Ibflin 12.09.05 ROOFING MEMBRANE OPTION: tensile SF 9.15 Add/Deduct for Cold Applied Modified BUR Substitute Cold Process Adhesive with 12.09.06 MEMBRANE ADHESIVE OPTION: Alternative Solvent Free Adhesive SF 1.82 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.09 Must includes coverage for roof uplift 12.09.07 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar 12.09.08 WARRANTY UPCHARGE: Limitations SF NSP-3 Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 12.09.09 WARRANTY UPCHARGE: Limitations SF NSP-1 Add to provide coverage for roof uplift 12.09.10 WARRANTY UPCHARGEJ pressures up to 120 MPH SF NSP-2 --'�ts: ROOF CONFIGURATION & Aggregate in Cold Applied Modified Coal Tar Pitch 1 Ply Cap Sheet, Set In Cold Process Asphalt, Flood Coat Sir 12.10 and Aggregate ' ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 Ibf/in 12.10.01 ROOFING MEMBRANE & COATING OPTION: tensile SF 7.76 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 Ibf/in 12.10.02 ROOFING MEMBRANE & COATING OPTION tensile SF 9.07 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 Ibf/in 12.10.03 ROOFING MEMBRANE & COATING OPTION tensile SF 9.00 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 Ibf/in 12.10.04 ROOFING MEMBRANE & COATING OPTION tensile I SF 10.10 88 ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum 600 Ibf/in 12.10.05 ROOFING MEMBRANE & COATING OPTION tensile SF 10.56 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.10 Must includes coverage for roof uplift 12,10.06 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar 12.10.07 WARRANTY UPCHARGE: Limitations SF NSP Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 12.10.08 WARRANTY UPCHARGE: Limitations SF NSP-1 Add to provide coverage for roof uplift 12.10.09 WARRANTY UPCHARGE:j pressures up to 120 MPH SF NSP-2 ROOF CONFIGURATION 12.11 1 Ply of Mineral Surfaced, Torch -Applied Cap Sheet Installed with Torch Application ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum 300 Ibf/in 12.11.01 ROOFING MEMBRANE OPTION: tensile Torch -Applied Membrane SF 7.49 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.11 Must includes coverage for roof uplift 12.11.02 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar 12.11.03 WARRANTY UPCHARGE: Limitations SF NSP-3 Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 12.11.04 WARRANTY UPCHARGE: Limitations SF NSP-1 Add to provide coverage for roof uplift 12.11.05 WARRANTY UPCHARGE: pressures up to 120 MPH SF NSP-2 ROOF CONFIGURATION 1 Ply of Torch -Applied Cap Sheet Installed with Torch Application and Finished with a Flood Coat & Aggregate in r 12.12 Cold Process Modified Asphalt ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 300 Ibf/in 12.12.01 ROOFING MEMBRANE OPTION: tensile Torch -Applied Membrane SF 8.90 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.12 Must includes coverage for roof uplift 12.12.02 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Labor & Material Warranty with No Dollar 12.12.03 WARRANTY UPCHARGE: Limitations SF NSP Labor & Material Warranty with No Dollar 12,12.04 WARRANTY UPCHARGE: Limitations SF NSP-1 Add o provide coverage for roof Uplift 12.12.05 WARRANTY UPCHARGE: pressures up to 120 MPH SF NSP-2 ROOF CONFIGURATION,,,_ 12.13 11'Ply .4 of Mineral Surfaced, Self -Adhering Cap Sheet Installed Using Self•Adhering Backing 89 ASTM D 6161 (Polyester) OR 6162 (Fiberglass/Polyester) OR 6163 (Fiberglass) Self -Adhering Reinforced Modified Bituminous Sheet Material Type 12.13.01 ROOF CONFIGURATION OPTION: III - Minimum of 130 Ibf/in tensile SF 5.26 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.13 Must includes coverage for roof uplift 12.13.02 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar 12.13.03 WARRANTY UPCHARGE: Limitations SF NSP-3 Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 12.13.04 WARRANTY UPCHARGE: Limitations SF NSP-1 Add to provide coverage for roof uplift 12.13.05 WARRANTY UPCHARGE: pressures up to 120 MPH SF NSP-2 ROOF CONFIGURATION 1 Ply Fleece -Back Polymeric Cap Sheet (Top Ply) Adhered In Hot ASTM D 312 Type III OR IV Asphalt with Heat 12.14 Welded Seams ASTM D 6754 - Ketone Ethylene Ester 12,14.01 POLYMERIC TOP PLY OPTION: (KEE) - 50 Mil Thickness SF 5.87 ASTM D 6754 - Ketone Ethylene Ester 12.14.02 POLYMERIC TOP PLY OPTION: (KEE) - 60 Mil Thickness SF 9.50 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.14 Must includes coverage for roof uplift 12.14.03 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar 12.14.04 WARRANTY UPCHARGE: Limitations SF NSP Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 12.14.05 WARRANTY UPCHARGE:1 Limitations SF NSP-1 Add to provide coverage for roof uplift 12.14.06 WARRANTY UPCHARGE: pressures up to 120 MPH SF NSP-2 ROOF CONFIGURATION 12.15 1 Ply Fleece -Back Polymeric Cap Sheet (Top Ply) Adhered in Membrane Adhesive with Heat Weld Seams ASTM D 6754 - Ketone Ethylene Ester 12.15.01 POLYMERIC TOP PLY OPTION: (KEE) - 50 Mil Thickness SF 8.05 ASTM D 6754 - Ketone Ethylene Ester 12.15.02 POLYMERIC TOP PLY OPTION: (KEE) - 60 Mil Thickness SF 12.22 Add/Deduct for Cold Applied Fleece - Back Polymeric Cap Sheet (Top Ply) Substitute Membrane Adhesive with 12.15.03 MEMBRANE ADHESIVE OPTION: Cold Applied Asphalt Adhesive SF -0.20 PER SQUARE FOOT COST - Cold Applied Fleece -Back Polymeric Cap Sheet (Top Ply) Substitute Membrane Adhesive with 12.15.04 MEMBRANE ADHESIVE OPTION: Solvent -Free Asphalt Adhesive SF 1.72 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.15 Must includes coverage for roof uplift 12.15.05 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Labor & Material Warranty with No Dollar 12,15.06 WARRANTY UPCHARGE: Limitations SF NSP 112.15.08 Labor & Material Warranty with No Dollar WARRANTY UPCHARGE: Limitations SF NSP-1 90 jAdd o provide coverage for roof uplift 12.15.09 WARRANTY UPCHARGE: I pressures up to 120 MPH SF NSP-2 BUILT-UP COAL TAR ROOF WITH FLOOD COAT AND AGGREGATE IN t 13.00 MODIFIED HOT COAL TAR PITCH ROOF CONFIGURATION 1 Ply of Glass Base, 3 Plies of Polyester Mat or 4 ply of Coal Tar Felts In Modified Hot Coal Tar Pitch (CTP), 13.01 [Insulation & Glass Base] Set in Hot ASTM D 312 Type III or IV Asphalt 4-Ply ASTM D 4990 Type I Coal Tar Saturated Felts in Modified Coal Tar Pitch; Modified CTP with 2000% 13.01.01 ROOF CONFIGURATION OPTION: Elongation SF 13.99 3-Ply Continuous Filament Polyester Mat (5.0 oz./yd2) in Modified Coal Tar Pitch; 13.01.02 ROOF CONFIGURATION OPTION: Modified CTP with 2000% Elongation SF 1 13.22 PER SQUARE FOOT COST - SUBSTITUTE STANDARD COAL TAR PITCH Add/Deduct for Using Standard Coal Tar 13.02 INTERPLY ADHESIVE & FLOOD COAT OPTION: Pitch Instead of Modified Coal Tar Pitch SF -3.49 PER SQUARE FOOT COST - SUBSTITUTE COLD PROCESS+ MODIFIED COAL TAR PITCH FOR FLOOD COAT Add/Deduct for Using Cold Process Modified Coal Tar Pitch for Flood Coat Instead of Hot Modified Coal Tar 13.03 FLOOD COAT OPTION: Pitch+B222 SF -0.56 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 13.00 Must includes coverage for roof uplift 13.04 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar 13.05 WARRANTY UPCHARGE: Limitations SF NSP Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 13.06 WARRANTY UPCHARGE: Limitations SF NSP-1 Add to provide coverage for roof uplift 13.07 WARRANTY UPCHARGEJ pressures up to 120 MPH SF NSP-2 14A0 s METAL -ROOFING SYSTEMS - L01N SLOPE & STEEP; SLOPE,(2) ," 1 14.01 INSULATION OPTIONS FOR ARCHITECTURAL STANDING SEAM ROOF INSTALLATION OVER SUBSTRATE Architectural Application - No Insulation; 30 lbs. Felt Underlayment 14.01.01 INSULATION OPTION: Over Deck SF 0.94 Architectural Application - No Insulation - WOOD DECK: Class A 14.01.02 INSULATION OPTION: Fire -Retardant Underlayment SF 4.58 Architectural Application - Minimal Insulation - WOOD OR METAL DECK: Must Have 112" Treated Gypsum Board with Glass -Mat (e.g. DensDeck / Securock / Equal); & 40 mil Self- 14.01.03 INSULATION OPTION: Adhering Underlayment SF 5.08 Architectural Application - Mechanically Fasten Polyisocyanurate to Provide an Average R-Value of 20; with 14.01.04 INSULATION OPTION: 40 mil Self -Adhering Underlayment I SF 1 6.61 91 Structural Application Over Open Framing; Over Retrofit Framing; Over an Existing Roof Using Steel Furring - 14.01.05 INSULATION OPTION: No Insulation SF 2.44 Structural Application Over Open Framing or Over Retrofit Framing - Fiberglass Batten Insulation with an R- 14.01.06 INSULATION OPTION: Value of 30 SF 3.11 Structural Application Over Retrofit Framing - Loose Laid Fiberglass Blanket on 14.01.07 INSULATION OPTION: Existing Deck with an R-Value of 30 SF 3.08 Structural Application Over an Existing Roof Using Steel Furring - Fiberglass Batten Insulation with an R- 14.01.08 INSULATION OPTION: Value of 20 SF 4.30 Structural Application Over an Existing Roof Using Steel Furring - Mechanically Fastened Polyisocyanurate 14.01.09 INSULATION OPTION: on Existing Roof with an R-Value of 20 SF 6.37 14.02 Architectural or Structural Standing Seam Roof System; Seam Height At or Above 2" Bare Aluminum Panel Price - 14.02.01 THICKNESS OPTION: 0.032" Aluminum, 18" - 19" Wide Panels SF 7.00 Add for Bare Aluminum 0,040" 14.02.02 THICKNESS OPTION: Aluminum, 18" - 19" Wide Panels SF 1.28 Add for 12" - 13" Panel Width - 14.02.03 PANEL WIDTH OPTION: Aluminum SF 1.82 Add for 16" - 17" Panel Width - 14.02.04 PANEL WIDTH OPTION: Aluminum SF 0.67 Add for 24" - 25" Panel Width - 14.02.05 PANEL WIDTH OPTION: Aluminum SF 1.09 Bare Galvalume Coated Steel or Equal Panel Price - 24 Ga, 18" - 19" Wide 14.02.06 THICKNESS OPTION: Panels SF 6.28 Bare Galvalume Coated Steel or Equal Panel Price - 22 Ga, 18" - 19" Wide 14.02.07 THICKNESS OPTION: Panels SF 7.61 Add for 12" - 13" Panel Width - 14.02.08 PANEL WIDTH OPTION: Galvalume Coated Steel or Equal SF 1.76 Add for 16" - 17" Panel Width - 14.02.09 PANEL WIDTH OPTION: Galvalume Coated Steel or Equal SF 0.67 Add for 24" - 25" Panel Width - 14.02.10 PANEL WIDTH OPTION: Galvalume Coated Steel or Equal SF 1.09 Add for Standard Colors - Fluorocarbon Paint System Over Aluminum or 14.02.11 COLOR OPTION: Galvalume Coated Steel Or Equal SF 1.21 Add for Designer Colors - Fluorocarbon Paint System Over Aluminum or 14.02.12 COLOR OPTION: Galvalume Coated Steel Or Equal SF 1.45 Add for Premium or Custom Colors - Fluorocarbon Paint System Over Aluminum or Galvalume Coated Steel Or 14.02.13 COLOR OPTION: Equal SF 1.76 Stainless Steel Panel Price - 24 Ga , 18" - 19" Wide 14.02.14 THICKNESS OPTION: Panels SF 21.93 Stainless Steel Panel Price - 22 Ga, 18" - 19" Wide 14.02.15 THICKNESS OPTION: Panels SF 26.02 92 Add for 12" -13" Panel Width - Stainless 14.02.16 PANEL WIDTH OPTION: Steel SF 5.47 Add for 16" - 17" Panel Width - Stainless 14.02.17 PANEL WIDTH OPTION: Steel SF 1.81 Add for 24" - 25" Panel Width - Stainless 14.02.18 PANEL WIDTH OPTION: Steel SF 0.37 Copper Panel Price - 16 oz,18" - 19" Wide 14.02.19 THICKNESS OPTION: Panels SF 23.74 Copper Panel Price - 20 Oz, 18" - 19" Wide 14.02.20 THICKNESS OPTION: Panels SF 28.76 14.02.21 PANEL WIDTH OPTION: Add for 12" - 13" Panel Width - Copper SF 5.76 14.02.22 PANEL WIDTH OPTION: Add for 16" - 17" Panel Width - Copper SF 2.02 14.02.23 PANEL WIDTH OPTION: Add for 24" - 25" Panel Width - Copper SF 0.44 Zinc Panel Price - 0.032", 18" - 19" Wide 14.02.24 THICKNESS OPTION: Panels SF 21.87 Zinc Panel Price - 0.040", 18" - 19" Wide 14.02.25 THICKNESS OPTION: Panels SF 26.00 14.02.26 PANEL WIDTH OPTION: Add for 12" -13" Panel Width - Zinc SF 5.58 14.02.27 PANEL WIDTH OPTION: Add for 16" - 17" Panel Width - Zinc SF 1.81 14.02.28 PANEL WIDTH OPTION: Add for 24" - 25" Panel Width - Zinc SF 0.37 Architectural Application - Installed Over 14,02.29 PANEL INSTALLATION OPTION: a Deck At or Above 3:12 Slope SF 8.07 Architectural Application - Installed Over a Deck Below 3:12 Slope 14.02.30 PANEL INSTALLATION OPTION: SF 6.80 Structural Application - Installed Over Open Framing At or Above 3:12 Slope 14.02.31 PANEL INSTALLATION OPTION: SF 8.07 Structural Application - Installed Over Open Framing Below 3:12 Slope 14.02.32 PANEL INSTALLATION OPTION: SF 6.80 Structural Application - At or Above 3:12 Slope - 14.02.33 PANEL INSTALLATION OPTION: Installed Over Retrofit Framing System SF 17.84 Structural Application - Installed Over Retrofit Framing System Below 3:12 Slope 14.02.34 PANEL INSTALLATION OPTION: SF 16.18 Structural Application - Installed Over Existing Roof Using Steel Furring At or Above 3:12 Slope 14.02.35 PANEL INSTALLATION OPTION: SF 9.86 Structural Application - Installed Over Existing Roof Using Steel Furring Below 14.02.36 PANEL INSTALLATION OPTION: 3:12 Slope SF 7.88 On -Site Roll Forming - To achieve panel lengths in excess of shipping or 14.02,37 PANEL FABRICATION OPTION: transportation limitations SF Curving Panels - Curving panels to meet 14.02.38 PANEL FABRICATION OPTION: architectural requirements SF 2.55 Tapering Panels - Tapering panels to 14.02.39 PANEL FABRICATION OPTION: meet architectural requirements SF 2.55 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 13.00 Must includes coverage for roof uplift 14.02.40 WARRANTY CHARGE: pressures up to 90 MPH SF NSP 93 Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar 14.02.41 WARRANTY UPCHARGE: Limitations SF NSP Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 14.02.42 WARRANTY UPCHARGE: Limitations SF NSP Add to provide coverage for roof uplift 14.02.43 WARRANTY UPCHARGE:j pressures up to 120 MPH SF NSP ROOF CONFIGURATION 14.03 Architectural or Structural Standing Seam Roof System; Seam Height At or Above 1" Below 2'; Aluminum Panels Bare Aluminum Panel Price - 14.03.01 THICKNESS OPTION: 0.032" Aluminum, 18" Wide Panels SF 5.38 Add for Bare Aluminum 0.040" 14.03.02 THICKNESS OPTION: Aluminum, 18" Wide Panels SF 1.21 14.03.03 PANEL WIDTH OPTION: Add for 12" Panel Width - Aluminum SF 2.06 14.03.04 PANEL WIDTH OPTION: Add for 16" Panel Width - Aluminum SF 0.43 Bare Galvalume Coated Steel or Equal 14.03.05 THICKNESS OPTION: Panel Price -24 Ga, 18" Wide Panels SF 5.01 Bare Galvalume Coated Steel or Equal 14.03.06 THICKNESS OPTION: Panel Price - 22 Ga, 18" Wide Panels SF 6.04 Add for 12" Panel Width - Galvalume 14.03.07 PANEL WIDTH OPTION: Coated Steel or Equal SF 1.28 Add for 16" Panel Width - Galvalume 14.03.08 PANEL WIDTH OPTION: Coated Steel or Equal SF 0.37 Add for Standard Colors - Fluorocarbon Paint System Over Aluminum or 14.03.09 COLOR OPTION: Galvalume Coated Steel Or Equal SF 1.15 Add for Designer Colors - Fluorocarbon Paint System Over Aluminum or 14.03.10 COLOR OPTION: Galvalume Coated Steel Or Equal SF 1.39 Add for Premium or Custom Colors - Fluorocarbon Paint System Over Aluminum or Galvalume Coated Steel Or 14.03.11 COLOR OPTION: Equal SF 1.69 Stainless Steel 14.03.12 THICKNESS OPTION: Panel Price - 24 Ga, 18" Wide Panels SF 21.21 Stainless Steel 14.03.13 THICKNESS OPTION: Panel Price -22 Ga, 18" Wide Panels SF 25.31 14.03.14 PANEL WIDTH OPTION: Add for 12" Panel Width - Stainless Steel SF 5.47 14.03.15 PANEL WIDTH OPTION: Add for 16" Panel Width - Stainless Steel SF 1.81 Copper 14.03.16 THICKNESS OPTION: Panel Price - 16 oz,18" Wide Panels SF 23.15 Copper 14,03.17 THICKNESS OPTION: Panel Price - 20 Oz, 18" Wide Panels SF 28.41 14.03.18 PANEL WIDTH OPTION: Add for 12" Panel Width - Copper SF 5.76 14.03.19 PANEL WIDTH OPTION: Add for 16" Panel Width - Copper SF 2.02 Zinc 14.03.20 THICKNESS OPTION: Panel Price - 0.032", 18" Wide Panels SF 21.49 Zinc 14.03.21 THICKNESS OPTION: Panel Price - 0.040", 18" Wide Panels SF 25.67 14.03.22 PANEL WIDTH OPTION: Add for 12" Panel Width - Zinc SF 5.47 14.03.23 PANEL WIDTH OPTION: Add for 16" Panel Width - Zinc SF 1.81 Architectural Application - Installed Over Substrate At or Above 3:12 Slope 14.03.24 PANEL INSTALLATION OPTION: SF 7.94 Architectural Application - Installed Over Substrate Below 3:12 Slope 14.03.25 PANEL INSTALLATION OPTION: SF 6.67 94 Structural Application - Installed Over Open Framing At or Above 3/12 Slope 14.03.26 PANEL INSTALLATION OPTION: SF 7.94 Structural Application - Installed Over Retrofit Framing System At or Above 3:12 Slope 14.03.27 PANEL INSTALLATION OPTION: SF 17.69 Structural Application - Installed Over Existing Roof Using Steel Furring 14.03.28 PANEL INSTALLATION OPTION: At or Above 3:12 Slope SF 9.72 Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 14.03 Must includes coverage for roof uplift 14.03.30 WARRANTY CHARGE: pressures up to 90 MPH SF NSP Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar 14.03.31 WARRANTY UPCHARGE: Limitations SF NSP Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar 14.03.32 WARRANTY UPCHARGE: Limitations SF NSP Add to provide coverage for roof uplift 14.03.33 WARRANTY UPCHARGE:j pressures up to 120 MPH SF NSP 14.04 Architectural Standing Seam Roof System; Seam Height Below 1" Bare Aluminum Panel Price - 14.04.01 THICKNESS OPTION: 0.032" Aluminum, 14.5" Wide Panels SF 4.89 Add for Bare Aluminum 0.040" 14.04.02 THICKNESS OPTION: Aluminum, 14.5" Wide Panels SF 5.82 Bare Galvalume Coated Steel or Equal 14.04.03 THICKNESS OPTION: Panel Price - 24 Ga, 14.5" Wide Panels SF 4.75 Bare Galvalume Coated Steel or Equal 14.04.04 THICKNESS OPTION: Panel Price -22 Ga, 14.5" Wide Panels SF 5.34 Add for Standard Colors - Fluorocarbon Paint System Over Aluminum or 14.04.05 COLOR OPTION: Galvalume Coated Steel Or Equal SF 1.00 Add for Designer Colors - Fluorocarbon Paint System Over Aluminum or 14.04.06 COLOR OPTION: Galvalume Coated Steel Or Equal SF 1.28 Add for Premium or Custom Colors - Fluorocarbon Paint System Over Aluminum or Galvalume Coated Steel Or 14.04.07 COLOR OPTION: Equal SF 1.38 Stainless Steel 14.04.08 THICKNESS OPTION: Panel Price - 24 Ga, 14.5" Wide Panels SF 21.59 Stainless Steel 14.04.09 THICKNESS OPTION: Panel Price - 22 Ga, 14.5" Wide Panels SF 25.48 Copper 14.04.10 THICKNESS OPTION: Panel Price - 16 Oz., 14.5" Wide Panels SF 23.29 Copper 14.04.11 THICKNESS OPTION: Panel Price - 20 Oz., 14.5" Wide Panels SF 28.49 Zinc 14.04.12 THICKNESS OPTION: Panel Price - 0.032" , 14.5" Wide Panels SF 22.16 95 Zinc 14.04.13 THICKNESS OPTION: Panel Price - 0.040", 14.5" Wide Panels SF 26.29 Architectural Application - Installed Over 14.04.14 PANEL INSTALLATION OPTION: Substrate At or Above 3:12 Slope SF 8.38 Architectural Application - Installed Over 14,04.15 PANEL INSTALLATION OPTION: Substrate Below 3:12 Slope SF 7.00 Cost to Provide 15 Year - Material Warranty Limited to the Dollar Amount of the Material Original Purchase as a Standard Warranty for All Applications in this Section 14.04 Must includes coverage for roof uplift 14.04.16 WARRANTY CHARGE: pressures up to 90 MPH SF NSP 14.05 Flat Seam Metal Roof System - 8' Wlde 130 Gauge 3/4" of Expanded Polystyrene (Minimum 1.5 lbs./cft) - Includes Panel and 14.05.01 INSULATION OPTION: Installation of Roof System SF 16.62 Mechanically Fastened Polyisocyanu rate with an Average R-Value of 20 - Includes 14.05.02 INSULATION OPTION: Panel and Installation of Roof System SF 19.34 Add Install 40 mil self-adhesive 14.05.03 UNDERLAYMENT OPTION: membrane as an Underlayment SF 2.37 14.05.04 PANEL WIDTH OPTION: Add/Deduct for 6' Wide Option SF 0.82 14.05.05 PANEL WIDTH OPTION: Add/Deduct for 10' Wide Option SF 0.00 14.05.06 PANEL WIDTH OPTION: Add/Deduct for 12' Wide Option SF -0.86 Cost to Provide 15 Year - Material Warranty Limited to the Dollar Amount of the Material Original Purchase as a Standard Warranty for All Applications in this Section 14.05 Must includes coverage for roof uplift 14.05.07 WARRANTY CHARGES:j pressures up to 90 MPH SF NSP 15 00 , ,.' RESTORATIONS , REGOATING OF EXISTING ROOF-.- PREPARE METAL ROOF FOR RESTORATION BY WIRE BRUSHING ROOF SURFACE 15.01 Wire Brush Metal Roof Surface to Remove Loose Paint, Rust or Expose Bare Metal SF 2.46 PREPARE METAL ROOF FOR RESTORATION BY WIRE BRUSHING METAL ROOF SEAMS 15.02 Wire Brush Metal Roof Seams to Remove Loose Paint, Rust or Expose Bare Metal LF 3.50 PREPARE METAL ROOF FOR RESTORATION BY SANDBLASTING METAL ROOF 15.03 Sand -Blast Metal Roof Surface and Seams to Remove Loose Paint, Rust or Expose Bare Metal SF 4.56 RESATURATION OF ASPHALT ROOF SURFACE WITH ASPHALT COATING SYSTEM Wet Vac Roof to Remove Aggregate, Apply Cold Applied Modified Asphalt Flood Coat & New Aggregate - Coating Applied at 6-8 Gallons per Sq. w/ New Gravel According to Manufacturer's Specifications (New Flashings also Required 15.04 Separate Line Item) SF 5.24 RESATURATION OF ASPHALT OR COAL TAR PITCH BURs WITH COAL -TAR PITCH COATING SYSTEM Wet Vac Roof to Remove Aggregate, Apply Cold Applied Modified Coal Tar Flood Coat & New Aggregate as Specified Applied at 6-8 Gallons per Sq. w/ New Gravel According to Manufacturer's Specifications (New Flashings also Required 15.05 Refer to Flashing Line Item) SF 8.39 RESTORATION OF METAL ROOF SYSTEM WITH SYNTHETIC RUBBER COLD -APPLIED COATING Prepare Metal Roof Surface by Scraping, Sanding, Wire Brush or Blasting (USE SEPRATE LINE ITEM FOR BLASTING OR WIRE BRUSHING); Clean with TSP or Simple Green; Use Portable Blowers to Clear Roof of Moisture; Apply seam sealer to seams (1 Gallon per 14 left) Base Coat / Top Coat with Synthetic Rubberized Restorative Coating (1.5 Gallons 15.06 per Sq.) According to Manufacturer's Specifications SF 4.76 RESTORATION OF A METAL ROOF SYSTEM WITH SINGLE -COMPONENT URETHANE Prepare Metal Roof Surface by Scraping, Sanding, Wire Brush or Blasting (USE SEPARATE LINE ITEM FOR BLASTING OR WIRE BRUSHING); Clean with TSP or Simple Green, Apply Primer with Rust Inhibiting and Chemical Corrosion Resistance at a Rate of 1/4 Gallon per Square; Wait at least 3 Hours for Primer to Dry; Strip in Seams, Around Penetrations and Fasteners with a Single -Component, Aliphatic Urethane at a Rate of 2 Gallons per Square i Reinforcement / 1 Gallon per Square (3 Gallons per Square on All Stripped in Areas) USE SEPARATE LINE ITEM; Wait 24-48 Hours; Apply Single -Component, Aliphatic Urethane as a Base Coat at a Rate of 1.5 Gallons per Square and Top 15.07 Coat at a Rate of 1.0 Gallon per Square Over the Entire Roof According to Manufacturer's Specifications. SF 7.00 L RESTORATION OF A METAL ROOF SYSTEM WITH TWO -COMPONENT, LOW-ODER URETHANE Prepare Metal Roof Surface by Scraping, Sanding, Wire Brush or Blasting (USE SEPARATE LINE ITEM FOR BLASTING OR WIRE BRUSHING); Clean with TSP or Simple Green, Apply Primer with Rust Inhibiting and Chemical Corrosion Resistance at a Rate of 1/4 Gallon per Square; Wait at least 3 Hours for Primer to Dry; Strip in Seams, Around Penetrations and Fasteners with a Two -Component, Low -Oder Urethane at a Rate of 2 Gallons per Square / Reinforcement / 1 Gallon per Square (3 Gallons per Square on All Stripped -In Areas) USE SEPARATE LINE ITEM; Wait 24-48 Hours; Apply Two -Component, Low -Oder Urethane as a Base Coat at a Rate of 1.5 Gallons per Square and Top 15.08 Coat at a Rate of 1.0 Gallon per Square Over the Entire Roof According to Manufacturer's Specifications. SF 7.13 COAT ROOF WITH HIGH PERFORMANCE FLUORPOLYMER PAINT SYSTEM FOR METAL ROOFS Prepare Metal Roof Surface by Scraping, Sanding, Wire Brushing or Blasting (USE SEPARATE LINE ITEM FOR BLASTING & WIRE BRUSHING); Clean with TSP or Simple Green, Prime at a Rate of (Primer 1/4" Gallon per Square); 15.09 Wait; Install Base Coat and Top Coat at a Rate of 1/4 Gallon per Sq. per Coat According to Manufacturer's Specifications SF 5.21 RESTORATION OF A SINGLE -PLY WITH SINGLE -COMPONENT URETHANE & STRIPPED SEAMS Prepare Roof Surface by Cleaning with TSP or Simple Green, Use Portable Blowers to Clear the Roof Surface of Moisture; Strip in Seams by Applying a Single -Component, Aliphatic Urethane 2 Gallons per Square USE SEPARATE LINE ITEM, Wait 24-48 Hours, Apply Single -Component, Aliphatic Urethane as a Base Coat at a Rate of 1.5 Gallons per Square and Top Coat at a Rate of 1.0 Gallon per Square Over the Entire Roof According to Manufacturer's 15.10 Specifications. SF 6.30 RESTORATION OF SMOOTH -SURFACED BURs/MODIFIED BURS ROOF SYSTEMS WITH SINGLE -COMPONENT URETHANE & REINFORCED SEAMS Prepare Roof Surface by Cleaning with TSP or Simple Green, Use Portable Blowers to Clear the Roof Surface of Moisture; Reinforce Seams by Applying a Single -Component, Aliphatic Urethane 2 Gallons per Square / Reinforcement / 1 Gallon per Square (3 Gallons per Square on Seams) USE SEPARATE LINE ITEM, Wait 24-48 Hours, Apply Single - Component, Aliphatic Urethane as a Base Coat at a Rate of 2 Gallons per Square and a Top Coat of 1.5 Gallons per 15.11 Square Over the Entire Roof According to Manufacturer's Specifications. SF 8.21 RESTORATION OF A SINGLE -PLY ROOF OR SMOOTH -SURFACE BUR/MODIFIED BUR SYSTEMS WITH FULLY - REINFORCED, SINGLE -COMPONENT URETHANE Prepare Roof Surface by Cleaning with TSP or Simple Green, Use Portable Blowers to Clear the Roof Surface of Moisture; Reinforce Entire Roof Surface by Applying a Single -Component, Aliphatic Urethane 2 Gallons per Square / Reinforcement / 1 Gallon per Square (3.0 Gallons per Square Total Prior to Top Coat), Wait 24-48 Hours, Apply Single - Component, Aliphatic Urethane as a Top Coat at a Rate of 2 Gallons per Square Over the Entire Roof According to 15.12 Manufacturer's Specifications. SF 12.29 RESTORATION OF A MINERAL -SURFACED BURs/MODIFIED BURS ROOF SYSTEMS WITH SINGLE -COMPONENT URETHANE & REINFORCED SEAMS Prepare Roof Surface by Cleaning with TSP or Simple Green, Use Portable Blowers to Clear the Roof Surface of Moisture; Reinforce Seams by Applying a Single -Component, Aliphatic Urethane 2 Gallons per Square / Reinforcement / 1 Gallon per Square (3 Gallons per Square on Seams) USE SEPARATE LINE ITEM, Wait 24-48 Hours, Apply Single - Component, Aliphatic Urethane as a Base Coat at a Rate of 2.0 Gallons per Square and Top Coat at a Rate of 2.0 15.13 Gallons per Square Over the Entire Roof According to Manufacturer's Specifications. SF 9.26 RESTORATION OF A MINERAL -SURFACE BURIMODIFIED BUR SYSTEMS WITH FULLY -REINFORCED, SINGLE - COMPONENT URETHANE Prepare Roof Surface by Cleaning with TSP or Simple Green, Use Portable Blowers to Clear the Roof Surface of Moisture; Reinforce Entire Roof Surface by Applying a Single -Component, Aliphatic Urethane 2 Gallons per Square / Reinforcement 11.5 Gallon per Square (3.5 Gallons per Square Total Prior to Top Coat), Wait 24-48 Hours, Apply Single - Component, Aliphatic Urethane as a Top Coat at a Rate of 2 Gallons per Square Over the Entire Roof According to 15.14 Manufacturer's Specifications. SF 13.34 RESTORATION OF A SINGLE -PLY WITH TWO -COMPONENT, LOW-ODER URETHANE & STRIPPED SEAMS Prepare Roof Surface by Cleaning with TSP or Simple Green, Use Portable Blowers to Clear the Roof Surface of Moisture; Strip in Seams by Applying a Two -Component, Low -Oder Urethane 2 Gallons per Square USE SEPARATE LINE ITEM, Wait 24-48 Hours, Apply Two -Component, Low -Oder Urethane as a Base Coat at a Rate of 1.5 Gallons per Square and a Top Coat at a Rate of 1.0 Gallon per Square Over the Entire Roof According to Manufacturer's 15.15 Specifications. I F 6.55 97 RESTORATION OF SMOOTH -SURFACED BURs/MODIFIED BURS ROOF SYSTEMS WITH TWO -COMPONENT, LOW-ODER URETHANE & REINFORCED SEAMS Prepare Roof Surface by Cleaning with TSP or Simple Green, Use Portable Blowers to Clear the Roof Surface of Moisture; Reinforce Seams by Applying a Two -Component, Low -Oder Urethane 2 Gallons per Square / Reinforcement / 1 Gallon per Square (3 Gallons per Square on Seams) USE SEPARATE LINE ITEM, Wait 24-48 Hours, Apply Two - Component, Low -Oder Urethane as a Base Coat at a Rate of 2 Gallons per Square and a Top Coat at a Rate of 1.5 15.16 Gallons per Square Over the Entire Roof According to Manufacturer's Specifications, SF 8,70 RESTORATION OF A SINGLE -PLY ROOF OR SMOOTH -SURFACE BUR/MODIFIED BUR SYSTEMS WITH FULLY - REINFORCED, TWO -COMPONENT, LOW-ODER URETHANE Prepare Roof Surface by Cleaning with TSP or Simple Green, Use Portable Blowers to Clear the Roof Surface of Moisture; Reinforce Entire Roof Surface by Applying a Two -Component, Low -Oder Urethane 2 Gallons per Square / Reinforcement / 1 Gallon per Square (3 Gallons per Square Total Prior to Top Coat), Wait 24-48 Hours, Apply Two - Component, Low -Oder Urethane as a Top Coat at a Rate of 2 Gallons per Square Over the Entire Roof According to 15.17 Manufacturer's Specifications. SF 12.80 RESTORATION OF A MINERAL -SURFACED BURs/MODIFIED BURS ROOF SYSTEMS WITH TWO -COMPONENT, LOW -ODOR URETHANE & REINFORCED SEAMS Prepare Roof Surface by Cleaning with TSP or Simple Green, Use Portable Blowers to Clear the Roof Surface of Moisture; Reinforce Seams by Applying a Two -Component, Low -Oder Urethane 2.0 Gallons per Square / Reinforcement / 1.0 Gallon per Square (3 Gallons per Square on Seams) USE SEPARATE LINE ITEM, Wait 24-48 Hours, Apply Two - Component, Low -Oder Urethane as a Base Coat at a Rate of 2.0 Gallons per Square and a Top Coat at a Rate of 2.0 15.18 Gallons per Square Over the Entire Roof According to Manufacturer's Specifications. SF 9.76 RESTORATION OF A MINERAL -SURFACE BUR/MODIFIED BUR SYSTEMS WITH FULLY -REINFORCED, TWO - COMPONENT, LOW-ODER URETHANE Prepare Roof Surface by Cleaning with TSP or Simple Green, Use Portable Blowers to Clear the Roof Surface of Moisture; Reinforce Entire Roof Surface by Applying a Two -Component, Low -Oder Urethane 2 Gallons per Square / Reinforcement / 1.5 Gallon per Square (3.5 Gallons per Square Total Prior to Top Coat), Wait 24-48 Hours, Apply Two - Component, Low -Oder Urethane as a Top Coat at a Rate of 2 Gallons per Square Over the Entire Roof According to 15.19 Manufacturer's Specifications. SF 13.86 RESATURATION OF SMOOTH -SURFACED ASPHALT ROOF WITH FULLY REINFORCED FIBERED ASPHALT COATING SYSTEM Infrared roof scan roof system and replace all wet insulation (USE SEPARATE LINE ITEMS); Prime the roof surface at rate of 1/2 - 3/4 Gallons per Square; Apply heavy -bodied, fiber reinforced asphalt roof coating and embed firm polyester 15.20 reinforcement at a rate of 3.0 Gallons per Square / Polyester /3.5 Gallons per Square. SF 3.62 RESATURATION OF SMOOTH -SURFACED ASPHALT ROOF WITH FULLY REINFORCED FIBERED ASPHALT COATING SYSTEM Infrared roof scan roof system and replace all wet insulation (USE SEPARATE LINE ITEMS); Prime the roof surface at rate of 1/2 - 3/4 Gallons per Square; Apply heavy -bodied, fiber reinforced asphalt roof coating and embed soft polyester 15.21 reinforcement at a rate of 1.2 Gallons per Square / Polyester /1.4 Gallons per Square. SF 4.18 RESATURATION OF MINERAL -SURFACED ASPHALT ROOF WITH FULLY REINFORCED FIBERED ASPHALT COATING SYSTEM Infrared roof scan roof system and replace all wet insulation (USE SEPARATE LINE ITEMS); Prime the roof surface at rate of 1/2 - 3/4 Gallons per Square; Apply heavy -bodied, fiber reinforced asphalt roof coating and embed firm polyester 15.22 reinforcement at a rate of 3.5 Gallons per Square / Polyester / 3.5 Gallons per Square. SF 3.80 RESATURATION OF MINERAL -SURFACED ASPHALT ROOF WITH FULLY REINFORCED FIBERED ASPHALT COATING SYSTEM Infrared Roof Scan Roof System And Replace All Wet Insulation (Use Separate Line Items); Prime The Roof Surface At Rate Of 1/2 - 3/4 Gallons Per Square; Apply Heavy -Bodied, Fiber Reinforced Asphalt Roof Coating And Embed Soft 15.23 Polyester Reinforcement At A Rate Of 1.4 Gallons Per Square / Polyester /1.4 Gallons Per Square. SF 4.42 COAT EXISTING ROOF SURFACE WITH FIBRATED ALUMINUM ROOF COATING Prepare Roof Surface by Sweeping Off All Dirt, Dust and Debris; If Existing Roof Surface is Weathered, Prime the Roof Surface at a Rate of 1 Gallon per Square; If Repairs to Any Cracks, Splits or Surface Irregularities Exist, Repair with a 3 Course Application of Mastic / Mesh / Mastic (USE SEPARATE LINE ITEM); Apply Fibrated Aluminum Roof Coating at a 15.24 Rate of 2 Gallons per Square. SF 2.14 RESTORATION OF SMOOTH -SURFACED OR MINERAL -SURFACED ASPHALT -BASED ROOF WITH FULLY - REINFORCED GLASS FIBERED ASPHALT EMULSION Prepare Roof Surface to be Clean & Free of Dust; Repair All Splits Tears of Blisters with a Three Course Application of Mastic / Mesh / Mastic (USE SEPARATE LINE ITEM); Prime the Roof Surface at a Rate of 1/2 Gallon per Square. Embed Polyester into the Asphalt Emulsion in a 2 Coat Application at a Rate of 3 Gallons per Square / Polyester / 3 15.25 Gallons per Square I SF 3.37 98 RESTORATION OF SMOOTH -SURFACED OR MINERAL -SURFACED ASPHALT -BASED ROOF WITH GLASS FIBERED ASPHALT EMULSION Prepare Roof Surface to be Clean & Free of Dust; Repair All Splits Tears of Blisters with a Three Course Application of Mastic / Mesh / Mastic (USE SEPARATE LINE ITEM); Prime the Roof Surface at a Rate of 1/2 Gallon per Square. Apply 15.26 Asphalt Emulsion in a 2 Coat Application at a Rate of 2.5 Gallons per Square per Coat. SF 2.35 RESTORATION OF SINGLE -PLY, SMOOTH -SURFACED OR MINERAL -SURFACED ASPHALT -BASED ROOF WITH SILICONE COATING Prepare Roof Surface to be Clean & Free of Dust; Apply Silicone Coating System in a Single Coat Application at a Rate 15.27 of 2.5 Gallons per Square SF 3.90 RESTORATION OF GRAVEL -SURFACED ASPHALT -BASED ROOF WITH SILICONE COATING Wet Vac or Spud Any Loose Gravel Off of Roof Surface & Dispose; Sweep Roof Surface to be Clean and Free of Dust; Apply Primer as a Bleed-Blocker at a Rate of 1/2 Gallon per Square; Apply Self -Leveling Silicone at a Rate of 6 Gallons 15.28 per Square; Apply Silicone Coating System in a Single Coat Application at a Rate of 2.5 Gallons per Square. SF 5.86 ELASTOMERIC ASPHALT -BASED LIQUID APPLIED MEMBRANE SYSTEM FOR SMOOTH OR MINERAL SURFACED ROOFS Clean and Prime then Install Base Coat / Top Coat as Specified with Reinforced Seams - Restoration Coating Fully Reinforced System w/ Reflective Top Coat (3 Gallons per Sq. of Restoration Coating - Reinforcement - Additional 3 Gallons per Sq. of Restoration Coating; Allow 30 Day Cure and Install Reflective Coating at 1 Gallon per Sq. (New 15.29 Flashings also Required Refer to Flashing Line Item) SF 8.44 REINFORCING SEAMS WITH SINGLE -COMPONENT URETHANE Reinforce Seams by Applying a Single -Component, Aliphatic Urethane 2 Gallons per Square / Reinforcement / 1 Gallons 15.30 per Square (3 Gallons per Square on Seams) LF 10.39 REINFORCING SEAMS WITH TWO -COMPONENT, LOW-ODER URETHANE Reinforce Seams by Applying a Two -Component, Low -Oder Urethane 2 Gallons per Square / Reinforcement / 1 Gallons 15.31 per Square (3 Gallons per Square on Seams) LF 10.98 STRIPPING IN SEAMS WITH SINGLE -COMPONENT URETHANE 15.32 Strip in Seams by Applying a Single -Component, Aliphatic Urethane 2 Gallons per Square LF 3.28 STRIPPING IN SEAMS WITH TWO -COMPONENT, LOW-ODER URETHANE 15.33 Strip in Seams by Applying a Two -Component, Low Odor Urethane 2 Gallons per Square LF 3.83 u 16.00 INSTALLATION OFSHAKE, TILE, OR SHINGLE ROOF SYSTEMS INSTALL NEW THREE -TAB SHINGLE ROOF SYSTEM - New Three -Tab Shingles with Base Sheet as an Underlayment; Install Self -Adhering Underlayment on All Eaves, Peaks 16.01 & Valleys SF 6.46 REPLACING ARCHITECTURAL SHINGLE ROOF SYSTEM - New Dimensional Shingle Roof System with Base Sheet as an Underlayment, Install Self -Adhering Underlayment on All 16.02 Eaves, Peaks & Valleys SF 7.16 INSTALL NEW DIMENSIONAL SHINGLE ROOF SYSTEM - New Dimensional Shingle Roof System with Base Sheet as an Underlayment; Install Self -Adhering Underlayment on All 16.03 Eaves, Peaks & Valleys SF 7.11 INSTALL NEW CEDAR SHAKE ROOF SYSTEM - New Cedar Shake Roof System with Base Sheet as an Underlayment; Install Self -Adhering Underlayment on All Eaves, 16.04 Peaks & Valleys SF 16.45 INSTALL NEW BARREL CLAY/CEMENT TILE ROOF SYSTEM - New Barrel Clay/Cement Tile Roof System with Base Sheet as an Underlayment; Install Self -Adhering Underlayment on 16.05 All Eaves, Peaks & Valleys SF 23.67 INSTALL SLATE TILE ROOF SYSTEM - New Slate Tile Roof System with Base Sheet as an Underlayment; Install Self -Adhering Underlayment on All Eaves, 16.06 Peaks & Valleys SF 24.53 ADD/DEDIUCT TO INSTALL SELF -ADHERING UNDERLAYMENT OVER ENTIRE ROOF - 16.07 Install Self -Adhering Underlayment on Entire Roof Deck SF 2.15 17A0„ e FULLY ADHERED $INOLE-PLY ROOF SYSTEMS; 17.01 �E METAL DECK • SINGLE -PLY APPLICATION Mechanically Fasten Polyisocyanurate / Adhere 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck Securock / Equal) with Insulation Adhesive to Provide an Average R-Value 17.01.01 INSULATION OPTION: of 20 1SF 5.08 17.02 WOOD/TECTUM DECK • SINGLE -PLY APPLICATION 99 WOOD DECK: Mechanically Fasten Polyisocyanu rate / Adhere Treated 1/2" Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value 17.02.01 INSULATION OPTION: of 20 SF 5.08 TECTUM DECK: Mechanically Attach Base Sheet & Adhere Polyisocyanurate in Insulation Adhesive / Adhere 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) in Insulation Adhesive to Provide 17.02.02 INSULATION OPTION: an Average R-Value of 20 SF 9.44 Without Insulation - Must Include Rosin & Mechanically Fasten Glass Base 17.02.03 INSULATION OPTION: Sheet SF 1.30 17.03 LIGHTWEIGHT CONCRETE/GYPSUM DECK - SINGLE•PLY APPLICATION Adhere Polyisocyanurate in Insulation Adhesive / Adhere 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) in Insulation Adhesive to Provide an 17.03.01 INSULATION OPTION: Average R-Value of 20 SF 9.44 Without Insulation - Must Include Rosin & Mechanically Fasten Glass Base 17.03.02 INSULATION OPTION: Sheet SF 1.85 17.04 CONCRETE DECK -SINGLE-PLY APPLICATION Adhere Polyisocyanurate in Insulation Adhesive / Adhere 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock / Equal) in Insulation Adhesive to Provide an 17.04.01 INSULATION OPTION: Average R-Value of 20 SF 7.06 Minimal Insulation - Must Adhere 1/2" Treated Gypsum Insulation Board with Glass -Mat (e.g. DensDeck / Securock ! Equal) in Insulation Adhesive to Provide 17.04.02 INSULATION OPTION: an Average R-Value of 20 SF 2.12 ROOF CONFIGURATION: r;. 17.05 Fully Adhered Single -Ply Roof System Installed Over Prepared Surface or Insulation ASTM D 4637 - Ethylene Propylene Diene Terpolymer (EPDM) - 45 Mil 17.05.01 SINGLE -PLY ROOF TYPE: Thickness SF 2.04 ASTM D 4637 - Ethylene Propylene Diane Terpolymer (EPDM) - 60 Mil 17.05.02 SINGLE -PLY ROOF TYPE: Thickness SF 4.85 ASTM D 4637 - Ethylene Propylene Diene Terpolymer (EPDM) - 90 Mil 17.05.03 SINGLE -PLY ROOF TYPE: Thickness SF 5.38 ASTM D 6878 - Thermoplastic Polyolefin 17.05.04 SINGLE -PLY ROOF TYPE: (TPO) - 45 Mil Thickness SF 1.83 ASTM D 6878 - Thermoplastic Polyolefin 17.05.05 SINGLE -PLY ROOF TYPE: (TPO) - 60 Mil Thickness SF 4.45 ASTM D 6878 - Thermoplastic Polyolefin 17.05.06 SINGLE -PLY ROOF TYPE: (TPO) - 90 Mil Thickness SF 6.41 ASTM D 4434 - Poly Vinyl Chloride 17.05.07 SINGLE -PLY ROOF TYPE: (PVC) - 45 Mil Thickness SF 2.63 ASTM D 4434 - Poly Vinyl Chloride 17.05.08 SINGLE -PLY ROOF TYPE: (PVC) - 60 Mil Thickness SF 5.52 ASTM D 4434 - Poly Vinyl Chloride 17.05.09 SINGLE -PLY ROOF TYPE: (PVC) - 90 Mil Thickness SF 6.68 100 ASTM D 6754 - Ketone Ethylene Ester 17.05.10 SINGLE -PLY ROOF TYPE: (KEE) - 45 Mil Thickness SF 3.50 ASTM D 6754 - Ketone Ethylene Ester 17.05.11 SINGLE -PLY ROOF TYPE: (KEE) - 60 Mil Thickness SF 8.44 ASTM D 6754 - Ketone Ethylene Ester 17.05.12 SINGLE -PLY ROOF TYPE: (KEE) - 80 Mil Thickness SF 9.64 Add / Deduct for Mechanically Attaching Single -Ply Roof System Vs. Fully 17.05.13 INSTALLATION OPTION: Adhering SF -0.50 Cost to Provide 15 Year - Material Warranty Limited to the Dollar Amount of the Material Original Purchase as a Standard Warranty for All Applications in this Section 17.05 Must includes coverage for roof uplift 17.05.15 WARRANTY CHARGES: pressures up to 90 MPH SF NSP Add to provide coverage for a 15 Year Labor & Material Warranty with No Dollar 17.05.16 WARRANTY UPCHARGE: Limitations SF NSP Add to provide coverage for a 20 Year Labor & Material Warranty with No Dollar 17.05.17 WARRANTY UPCHARGE: Limitations SF 0.15 Add to provide coverage for roof uplift 17.05.18 WARRANTY UPCHARGE: pressures up to 120 MPH SF NSP-2 FLUID, APPLIED -WATERPROOFING MEMBRANE SYSTEMSWITH_rr . 1800; POLYURETHANE;RESIN_COATINGS POLYURETHANE COATINGS DIRECT TO PRIMED CONCRETE SUBSTRATE (INCLUDE PRIMER FOR CONCRETE 18.01 SUBSTRATE) 18.01.01 FLUID APPLIED MEMBRANE SYSTEM: Two Coat System SF 12.47 18.01.02 FLUID APPLIED MEMBRANE SYSTEM: Three Coat System SF 15.48 18.01.03 FLUID APPLIED MEMBRANE SYSTEM: Three Coat Reinforced System SF 17.51 18.01.04 FLUID APPLIED MEMBRANE SYSTEM: Four Coat Reinforced System SF 21.98 5 Year Waterproofing Material Warranty Limited to the Dollar Amount of the Material Original Purchase as a Standard Warranty for All Applications in this 18.01.05 WARRANTY CHARGES: Section 18.01 SF NSP 10 Year Waterproofing Material Warranty Limited to the Dollar Amount of the Material Original Purchase as a Standard Warranty for All Applications in this 18.01.06 WARRANTY CHARGES: Section 18.01 SF NSP 18.02 POLYURETHANE COATINGS DIRECT TO WOOD SUBSTRATE 18.02.01 FLUID APPLIED MEMBRANE SYSTEM: Two Coat System SF 9.51 18.02.02 FLUID APPLIED MEMBRANE SYSTEM: Three Coat System SF 11.89 18.02.03 FLUID APPLIED MEMBRANE SYSTEM: Three Coat Reinforced System SF 13.58 18.02.04 FLUID APPLIED MEMBRANE SYSTEM: Four Coat Reinforced System SF 16.96 5 Year Waterproofing Material Warranty Limited to the Dollar Amount of the Material Original Purchase as a Standard Warranty for All Applications in this 18.02.05 WARRANTY CHARGES: Section 18.02 SF NSP 10 Year Waterproofing Material Warranty Limited to the Dollar Amount of the Material Original Purchase as a Standard Warranty for All Applications in this 18.02.06 WARRANTY CHARGES: Section 18.02 SF NSP FLUID APPLIED WATERPROOFING MEMS AIESYSTE BASE-O POYURETTNE RESN3 CO>RETE_ imp—nd 18.03 _ SURFACE REPAIRS &�PREPARATION� 101 CONCRETE REPAIRS TO OVERHEAD SURFACES: 2"-4" DEPTH 18.03.01 Removal and replacement of damaged concrete to exclude substrate repair / re -installation SF 150.01 CONCRETE REPAIRS TO OVERHEAD SURFACES: FULL DEPTH 18.03.02 Removal and replacement of damaged concrete to exclude substrate repair / re -installation SF 728.14 CONCRETE REPAIRS TO VERTICAL SURFACES: 3"-5" DEPTH 18.03.03 Removal and replacement of damaged concrete to exclude substrate repair / re -installation SF 95.13 CONCRETE REPAIRS TO VERTICAL SURFACES - 5"-8" DEPTH 18.03.04 Removal and replacement of damaged concrete to exclude substrate repair / re -installation; includes reinforcement SF 149.46 CONCRETE REPAIRS TO VERTICAL SURFACES - FULL DEPTH 18.03.05 Removal and replacement of damaged concrete to exclude substrate repair / re -installation; includes reinforcement SF 655.33 CONCRETE REPAIRS TO HORIZONTAL SURFACES: 2"-4" DEPTH 18.03.06 Removal and replacement of damaged concrete to exclude substrate repair / re -installation SF 44.85 CONCRETE REPAIRS TO HORIZONTAL SURFACES - 4"-6" DEPTH 18.03.07 Removal and replacement of damaged concrete to exclude substrate repair / re -installation; includes reinforcement SF 50.28 CONCRETE REPAIRS TO HORIZONTAL SURFACES - FULL DEPTH 18.03.08 Removal and replacement of damaged concrete to exclude substrate repair / re -installation; includes reinforcement SF 86.96 GRINDING 18.03.09 Grind an existing coating SF 1.83 HANDHELD GRINDING 18.03.10 Grind an existing coating in areas that only can be done by hand SF 8.76 MILLING 18.03.11 Mill an existing coating 1/8 inch to 1/4 inch SF 3.65 PRESSURE WASHING - HORIZONTAL 18.03.12 Pressure washing horizontal surfaces with 2000 PSI or greater SF 0.74 PRESSURE WASHING -VERTICAL 18.03.13 Pressure washing horizontal surfaces with 2000 PSI or greater SF 1.31 SAND BLASTING 18.03.14 Sand blast an existing coating SF 5.11 SHOT BLASTING 18.03.15 Shot blast an existing coating SF 1.83 FLUID APPLIED WATERPROOFING MEMBRANE SYSTEM BASE ON POLYURETHANE RESINS - ANCILARY 18.04 REPAIRS & SURFACE PREPARATION STRUCTURAL EXPANSION JOINT 18.04.01 Installation or replacement of an expansion joint that is necessary for structural integrity LF 489.31 CAULKING JOINTS 18.04.02 Installation of caulking in joints. See caulking chart LF - ROUTING AND REMOVAL OF EXISTING CAULK 18.04.03 Rout and remove of existing caulk out of expansion joints LF 7.00 EPDXY INJECTION FOR CRACK REPAIR 18.04.04 Route cracks, drill holes every 18" inches, and inject and seal with epoxy LF 34.96 18.04.05 TAPE WOOD DECK JOINTS - INSTALLATION OF TAPE ON DECK JOINTS LF 1.40 18.04.06 WOOD SUBSTRATE REPLACEMENT - REMOVAL AND REPLACEMENT SF 8.30 FLUID APPLIED WATERPROOFING MEMBRANE SYSTEM BASE ON POLYURETHANE RESINS - ADDITIONAL 18.05_ OPTIONS FOR APPLICATION "& SURFACING INSTALL REINFORCEMENT IN COATING SYSTEM 18.05.01 Installation of reinforcement adjustment of coverage rates to accommodate reinforcement LF 1.96 BROADCAST GRANULES TO PROVIDE SKID RESISTANCE 18.05.02 Broadcast aggregate or granules to provide skid resistance in top coat LF 1.01 WALL,COATINGS FOR COATING WALK SYSTEMS,µ id ELASTOMERIC COATING FOR STUCCO WALL SYSTEM - 19.01 Base Coat of Coating @ 1 Gallon per Sq. I Top Coat @ 1 Gallon per Sq. Applied as Specified SF 6.57 ELASTOMERIC COATING FOR EFIS WALL SYSTEM - 19.02 Base Coat of Coating @ 1 Gallon per Sq. / Top Coat @ 1 Gallon per Sq. Applied as Specified SF 6.88 ELASTOMERIC COATING FOR CMU WALL SYSTEM - 19.03 Base Coat of Coating @ 1 Gallon per S ' / Top Coat @ 1 Gallon per Sq. Applied as Specified SF 7.49 ELASTOMERIC COATING FOR CONCRETE TILT WALL SYSTEM - 19.04 Base Coat of Coating @ 1 Gallon per Sq. / Top Coat @ 1 Gallon per Sq. Applied as Specified SF 6.24 _. '0y, {+xS z,.,.s{r 20 00 N W4S3O ,F ROOF LAS ING&FO� I AODIFIED &-CPA- TA CH ROOF SIf$TEMS g r Flashing �2 - � 9H 20.01 MffiilnuFn 1, PIy of Bas an nerai"Ca Sheet•,Installe In,;o AST D Type, III or.IV Aspha,t r j° ? 102 Separate Base & Top Ply: BASE PLY: SBS Modified Fiberglass Reinforced Base Flashing Ply w/ Tensile Strength of 100 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet 20.01.01 FLASHING OPTION: Material Type II - 80 Ibf/in tensile SF 14.56 BASE PLY: SBS Modified Fiberglass Reinforced Base Flashing Ply w/ Tensile Strength of 100 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - 220 20.01.02 FLASHING OPTION: Ibf/in tensile SF 15.68 BASE PLY: SBS Modified Fiberglass Reinforced Base Flashing Ply w/ Tensile Strength of 100 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 310 20.01.03 FLASHING OPTION: Ibf/in tensile SF 16.23 BASE PLY: SBS Modified Fiberglass Reinforced Base Flashing Ply w/ Tensile Strength of 100 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 500 20.01.04 FLASHING OPTION: Ibf/in tensile SF 17.14 BASE PLY: SBS Modified Fiberglass Reinforced Base Flashing Ply w/ Tensile Strength of 100 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 600 20.01.05 FLASHING OPTION: Ibf/in tensile SF 17.56 Separate Base & Top Ply: BASE PLY: SBS Modified Fiberglass Reinforced Base Flashing Ply wl Tensile Strength of 200 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet 20.01.01 FLASHING OPTION: Material Type II - 80 Ibf/in tensile SF 15.31 BASE PLY: SBS Modified Fiberglass Reinforced Base Flashing Ply w/ Tensile Strength of 200 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - 220 20.01.02 FLASHING OPTION: Ibf/in tensile SF 16.43 BASE PLY: SBS Modified Fiberglass Reinforced Base Flashing Ply w/ Tensile Strength of 200 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 310 20.01.03 FLASHING OPTION: Ibf/in tensile SF 16.99 BASE PLY: SBS Modified Fiberglass Reinforced Base Flashing Ply w/ Tensile Strength of 200 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 500 20.01.04 FLASHING OPTION: Ibf/in tensile SF 17.88 103 BASE PLY: SBS Modified Fiberglass Reinforced Base Flashing Ply w/ Tensile Strength of 200 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 600 20.01.05 FLASHING OPTION: Ibf/in tensile SF 18.31 BASE PLY: SBS Modified Polyester/Fiberglass Reinforced Base Flashing Ply - 300 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type II - 80 20.01.06 FLASHING OPTION: Ibf/in tensile SF 15.31 BASE PLY: SBS Modified Polyester/Fiberglass Reinforced Base Flashing Ply - 300 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - 220 20.01.07 FLASHING OPTION: Ibf/in tensile SF 16.43 BASE PLY: SBS Modified Polyester/Fiberglass Reinforced Base Flashing Ply - 300 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 310 20.01.08 FLASHING OPTION: Ibf/in tensile SF 16.99 BASE PLY: SBS Modified Polyester/Fiberglass Reinforced Base Flashing Ply - 300 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 500 20.01,09 FLASHING OPTION: Ibf/in tensile SF 17.88 BASE PLY: SBS Modified Polyester/Fiberglass Reinforced Base Flashing Ply - 300 Ibf/in tensile (ASTM D 5147); TOP PLY: ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 600 20.01.10 FLASHING OPTION: Ibf/in tensile SF 18.31 PER SQUARE FOOT COSTS - INSTALLING IN COLD PROCESS FLASHING ADHESIVE 20.01.11 Substitute Hot Asphalt Application for Cold Process Flashing Adhesive Application SF 7.28 PER SQUARE FOOT COSTS - INSTALLING IN COLD PROCESS FLASHING ADHESIVE 20.01.12 Substitute Hot Asphalt Application for No VOCs, 100% Solids Cold Process Flashing Adhesive Application SF 10.58 Torch Applied Flashings - 20.02 Minimum 1 Ply of Torch Base and Torch Mineral Cap Sheet; Torch Applied BASE PLY: SBS Modified Polyester/Fiberglass Reinforced Base Torch Applied Flashing Ply - 80 Ibf/inch tensile (ASTM D 5147); TOP PLY: ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 300 Ibflin Tensile 20.02.01 FLASHING OPTION: Torch Applied Membrane SF 20.55 Self -Adhering Flashings - `00 M�� r 20.03 Minimum 1 Ply Self -Adhering Base and Self -Adhering Mineral Cap Sheet; Self -Adhering 104 BASE PLY: SBS Polyester OR Fiberglass/Polyester OR Fiberglass Reinforced Self -Adhering Flashing Ply - 50 Ibf/ tensile (ASTM D 5147); TOP PLY: ASTM D 6161 (Polyester) OR 6162 (Fiberglass/Polyester) OR 6163 (Fiberglass) Self -Adhering Reinforced Modified Bituminous Membrane Type III - 20.03.01 IFLASHING OPTION: 1130 Ibf/in tensile SF 17.08 � " R`N Single Flashings = -Ply 20.04 Fully Adhered Single -Ply Roof Flashings Installed on Corresponding Single -Ply Roof Systems ASTM D 4637 - Ethylene Propylene Diane Terpolymer (EPDM) - 45 Mil 20,04.01 ROOF MEMBRANE OPTION: Thickness SF 8.26 ASTM D 4637 - Ethylene Propylene Diane Terpolymer (EPDM) - 60 Mil 20.04.02 ROOF MEMBRANE OPTION: Thickness SF 10.83 ASTM D 4637 - Ethylene Propylene Diene Terpolymer (EPDM) - 90 Mil 20.04.03 ROOF MEMBRANE OPTION: Thickness SF 12.55 ASTM D 6878 - Thermoplastic Polyolefin 20.04.04 ROOF MEMBRANE OPTION: (TPO) - 45 Mil Thickness SF 6.31 ASTM D 6878 - Thermoplastic Polyolefin 20.04.05 ROOF MEMBRANE OPTION: (TPO) - 60 Mil Thickness SF 8.84 ASTM D 6878 - Thermoplastic Polyolefin 20.04.06 ROOF MEMBRANE OPTION: (TPO) - 90 Mil Thickness SF 11.93 ASTM D 4434 - Poly Vinyl Chloride 20.04.07 ROOF MEMBRANE OPTION: (PVC) - 45 Mil Thickness SF 6.96 ASTM D 4434 - Poly Vinyl Chloride 20.04.08 ROOF MEMBRANE OPTION: (PVC) - 60 Mil Thickness SF 9.84 ASTM D 4434 - Poly Vinyl Chloride 20,04.09 ROOF MEMBRANE OPTION: (PVC) - 90 Mil Thickness SF 12.05 ASTM D 6754 - Ketone Ethylene Ester 20.04.10 ROOF MEMBRANE OPTION: (KEE) - 45 Mil Thickness SF 9.30 ASTM D 6754 - Ketone Ethylene Ester 20.04.11 ROOF MEMBRANE OPTION: (KEE) - 60 Mil Thickness SF 14.34 ASTM D 6754 - Ketone Ethylene Ester 20.04.12 ROOF MEMBRANE OPTION: (KEE) - 80 Mil Thickness SF 15.97 21.00 ` `" METAL 1AfALL PANEL SYSTEMS '> WALL; SYSTEM 21.01 Exposed Fastener Wall Panel System Bare Aluminum Panel Price - 21.01.01 THICKNESS OPTION: 0.032" Aluminum, 36" Wide Panels SF 5.61 Add for Bare Aluminum 0.040" 21.01.02 THICKNESS OPTION: Aluminum, 36" Wide Panels SF 1.24 21.01.03 PANEL WIDTH OPTION: Add for 32" Panel Width - Aluminum SF 1.13 Bare Galvalume Coated Steel or Equal 21.01.04 THICKNESS OPTION: Panel Price - 24 Ga, 36" Wide Panels SF 5.41 Bare Galvalume Coated Steel or Equal 21.01.05 THICKNESS OPTION: Panel Price -22 Ga, 36" Wide Panels SF 6.00 Add for 32" Panel Width - Galvalume 21.01.06 PANEL WIDTH OPTION: Coated Steel or Equal SF 1.12 Add for Standard Colors - Fluorocarbon Paint System Over Aluminum or 21.01.07 COLOR OPTION: Galvalume Coated Steel Or Equal SF 0.95 Add for Designer Colors - Fluorocarbon Paint System Over Aluminum or 21.01.08 COLOR OPTION: I Galvalume Coated Steel Or Equal SF 1 1.21 105 Add for Premium or Custom Colors - Fluorocarbon Paint System Over Aluminum or Galvalume Coated Steel Or 21.01.09 COLOR OPTION: Equal SF 1.32 Stainless Steel 21.01.10 THICKNESS OPTION: Panel Price - 24 Ga, 36" Wide Panels SF 23.13 Stainless Steel 21.01.11 THICKNESS OPTION: Panel Price -22 Ga, 36" Wide Panels SF 26.83 21.01.12 PANEL WIDTH OPTION: Add for 32" Panel Width - Stainless Steel SF 0.83 Copper 21.01.13 THICKNESS OPTION: Panel Price -16 Oz., 36" Wide Panels SF 24.75 Copper 21.01.14 THICKNESS OPTION: Panel Price - 20 Oz., 36" Wide Panels SF 30.31 21.01.15 PANEL WIDTH OPTION: Add for 32" Panel Width - Copper SF 0.83 Zinc 21.01.16 THICKNESS OPTION: Panel Price - 0.032", 36" Wide Panels SF 19.92 Zinc 21.01.17 THICKNESS OPTION: Panel Price - 0.040", 36" Wide Panels SF 25.08 21.01.18 PANEL WIDTH OPTION: Add for 32" Panel Width - Zinc SF 0.67 Over Girts; 3/4" of Expanded Polystyrene (Minimum 1.5 lbs./cft) Installed Between 21.01.19 PANEL INSTALLATION & INSULATION OPTION: Girts SF 8.50 Over Girts; Mechanically Fastened Polyisocyanurate with an Average R- 21.01.20 PANEL INSTALLATION & INSULATION OPTION: Value of 19 Installed Between Girts SF 10.80 Over Girts; Mechanically Attach Batten Fiberglass Insulation with an Average R- 21.01.21 PANEL INSTALLATION & INSULATION OPTION: Value of 19 Installed Between Girts SF 7.77 RAIN SCREEN CONFIGURATION: Over Steel Stud Wall - Exterior Gypsum Sheeting 1/2" to 5/8" Thickness, Air Barrier (Priced Separately Below), Rock Wool or Extruded Polystyrene Insulation (Priced Separately Below) & Metal Wall Panel Drainage, Ventilation and 21.01.22 PANEL INSTALLATION & INSULATION OPTION: Attachment System SF 11.20 RAIN SCREEN CONFIGURATION: Over Existing Wall Construction - Air Barrier (Priced Separately Below), Rock Wool or Extruded Polystyrene Insulation (Priced Separately Below) & Metal Wall Panel Drainage, Ventilation and 21,01.23 PANEL INSTALLATION & INSULATION OPTION: Attachment System SF 9.42 21.0 .24 PANEL INSTALLATION & INSULATION OPTION: Over Plywood; No Insulation SF 8.18 WALL SYSTEM 21.02 Concealed Fastener Wall Panel System -12" Wide Panels Bare Aluminum Panel Price - 21.02.01 THICKNESS OPTION: 0.032" Aluminum Thickness SF 6.65 Add for Bare Aluminum, 0.040" 21.02.02 THICKNESS OPTION: Aluminum SF 1.39 Bare Galvalume Coated Steel or Equal 21.02.03 THICKNESS OPTION: Panel Price - 24 Ga SF 6.46 Bare Galvalume Coated Steel or Equal 21.02.04 THICKNESS OPTION: Panel Price - 22 Ga SF 7.35 Add for Standard Colors - Fluorocarbon Paint System Over Aluminum or 21.02.05 COLOR OPTION: Galvalume Coated Steel Or Equal SF 0.95 Add for Designer Colors - Fluorocarbon Paint System Over Aluminum or 21.02.06 COLOR OPTION: Galvalume Coated Steel Or Equal I SF 1 1.21 106 Add for Premium or Custom Colors - Fluorocarbon Paint System Over Aluminum or Galvalume Coated Steel Or 21.02.07 COLOR OPTION: Equal SF 1.32 Stainless Steel 21,02.08 THICKNESS OPTION: Panel Price - 24 Ga Thickness SF 23.13 Stainless Steel 21.02.09 THICKNESS OPTION: Panel Price - 22 Ga Thickness SF 26.83 Copper 21.02.10 THICKNESS OPTION: Panel Price - 16 Oz Thickness SF 24.75 Copper 21.02.11 THICKNESS OPTION: Panel Price - 20 Oz Thickness SF 30.31 Zinc 21.02.12 THICKNESS OPTION: Panel Price - 0.032" Thickness SF 19.92 Zinc 21.02.13 THICKNESS OPTION: Panel Price - 0.040" Thickness SF 25.08 Over Girts; 3/4" of Expanded Polystyrene (Minimum 1.5 Ibs.lcft) Installed Between 21,02.14 PANEL INSTALLATION & INSULATION OPTION: Girts SF 8.50 Over Girts; Mechanically Fastened Polyisocyanurate with an Average R- 21.02.15 PANEL INSTALLATION & INSULATION OPTION: Value of 19 Installed Between Girts SF 10.80 Over Girls; Mechanically Attach Batten Fiberglass Insulation with an Average R- 21.02.16 PANEL INSTALLATION & INSULATION OPTION: Value of 19 Installed Between Girts SF 7.77 21.02.17 PANEL INSTALLATION & INSULATION OPTION: Over Plywood; No Insulation SF 8.18 RAIN SCREEN CONFIGURATION: Over Steel Stud Wall - Exterior Gypsum Sheeting 1/2" to 5/8" Thickness, Air Barrier (Priced Separately Below), Rock Wool or Extruded Polystyrene Insulation (Priced Separately Below) & Metal Wall Panel Drainage, Ventilation and 21.02.18 PANEL INSTALLATION & INSULATION OPTION: Attachment System SF 11.20 RAIN SCREEN CONFIGURATION: Over Existing Wall Construction - Air Barrier (Priced Separately Below), Rock Wool or Extruded Polystyrene Insulation (Priced Separately Below) & Metal Wall Panel Drainage, Ventilation and 21.02.19 PANEL INSTALLATION & INSULATION OPTION: Attachment System SF 9.42 Add for Factory Insulated Concealed 21.02.20 PANEL TYPE OPTION: Fastener Wall Panel SF 3.83 AIR BARRIER FOR WALL APPLICATIONS (BRICK, CMU, MASONARY WALLS OR STUD WALL WITH EXTERIOR 21.03 GYPSUM SHEETING) 21.03.01 Non -Permeable Option: Fluid Applied System - ASTM 2178 SF 3.17 Fluid Applied Water Based System - 21.03.02 Non -Permeable Option: ASTM 2178 SF 3.00 21.03.03 Non -Permeable Option: Membrane System - ASTM E 2178 SF 2.93 Fluid Applied System - ASTM E 2178 & 21.03.04 Permeable Option: ASTM E 96 SF 2.99 Fluid Applied Water Based System - 21.03.05 Permeable Option: ASTM 2178 & ASTM E 96 SF 2.81 Membrane System - ASTM 2178 & 21.03.06 Permeable Option: ASTM E 96 SF 2.85 INSULATION FOR WALL APPLICATIONS (INSTALLED OVER AIR BARRIERS) 21.04 21.04.01 Insulation Option: 1" Rock Wool Insulation Installed SF 1.84 21.04.02 Insulation Option: 2" Rock Wool Insulation Installed SF 2.42 21.04.03 Insulation Option: 3" Rock Wool Insulation Installed SF 2.90 107 21.04.04 Insulation Option: 4" Rock Wool Insulation Installed SF 3.67 1" Extruded Polystyrene Insulation 21.04.05 Insulation Option: Installed SF 3.16 2" Extruded Polystyrene Insulation 21.04.06 Insulation Option: Installed SF 4.24 3" Extruded Polystyrene Insulation 21.04.07 Insulation Option: Installed SF 5.45 4" Extruded Polystyrene Insulation 21.04.08 Insulation Option: Installed SF 6.72 JOB SITE SPECIFIC MULTIPLIERS The multipliers are applied to all line items In total (unless the contrary Is specifically identified in the description) for the project because the conditions they address effect overall labor production, construction complexity and/or equipment requirements. Multiple Job Site Specific Multipliers can be used on a single project, but they are not meant to compound on each other. For Reference: Attachment B Pricing in this IFB is for material, equipment, tools, labor and supervision necessary to install the line item. It is based upon a 200 - 300 square roofing project that is being performed on a box- or rectangular -shaped building, it is also assumed that the project will have only one roof level that is not more than 20 ft high from the ground. The roof is anticipated to have clear access point and minimal penetrations/obstructions, It is also based upon a 200 - 300 square masonry, wall panel or waterproofing project. The exterior sides of the building are assumed to be box- or rectangular- shaped with minimal doors, windows, penetrations or obstructions. It is anticipated 22.00 that the sides of the building will have clear tie -off points and easy to access while work is being performed. MULTIPLIER - DIFFICULT ROOF OR BUILDING ACCESS Multiplier is applied when labor production is effected by roof or building access. Situations that can cause roof access to be more difficult include, but are not limited to: no access for lifts or cranes, access is dependent upon road closure, access point requires the closure of a building entrance, roof level is not accessible from the ground, roof area Is interior to adjacent roofs or roof materials and materials and equipment must be loaded to one roof area and carried to another roof area, roof materials and equipment must be carried to the roof through an interior building access point, no or 22.01 limited staging areas on the ground, etc. % 30.000 MULTIPLIER - SECURE ACCESS IS REQUIRED TO WORK ON ROOF OR WALLS Multiplier is applied when labor production is effected daily by the lost time in getting through security or getting access to the job site. Situations include, but are not limited to clearing each employee and all tools through metal detectors, passing through security gates with vehicles, tradespeople and equipment, stringent background checks or higher 22.02 clearance levels, etc. % 18.000 MULTIPLIER - MULTIPLE MATERIAL STAGINGS Multiplier is applied when labor production is effected by the time it takes to stage a roof multiple times. Situations include, but are not limited to staging materials to perform work on multiple roof levels, planned shutdowns and restarts, 22.03 portion of the job is over sensitive work areas requiring staging from more than one point, etc. % 25.000 MULTIPLIER - ACCELERATED SCHEDULE Multiplier is applied when increased labor burdens are required due to an accelerated work schedule. Situations include, but are not limited to requiring multiple concurrent trade crews beyond what is normally expected for project size, work to 22.04 be performed on two (back-to-back) shifts, work requires larger than standard crew sizes, etc. % 28.000 MULTIPLIER - NIGHT, WEEKEND OR HOLIDAY WORKING HOURS Multiplier is applied when increased labor burdens are required due to working hours being limited to nights (equivalent of 22.05 13rd shift), weekends or holidays. % 32.000 MULTIPLIER - ROOF OR WALLS HAVE LARGE AMOUNT OF PENETRATIONS / ROOF TOP OBSTRUCTIONS Multiplier is applied when labor production is effected a large number of roof penetrations, a limited amount of open roof areas or low overhead clearance requiring more hand work. Situations include, but are not limited to rooftop penetrations like: soil stacks, sky lights, roof drains, exhaust vents, HVAC equipment, etc. or rooftop obstructions such as: pipes, duct 22.06 work, electrical wires, hoses or raised equipment, etc. % 35.000 MULTIPLIER - CLEARENCE RESTRICTIONS REQUIRE WORKING FROM KNEE -LEVEL OR BELOW (APPLIES TO ONLY THE EFFECTED ROOF AREA) Multiplier is applied when labor production is effected by height restrictions. Situations that can cause low overhead 22.07 Iclearance requiring more hand work include, but are not limited to rooftop equipment. % 35.000 MULTIPLIER - ROOF HEIGHT IS GREATER THAN 20 FT, BUT LESS THAN OR EQUAL TO 50 FT STORIES Multiplier is applied when labor production is effected by the roof height. This multiplier applies to roof heights that exceed an estimated 2 stories, but are less than or equal to an estimated 5 stories. Additional roof height can require 22.08 increased safety requirements, larger lift equipment, tie -offs, etc. % 25.000 MULTIPLIER - ROOF HEIGHT IS GREATER THAN 50 FT, BUT LESS THAN OR EQUAL TO 100 FT Multiplier is applied when labor production is effected by the roof height. This multiplier applies to roof heights that exceed an estimated 5 stories, but are less than or equal to an estimated 10 stories. Additional roof height can require 22.09 increased safety requirements, larger crane equipment, tie -offs, etc. % 35.000 108 MULTIPLIER - ROOF HEIGHT IS GREATER THAN 100 FT Multiplier is applied when labor production is effected by the roof height. This multiplier applies to roof heights that exceed an estimated 10 stories. Additional roof height can require increased safety requirements, larger crane 22.10 tie -offs, etc. % 50.000 _equipment, MULTIPLIER - WALL COATING, MASONRY REPAIRS OR WATERPROOFING REQUIRES A SWING STAGE Multiplier is applied when labor production is effected by the requirement to use a swing stage. This multiplier applies to 22.11 wall coatings, masonry repairs or waterproofing work that requires the use of a swing stage. % 50,000 MULTIPLIER - ROOF IS CONSIDERED NON-STANDARD ARCHITECTURE Multiplier is applied when labor production is effected because the roof area Is not a box- or rectangular -shaped. Situations considered to be non-standard architecture can include, but are not limited roof areas that contains sharp 22.12 angles and/or curves, have multiple roof area dividers or expansion joints, long and narrow % 20.000 MULTIPLIER - ROOF HAS GREATER THAN 4/12 SLOPE Multiplier is applied when Roof Area has a Greater than 4/12 Slope, Steeper slope reduces overall labor production and 22.13 requires additional safety precautions. % 25.000 MULTIPLIER - ROOF HAS GREATER THAN 8112 SLOPE Multiplier is applied when Roof Area has a Greater than 8/12 Slope; Very steep slopes have a greater impact on overall 22.14 labor production and require additional safety precautions. % 45.000 MULTIPLIER - ROOF SIZE IS LESS THAN 500 SF Multiplier is applied when Roof Size is less than 500 SF. Situation creates the fixed costs: equipment, mobilization, demobilization, disposal, & set-up labor to be allocated across a very small roof area resulting in fixed costs having a 22.15 Isignificant impact on the overall job costs % 150.000 MULTIPLIER - ROOF SIZE IS GREATER THAN 500 SF, BUT LESS THAN 1,000 SF Multiplier is applied when Roof Size is greater than 500 SF, but less than 1,000 SF. Situation creates the fixed costs: equipment, mobilization, demobilization, disposal, & set-up labor to be allocated across a very small roof area resulting in 22.16 fixed costs having a significant impact on the overall job costs % 90.000 MULTIPLIER - ROOF SIZE IS GREATER THAN 1,000 SF, BUT LESS THAN 2,000 SF Multiplier is applied when Roof Size is greater than 1,000 SF, but less than 2,000 SF. Situation creates the fixed costs: equipment, mobilization, demobilization, disposal, & set-up labor to be allocated across a very small roof area resulting in 22.17 Ifixed costs having a significant impact on the overall job costs % 70.000 MULTIPLIER - ROOF SIZE IS GREATER THAN 2,000 SF, BUT LESS THAN 3,000 SF Multiplier is applied when Roof Size is greater than 2,000 SF, but less than 3,000 SF. Situation creates the fixed costs: equipment, mobilization, demobilization, disposal, & set-up labor to be allocated across a very small roof area resulting in 22.18 fixed costs having a significant impact on the overall job costs % 45.000 MULTIPLIER - ROOF SIZE IS GREATER THAN 3,000 SF, BUT LESS THAN 5,000 SF Multiplier is applied when Roof Size is greater than 3,000 SF, but less than 5,000 SF. Situation creates the fixed costs: equipment, mobilization, demobilization, disposal, & set-up labor to be allocated across a smaller roof area resulting in 22.19 fixed costs being a larger portion of the overall job costs % 30.000 MULTIPLIER - ROOF SIZE IS GREATER THAN 5,000 SF, BUT LESS THAN 10,000 SF Multiplier is applied when Roof Size is greater than 5,000 SF, but less than 10,000 SF. Situation creates the fixed costs: equipment, mobilization, demobilization, disposal, & set-up labor to be allocated across a smaller roof area resulting in 22.20 fixed costs being a larger portion of the overall job costs % 20.000 MULTIPLIER -ROOF SIZE IS GREATER THAN 10,000 SF, BUT LESS THAN 20,000 SF Multiplier is applied when Roof Size is greater than 10,000 SF, but less than 20,000 SF. Situation creates the fixed costs: equipment, mobilization, demobilization, disposal, & set-up labor to be allocated across more of an average roof area 22.21 Iresulting in fixed costs being a slightly larger portion of the overall job costs % 10.000 MULTIPLIER - ROOF SIZE IS GREATER THAN 30,000 SF, BUT LESS THAN 50,000 SF Multiplier is applied when Roof Size is greater than 30,000 SF, but less than 50,000 SF. Situation creates the fixed costs: equipment, mobilization, demobilization, disposal, & set-up labor to be allocated across a larger than average roof area 22.22 resulting in fixed costs being a lower portion of the overall job costs % -3.000 MULTIPLIER -ROOF SIZE IS GREATER THAN 50,000 SF, BUT LESS THAN 100,000 SF Multiplier is applied when Roof Size is greater than 50,000 SF, but less than 100,000 SF. Situation creates the fixed costs: equipment, mobilization, demobilization, disposal, & set-up labor to be allocated across a large roof area resulting 22.23 lin fixed costs being a small impact on the overall job costs % -5.000 MULTIPLIER - ROOF SIZE IS GREATER THAN 100,000 SF, BUT LESS THAN 200,000 SF Multiplier is applied when Roof Size is greater than 100,000 SF, but less than 200,000 SF. Situation creates the fixed costs: equipment, mobilization, demobilization, disposal, & set-up labor to be allocated across larger roof area resulting in 22.24 fixed costs being a slight impact on the overall job costs % -6.000 MULTIPLIER - ROOF SIZE IS GREATER THAN 200,000 SF Multiplier is applied when Roof Size is greater than 200,000 SF. Situation creates the fixed costs: equipment, mobilization, demobilization, disposal, & set-up labor to be allocated across very large roof area resulting in fixed costs 22.25 lbeing a minimal impact on the overall job costs I % -8.000 109 IFB #PW1925 Roofing Supplies and Services, Waterproofing, and Related Products and Services Attachment C - Bid Form 23.01 Cleaning & Caulking Pressure Wash to Clean Horizontal Surfaces SF $ 0.77 23.02 Pressure Wash to Clean Vertical Surfaces SF $ 1.77 23.03 Pressure Wash with TSP or Simple Green to Clean Horizontal Surfaces SF $ 1.10 23.04 Pressure Wash with TSP or Simple Green to Clean Vertical Surfaces SF $ 2.12 23.05 Use a Brush to Wash Surface with TSP or Simple Green to Clean Horizontal Surfaces SF $ 0.93 23.06 Use a Brush to Wash Surface with TSP or Simple Green to Clean Vertical Surfaces SF $ 1.94 23.07 Prime Existing Asphalt -Based Roof Surface SF $ 0.54 23.08 Blow -Off Surface Area with Portable Blower to Remove Moisture SF $ 0.38 23.09 Spud and Scrape Aggregate from Roof Surface Asphalt BUR (Size Reference: 100' X 12") SF $ 1.55 23.10 Spud and Scrape of Aggregate from Roof Surface Coal Tar BUR (Size Reference: 100' X 12") SF $ 2.13 23.11 Remove & Dispose Loose Aggregate from Roof Surface (Wet Vac) SF $ 1.22 23.12 Power Broom Roof Surface SF $ 0.68 23.13 Remove & Dispose Ballast from Roof Surface SF $ 1.10 23.14 Remove & Dispose Ballast from Roof Surface at Approved Disposal Site SF $ 2.06 23.15 Remove Ballast from Roof Surface & Save for Reuse SF $ 0.71 23.16 Scrape / Sand Loose Paint from Exterior Building Surfaces and Clean -Up Debris SF $ 4.70 23.17 Sandblasting Paint from Exterior Building Surfaces and Re -Claim Sand SF $ 5.76 23.18 Apply Coating (Paint) to Horizontal Surface SF $ 3.78 23.19 Apply Coating (Paint) to Vertical Surface SF $ 5.37 23.20 Caulking: Remove Existing Caulking & Clean and Prime Joint LF $ 2.12 23.21 Install Backer Rod in Properly Prepared Opening, Polyethylene - 3/8" Diameter LF $ 1.32 23.22 Install Backer Rod in Properly Prepared Opening, Polyethylene - 1/2" Diameter LF $ 1.63 23.23 Install Backer Rod in Properly Prepared Opening, Polyethylene - 3/4" Diameter LF $ 1.96 23.24 Install Backer Rod in Progerly Prepared O enin , Pol eth lene - 1" Diameter LF UNIT $ 2.23 Unit 23.25 Masonry section Remove and Reset Bricks; 1-50 SF SF $ per $ 33.87 23.26 Remove and Reset Bricks; Over 50 SF SF $ 26,37 23.27 Remove and Reset Blocks SF $ 18.64 23.28 Remove and Reset Coping Stones Each $ 39.81 23.29 Remove Bricks, Blocks, Coping Stones; 1-50 SF SF $ 27.20 23.30 Remove Bricks, Blocks, Coping Stones; Over 50 SF SF $ 21.69 23.31 Brick, block and brick exterior wall maintenance, repair and application of protective coatings. Selective Demolition of Concrete Block Masonry Units (CMU) with perimeter saw cutting- swing stage 4", 6" and 8" block (high-rise) UNIT Each $ per Unit $ 17.23 23.32 ISelective Demolition of Brick Mason Units with perimeter saw cutting SF $ 28.96 Selective •• Removal of existing mortar '/2" wide by 3/" depth)SF per Unit $ 12.28 23.34 Removal of existing mortar (%" wide by 3/" depth) SF $ 16.38 23.35 Removal of existing mortar 'W' wide by 1'%" depth SF $ 19.44 23.36 Removal of existing mortar (%" wide by 1'/2" depth SF $ 25.58 23.37 PointingNew Furnish and install new mortar '/Z' wide by 3/a" depth)SF $ 24.55 23.38 Furnish and install new mortar 3/4" wide by 3/" depth SF $ 27.62 23.39 Furnish and install new mortar ('/2" wide by 1 '/2' depth) SF $ 28.65 23.40 Furnish and install new mortar 3/" wide by 1 '/z' depth SF UNIT $ 32.74 Unit 23.41 Removal of Roof Parapets Removal of parapet wall (24" high) SF $ per $ 255.82 23.42 Removal of parapet wall 42" high SF $ 460.45 23.43 Removal of parapet wall 24" high) SF $ 214.89 23.44 Removal of parapet wall 42" hi h SF $ 429.76 Reconstruction of Brick Masonry Roof Parapetsper New brick masonry parapet w/stone coping and flashings 24" high)SF Unit $ 716.24 23.46 New brick masonry parapet w/stone coping and flashings (42" high) SF $ 972.05 23.47 New brick masonry parapet w/stone coping and flashings 24" high) SF $ 511.60 23.48 New brick masonry parapet w/stone coping and flashings (42" high) SF $ 665.09 Unit 23.49 New Through wall Flashings Removal of 4 courses brick wall w/Temporary Shoring UNIT SF $ per $ 102.33 23.50 Removal and replacement of steel lintel SF $ 153.49 23.51 Furnish and install new flashings (Bituthane) SF $ 40.93 140 23.52 1 Furnish and install new flashings (Lead coated copper) I SF 1 $ 81.85 141 23.53 Furnish and Install New Brick Masonryw/Wee Holes and Screens SF $ 153.4 1 23.54 Par in and waterproofin of back-up wall SF UNIT $ 57.29 Unit $ Roof Coping Stones. Removal of existing roof coping stones (16 inches) SF per 1 $ 284.37 23.56 Removal and parging of existing substrate SF $ 89.38 23.57 Furnish and install new lead coated copper flashings SF $ 89.38 23.58 Drilling and epoxy grouting stainless steel pins SF $ 203.12 23.59 Reinstallation of existing stones with cleaning SF $ 146.25 23.60 Furnish and install new coping stones SF $ 528.11 23.61 Furnish and install new sealants between coping stones. SF $ 45.01 23.62 lCleanina and coatino of existina stones. SF 23.63 RepairCMU Backup Wall .. lReplacement of Deteriorated CMU Back-up SF $ 172,70 23.64 IParging of CMU back-up wall SF $ 53.05 23.65 lWaterproofinpof back-up wall SF I $ 45.75 23.66 RepairCrack 1 Drill and install new stainless steel pins. Each 23.67 Grouting of open cracks SF $ 52.98 23.68 1 Re lacement of cracked bricks SF UNIT $ 103.25 $ Unit 23.69 New Concrete and Coating Placement of new high strength patching mortar (2" depth) SF per 1$ 235.45 23.70 Placement of new high strength patching mortar 3.5" depth). SF $ 278.84 23.71 Cleaning and coating of concrete surface. SF $ 21.53 23.72 Sidewalk Bridging. SF $ 7.72 23.73 Tempora Roof Protection SF $ 6.10 23.74 PocketsRoof Drainage, Scuppers, Stacks, Curbs and Pitch Install & Connect new 4" roof drain & Flashing; Excluding Plumbing EA $ 974.97 23.75 Install & Connect new 6" roof drain & Flashing; ExcludingPlumbingEA $ 1,5656.22 23.76 Install & Connect new 8" roof drain & Flashing; ExcludingPlumbingEA $ 1,137.47 23 77 Pitch pocket, 24 gauge, GI, 12" x 12", with storm collar, hemmed to outside, soldered corners and seams EA $ 909.97 23 78 Pitch pocket, 24 gauge, GI, 6" x 6", with storm collar hemmed to outside, soldered corners and seams EA $ 617.48 23.79 Pitch pocket, 24 gauge, GI, 8" x 8", with storm collar, hemmed to outside, soldered corners and seams EA $ 714.98 23.80 Plumbing stack, 16 oz. copper flashing EA $ 211.24 23.81 Plumbing stack, 24 gad Zinc flashing EA $ 292.49 23.82 Plumbing stack, 4# lead flashing EA $ 178.74 23.83 Pre -Cast Molded Pitch Pan (e.g. Chemcurb) - 12" Straight EA $ 48.75 23.84 Pre -Cast Molded Pitch Pan e.g. Chemcurb - 2" Corners EA $ 45.49 23.85 Pre -Cast Molded Pitch Pan (e.g, Chemcurb - 3" Kit EA $ 146.25 23.86 Pre -Cast Molded Pitch Pan (e.g. Chemcurb) - 5" Kit EA $ 191.74 23.87 Pre -Cast Molded Pitch Pan (e.g. Chemcurb) - 5" Rounds EA $ 56.88 23.88 Pre -Cast Molded Pitch Pan e.g. Chemcurb - 6" Kit EA $ 217.74 23,89 Pre -Cast Molded Pitch Pan (e.g. Chemcurb) - 6" Straight EA $ 42.25 23.90 Pre -Cast Molded Pitch Pan (e.g. Chemcurb - 7.5" Kit EA $ 258.37 23.91 Pre -Cast Molded Pitch Pan (e.g. Chemcurb) - 7.5' Kit with 2-Part Filler EA $ 315.24 23.92 Pre -Cast Molded Pitch Pan (e.g. Chemcurb - 7.5" Rounds EA $ 66.62 23.93 Pre -Cast Molded Pitch Pan (e.g. Chemcurb - 9" Kit EA $ 430.62 23.94 Installation of Roof Curbs 2" X 4" LF $ 7.00 23.95 Installation of Roof Curbs 2" X 6" LF $ 7.52 23.96 lInstallation of Roof Curbs 2" X 8" LF $ 8.03 23.97 Installation of Coping/Edge Nailers 2" X 4" LF $ 4.39 23.98 Installation of Coping/Edge Nailers 2" X 6" LF $ 4.90 23.99 Installation of Coping/Edge Nailers 2" X 8" LF $ 5.39 23.100 Installation of Coping/Edge Nailers 2" X 10" LF $ 6.42 23.101 Installation of Coping/Edge Nailers 2" X 12" LF $ 7.94 23.102 Installation of Coping/Edge Nailers 2" X 14" LF $ 10.81 23.103 Installation of Coping/Edge Nailers 2" X 16" LF $ 11.83 23.104 Provide a cast iron drain strainer EA $ 235.62 23.105 Reflash existing roof drain EA $ 909.97 23.106 Scupper, .050 Aluminum, match existing configuration LF $ 17.99 142 23.107 Scupper, 16 oz Copper, match existing configuration LF $ 34.07 23.108 IScupper, 20 gad Stainless Steel, match existing configuration LF $ 28.39 23.109 1 Sleeper Ca - 24 Gad Galvanized LF UNIT $ 10.98 Unit $ 23.110 Roof Accessories Walkwa Pads per 23.111 30" wide roll goods, tape attached EA $ 1,543.70 23.112 30" wide roll, hot asphalt attached EA $ 1,218.71 23.113 30" wide roll, adhesive attached EA $ 1,462.46 23.114 Expansion joint, butyl or neoprene bellows, galvanized flange LF $ 31.68 ladder, security ladderguard EA $ 2,843.66 Roof ladder, steel, bolted to concrete, 20 feet and up, with cage; with intermediate landings asEA required by Code $ 6,499.80 k231Roof Roof ladder, steel, bolted to concrete, up to 20 feet, without cageEA Roof ventilatorsEA M4.47 Termination bar, aluminum, 1/4" x 1" LF UNIT Unit $ 23.120 Common Roof Repair Items 3-Course Application; Mastic -Mesh -Mastic; 15" Wide Total; 12" Wide Mesh LF per $ 10.71 23.121 3-Course Application; Mastic -Mesh -Mastic; 9" Wide Total; 6" Wide Mesh LF $ 6.26 23.122 3-Course Application; Urethane -Reinforcement -Urethane < 500 SF SF $ 16.12 23.123 3-Course Application; Urethane -Reinforcement -Urethane > 500 SF SF $ 14.04 23.124 Install Self -Adhering Cap Sheet Over Repair Area < 500 SF SF $ 8.71 23.125 Install Self -Adhering Cap Sheet Over Repair Area > 500 SF SF $ 7.62 23.126 Torch Cap Sheet Over Repair Area < 500 SF) SF $ 11.40 23.127 Torch Cap Sheet Over Repair Area (> 500 SF) SF $ 10.59 23.128 Set Roofing Cap Sheet Membrane in Mastic Installed Over Repair Area (< 500 SF) SF $ 12.12 23,129 Set Roofing Cap Sheet Membrane in Mastic Installed Over Repair Area > 500 SF SF $ 11.22 Unit 23.153 ResponseLeak Leak Response Work Order Tracking & Dispatch EA per NSP 23.154 Leak Response Completion Report with Back -Up EA NSP 23.155 Preventive Maintenance (Single Campus - All Roof Sections) SF $ 0.058 23.156 Preventive Maintenance (Multiple Campuses City -/County -wide - All Roof Sections) SF $ 0.078 23.157 Preventive Maintenance (Multiple Campuses State-wide - All Roof Sections) SF $ 0,072 23.155 Preventive Maintenance Performed Concurrent with Visual Inspection (Single Campus - All Roof Sections) SF $ 0.035 23.156 Preventive Maintenance Performed Concurrent with Visual Inspection (Multiple Campuses City- /County -wide - All Roof Sections) SF $ 0.055 23.157 Preventive Maintenance Performed Concurrent with Visual Inspection (Multiple Campuses State-wide - All Roof Sections) SF $ 0.049 23,158 Preventive Maitenance Com letion Re ort with Back -Up EA UNIT NSP $ Unit 23.159 Equipment Folklift/Manlift Equipment Rental DAY I per NSP 23.160 Crane Equipment Rental - up to 80' DAY NSP 23.161 Crane Equipment Rental - up to 150' DAY NSP 23.162 Manlift per day DAY NSP 23.163 Skytrack DAY NSP 23,164 Additional E ui ment rental % off ublished rice % 10% 23.165 Other Services Demobilization - Pre -Planned or Additional Un-planned UNIT EA $ per Unit $ 1,725.00 23.166 Remobilization - Pre -Planned or Additional Un- lanned EA $ 1,725.00 23.167 Additional.. options Option 1: Cost of Quote Plus Mark -Up (Used when repair and installation services line item pricing is not available and services performed are to be performed by a contractor. Requires a quote on corporate letterhead that cannot exceed $25,000) Cost plus added to quote % 14% 23,168 Option 2: R.S. Means or Gordian Group Catalog (Used when repair and installation services line item pricing is not available) Cost plus added to catalog pricing % UNIT 14% $ Unit 23.169 Catalog Pricing Please provide a price list with your complete material catalog(s) - A manufacturers catalog can be used. You may provide a net -price or a catalog with a discount. UNIT per 1 % $ Green Roofing per 143 23.170 Please provide your green environmentally friendly roofing options, please provide as much §CE.A.3.1.F..4. & information as possible to include line items necessary to complete a green roof § 144 IFB #PW1925 Roofing Supplies and Services, Waterproofing, and Related Products and Services Attachment C - Bid Form Sheet Metal Accessories Covered Under these Pricing Tables: -Drip Edge -Gravel Stop -Gutters, Straps, Hangers & Fasteners -Coping -Surface Mounted Counter Flashing -Reglet Mounted Counter Flashing -Skirt Flashing -Expansion Joints -Miscellaneous Metal Fabricated Details Aluminum Size I Gauge .032 .040 .050 .063 6" $9.27 $10.12 $10.45 $11.29 8" $10.67 $11.79 $12.22 $13.35 10" $12.05 $13.44 $14.00 $15.41 12" $13.43 $15.12 $15.78 $17.46 14" $14.81 $16.78 $17.55 $19.52 16" $16.20 $18.45 $19.32 $21.57 18" $17.35 $19.85 $20.80 $23.30 20" $18.72 $21.48 $22.56 $25.32 22" $20.08 $23.10 $24.30 $27.35 24" $20.98 $24.21 $25.46 $28.68 26" $22.31 $25.78 $27.15 $30.65 28" $23.62 $27.39 $28.84 $32.60 30" $24.96 $28.97 $30.54 $34.58 32" $26.27 $30.57 $32.23 $36.54 34" $27.58 $32.15 $33.93 $38.50 36" $28.44 $33.19 $35.05 $39.79 38" $29.75 $34.75 $36.70 $41.72 40" $31.04 $36.32 $38.35 $43.63 42" $32.34 $37.88 $40.03 $45.56 44" $33.64 $39.43 $41.69 $47.48 46" $34.80 $40.81 $43.17 $49.20 48" $35.91 $42.19 $44.62 $50.90 Price Per Bend $0.40 $0.40 $0.60 $0.60 145 Stainless Steel & Copper Size (Gauge /Thickness SS 24 Ga SS 26 Ga Copper 16 oz Copper 20 oz 6" $10.87 $10.29 $12.17 $13.34 8" $12.78 $11.99 $14.51 $16.08 10" $14.70 $13.72 $16.86 $18.80 12" $16.62 $15.44 $19.21 $21.56 14" $18.54 $17.17 $21.56 $24.29 16" $20.45 $18.89 $23.89 $27.01 18" $22.06 $20.33 $25.86 $29.33 20" $23.94 $22.02 $28.15 $31.99 22" $25.82 $23.71 $30.46 $34.70 24" $27.07 $24.83 $31.99 $36.49 26" $28.89 $26.47 $34.22 $39.09 28" $30.74 $28.13 $36.49 $41.70 30" $32.56 $29.76 $38.72 $44.32 32" $34.39 $31.40 $40.95 $46.93 34" $36.20 $33.04 $43.18 $49.54 36" $37.42 $34.13 $44.67 $51.27 38" $39.22 $35.73 $46.85 $53.82 40" $41.00 $37.34 $49.06 $56.38 42" $42.80 $38.96 $51.27 $58.95 44" $44.59 $40.56 $53.46 $61.51 46" $46.20 $41.99 $55.41 $63.79 48" $47.76 $43.41 $57.34 $66.03 Price Per Bend $0.60 $0.40 $0.40 146 Kynar Coated Steel Size / Gauge 16 Ga 20 Ga 22 Ga 24 Ga 6" $12.41 $12.02 $11.71 $11.48 8" $13.71 $13.16 $12.77 $12.44 10" $15.00 $14.33 $13.81 $13.42 12" $16.28 $15.49 $14.87 $14.41 14" $17.56 $16.64 $15.92 $15.38 16" $18.86 $17.80 $16.99 $16.35 18" $19.93 $18.76 $17.86 $17.17 20" $21.21 $19.91 $18.92 $18.15 22" $22.48 $21.05 $19.93 $19.10 24" $23.31 $21.79 $20.63 $19.72 26" $24.54 $22.90 $21.64 $20.67 28" $25.78 $24.01 $22.64 $21.61 30" $27.01 $25.10 $23.64 $22.53 32" $28.24 $26.21 $24.67 $23.47 34" $29.46 $27.32 $25.67 $24.41 36" $30.29 $28.05 $26.32 $25.01 38" $31.49 $29.13 $27.32 $25.92 40" $32.69 $30.21 $28.31 $26.85 42" $33.91 $31.29 $29.30 $27.76 44" $35.12 $32.36 $30.29 $28.67 46" $36.19 $33.35 $31.15 $29.50 48" $37.26 $34.29 $32.03 $30.29 Price Per Bend $0.60 $0.60 $0.40 $0.40 147 Galvanized Steel Size / Gauge 16 Ga 20 Ga 22 Ga 24 Ga 6" $11.35 $11.03 $10.74 $10.51 8" $12.28 $11.86 $11.48 $11.17 10" $13.23 $12.68 $12.20 $11.82 12" $14.17 $13.51 $12.95 $12.48 14" $15.11 $14.34 $13.69 $13.14 16" $16.04 $15.17 $14.42 $13.80 18" $16.82 $15.86 $15.04 $14.34 20" $17.76 $16.69 $15.76 $15.00 22" $18.68 $17.49 $16.48 $15.63 24" $19.29 $18.04 $16.97 $16.07 26" $20.19 $18.83 $17.66 $16.70 28" $21.08 $19.62 $18.35 $17.32 30" $21.98 $20.41 $19.06 $17.94 32" $22.86 $21.19 $19.76 $18.56 34" $23.77 $21.98 $20.46 $19.21 36" $24.35 $22.52 $20.92 $19.62 38" $25.24 $23.28 $21.61 $20.22 40" $26.12 $24.06 $22.31 $20.84 42" $26.99 $24.83 $22.99 $21.45 44" $27.86 $25.62 $23.69 $22.07 46" $28.65 $26.29 $24.29 $22.61 48" $29.42 $26.98 $24.91 $23.15 Price Per Bend $0.60 $0.60 $0.40 $0.40 148 IFB #PW1925 Roofing Supplies and Services, Waterproofing, and Related Products and Services Attachment C - Bid Form Caulking Chart pricing per Linear Foot Installed 2 Component Epoxied Urethane Compound • 1/8" 3/16" 1l4" 5/16" 3/18" 7116" 1/2" 5/8" 314" 7/8" 1" 1-1/8" 1-1/4" 1/8" $2.29 $2.39 $2.50 $2.58 $2.68 $2.86 $3.05 $3.25 $3.34 $3.54 $3.73 $4.20 $4.39 3/16" $2.39 $2.50 $2.58 $2.68 $2.78 $2.86 $3.05 $3.34 $3.44 $3.54 $3.81 $4.30 $4.46 1/4" $2.50 $2.58 $2.58 $2.78 $2.86 $2.86 $3.25 $3.34 $3.44 $3.54 $3.92 $4.39 $4.57 5/16" $2.58 $2.68 $2.68 $2.86 $2.97 $3.05 $3.34 $3.44 $3.44 $3.54 $4.01 $4.46 $4.67 3/18" $2.68 $2.78 $2.78 $2.97 $3.05 $3.25 $3.44 $3.54 $3.44 $3.62 $4.20 $4.57 $4.77 7/16" $2.86 $2.86 $2.86 $3.05 $3.25 $3.34 $3.54 $3.62 $3.62 $3.73 $4.30 $4.67 $4.85 1/2" $3.05 1 $3.05 $3.05 $3.25 $3.34 $3.44 1 $3.62 $3.73 $3.81 1 $3.81 $4.39 $4.77 $4.96 5/8" $3.25 $3.34 $3.34 $3.34 $3.44 $3.54 $3.73 $3.81 $3.92 $3.92 $4.46 $4.85 $5.04 3/4" $3.34 $3.44 $3.44 $3.44 $3.54 $3.62 $3.81 $3.92 $4.01 $4.01 $4.57 $4.96 $5.15 7/8" $3.54 $3.54 $3.54 $3.73 $3.62 $3.73 $3.92 $4.01 $4.20 $4.20 $4.67 $5.04 $5.34 1" $3.73 $3.81 $3.81 1 $3.92 $3.92 $4.01 $4.01 $4.20 $4.30 $4.39 $4.77 $5.15 $5.43 1-1/8" $4.20 $4.30 $4.30 $4.39 $4.46 $4.46 $4.57 $4.67 $4.67 $4.77 $4.85 $5.34 $5.53 1-1/4" 1 $4.39 1 $4.46 $4.57 $4,67 1 $4.67 1 $4.67 1 $4.77 1 $4.85 1 $4.85 1 $4.96 1 $4.96 1 $5.43 $5.61 Caulking Chart pricing per Linear Foot Installed 1 Component Polvurethane • 1 /8" 3/16" 1 /4" 5/16" 3/18" 7/16" 1/2" 5/8" 3/4" 7/8" 1 " 1-1 /8" 1-1 /4" 1/8" $3.44 $3.62 $3.81 $3.92 $4.08 $4.39 $4.67 $4.85 $5.04 $5.34 $5.72 $6.30 $6.57 3/16" $3.62 $3.81 $3.92 $4.08 $4.39 $4.67 $4.85 $5.04 $5.34 $5.72 $6.30 $6.57 $6.75 1/4" $3.81 $3.92 $4.08 $4.39 $4.67 $4.85 $5.04 $5.34 $5.72 $6.30 $6.57 $6.75 $6.95 5/16" $3.92 $4.08 $4.39 $4.67 $4.85 $5.04 $5.34 $5.72 $6.30 $6.57 $6.75 $6.95 $7.13 3/18" $4.08 $4.39 $4.67 $4.85 $5.04 $5.34 $5.72 $6.30 $6.57 $6.75 $6.95 $7.13 $7.13 7/16" $4.39 $4.67 $4.85 $5.04 $5.34 $5.72 $6.30 $6.57 $6.75 $6.95 $7.13 $7.13 $7.13 1/2" $4.67 $4.85 $5.04 1 $5.34 $5.72 $6.30 1 $6.57 $6.75 $6.95 1 $7.13 $7.13 $7.13 $7.23 5/8" $4.85 $5.04 $5.34 $5.72 $6.30 $6.57 $6.75 $6.95 $7.13 $7.13 $7.13 $7.23 $7.43 3/4" $5.04 $5.34 $5.72 $6.30 $6.57 $6.75 $6.95 $7.13 $7.13 $7.13 $7.23 $7.43 1 $7.43 7/8" $5.34 $5,72 $6.30 $6.57 $6.75 $6.95 $7.13 $7.13 $7.13 $7.23 $7.43 $7.43 $7.62 1" $5.72 $6.30 $6.57 $6.75 $6.95 $7.13 $7.13 $7.13 $7.23 $7.43 $7.43 $7.62 $7.62 1-118" $6.30 $6.57 $6.75 $6.95 $7.13 $7.13 $7.13 $7.23 $7.43 $7.43 $7.62 $7.62 $8.19 1-1/4" $6.57 $6.75 $6.95 $7.13 $7.13 $7.13 $7.23 $7.43 $7.43 $7.62 $7.62 $8.19 $8.48 Caulking Chart pricing per Linear Foot Installed 1 Component Silicone Rubber • 1 JIM 118" 3/16" 1 /4" 5/16" 3/18" 7/16" 112" 5/8" 3/4" 7/8" 1 " 1-118" 1-1 /4" 1/8" $3.54 $3.73 $3.92 $4.01 $4.20 $4,46 $4.77 $4.96 $5.15 $5.43 $5.80 $6.37 $6.67 3/16" $3.73 $3.92 $4.01 $4.20 $4.46 $4.77 $4.96 $5.15 $5.43 $5.80 $6.37 $6.67 $6.85 1/4" $3.92 $4.01 $4.20 $4.46 $4.77 $4.96 $5.15 $5.43 $5.80 $6.37 $6.67 $6.85 $7.06 5/16" $4.01 $4,20 $4.46 $4.77 $4.96 $5.15 $5.43 $5.80 $6.37 $6.67 $6.85 $7.06 $7.23 3/18" $4.20 $4.46 $4.77 $4.96 $5.15 $5.43 $5.80 $6.37 $6.67 $6.85 $7.06 $7.23 $7.23 7/16" $4.46 $4.77 $4.96 $5.15 $5.43 $5.80 $6.37 $6.67 $6.85 $7.06 $7.23 $7.23 $7.23 1/2" $4.77 $4.96 $5.15 $5.43 $5.80 $6.37 $6.67 $6.85 $7.06 $7,23 $7.23 $7.23 $7.34 5/8" $4.96 $5.15 $5.43 $5.80 $6.37 $6,67 $6.85 $7.06 $7.23 $7.23 $7.23 $7.34 $7.52 3/4" $5.15 $5.43 $5.80 $6.37 $6.67 $6.85 $7.06 $7.23 $7.23 $7.23 $7.34 $7.52 $7,52 7/8" $5.43 $5.80 $6.37 $6.67 $6.85 $7.06 $7.23 $7.23 $7.23 $7.34 $7.52 $7.52 $7.71 1" $5.80 $6.37 $6.67 $6.85 $7.06 $7.23 $7.23 $7.23 $7.34 $7.52 $7.52 $7.71 $6.37 $6,67 $6.85 $7.06 $7,23 $7.23 $7.23 $7.34 $7.52 $7.52 $7.71 $7.71 f$7.711-1/8" 81-1/4" $6.67 $6,85 $7.06 $7.23 $7.23 $7.23 $7.34 $7.52 $7.52 $7.71 $7.71 $828 8 148 IFB #PW1925 Roofing Supplies and Services, Waterproofing, and Related Products and Services Attachment C - Bid Form Line Item Multiplier to Adjust Labor Costs Based Upon the Prevailing Wage Rate. Prevailing wage found at http://www.wdol.gov/dba.aspx#0 Journeyman Multiplier Prevailing for Prevailing Wage Wage Rates Rate Roofer Mason Sheet Metal $10.00 0.8260 0.7320 0.7050 $12.50 0.8260 0.7320 0.7050 $15.00 0.8340 0.7320 0.7050 $17.50 0.8430 0.7320 0.7050 $20.00 0.8530 0.7470 0.7230 $22.50 0.8640 0.7620 0.7410 $25.00 0.8750 0.7770 0.7590 $27.50 0.8870 0.7950 0.7770 $30.00 0.8990 0.8130 0.7950 $32.50 0.9110 0.8310 0.8130 $35.00 0.9230 0.8490 0.8310 $37.50 0.9350 0.8670 0.8510 $40.00 0.9480 0.8860 0.8710 $42.50 0.9610 0.9050 0.8910 $45.00 0.9740 0.9240 0.9110 $47.50 0.9870 0.9430 0.9310 $50.00 1.0000 0.9620 0.9540 $52.50 1.0130 0.9810 0.9770 $55.00 1.0260 1.0000 1.0000 $57.50 1.0390 1.0300 1.0300 $60.00 1.0520 1.0600 1.0600 $62.50 1.0650 1.0900 1.0900 $65.00 1.0780 1,1200 1.1200 $67.50 1.0910 1,1500 1.1500 $70.00 1.1040 1.1750 1.1780 $72.50 1.1170 1.2000 1.2060 $75.00 1.1300 1.2250 1.2340 $77.50 1.1420 1.2500 1.2620 $80.00 1.1540 1.2750 1.2900 $82.50 1.1660 1.3000 1.3180 $85.00 1,1780 1.3250 1.3430 $87.50 1.1900 1.3500 1.3680 $90.00 1.2020 1.3750 1.3930 $92.50 1.2140 1.4000 1.4180 $95.00 1.2260 1.4250 1.4430 $97.50 1.2380 1.4530 1.4710 $100.00 1.2500 1.4810 1.4990 $102.50 1.2610 1.5090 1.5270 $105.00 1.2720 1.5370 1.5550 $107.50 1.2830 1.5650 1.5830 $110.00 1.2940 1.5930 1.6130 $112.50 1.3050 1.6210 1,6430 $115.00 1.3150 1.6490 1.6730 $117.50 1.3240 1.6770 1.7030 $120.00 1.3320 1.7050 1.7330 150 O O OD cc V � U. LL �. U. s U) w O N T L = O U)N N N T L O U)N -p N T L LL O (n N . LP V >, C N C C N O C co c a ? •N c a v� ❑ LS o C6•C C� O a; o �•� c a N O a)> �.� c o: N c := o CL mmol- �E�o> mE �E—� w m � ma Q i � uNi is ( m `1 C > m ,E W�`a m oca� > 20± aiic a Cl)r A U) C — co m U Q pq ppat 0 = O CNO� aU p— CNO� aUQ d mt•�L> GC U O N F- • Ccc i— 'C O N f- C C y O 0 cn m Q O qA C wO C. O •C (t1 Co o C L IL C N— a)a ��y i- .0 L Q c) Cc'0 C L Q. N m •D P .0 � L E U) a) m "a .c I-- L C C cL7 N ¢��¢? w C ¢��¢¢ ¢��¢� 3 T ¢wco ��- .c7 acd z z z ui O O O c ii m a O a O a O d d' m e > w a c a a a Q cj W W LU ti O C7 Q Q Q N u. m cl w w tC �= d o += a � N s W Q N Z d z d QQ aa � a c =m = o m t9 •a t9 � J z 8 t U O O V om p G p Q >+ O Z, o 0- °aroo a= O N O co O O cm O O O O O O O 1� N N N N N � P- I- LO r- m N 4 6 M r O LL LL LL U) LL (n LL U) LL U) w O N N O CO C N O r •C U) 0 O .0 G d a) O 'O-' O .0 .0 T D O .� C d) a a) C a) O .0 C ) LL na-'E� IL C t- U o�-'E� (n IL C� U �n E� io 11 C_ a) {T n� E�� a, lL C Q a0- E� m o IL C ._-� a) a +, n� E� ca c lJ � ,l 0> O (0 M O O O m m 0 o O Of m M O O N O- w M CO O m L O m m 0 `m 0 O m m 0 0 �a�� a� nab �m ,aC:) od (na0 0) Q (na� 0)� Q >m4-- a Y �o= o >m40- a.>_ Y rn-= o m > mw Qm Y a)0= �� >mt mFL Y a'a=�U >mE US Y �o=� > !� ui Y �o= co n U 0. C m o o U U) 2 a C U) a °� m o_ -Z 0 2 Q a U) � a °) o U) a " c.) m -0 Q ._ m LL -0 >,•- U)_ 0E-a m m LL a >,•- Q m- ��a ._ CO LL a >, 0 Q U)_ a)I- 0 m LL a >, t o 70 �- m�=� o m LL a >, 0- U)- off oa U m E a >, N Q" N w- a)I- Oa L ro U U N j V (6 -C 0 o- N j@ (0 @ m,C NLL N j fU9 f6 a 0 m N OS N j N (0 C - U (OQ N N N (6 mo p _ OU N cc M o _ OUQ a`)r co U) ioQa CO cn mQ cO U) m o m `° Mcnten. coa LL oa m ) oa U U Q) D L) aEi 0 L 2 O L U u7 0 � 0 = 2 O O (0 � L O N N _0 w C L C O .L O a) N O w C C L C E L O a) (n L Q U) C E L C a L O a) N> U) C E L C O F- .0 O N E ..0 CL U) C E L C a n L O a) (n.00 E U) C E L C a a) Qw2iw �� Qw�U) m� Qwlncn �Q> QwU)U) o= QwU)U) QQ QwU)co Q:E w W Z Z Z Z z z O O O O ��' O O O O LU LU O O O O z z O O O O O O L) U U U O O 06 08 otl °tS w w w w z z z z M M M 0 a: 0 O O 0 0 0 0 0 0 0 0 0 0 0 0 0 N N N N N N $ % / % z z z k U. b b $ $ ] g.k /a§ �0 �0 © '®2=\� j=E§£/ »-\ ®%W- /o /o ƒ z=2-=- >-e o \z = /z = y ±§3g®/ \6`EE `\ Co g /m=BSc 7 E Q= \0\0b c // ±__=eao % z%$\ I _ c o« /§ cƒ /_ j/kk\[� «__ \\Gy)f /E ;/ ;/ \g =z=>ec%C\j >cm o_ o_ o- ® 5 3 \ o \ e § ! = o o ° _ ° _ ° o ® e = �E�'-®3 9 12 m c ; - '%°�°=> f] \J G=/\CO0 222\/=°>@2>r:2 of"2 0\\/2k\�kf�k/c� = G o% 3= E \f/7@/3 = a-*- m& \\\/Rm2\E b c 3 0 3 —0.0 a 2 <u=m3z= e==<5&<u=<=u<= 0 § § § § f ƒ ƒ ƒ 0 0 a a a z M _ _ 0 } z z z uoa & ƒ z k k k } m 2 § 0 z 0 0 w \ f \ \ \ / \ / / / 3 3 3 3 3 o 00 -: Cl) r o r� x� LL LL LL U LL r; 3 N 3 Ncoa 3 N +� a c L4aa) a ai c o Li= a�L a� ai c o a) >C) =Ca � m � a � L w O , hMaa>� Qc°� a a�o _ ooU) QuCdG oa6) ro ' c m ' c d.c0 �c m pm sa a) n a c m a a aim o) ° m a comns a CO.) a) a Co `o 0)- a L) m Emm�UF OL .00 cn � �Nc�(a QO LL aa)QO � Ma a)LLLL — U) >, Q C) m n a) A :� UM CO aj = T L)= C t t0 m c 7 .N m c C .� m C 7 + m E ul co O C a^. (Q O c a ..!, O C ..'. 0 +'. O C a ' �c CL E c~ N aaN E.5"0 a) c o F- an.� �? o c 1 CL E (D u) CL zs � Cl) ai QQ mom �m to � � a� = o QQ ca�m�2 lA � � an y o QQ n3�m�U) c� � � a� = te a QQ m�m�Q> g�,' O A w w w !E z z z z 2 0 •y LL Q ti O LL 0 L) a 0 0 0 ,!S w ►- uw ONE d p d M a Z 0,� F= E at o LL m zo.m r 's LL o' d 0'a a 0 0 co 0 0 M O M O Cl) O Cl) O Cl) O Nf� N N N N VLO (O C N 00 r M r O N cY �- U) U) in U) L U .3 N 0.. L Ln o .3 N m L Cn a) .3 i L L .3 N a) N U co ° = C0 m ~ _ � Uo 4_° m ai °) ma m — a.)LL `0 4 o ``-- CU m a 0= o �� U o a� � o= Q T c o o ooi � o= Q a c? a°i m rna °= �:F I-aU �g m °o �� I- T� m �� H U) � ° o> 0 �� f- o m T� an d 0 � 0 Q M Cc o_ � � LL � (n 0 <n � c`a � � a� 0 w � � o � m CO N o a Q f- � M d � m o o.n a U m= y o o a�i o� a U is U U a�i o.o a U m U U° ° �-0 a U m U �_ ca C C L N C a O U C� a E :EO` > 'cn a) C C m U o mm OL. ii '� U° m o CD o iL N U m o o 00 LL Cn Cn ° o a aU -0 o° 1L •� m a) U a co Q) ,� L (n Q= m a 0 C- C- LL o c o N ,� L LL O a m a w ,� .0 in a ;a) cc a> Cn ] C 0 co a> � c0 U co a> 0 C4 U (n 0Q Co Cu a U)to 0 CO m a E M 'y 0 Crp m >' E : 'w 'C Cro m >' E j '(n •c (O m >' E 7 'in LL, ° U o c m 'U (� C Q) -_ p) p m o c a 'V fn G Q) a) — m ° C a m 'U (/) 0: Co ° c _� 'V fn C N -' a L E C a) L Q .0 E C a) L L a .0 E C a) L a •C E C L '� Q � a o� CO to co a) - > o� I— a Cn L a U) a) - O U) t h- a cn -_ L CO to Cn N -vim- a O a Cn m •_ a o U) U) a) +- 4� (n C1 QQ m QQ mQ2i Co �QQ Z Z Z Z O O O O I-- IL a a. O O O O z z z z F- O O O O CU V U U 06 08 as ca W W LLJ W 9 9 9 9 2 2 2 n 2 2 m 2 Z Z Z Z m M W a: O O O O tr w w w 0 0 0 0 ri 0 co 0 co 0 ri 0 N N N N / / $ % % b $ \ 2 \ ag \\ \\ \o CL 4 tw_: oz _ j \z F /z \ 6 y a 7\� o , ,§ \0\ p �o � � z �=2\&ƒ me m: cc __ == __ m� __ [ k / cc ) [ / 0 � � � � � a) 0 � � 0 ==m=m CL o= o= \] o= \\ o� \R = 2(n16 R c S g m �ag222a0.206L > m e=) 2 2 E c 2 D o u) k/&e 0 = ® ; & 2 o o : #J2ƒ\m=23=/2\23J> o ! E — _ ° _ , E = CO / _ = f = _ e==e=&<==<=z<u2<& \ \ \ \ \ § § § § § a a a m / / } § § § / § 7 7 7 f \ \ / \ / \ \ \ \ 3 3 3 3 3 N CO to � Ch N tf) co ti C6 LL LL LL LL LL LL — O p O p O p O p •— 0-0 NNO M N N N f- N 0 a) — U C — pM O O — U o m e c o o va a� a a oa •� o ao a) '0 op a a) a a o�•� a� a Q O c- •3 O c-m c m oo - Q o O U- oU @ Q y H Cn � .O~O c a) 'o � a).c ic1 'o m -0 m LL U Q LL N m N a cC`9 V O a) a) rn f94- O a) rn N CD cn >,N-0H CO E@ -0 N Cfl >.N-0E- to a) E Cfl >,N- N c QC a) = Q °N QcCai O �L U) F- n N cn � n n a m m U Qco ' A c oU O > _- n co c Lc>ONL O n 7 Nd _I C5 >d Q O 5 79 O O a)°O O N N p �Q +c a O Q a +=O 2UU . NLLm0 LLm LLE:92Q EC_T:2U)UI—W m tp O O O O O O °' 4. O O O O O 0 rod O O O O O 0 0 N 0 � > > > m > D 6 LL C) M C9 0 H � LD LL LL LL LL O O O O O O N r+ LL LL LL LL LL LL 0 t O O O O O O LL w w w w w w m m m C m V O O Z Cyi od _ ` ,a c N Q •�:, � � C LL tA Z N O0.6, v N..d LLa!� O ,>, ci O n a New, 0 0 0 0 0 LO 0 .' o 0 0 0 0 0 N N N N N N N (o o (0 o C; 0 0 Z Z r r r r LL LL LL LL LL LL U) (n cn U) a s L y? c ai -�cu 0 p � .- N a)-0p TL U N O .O N TL C O N .o p T C- U) N Y � a N i z � °@ � C 0 0) d76 �0a a�O p o ��0 U) CO 0 (CON C o Lr)Z U W CO C O aQ7 L O W O p a (0 C C 0 O p U� �p C O �° p U �p C O m O (9 o p M .3 O 4= E E_ E _� N J O•�° O `�- -`. CUo a N .0 w a O N� E Y E a N E a .� �. Z (n N= N M �. O LL m C= LL m C U m LL m C U L N .-- %" - o co -. U) C p w O (n N C (n N C m U) N C p Q p O (n C >O > - m rp co (nC O �? m 4_- (� "O _ m 4_- N (n -0 = i-- m 4_ C� a = O N ,� O O C m •0 U p O V (6 E O (oo m y E 2 d O �, coN�. N O ` (o p. O O ` C Q. N o (B C N a O' s mom SU co ��� cc C) co m~a E ,o o� c t � og c a•� N Q N inO . .. di 00, U) M O- a O 2= .C•Ul U) N M C M 0 N M C O Ul (/) N� C o O p ,E - O o U 2 a N .� Q co Q Q R� f- Q Q Q LL J Q O. Q J J c=i 0 M a z 0 z 0 z z 0 z ag a z Oo v m ri .; d Z D C9 ro � o u Z .o og .. »- � O N O Cl) O d' O LO O (O O v O O O O O O N N N 04 N I N N a o_ z z LL LL m co >- o o o Z CO L Cc2 0 o = a m � m � >cu >N 0 0.- 0 ' a) 0 > N '> o 0 0 a ,� o a 0 m o 0 m a a y E m QJJ <C O W W S S a a 3 � 0 0 LO U') 0 0 CNN N O d Iq d' N co CO Cn Io LL LL LL LL LL LL LL U) fn U) Ui 0)fn -O ax * s, L . , N Q �• .n 'n O 'a �€ d _ 5 C= a N >, _C L O(�0+U-' T .UC f0 O(Ap 0 >, t Ofn- a) .N- oZS C�j j i O �Z i' O pZ _ N O N ,� d= 4- O m d= ,«- -0 O d= 4- O o m c O .fl p (0 O N L (0 M Co p o o N O m e t— 0 o O m c_ o d) O C m e O Jm ❑zo N,O►td0+ ac� c4c—_- Ec0) E '�> n c E Eco m n) _0�o O o6OI a- CL !n O ImA LLL um O > > .),' v. MUO M _ 1 'O M U N M trU 0 C\j c> o O � o to mA o o=o o_-0 o o o a) c`3cmL� 1 %':a-`r" jo L Ncfl m E No ao-. o t_ ca.a a Q; - � o a) 0- -O o o n U E O NHU CLL❑ o c °u) m a 0)< C o o n f`T°- mot -- tiF ❑ LL 'a •C O O �CD` ❑ uE L @ O ' -tn O U 5 Ca a ' (n N •°a O. O (0 ca. ,OcC 0 (4 t ' z V 3' € L (n (0 O O f .0 -2 N (/) N (O C f" ,C U u) y U N O C cu I— .0 N E (� N (0 C N Q N p m E —_ 7 �O �O . .� O, •� 'i Q m�_ Q 2 Q� 2 m Q O 0 _ W z W z 6i z L I W W W LU LU uj LU a a. dam:' > 0 z 0 z C9 z C9 z z a z z d{,� 00 00 00 ° oxg, Q $gig MUM- t) � i B V m ��r�QRL O O Cl) CDO O -t #0.. O O O O O O O . '"# N N N N N N N N 00 r n- O Ih (O r �' Z h 00 r O c? U. LL LL U. LL LL LL LL LL LL LL LL LL r V W O O a n N w -oo w a m m m L a c o L o o L ZY o o a o`o o �c va L m� �� Lu wu1 yLU c Ew c EW (a'. N- O o 'O 'O 'O r �-' r 0_' 'O ° o a o LL 7 L c_O L cO m_ a. a S 0 °' 0 m a� L E a� E a� co E a� m a� r a� m m m o c o c r a�ZO c_ c c c m m c(A c(n ccn oQln oQcn o 3 d r c °� E a a 0- o U C� o D U C7 a a m d 0 U 0 `m U a� - aai mr- a Om m N � aaa d oo E N E N U o U o U p EU EUc ,p Q = j N=ro d E CO T E EO O C Q-OCO . U 0 NO@O@ cn O —co CD N� m d E ?a E ccaaE aa?aa5 m m m > m a _ a a m m m m m m a m a a a a QQ ma a md� QC� Q7 QC� QO C QdCQ O O O O O O O O O O O O F- F- p p p 1- F= p p p p h- _ a O a O a O a O a O a O a O a O a O a O a O a O U _ N c 2 2 2 co 0 2 = dl� (n W to W F- ❑_ F- ❑_ I- ❑_ co W U) W F- ❑_ F- ❑ F- ❑_ O J O J Z U U J J J U U J J J d F Z Z Z F Z Z Z a a a a a aQ. `o d v� as C C � O a LL 0 s E co r N Cl) 'Y In (O r- co O O O O O O O O O O O O ti.. ti ti ti ti ti ti ti ti ti O 0:. O O O O O O O O O O O O N - N d' N d' N d' N V N N V' N d' N "It N N N N N \ / % ƒ % / - z z z z z U. b $ b b b / e / %9 m0 4 § / 2� @ ƒ0 // rz /\ oz /o oz �\\ ter= \\§0 \/ \\ // \ ��00 \e $\ �§2°° /ƒ\ )£\/}\E- }[ f2 /§ »0 \ ; co ; \ > /= S-- S -3 R o\ �_ ))\3= « o {i 2/ i 3(M a) C $ / } ] w k / 2 k / 2 / E / \ E } o= / e2±Be=4/ak- ,- " o - C,6CL - 2\I 3m 7e/ \ 2\0UE22 \= \\/' \, <c<±e==a=&$32<==<=_<& � § § § § § \ f ƒ f ƒ f ■ a a a a q o z Q z § z § z § z § / 7 7 § § 2 4 2 % % / \ \ \ \ \ \ 3 3 3 3 3 3 EXHIBIT B PutR,dhi asung Depa>rfiinent 730 Wisconsin Avenue Racinc, WI 53403 , c ,' 1l-ne uJ��l22-3-3700 c T C 0c) y fax:262-636-37G3 yy ROOFING SUPPLIES AND SERVICES, WATERPROOFING, AND RELATED PRODUCTS AND SERVICES CONTRACT 2019 This Contract made and entered into this ' i day of . 2019, by and between Racine County, Wisconsin, 730 Wisconsin Avenue, Racine, Wisconsin 53403 (hereinafter referred to as "COUNTY") and Garland/DBS, Inc., 3800 East 91st Street, Cleveland, Ohio 44.105 (hereinafter referred to as "CONTRACTOR"). WITNESSETH: For good and valuable consideration, the parties agree as follows: 1. WORD: CONTRACTOR shall provide ROOFING SUPPLIES AND SERVICES, WATERPROOFING AND RELATED PRODUCTS AND SERVICES: The undersigned parties understand and agree to comply with and be bound by the entire contents of Sealed Bid # PW1925: ROOFING SUPPLIES AND SERVICES, WATERPROOFING AND RELATED PRODUCTS AND SERVICES PROJECT MANUAL (aka, the Contractor's Bid Proposal submitted September 4, 2019) which is incorporated herein by reference. CONTRACTOR understands and agrees that the bonds and insurance required by the Project Manual are to be kept current at all times through the length of each term and for 90 Days following completion of each term, Bonds and insurance must be renewed and presented to the COUNTY at the time of each renewal term if COUNTY chooses to renew. Bonds and insurance shall be written by a firm acceptable to the COUNTY as specified in the Project Manual. 2. TERM: October 15, 2019, to October 14, 2024, with full renewal of one (1) additional five (5) year term per the Project Manual. COUNTY shall exercise renewal options by issuance and delivery to CONTRACTOR of a written notice to renew this Agreement. 3. PROJECT: ROOFING SUPPLIES AND SERVICES, WATERPROOFING AND RELATED PRODUCTS AND SERVICES in accordance with the Project Manual. 4. PRICE: Price as stated for all schedules included in the Project Manual. 5. GANCELLA"rm: This contract may be cancelled without penalty or obligation of any kind, by COUNTY by, for or on behalf of itself or its agencies, departments, officers, agents or employees immediately upon written notice to all parties that sufficient funds have not been budgeted by the County Board of Supervisors to pay the obligations under this agreement. Either party may terminate the contract on the anniversary date in any subsequent year of the contract by providing the other party with written notice ninety (90) days prior to the anniversary date. If the CONTRACTOR fails to maintain and keep in force required insurance, COUNTY shall have the right to cancel and terminate the contract without notice. Notwithstanding any of the terms and conditions contained herein, the COUNTY and CONTRACTOR reserve the right to terminate the contract at any time for any reason by providing written notice of termination to the other party no less than ninety (90) days in advance of termination. In the event of said termination, CONTRACTOR shall not reduce its activities hereunder unless agreed in advance by COUNTY. The CONTRACTOR will pay according to the contract for services tendered through the date of termination. RACINE COUNTY ®ate 2 27- t 'i Certified to be correct as to form BY: Y.I —,---- JOt A'1'HA LA GRAVE By �� RACINE COUNTY EXECUTIVE Racine Couney Corp12 ounsel BY:VV N en is n (i ; r q REVIEWED BY FINANCE DlpEC701 Racine my CI rk GARLAN BS c. y 7 /F 818n Date BY: �oyl�ct M,Sc�,� �rci EXHIBIT C CONFLICT OF INTEREST QUESTIONNAIRE FORM CIO For vendor doing business with local governmental entity This questionnaire reflects changes made to the law by H.B. 23, 84th Leg., Regular Session. OFFICE USE ONLY This questionnaire is being filed in accordance with Chapter 176, Local Government Code, by a vendor who Date Received has a business relationship as defined by Section 176.001(1-a) with a local governmental entity and the vendor meets requirements under Section 176.006(a). By law this questionnaire must be filed with the records administrator of the local governmental entity not later than the 7th business day after the date the vendor becomes aware of facts that require the statement to be filed. See Section 176.006(a-1), Local Government Code. A vendor commits an offense if the vendor knowingly violates Section 176.006, Local Government Code. An offense under this section is a misdemeanor. .1J Name of vendor who has a business relationship with local governmental entity. &f(0,.i p SI .-F-T^C- • 2 ❑ Check this box if you are filing an update to a previously filed questionnaire. (The law requires that you file an updated completed questionnaire with the appropriate filing authority not later than the 7th business day after the date on which you became aware that the originally filed questionnaire was incomplete or inaccurate.) 3 Name of local government officer about whom the information is being disclosed. /y /A Name of Officer 4 Describe each employment or other business relationship with the local government officer, or a family member of the officer, as described by Section 176.003(a)(2)(A). Also describe any family relationship with the local government officer. Complete subparts A and B for each employment or business relationship described. Attach additional pages to this Form CIQ as necessary. A. Is the local government officer or a family member of the officer receiving or likely to receive taxable income, other than investment income, from the vendor? Yes ®No B. Is the vendor receiving or likely to receive taxable income, other than investment income, from or at the direction of the local government officer or a family member of the officer AND the taxable income is not received from the local governmental entity? Yes � No -5j Describe each employment or business relationship that the vendor named in Section 1 maintains with a corporation or other business entity with respect to which the local government officer serves as an officer or director, or holds an ownership interest of one percent or more. 46• 6 ❑ Check this box if the vendor has given the I'AW'"ZU&,�- or a family member of the officer one or more gifts as described in Section 176.003(a)(2)(E�e1 c i d in Section 176.003(a-1). 7 • oo �o z� . 20 V13� Sig'ftakweo9bTvendoVolng bu ness ftith the gsvernfli �enii� . • Date ••ryWAR,. Form provided by Texas Ethics Commission 1#%W7kw; thics�s0e.tx.us Revised 1/1/2021 CONFLICT OF INTEREST QUESTIONNAIRE For vendor doing business with local governmental entity Acomplete copy of Chapter 176 of the Local Government Code maybe found at http://www.statutes.legis.state.tx.us/ Docs/LG/htm/LG.176.htm. For easy reference, below are some of the sections cited on this form. Local Government Code § 176.0010-a): "Business relationship" means a connection between two or more parties based on commercial activity of one of the parties. The term does not include a connection based on: (A) a transaction that is subject to rate or fee regulation by a federal, state, or local governmental entity or an agency of a federal, state, or local governmental entity; (B) a transaction conducted at a price and subject to terms available to the public; or (C) a purchase or lease of goods or services from a person that is chartered by a state or federal agency and that is subject to regular examination by, and reporting to, that agency. Local Government Code § 176.003(a)(2)(A) and (B): (a) A local government officer shall file a conflicts disclosure statement with respect to a vendor if: (2) the vendor: (A) has an employment or other business relationship with the local government officer or a family member of the officer that results in the officer or family member receiving taxable income, other than investment income, that exceeds $2,500 during the 12-month period preceding the date that the officer becomes aware that (i) a contract between the local governmental entity and vendor has been executed; or (ii) the local governmental entity is considering entering into a contract with the vendor; (B) has given to the local government officer or a family member of the officer one or more gifts that have an aggregate value of more than $100 in the 12-month period preceding the date the officer becomes aware that: (i) a contract between the local governmental entity and vendor has been executed; or (ii) the local governmental entity is considering entering into a contract with the vendor. Local Government Code § 176.006(a) and (a-1) (a) Avendor shall file a completed conflict of interest questionnaire if the vendor has a business relationship with a local governmental entity and: (1) has an employment or other business relationship with a local government officer of that local governmental entity, or a family member of the officer, described by Section 176.003(a)(2)(A); (2) has given a local government officer of that local governmental entity, or a family member of the officer, one or more gifts with the aggregate value specified by Section 176.003(a)(2)(B), excluding any gift described by Section 1 76.003(a-1 ); or (3) has a family relationship with a local government officer of that local governmental entity. (a-1) The completed conflict of interest questionnaire must be filed with the appropriate records administrator not later than the seventh business day after the later of: (1) the date that the vendor: (A) begins discussions or negotiations to enter into a contract with the local governmental entity; or (B) submits to the local governmental entity an application, response to a request for proposals or bids, correspondence, or another writing related to a potential contract with the local governmental entity; or (2) the date the vendor becomes aware: (A) of an employment or other business relationship with a local government officer, or a family member of the officer, described by Subsection (a); (B) that the vendor has given one or more gifts described by Subsection (a); or (C) of a family relationship with a local government officer. Form provided by Texas Ethics Commission www.ethics.state.tx.us Revised 1/1/2021