Loading...
HomeMy WebLinkAboutContract 59160-R1CITY OF FORT WORTH CONTRACT RENEW AL NOTICE Malouf Engineering International, Inc. Attn: Mark Malouf 3905 Wishing Well Lane Plano, TX 75093-7586 February 29, 2024 Re: Contract Renewal Notice Contract No. CSC No. 59160 (the "Contract") Renewal Term No. 1, April 3, 2024 to April 2, 2025 CSC No. 59160-Rl The above referenced Contract with the City of Fort Worth expires on April 2, 2024. Pursuant to the Contract, contract renewals are at the sole option of the City. This letter is to inform you that the City is exercising its right to renew the Contract for an additional one (1) year period, which will begin immediately after the Expiration Date. All other terms and conditions of the Contract remain unchanged. Please return this signed acknowledgement letter, along with your quote for charges for the new renewal term, and current insurance certificate, to the address set forth below, acknowledging receipt of the Contract Renewal Notice. To ensure that your company information is correct and up-to-date, please log onto PeopleSoft Purchasing at https://www.fortworthtexas.gov/departments/finance/purchasing. If you have any questions concerning this Contract Renewal Notice, please contact me at the telephone number listed below. Contract Renewal Sincerely, City of Fort Worth IT Solutions I Finance I Contracts 200 Texas Street Fort Worth, TX, 76102 zz IT Finance Contracts@fortworthtexas.gov Page 1 of2 [Executed effective as of the date signed by the Assistant City Manager below.] I [ACCEPTED AND AGREED:] City: ·/4,.,,--By: Mark McDaniel (Mar 9, 202417:28 EST) Name: Mark McDaniel Title: Deputy City Manager Date: Mar 9, 2024 Malouf Engineering International, Inc. By: Name: Mark Malouf Title: President Date: 02/29/2024 Digitally signed by Mark Malouf DN: cn=Mark Malouf, o=MEI, ou, email=mmalouf@maloufengineer ing.com, c=US Date: 2024.02.2912:23:11 -06'00' CITY OF FORT WORTH INTERNAL ROUTING PROCESS: Approval Recommended: By: Name: Kevin Gunn Title: Director, IT Solutions Approved as to Form and Legality: �� By: T- Name: Taylor Paris Title: Assistant City Attorney Contract Authorization: M&C:NIA Approval Date: NI A Form 1295: NIA Contract Renewal Contract Compliance Manager: By signing I acknowledge that I am the person responsible for the monitoring and administration of this contract, including ensuring all performance and reporting requirements. L.,:......,.� • By: Lawrence Crockett (Mar 7, 202413:33 CST) Name: Lawrence Crockett Title: Sr. IT Solutions Manager City Secretary: By: Name: Jannette Goodall Title: City Secretary Page 2 of2 3905 WISHING WELL LN PLANO, TEXAS 75093-7471 TEL. 972-783-2578 February 29, 2024 Ms. Betty Santos Via e-mail CITY OF FORT WORTH Fort Worth, TX Subject: Scope of Work Proposal CITY OF FORT WORTH, TX Thank you for the opportunity to work to present MEI Scope of Work statement and fee proposal. I- SCOPE OF WORK COMPREHENSIVE TOWER STRUCTURAL ANALYSIS: A. Perform a Structural Analysis of subject tower in conformance with the ANSI/TIA 222--H Standard Requirements for the proposed appurtenances loading. The following is considered to be supplied to MEI: Tower Location & Structural data (configuration & member sizes) Foundation data (geometric size & geotechnical information) Current & Reserve appurtenances data (antennas model, quantity, elevation & corresponding mounts & lines) Proposed change condition data (proposed appurtenances) Recent photos showing tower & appurtenances from 2 directions. B. Prepare an Engineering Report which including analysis Results and general Recommendations, and which will be sealed by a Texas Professional Engineer. MEI will furnish an electronic copy of the report. TOWER MODIFICATION DESIGN: A. Design Structural Modifications and perform additional analyses as required to optimize the proposed modifications required to be in conformance with the ANSI/TIA 222-H Standard Requirements for the proposed appurtenances loading, as applicable. A prior MEI structural analysis is a pre-requisite for this scope. The following is considered to be supplied to MEI: Tower Location & Structural data (configuration & member sizes) Foundation data (geometric size & geotechnical information) Site/Compound Plan Current & Reserve appurtenances data (antennas model, quantity, elevation & corresponding mounts & lines) Proposed change condition data (proposed appurtenances) Recent photos showing tower & appurtenances from 2 directions B. Prepare modification working drawings with relevant installation instructions and fabrication details and Technical Specification Notes. These drawings will be sealed by a Texas Professional Engineer. MEI will Furnish electronic copy of the sealed drawings. BID REVIEW TECHNICAL SUPPORT: A. Perform a Structural Review of vendor submitted technical engineering documents of subject tower for conformance with the ANSI/TIA 222-H Standard Requirements and Procurement Specifications for the specified appurtenances loading. Provide technical support in the bids review as per client request . B. Prepare a Letter of Findings and Recommendations, sealed by a Texas Professional Engineer. MEI will furnish an electronic copy of the letter. MEI SCOPE OF WORK PROPOSAL - Continued Page 2 02/29/24 3308 PRESTON ROAD, SUITE 350-159 PLANO, TEXAS 75093-7471 TEL. 972-783-2578 TOWER FIELD MAPPING: A. Perform a Tower Structural Mapping to gather above ground information to be used in the Structural Analysis of subject tower. Data collected shall include tower dimensions and configuration, member sizes, bolt quantities & sizes, guy wire assembly & anchors layout if applicable, dimensions of above ground portions of foundations and inventory of existing antennas, mounts, transmission lines or other equipment installed on tower, and general visual observed condition of tower and foundation. Ultra-sonic measurement equipment will be available to be used for measuring pipe wall thickness where applicable. The following is considered to be supplied to MEI: Tower Location & GPS Coordinate & FCC ASR number Access contact information &/or Gate Combo number. B. Prepare a report of field obtained notes and data. When mapping is performed in conjunction with structural analysis, an elevation drawing that includes the mapping findings will be included as part of the Structural Analysis Report. TOWER MAINTENANCE INSPECTION: A. Perform a tower field inspection in conformance with the ANSI/TIA-222-H Standard Section 14.0 and Annex J Section J.1 to determine the overall condition of the existing tower. The following is considered to be supplied to MEI: Tower Location & GPS Coordinate & FCC ASR number Access contact information &/or Gate Combo number Tower Structural data (configuration & member sizes) B. Prepare a summary report and provide repair and maintenance recommendations for the subject site(s). MEI will furnish an electronic pdf copy of the report. PAYMENT SCHEDULE: MALOUF ENGINEERING INTERNATIONAL, INC. agrees to furnish the previously outlined Scope of Services, with payment due NET30 days from invoice date, for the fixed sums as follows: TOWER STRUCTURAL ANALYSIS: Structural Analysis : $ 2,200.00 / tower Re-Analysis w/in 9 months : $ 1,700.00 / tower TOWER MODIFICATION DESIGN: Estimated fee of $ 3,000.00 to $ 6,500.00 - Varies based on modification extent and type of tower. TOWER FIELD MAPPING & MAINTENANCE INSPECTION Estimated fee of $ 3,500.00 to $ 4,500.00 - Varies based on type of tower and time required. Please note that the above quoted fees are valid for a period of 1-year Effective April 01, 2024. Special Condition Notes No Structural Modification Design and Drawings to the towers is included in the Analysis scope of Work. Only general recommendations regarding modifications are supplied. Modification design and drawings will be qualified as to severity after completion of analysis. No design of the transmission lines and mount support is included in the above scope UNO. All installation induced loads, procedures and methods to be the responsibility of others. Structure has a safe climbing system as per OSHA requirements & is accessible by competent climber. For towers on rooftop sites, the scope of work includes evaluation of the tower structure only and does not include the supporting frame and roof structure unless noted otherwise by the specific scope of work. In addition to the listed scope of work items, MEI can provide all scope items associated with telecommunication structures. Fees are based on standard schedule of fees with hourly rate of: $ 120/hr. for a Senior CAD Designer, $ 225/hr. for a Senior Project Engineer and $ 300/hr. for Principal Engineer. MEI SCOPE OF WORK PROPOSAL - Continued Page 3 02/29/24 3308 PRESTON ROAD, SUITE 350-159 PLANO, TEXAS 75093-7471 TEL. 972-783-2578 Thank you for the opportunity to provide you with this proposal. We look forward to discussing it and working with your company. If you have any question or need further clarification, please contact me. With Regards, MALOUF ENGINEERING INTL., INC. _____________________________ Mark Malouf, President 972-783-2578 ext. 106 mmalouf@maloufengineering.com