Loading...
HomeMy WebLinkAboutContract 61721Date Received:7/19/2024 Permit No.: SWFNU-24-0052 Time Received: 4:02 p.m. City Secretary No.: 61721 STORMWATER FACILITY MAINTENANCE AGREEMENT THIS AGREEMENT, made and entered into this 19th day of July 2024, by and between Fort Worth Housing Finance Corporation "(Fee Owner"), Palladium E Lancaster Avenue, Ltd., a Texas limited partnership (hereinafter, the "Ground Lessee") and the City of Fort Worth, hereinafter referred to as "City". WITNESSETH WHEREAS, the Fee Owner is the owner of certain real property described as a tract of land situated in the P.H. Ahler Survey, Abstract NO. 33, Tarrant County, Texas according to the deed recorded in Document No. D209329284, Deed Records, Tarrant County, Texas, hereinafter called the "Property". WHEREAS, Fee Owner has executed a Ground Lease with Ground Lessee with respect to the Site Plan/Subdivision Plan known as Palladium E. Lancaster, hereinafter called the "Plan", which is expressly made a part hereof, as approved or to be approved by the City and the Ground Lessee, provides for the management of storm water within the confines of the Property; and; WHEREAS, the City, the Fee Owner and Ground Lessee, and their respective successors and assigns, agree that the health, safety and welfare of the residents of the City of Fort Worth, Texas require that on -site Stormwater Management Facilities be constructed and maintained on a portion of the Property; and WHEREAS, the City requires that on -site Stormwater Management Facilities ("Facility") as shown on the Plan be constructed and adequately maintained by the Ground Lessee, its successors and assigns, the location and dimensions of which is shown and more particularly described by metes and bounds in the attached Exhibit "A" ("Facility Property"); and OFFICIAL RECORD CITY SECRETARY FT. WORTH, TX STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 03/01/2022 BN 4881-4504-3903.v1 NOW, THEREFORE, in consideration of the foregoing premises, the mutual covenants contained herein, and the following terms and conditions, the parties hereto agree as follows: 1. The Ground Lessee, its successors and assigns, shall adequately construct and maintain the on -site Stormwater Management Facility ("Facility") at no expense to the City of Fort Worth in accordance with the design specifications for the Facility, attached as Exhibit `B", and the current standards then in force and effect in the City of Fort Worth and with the Operations and Maintenance Plan attached to this Agreement as Exhibit "C". The Stormwater Facility includes all pipes, channels or other conveyances built to convey Stormwater to the facility, as well as all structures, improvements, and vegetation provided to control the quantity and quality of the Stormwater. Adequate maintenance is herein defined as good working condition so that these facilities are performing their design functions. The Stormwater Structural Control Maintenance Checklists, attached to this Agreement as Exhibit "D", are to be used to establish what good working condition is acceptable to the City. 2. The Ground Lessee, its successors and assigns, shall inspect the Facility and submit an inspection report to the City annually. The purpose of the inspection is to assure safe and proper functioning of the Facility. The inspection shall cover the entire Facility, berms, outlet structure, pond areas, access roads, etc. Components of the Facility, which need maintenance or replacement to perform their design function, shall be noted in the inspection report along with the corrective actions to be taken. 3. The Ground Lessee, its successors and assigns, hereby grant permission to the City, its authorized agents and employees, to enter upon the Property and to inspect the Facility Property whenever the City deems necessary. The purpose of inspection is to follow-up on reported deficiencies and/or to respond to citizen complaints. The City shall provide the Ground Lessee, its successors and assigns, copies of the inspection findings and a directive to commence with the repairs if necessary. STORMWATER FACILITY MAINTENANCE AGREEMENT 2 Rev. 03/01/2022 BN 4881-4504-3903.v1 4. In the event the Fee Owner, or Ground Lessee, its successors and assigns, fails to maintain the Facility in good working condition as specified herein, the City, its authorized agents and employees, may enter upon the Facility Property and take whatever steps necessary to correct deficiencies identified in the inspection report and to charge the costs of such repairs to the Landowner, its successors and assigns. It is expressly understood and agreed that the City is under no obligation to routinely maintain or repair said Facility, and in no event shall this Agreement be construed to impose any such obligation on the City, such obligation is Landowner's. 5. The Ground Lessee, its successors and assigns, will perform the work necessary to keep the Facility in good working order as appropriate. In the event the City pursuant to this Agreement, performs work of any nature, or expends any funds in performance of said work for labor, use of equipment, supplies, materials, and the like, the Ground Lessee, its successors and assigns, shall reimburse the City upon demand, within thirty (30) days of receipt thereof for all actual costs incurred by the City hereunder. In the event that Ground Lessee or its successors or assigns fail to pay the City for the costs incurred under this section, the City shall impress a lien for the costs of such work upon other lots owned by the Ground Lessee. Such lien shall be perfected by filing in the office of the County Clerk of Tarrant County, Texas an affidavit identifying the property to be charged with such lien, stating the amount thereof, and making reference to this Agreement. 6. This Agreement imposes no liability of any kind whatsoever on the City. THE FEE OWNER AND GROUND LESSEE AGREE TO HOLD THE CITY HARMLESS FROM ANY LIABILITY IN THE EVENT THE FACILITY FAILS TO OPERATE PROPERLY. FEE OWNER AND GROUND LESSEE COVENANT AND AGREE AND DO HEREBY INDEMNIFY, HOLD HARMLESS AND DEFEND THE CITY OF FORT WORTH, ITS AGENTS, SERVANTS AND EMPLOYEES FROM AND AGAINST ALL COSTS, EXPENSES, LOSSES, DAMAGES, CLAIMS OR CAUSES OF ACTION WHATSOEVER ARISING, OR WHICH MIGHT ARISE, STORMWATER FACILITY MAINTENANCE AGREEMENT 3 Rev. 03/01/2022 BN 4881-4504-3903.v1 FROM THE FAILURE OF GROUND LESSEE OR ANY FUTURE OWNERS OF THE ABOVE FACILITY PROPERTY TO MAINTAIN THE FACILITY, INCLUDING, BUT NOT LIMITED TO THE BED AND BANKS OF THE DETENTION POND; ANY DAMAGES CAUSED TO PERSON OR PROPERTY DUE TO (1) FLOODING OF THE POND AND ITS BANKS, (2) SLOPE FAILURE OF THE BANKS OF THE POND, (3) FAILURE OF THE POND OR ITS BANKS, OR (4) FAILURE OF FEE OWNER OR GROUND LESSEE TO PERFORM ANY OTHER DUTIES OR OBLIGATIONS HEREUNDER. 7. Fee Owner and Ground Lessee covenant and agree that no habitable building shall be erected within the boundaries of the Facility Property in which the Facility is located as outlined on Exhibit "A" but this paragraph shall not preclude construction of other improvements within the boundaries of the Facility Property in which the Facility is located, which do not impede drainage. Fee Owner and Ground Lessee covenant and agree that no habitable building shall be erected on the above Property abutting such boundaries of the Facility Property in which the Facility is located, which shall have a finished floor at an elevation less than two feet above the maximum depth of water in the detention pond which would occur during a 100-year frequency flood. 8. This Agreement shall be recorded among the land records of Tarrant County, Texas, shall constitute a covenant running with the land, and shall be binding on the Fee Owner, Ground Lessee, their respective administrators, executors, assigns, heirs and any other successors in interests, including any property owner's association. Executed this 19th day of July 2024 STORMWATER FACILITY MAINTENANCE AGREEMENT 4 Rev. 03/01/2022 BN 4881-4504-3903.v1 CITY OF FORT WORTH GROUND LESSEE: Dana $wghio# PALLADIUM E LANCASTER Dana Burghdoff (JuI1V202412-.2f CDT) AVENUE, LTD. Dana Burghdoff Assistant City Manager By: PFW E Lancaster GP, LLC City of Fort Worth a Texas limited liability company Its general partner Date: Jul 19, 2024 By: Fort Worth Housing Finance Approved as to Form and Legality: Corporation a Texas Public nonprofit housing finance ✓may corporation, its Managing Member Matthew Murray Sr. Assistant City Attorney City Attorney's Office By' Jul 17 2024 g4g4a�°n� Printed Name:'4141V (AN I V Date: V A �1a��Il��R? %°0A' 10 ,,,o Title: (j o fgfI S iYf 4aYA1gip ATTEST: ° d N408r 0onX�E454QA' FEE OWNER: Jannette S. Goodall Fort Worth Housing Finance Corporation City Secretary a Texas Public nonprofit housing finance corporation Date: Jul 19, 2024 / Contract Compliance Manager: By:1 4Amy Co olly Its: Acting ssistant General Manager By signing, I acknowledge that I am the person responsible for the monitoring and Date: Vie` w# administration of this contract, including ensuring all performance and reporting requirements. -U,In Rebecca Owen (Jul 17, 202414:05 CDT) Rebecca Owen Planning Manager Date: Jul 17, 2024 OFFICIAL RECORD CITY SECRETARY FT. WORTH, TX STORMWATER FACILITY MAINTENANCE AGREEMENT 5 Rev. 03/01/2022 BN 4881-4504-3903.v1 STATE OF TEXAS § COUNTY OF TARRANT § This instrument was acknowledged before me on J u ly 19th, 2024 by Dana Burghdoff, Assistant City Manager of the City of Fort Worth, on behalf of the City of Fort Worth. YpU BROOKE BONNELL _ Notary Public , * * STATE OF TEXAS 9�OF Notary I.D. 134009525 My Comm. Exp. Oct. 11, 2026 ' FEE OWNER: STATE OF COUNTY OF-7;Pee4,w Brooke Bonnell (Ju119, 202413:26 CDT) Notary Public, State of Texas 0 Z BEFORE ME, the undersigned authority, a Notary Public in and for the State of /t%#-i , on this day personally appeared Amv Connollv, Acting Assistant General Manager, known to me to be the person whose name is subscribed to the foregoing instrument, and acknowledged to me that he/she executed the same for the purposes and consideration therein expressed, as the act and deed of Fort Worth Housing Finance Corporation, a Texas nonprofit housing finance corporation, and in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE this /day of �u�/ , 20,Z� . Z-4�� Notary Public, 9tate of CELESTE MACKLIN Notary ID #132996882 s� +� My Commission Expires 'torte March 24, 2025 STORMWATER FACILITY MAINTENANCE AGREEMENT 6 Rev. 03/01/2022 BN 4881-4504-3903.v1 GROUND LESSEE: STATE OF %��,s COUNTY OF BEFORE ME, the undersigned authority, a Notary Public in and for the State of on this day personally appeared - A n,b I I t/ (name), A7,h{/�ij� 5il( imAl MQY1aJ,Pi✓ (title), known to me to be the person whose name is subscribed to the foregoing instrument, and acknowledged to me that he/she executed the same for the purposes and consideration therein expressed, as the act and deed of Palladium E Lancaster Avenue, Ltd., a Texas limited partnership, and in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE this Lod ay of '/ , 20,9,0/. Notary Public, tdte of 0*-, CELESTE MACKLIN Notary Ip 2132996882 My Commission Expires March 24, 2025 STORMWATER FACILITY MAINTENANCE AGREEMENT 7 Rev. 03/01/2022 BN 4881-4504-3903.v 1 EXHIBIT "A" INSERT LEGAL DESCRIPTION STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 03/01/2022 BN co 0 z Q ry cn 2 a rn 0 v i!I PELOTON . I I LAND SOLUTIONS 0 0- MEADOWBROOK DR ' k1l PROJECT LOCATION NORMA ST u E LANCASTER AVE HAMPSHIRE BLVD PAL23001 - PALLADIUM E. LANCASTER LOCATION MAP FORT WORTH -TEXAS SEPTEMBER 2023 0 w z ry w a 2_S­\PA_23002_PA d., ­111 ­11 111512023 3:55 34 Ps N Q E& 1E =E. �EE­ U.h ZED . 35sQ`% =Wcox. ­MT`MN`ID ro.a omnxswx MMA T�"R E.- 11E. 4M EFL- T1- ED S too 150 TEIVE. E.L, MIMD 17" PU. ir PP, GRAPHIC !ZTASCALE IN FEET VICINITY MAP AT, N Th`O�I M4.T1ZyM7T.ST I'M =E`.3M =D 2�­E 0 1" C. A 0 PT 'T .8E TP T. N.T S M"ZI wP D Egg�g_ 7,?W,��.oae D z U E80M�MWRMMVWA�Z7 UT.­E4E1M=T1 TT W8 D T� E MT1 _PU_ I.E TME WPN WNW =h' MAT.1y IPIM VE T =­E7ET.NA.VYN­ . hhA. ­�JTV FEhPE -, F.ND I TMI I— 1— 01 V. 1. . . . . . . . 2� T. E �F .. T f Norma Street 4 21 ' 53"E Norma Street CR TOT 0 sw P, T S 0 NO-B'D7N y z 2. 11 f 1,, - . . - - ---2E - - -- - - - - - - - - - - - I _±t_ W_ . . L - - - h- " I '. - - - - - - - - - - - - - - - - - - - 4 ----------------- T JUE / --------------- ­T I - - - - - - - - - - I I lal-, P - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ------------------------------------- I- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C TT.6 P, 11 II IT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 T 4 T. R T.C.T CH'i, Is 1 -7-4. C ­T ----- - ------------ 7 - ----------- - ------------ -------------------- 589' 37' 39 'T Do ZI 0 0 0 LOT I BLOC' 1 5, 7 946 1,V. Ij TV T V 4- O.rWh ­-T 1­1, T. D-3-84 4 E eery I- - D209329284 D—T Cz sa (point Of (Beginning OLE----- 471.72' 589'21'34'W E. Lancaster Street OWNER \ DEVELOPER EEXENT� NX-Th UM .MR 2TR :rIvX i0x.Egl WX5 SDR EYCR -E ?�DIMUTT­ P=EHE ­�­ � M M ZDMUM2�EIMU U. I Ptd P­t.9h L.d 073,,c West ... d D.hn,ny V QS7Y�VT W­== 800hHill-I,— 'T" 25o X `­ Wo817.rth, 77 T� 761 PH 562 3350 rssEo,xEcumwxowrovLrov=M MMME1 ZY T T"=T 2=4%ZLW�� PORT WORTH IWM.Mffz_ EE- PLAN COMMISSION MQE OU CITY ION C I EM TY 0 FORT WORTH, TEXAS N 1.- 01 Trov.vs xn TP es.nTv ­ —E XFP%­.k=-­ L PIA App I D,t, By 3y 1L. I.LED --ENT ­1 D PELOTO ---------- Final Plat N iilll LOT 1, BLOCK 1 LAN. —LILTI... --y Palladium Lancaster Addition _N10 HTLO­ P,­APYSO1,� 21., Final Plat LOT 1, BLOCK I Palladium Lancaster Addition 7­6 AC- St- 1, the P.H AN, S,V, M--t Number 33 City of F­ W.,th, ­,­ County, Texas. J.b# � PAL23002 RevislOnR Brawn By. TBR Checked 8y: � TAB ()EH15-2023 DESCRIPTION OF A SWFMA EASEMENT BEING a tract of land situated in the P.H. Ahier Survey, Abstract Number 33, City of Fort Worth, Tarrant County, Texas, being a portion of Lot B, Fidelity Trust Addition, an addition to the City of Fort Worth, Texas, by plat recorded in Volume 388-H, Page 253, County Records, Tarrant County, Texas and being more particularly described by metes and bounds as follows: BEGINNING at a 3/4 inch iron rod, found at the northwest comer of said Lot B, the northeast corner of Lot A, said Fidelity Trust Addition, and in the south line of Lot 6, Leroy Black Addition, an addition to said City of Fort Worth, plat recorded in Volume 388-Q, Page 67, said County Records, from which a 1 /2 inch iron rod, found at the northwest corner of said Lot A and an "ell" corner in the south line of said Lot 6, bears S 89°21'43"W, 200.66 feet; THENCE N 8902 F43 "E, 58.62 feet, to the southeast corner of said Lot 6; THENCE S 00038'07"E, 0.99 feet, to the common southwest corner of Lot 8 and Lot 7, Norma Court Addition, an addition to said City of Fort Worth, plat recorded in Volume 388-193, Page 93; THENCE S 8903739"E, 3.40 feet, with the south line of said Lot 7, to the most easterly northeast corner of said Lot B and the northwest corner of that tract of land described by deed to K4 Lancaster Apartments, LLC, recorded in Instrument Number D219238091, said County Records; THENCE S 01 006'52"E, 3.95 feet, with the east line of said Lot B and the west line of said K4 Lancaster Apartments tract; THENCE S 89021'43"W, 62.05 feet, to the west line of said Lot B and the east line of aforementioned Lot A; THENCE N 00038'17"W, 5.00 feet, to the Point of Beginning and containing 307 square feet or 0.007 acres of land more or less. "Integral parts of this document" 1. Description 2. Exhibit Peloton ,lob No. PAL23002 1*TW October 26, 2023 G:1JCB\PAL23002_Palladium_)_I,ancasterl2_SrvyTsmts\LegalslPAL23002_EA5.DCCX Page 1 of 2 Q 4 210 40 GRAPHIC SCALE IN FEET "kntegrol Parts of this Document" 1- Description 2. Exhibit Oillit Of WA, WA 589-21'43"W— . 200.66, . LSE — . — fo L1 S00°38'D7"E 0.99' L2 S89037'39"E 3.40' Lot 6, Leroy Black Addition Vol. 388-0, Pg. 67 C.R.T.C.T- NOT 38 17 W 5.00' Lot A, Fidelity Trust Addition Vol. 388-H, Pg, 253 C_R-T.C.T. TSPELS - LS FIRM REG. NO. 10177700 N89021'43"E 307 Sq. Ft. S89021'43"W Basis of bearing is the Texas Coordinate System North Centro[ Zone 4202, NAD 83 IRF • IRON ROD FOUND i L � v I+ zl C / � � o / 25' �rarnoge Esmt. Val. 388.193, Pg.93 C',R,T.C.T. 5' UE / vo1.388-4•Pg.67 � C,R.T.C,T. — /.`, Pg93 --------z Lot 7 not �g ft� �T Norma Court Addition / Vol. 388-193, Pg. 93 / L C.R.T.C-T. 58.62' L2 L1� — — - - - '-- —- — -. —•—' — 62.05' y S01°06'52,.E 3.95' Lot B, Fidelity Trust Addition Vol. 388-H, Pg. 253 C.R.T.C.T. EXHIBIT OF A SWFMA Easement Situated in the P.H. Ahler Survey, Abstract Number 33. City of Fort Worth. Tarrant County. Texas. �or�me,�1s. Lt'C Copyright(C) 2023 Peloton Land Solutions, Inc., a Westwood Company P X m F M 04 g [V ci DESCRIPTION OF A SWFMA EASEMENT BEING a tract of land situated in the P.H. Ahler Survey, Abstract Number 33, City of Fort Worth, Tarrant County, Texas, being a portion of Lot A, Fidelity Trust Addition, an addition to the City of Fort Worth, Texas, by plat recorded in Volume 388-H, Page 253, County Records, Tarrant County, Texas, and being more particularly described by metes and bounds as follows: BEGINNING at a 3/4 inch iron rod, found at the northeast corner of said Lot A, the northwest corner of Lot B, said Fidelity Trust Addition, and in the south line of Lot 6, Leroy Black Addition, an addition to said City of Fort Worth, plat recorded in Volume 388-Q, Page 67, said County Records; THENCE S 00038' 17"E, 5.00 feet, with the east line of said Lot A and the west line of said Lot B; THENCE S 89021'43"W, 42.26 feet, departing said common line; THENCE N 0003 8' 17" W, 5.00 feet, to the north line of said Lot A and said south line of said Lot 6, from which a 1/2 inch iron rod, found at the northwest corner of said Lot A and an "ell" corner in said south line, bears S 89°21'43"W, 158.40 feet; THENCE N 8902F43"E, 42.26 feet, to the Point of Beginning and containing 211 square feet or 0.005 acres of land more or less. "Integral Parts of this Document" 1. Description 2. Exhibit Pe[oton lob No. PAL23002 FTW October 26, 2023 G:1JOB\PA1,23002_PALLADIUM_E_LANCASTERI2 SRVY'IESMTSILEGAt,SIPAL2]001_EA4,DOCX Page ! of 2 m Bosis of bearing is the Texas Coordinate N System North Central Zone 4202, NAD 83- a IRON ROD FOUND LAIRF � �+7•� C Ln 40 rn � GRAPHIC SCALE IN FEET 0 "Integral Parts of this Document" 0 L Description 2- Exhibit Q\A-��N4. P � Lot 5,Leroy Black Addltlon Vol. 388-0, Pg. 67 C.R,T,C.T. Toint of 5e�inning N89021'43"E .— sS921L43'W 158.40' 42.26' IRF —------- zI�F— — R 21 1 Sq. F t. SOC° 38' 17 "E NCB 38 S89 21 3 h ! 5.00, 42.26' I ■ ! Lot A, Fidelity ! Lot S. Fldellty Trust Additlon Vol. 388-H, Pg. 253 Trust Addition C.R.T.C.T. 6= Vol. 388-H, Pg. 253 C.R.T.C.T. ! b N W ! � ! +/-p45' to E Lancaster 'Streetf EXHIBIT OF A SWFIVIA Easement _ Situated i n the P.H. Ah I er Survey, Abstract Number 33. P E LOTO N I I LAND s o u T I o N s City of Fort Worth. Tarrant County. Texas. a Wesswe°d company 9W WORTH. TEXAS PARKWAY, SUITE 250 JOB # PAL23002 (DRAWN BY: TSR CHECKED BY: TAB I DATE: 09-25-20231PAGE # 2 of 2 FART WORTH, TE%AS 76177 PR-p BIT-5623350 _ j 1=\.foe\PAt23002-Polladcum-E-Loncoster \2-Sr v>\Esmis\PAL 23002-EA4-�dgn a wt b126/2023 3:4500 PIA EXHIBIT "B" DESIGN PLAN AND SPECIFICATIONS STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 03/01/2022 BN DRAINAGE AREA CALCULATIONS Area Acres Runoff CA ' 15 15 1100 Q100 No. Coeff. (min.) (in./hr.) (c.f.s.) (in./hr.) (c.f.s.) PAL-1 E 11.14 0.54 5.96 27.0 3.60 21.49 6.09 36.32 RESIDENTIAL Area No. A-7 5 Cl UNIMPROVED C2 COMPOSITE C VALUE EX DA-1 7.95 0.63 3.19 0.30 0.54 PAL23001 - PALLADIUM E. LANCASTER 01 200' LAND SOLUTIONS Ii!II PELOTO EXISTING DRAINAGE AREA MAP II I FORT WORTH -TEXAS ��+V SEPTEMBER 2023 a 649r _ J 646 III I mac, OW 09 l I l i IfTll �t - .Yq s A i C2 C3 ttg 1I �l N I `(.0 - - �I Issue\ �I •S 101.1 1 ` 1 E1 CO - �� D O cc D1 J 61 D2 T D3 B4 66 1 62 - B3 B5 11111 li=il P E LOTO N LAND SOLUTIONS c IN a�6 t I I IQB8E. LANCASTER XVE. 1 BASIN DA-B1 DA-B2 DA-63 DA-64 DA-65 DA-66 DA-67 DA-68 DA-B9 DA-B10 DA-B11 DA-Cl DA-C2 DA-C3 DA-C4 DA-D1 DA-D2 DA-D3 DA-D4 DA-D5 DA-El DA-F1 DA-G1 OVERALL SITE PERVIOUS IMPERVIOUS TOTAL AREA G1 ON -SITE ZO N E "A-7.5" TOTAL PAL23001 - PALLADIUM E. LANCASTER PROPOSED DRAINAGE AREA MAP FORT WORTH -TEXAS SEPTEMBER 2023 AREA COEFF. TIME OF INTENSITY RUNOFF ac. CONC. in/hr cfs 0.03 0.74 10 9.14 0.20 0.03 0.74 10 9.14 0.20 0.08 0.74 10 9.14 0.54 0.04 0.74 10 9.14 0.27 0.04 0.74 10 9.14 0.27 0.05 0.74 10 9.14 0.34 0.06 0.74 10 9.14 0.41 0.16 0.74 10 9.14 1.08 0.36 0.74 10 9.14 2.43 0.43 0.74 10 9.14 2.91 0.30 0.74 10 9.14 2.03 2.95 0.68 10 9.14 18.33 0.34 0.74 10 9.14 2.30 0.41 0.74 10 9.14 2.77 0.21 0.74 10 9.14 1.42 0.02 0.74 10 9.14 0.14 0.03 0.74 10 9.14 0.20 0.08 0.74 10 9.14 0.54 0.40 0.74 10 9.14 2.71 0.39 0.74 10 9.14 2.64 0.62 0.74 10 9.14 4.19 0.54 0.74 10 9.14 3.65 2.45 0.69 10 9.14 15.45 AREA COEFF. AREA Cl AREA COEFF. ac. ac. 2.15 0.30 ON -SITE 1.23 0.74 5.79 0.90 ZONE "A-7.5" 1.72 0.63 7.95 0.74 I TOTAL 2.95 0.68 AREA COEFF. ac. 1.37 0.74 1.08 0.63 2.45 0.69 0' 200' C7 a TABLE 2.3- PROPOSED DETENTION POND RESULTS z O r O LL U U z O POND BASIN DESCRIPTION OUTFALL STRUCTURE DESCRIPTION Ln = w D w V) z � Q = cn U LU Y a z O cr_ " w a 25' wide rectangular weir at elev = 633.5 2-YR 33.4 Excavated On -Site Basin for storm 4'x4' riser box with top eIev = 631.5 P Palladium 1 5-YR 46.3 sewer mitigation (Dry bottomed) (See pond sheet in Appendix C for riser box details) 100-YR 81.6 i! P E LOTO N i 11111 LAND SOLUTIONS 0 0 0- PAL23001 - PALLADIUM E. LANCASTER DETENTION POND RESULTS FORT WORTH -TEXAS SEPTEMBER 2023 A 27.3 50.9 0.1 0.4 1.0 LMAX, 631.1 633.4 C13 a III ANCHOR DIAMOND PRO 5' UTILITY ESMT.{— STONE RETAINING WALL 10' UTILITY ESMT. (TYP.) 5' UTILITY ESMT. f w ------- ------ - —-------I�-- I U) LQ j �— —� EX SS — — - ANCHOR DIAMOND PRO _ STONE RETAINING WALL — �� -7 ---------- --- (TYP.) �� ANCHOR DIAMOND PRO PROPOSED I = I ONE RETAINING WALL (TYP.) DETENTION POND MIN. ELEV = 628.00 I r �• h 15' SANITARY SEWER ESMT. 20.22' 1 PROP. SWFMA ESMT. �If-40.67'-- I �25' EMERGENCY 12' ✓� SPILLWAY i TT7T66.H I I SECONDARY OUTLET I7_I 1 1 1 I ~ (� f h STRUCTURE -- L - U) NOTE: NO SAVED OR PROPOSED TREES s —Lu — ARE WITHIN THE SWFMA BOUNDARY N I PRIMARY OUTLET a u .STRUCTURE r z ANCHOR DIAMOND PRO STONE RETAINING WALL I 6' CONC. FLUME w N (TYP.) j rn m� i I I �� T 11111 ION PE LOTO N LAND SOLUTIONS PAL23001 - PALLADIUM E. LANCASTER SITE PLAN FORT WORTH -TEXAS SEPTEMBER 2023 NOTE: NO SAVED OR PROPOSED TREES ARE WITHIN THE SWFMA BOUNDARY C5 w 19 0 J a a III NOTE: NO SAVED OR PROPOSED TREES ARE WITHIN THE I SWFMA BOU N DARY TW=637.10 TW=636.00 / ITWI 635.00 — / — BW=637.10 S BW=631.00 gW=635.00 Lo N ES: B I � Aco I 2 C.r,E S MP 15°o MAX EXSS / — — TW=630.50 �� I PRIMARY OUTLET STRUCTURE — — — — TW=637.00 1 BW=630.50 SD-H STA 0+34.22 BW=629.50 \ M I END 36" HDPE TW=630.011 0 I INSTALL: BW=630.00 TW= 32 63 I 1 -4'X4'RECT. RISER BOX BW=629.00 W/ CATCH BASIN INLET FRAME ­/ (SEE DETAIL) / �o � /Z.- TOP OF BOX=631.50 / I � PRIMARY OPENING FL=628.00 I PROP. SWFA IA ESMT. I � � � RISER BOX FL=624.00 97 REF DETAIL SHEET � I 1` �6' 3J I J�ASD-H 36" RCP 1—T I I / I = 'J EMERGENCY SPILLWAY — FL=633.40 SECONDARY OUTLET STRUCTURE \ l RIM=635.00 —y _ _ \ 4639:6A I ---- =635.00 6g9. BW 33.00-- �\ T N V N O PAL23001 - PALLADIUM E. LANCASTER of 40' PELOTON DETENTION POND PLAN Cg E _ d I I LAND SOLUTIONS FORT WORTH -TEXAS 0 o SEPTEMBER 2023 d 30' 40' TW=631.8 EXISTING GRADE 2.0% 2.5% BW=630.5 GRASS SIDE SLOPE :: PEAK WSEL v 100 YR = 633.40 A -A CROSS-SECTION SCALE: N.T.S. 1.0% MIN TW=635.00 FINISHED GRADE BW=629.0 40.67' _ 6 20.22' _ _ 26' - TW=638.5 _\, FINISHED GRADE � oi PEAK WSEL G v 100 YR = 633.40 opSS � DE EXISTING GRADE Mo% N BW=629.00 �✓ SLpSIDE PE CONCRETE FLUME B-B CROSS-SECTION SCALE: N.T.S. a 0 (V V N O PAL23001 - PALLADIUM E. LANCASTER E i! PELOTON DETENTION POND PLAN d I I LAND SOLUTIONS o FORT WORTH -TEXAS S SEPTEMBER 2023 a 0' 100, C12 A OUTLET STRUCTU RE TA BLE PALLADIUMLANCASTER POND(P Palladium) OUTLET PIPE EM ERG ENCY WEIR MATERIAL HOPE EMERGENCY OVERFLOW Q(CFS) 79.7 SHAPE CIRCULAR WEIR COEFF,4 3.30 BARRELS 1 WEIRLENGTH(FT) 25.0 DIAMETER 36" CREST ELEV(ft) 633.40 LENGTH (FT) 34 TOP OF POND Ift) 635.00 U/S INVERTELEV. 6240D I WEIR HEAD CALCULATI D/S INVERT ELEV. 623.32 I QdU1V' 0.023 I HdQ/(CL))' Ke 0.5 HQN.7/13.3e251\�"' RISER SM( Head, H(Tt) 1.1 SHAPE RER Emergenry WSEL(ft) 630.50 DIMENSIONS 4FT%4FT Emer.enI�/�F reeboard kl 0.5 FLOWUNEELEV 624.OD I DD�NSYRFAMIN 'AOTY BO%TOP ELEV 63"50 EMERGENCY OVERFLOW Q(CFS 82.5 1 PRIMARY Ofer(ORIFICE) ORIFICE COEFF, C,. 0.67 SS�({{�r(( FEET ORIFICEAREA(W) 25.0 FLOWUNE ELEV VIEW CLOGGI NG FACFOR (%) SIX BARRELS I EFFECTIVE OPEN AREA (FT' 12.5 WIDTH W RIM ELEV(ft) ... HEIGHT I.. TOP OF WALL//ft 635.00 AREA 3.0 I WEIRHEADCALCULA� ORIFICECOEF, 0.67 Q-CA(2Rh)'r' RISER80X.0P H=IIWCAI'1/t SHAPE RECr H=k82.5/0.67-12.51111/2-32.2 1987 CATCH BASIN INLET FRAMES. SOLID COVERS OR GRATES Utbux�b.t • a [ r r a o In e. x9N A tba YrH .e r sr tRWglle4 b 41euHn4 Mmnr4pN4 meW plpe. Plpeslu In6ub41n NHeaMaN bNgv. Tx 1' ORIFICE OPENING ELEVATION 631.5 I Head,rH(ft) 1.1 PERIMETER(T16 Em1r:WSEL(ft) 634.5 0 COVERMATERIAL 24xoEmFmboad(ftl 0.5 AREA(F1') I ORIFICE COEF. 0.67 CATCH BASIN INLET FRAME_------ RAME 4811 co(PER DETAIL 1987) °O 1 ELEVATION, VOLUME, DISCHARGE TA BILE FOR PALLADIUM LANCASTER POND (P_Palladium) INCREM. TOTAL DRAWDOWN TWIN' , ELEVATION DEPTH AREA STORAGE DISCHARGE* STORAGE TIME Elevation (ft) (ft) (sry (d) (cry Ids) (h:mm) (ft) 1 628.00 0.0 0 0 0 0.00 0:00 623.32 1 629.00 1.0 7,113 2,371 2,371 11.22 0:02 628.89 1 630.00 2.0 8,802 7,942 10,312 26.39 0:05 629.67 1 631.00 3.0 9,591 9,193 19,505 55.97 0:10 630.29 632.00 4.0 9,984 9,786 29,291 88.74 0:15 630.70 633.00 5.0 10,414 10,197 39,498 94.43 0:19 630.93 634.00 6.0 10,995 10,702 50,190 138.14 0:23 631.14 635.00 7.0 11,250 IL121 61,312 400.29 0:26 631.36 Discharges listed have been interpo.ated from the HEC-HMS timeseries data ROUTING SUMMARY FOR PALLADI7M LANCASTER POND (P_Palladium) PEAK DRAWDOWN STORM QIN Q.. PEAK WSEL DETENTION TIME FREQUENCY STORAGE (ds) (ds) (ft) (ac-ft) (h:mm) 2-yr Prop 33.4 24.8 629.9 0.10 0:03 5-yr Prop 46.3 27.3 631.1 0.40 0:11 100-yr Prop 81.6 50.9 633.4 1.00 0:23 100-yr Ultimate 81.6 50.9 633A 1.00 0:23 EL Emergency Overflow 81.6 79.7 634.5 1.30 0:27 N_ V E H11111 P E LOTO N d��� LAND SOLUTIONS 9 0 0- \,3' x 1' ORIFICE OPENING PRIMARY OUTFALL STRUCTURE N.T.S. TOP VIEW RISER BOX TOP ELEV. 631.50 4'X4' CONCRETE \ 1 JUNCTION BOX 1\ PRIMARY OUTFALL \-FL: 624.00 STRUCTURE N.T.S. FRONT VIEW RISER BOX TOP ELEV. 631.50 Tx 1' ORIFICE OPENING FL= 628.00 1 (BOTH SIDES) tr 4'X4' CONCRETE I LT 1 �\ JUNCTION BOX FL:624.00- PROP. Q _ J9D sD PRIMARY OUTFALL Cl) STRUCTURE SIDE VIEW PAL23001 - PALLADIUM E. LANCASTER DETENTION POND DETAILS FORT WORTH -TEXAS SEPTEMBER 2023 FoRTWouR.l CITY 01 FORT WORTH, TEXAS I STA,N NAT ONBQOX RE ` REV BED: 111111111 334910-D410 54" RCP @ 0.26 % ' \ FL ELEV. = 623.32 B. 24 10 LF 36" RCP @ 1.00% FL ELEV. = 623.32 A-db END 36" RCP FL ELEV. = 623.42 91 2% 2% r 4" 3,600 PSI CONCRETE CONCRETE FLUME W/#3 BARS @ 18" OCEW 2 SCALE N.T.S. EXISTING 42" RCP FL ELEV. = 623.00 CONCRETE PIPE COLLAR 48" RCP FL ELEV. = 623.32 -_­_ _�( 4" CONCRETE APRON I /gip 12' Y-TOP STD. 5' x 5' JUNCTION BOX WITH W/ #3 BARS @ 12" OCEW RIM= 633.00 Y-TOP FL ELEV. = 623.32 RIM= 633.00 48" RCP FL ELEV. = 623.32 54" RCP @ 0.26 % FL ELEV = 623 32 k 25 23 B L �A (CONT. BY OTHERS) WEIR 27' ELEV. = 633.40 12" _ 25' 12" _100 YR WSEL=]33.20 12 BOTTOM OFFOOTER TOP OF FOOTER (BEHIND) ELEV. = 628.00 ELEV. = 629.00 SECTIONA A TOP OF DRAINAGE STRUCTURE EMERGENCY OVERFLOW WEIR FL= 633.40 ELEV.= 635.00 EG 27 25' 1 7 ST . 5' x 5' JUNCTION BOX WITH FL ELEV. = 623.32 36" RCP FL ELEV. = 623.32 SECTIONB-B EMERGENCY OVERFLOW WEIR FL= 633.40 TOP OF DRAINAGE STRUCTURE EG ELEV.= 635.00 24" STD. 5' x 5' JUNCTION BOX WITH 4" CONCRETE APRON Y-TOP W/ #3 BARS @ 12" OCEW 12 RIM= 633.00 FL ELEV. = 623.32 I END 36" RCP 54" RCP @ 0.26 FL ELEV=623.42 FL ELEV. = 623.32 (CONT. BY OTHERS) 48" RCP @ -1.00 10 LF 36" RCP @ 1.00 % FL ELEV. = 623.32 FL ELEV. = 623.32 SECTION GC SECONDARY OUTFALL STRUCTURE DETAIL PAL23001 - PALLADIUM E. LANCASTER of 100, PELOTON DETENTION POND DETAILS C11 LAND SOLUTIONS FORT WORTH -TEXAS SEPTEMBER 2023 Plot Date/Time:2/21/2024 12:10 PM 'm z or, . 0r. C� -0 0 p Z M m o 0 r el m a m wczmel = X ZN X wN m � r OD z 71 D rU) M m x 0 n CD A O G) _ N N co CA) P cn O cn O cn O cn O c+3� SD-H STA 0+00.00 = O fSD-A STA 0+00.00 INSTALL: 5'X5' JUNCTION BOX T CONSTRUCT DROP INLET 00 PER OUTLET STRUCTURE TABLE BEGIN 36" RCP O I O FL 36" (OUT)=623.3� O SD-H STA 0+09.50 u, �j CONNECT TO PUBLIC 36" RCP FL 36" (IN)=624.00 I m m r m m W in Q CD r- I o rr alp �I� T x m M SD-H STA 0+34.22 > MINSTALL: + o 1-4'X4' RECT. RISER BOX O p cn m t m W/ CATCH BASIN INLET FRAME O (� 7 z r (SEE DETAIL) rn �, 14co 1 TOP OF BOX=631.50 D �' CD CD cn 0 PRIMARY OPENING FL=628.00 o RISER BOX FL=624.00 M REF DETAIL SHEET + cn O C3� O O cn O C3� cn 2 G:\JOB\PAL23002_Pal.adium_E_Lancaster\3_Design\35_Civi�351_CAD\SWFMA Plans\PAL230021-C-STORM x �10' UTILITY ESMT. I -_14-- - N V i! P E LOTO N d I I LAND SOLUTIONS 0 0 d I---S UTILITY ESMT. of I FUTILITY ESMT. c — -EX M �I / 10 6 - EX SS - - - M I I aI M •[ 5' SANITARY SEWER ESMT. / - PROP. SWFMA ESMT. � O cr OUTSIDE ENSURE SILT FENCE IS 5' OF EMERGENCY / I SPILLWAY I � 2 --=W--- W � Z \> q W N PAL23001 - PALLADIUM E. LANCASTER EROSION CONTROL PLAN FORT WORTH -TEXAS SEPTEMBER 2023 NOTE: NO SAVED OR PROPOSED TREES ARE WITHIN THE SWFMA BOU N DARY SF PROPOSED SILT FENCE LOC PROPOSED LIMITS OF CONSTRUCTION TP PROPOSED TREE PROTECTION ® INLET PROTECTION NOTE: NO SAVED OR PROPOSED TREES ARE WITHIN THE SWFMA BOUNDARY C2 III i! P E LOTO N d I I LAND SOLUTIONS 0 0 0- �ST�EEL oa MroW PasTAT6 c c (MAXI m Rlcua Oa uNEwIRES MIN ,z„z OA INTEaMEMArewIaES MIN, MIRAR— OR APPROVED EQUAL N� u i TRENCR RACRwLLACOMPACT r Y CSILTsFENCE 1 .......... ENOs.TRANI3.—ToouTTERINRETwEEN CROSS SECTION iMHAND A F�wc J ONANAcmEs.REET O O FILTER _RC INN sIOe JJ PLAN VIEW CURB INLET PROTECTION 2 NOT TO SCALE NOTES 1-SEE SPECIFICATIONS FOR ADDITIONAL TREE PROTECTION REQUIREMENTS CRS RIjI/NlC(�R()J}{FjjJLf T[]F7fjF�Pf�QTf(.'�TI(j% TREA 21F THERE IS NO EXSTING IRRIGATION, SEE �H VR�S�IlVA��!{�L��FUNF @C�11L�GW�E SPECIFICATIONS FOR WATERING REQUIREMENTS. ED 1 NO PRUNING SHALL LL OPERATE INIIIE HE BY APPROVED ARBORIST 4-NOEQUIPMENTSHAMOVAL. ATE INSIDE THE PROTECTIVE FENCING INCLUDING DURING FENCE INSTALLATION AND REMOVAL. �1 WITH THE TREE PLAN FOR ANY MODIFICATIONS VwYIY�—] WITH THE TREE PROTECTION AREA. TREE PROTECTION FENCE \ HIGH DENSITY POLYETHYLENE S.V' x 11" SIGN FENCING WITH 3.5' x 1.5' LAMINATED IN OPENINGS, COLOR -ORANGE PLASTICSPACED STEELPOSTSINSTALLEDATS' EVERY SO' ALONG P O.C. THEFENCE 2" STEEL POSTS OR APPROVED EQUAL d 5' THICK LAYER OF MULCH. KEEP OUT MAINTAIN EXISTING GRADE TREE WITH THE TREE PROTECTION < PROTECTION FENCE UNLESS OTHERWISE nocn INDICATED ON THE PLANS SECTION VIEW OTREE PROTECTION DETAIL 3 SCALE NIS. PAL23001 - PALLADIUM E. LANCASTER EROSION CONTROL PLAN DETAILS FORT WORTH -TEXAS SEPTEMBER 2023 C3 III ANCHOR DIAMOND Group INSTALLATION GUIDE Al k I I ANCHOR DIAMOND i i r.,ao�o __.DUSTRY EXPERTS JAL ANCHOR DIAMOND" 1, s�- — ;C ,rg r 47, ta• - DIAMOND PRO° RETAINING WALL SYSTEM ANCHOR DIAMOND Group For more info visit on 5909 Baker Rd. Suite 550 AnchorDiamond.com ® Tube Minnetonka, MN 55345 `1-952-933-8855 ©2023 ANCHOR DIAMOND Group All rights reserved. Table of Contents RETAINING WALL BASICS ;���; ANCHOR and How to Use This Guide TABLE OF CONTENTS HOW TO USE THIS GUIDE ..................... 2 BEFORE YOU BEGIN ........................ 2 RETAINING WALL BASICS ..................... 3 RETAINING WALL INSTALLATION INSTRUCTIONS Installation Instruction Overview ............... Running Bond ................................................. Cappinga Wall ................................................. Drainage ... .... ... .... .... .... Inside 90' Corners ......................................... Inside 90' Corners with Reinforcement.. Outside 90' Corners ...................................... Outside 90' Corners with Reinforcement Inside Curves ................................................... Inside Curves with Reinforcement............ Outside Curves .... ... .... .... .... Outside Curves with Reinforcement......... Guardrails......................................................... Fences................................................................ Terraces............................................................ Water Applications ......................................... f011111111ANCHOR DIAMOND" 4 6 7 8 9 10 11 11 12 13 14 15 16 17 18 19 HOW TO USE THIS GUIDE This guide is designed to provide you with ideas as well as information on product use and installation procedures. Because actual project conditions vary, final wall design, including the incorporation of geosynthetic reinforcement, must be performed by a qualified engineer While this guide provides general guidelines, installation contractors should refer to construction drawings provided by a qualified local engineer for final specifications. Additional installation information is available online at anchordiamond com. Information includes basic wall construction as well as other applications, including. 90' corners terraced walls • curves • water applications cap placement • fences • guardrails BEFORE YOU BEGIN Advance planning and careful layout at the lob site help ensure a successful retaining wall project • Review the site plan to confirm lot lines, wall location, length and elevations. • Understand on -site soils Ideal soils are sand and gravel. For walls built in clay or poor soils, work with a local engineer to confirm the wall design and the required soil reinforcement Black or organic soils should not be used as backfill • Confirm the location of underground utilities. • Seek all necessary building permits. • Prepare a drawing of the site with the wall location, lengths and elevations. • Plan drainage to prevent erosion or buildup of water behind the watt Consider where the water will drain through the wait, where downspouts will expel water and whether there's an underground sprinkler For walls greater than 3 feet in height, a perforated drainpipe is recommended at the base of the aggregate to quickly remove large amounts of water. See page 19 for more information on water applications • Check the block delivered to ensure it is the correct color. Check the geosynthetic reinforcement to confirm that it's the strength and weight specified in the engineering plans • Be sure to use the right tools. Hand tools include a shovel, 4-foot level, dead -blow hammer, 2- or 3-pound hammer, chisel, hand tamper, hydraulic splitter and string line Power tools include a circular saw with a masonry blade and a compactor. • Always wear protective eyewear Segmental retaining walls typically fall into one of three categories. GRAVITY RETAINING WALL The first category - a gravity wall - is a retaining wall that does not use soil reinforcement. A gravity wall has height limitations specific to each product. An advantage of this type of retaining wall is that it requires a smaller work area behind the wall. A gravity wall relies on the weight and setback of the block to resist the soil forces being exerted on the wall. GEOSYNTHETI C-REINFORCED RETAINING WALL Filter fabric walls, and they are used in larger applications. They require more work area behind the structure. The block of soil is stabilized by introducing reinforcement layers into the soil mass behind the facing units. The larger the stabilized soil mass, the more soil can be retained or held back. The geosynthetic reinforcement in the soil extends past the theoretical failure plane and serves to create a large, rectangular mass of block and soil, restraining the retained soil. ANCHORPLEXT" RETAINING WALL SYST EM Topsoil Filter fabric Level The third category is the AnchorplexT" retaining wall system, which offers a unique, nonconventional solution to problematic wall construction sites. It is a retaining wall built with Anchor products and self -compacting structural backfill specified by ANCHOR DIAMOND Group, and backed by engineering support tools Low - permeable Y developed b Anchor. per soil Use of the Anchorplex retaining wall system completely Reinforced eliminates the need for the construction of a mechanically soil zone stabilized earth zone behind the wall facing and requires substantially less excavation than is usually necessary in grid - reinforced wall construction. \ Geofo ceme'rcif For more information about the Anchorplex retaining wall ref" system, go to anchordiamond.com. pad Drainpipe Drainage aggregate The second category is a geosynthetic-reinforced wall, which needs to be designed by a qualified engineer. There are (theoretically) no height limitations with reinforced retaining INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 111P11 ANCHOR DIAMOND Diagram 1—Excavat,on Diagram 2—Leveling Pad 0 iagram 3—Base course Diagram 4—Cora Fill 1. STAKE OUT THE WALL • Have a surveyor stake out the wall's placement. Verify the locations with the protect supervisor 2. EXCAVATION • Excavate for the leveling pad to the Imes and grades shown on the approved plans, and excavate enough soli from behind the wait for the geosynthehc reinforcement material • The trench for the leveling pad should be at least 2 feet wide and a minimum of 1 foot 2 Inches deep, enough to bury the first course below grade, plus 6 inches for the leveling pad Ensure that a minimum of 8 inches or 10 percent of the total wall height (whichever is greater) is below grade. See Diagram 7. 3. LEVELING PAD • An aggregate leveling pad is made of compactible base material of 3/ inch minus with fines • If the planned grade along the wall front will change elevation, the leveling pad may be stepped up by the height of the block (typically 8-inch increments) to match the grade change Always start at the lowest level and work upward. • Compact the aggregate, making sure it's level front to back and side to side Mist lightly with water before compaction, if needed. See Diagram 2 4. BASE COURSE • This is the most important step in the installation process • Begin laying block at the lowest elevation of the wall, whenever possible Remove the rear lip of the block by hitting with a hammer and chisel from the back so that the block will lie flat on the leveling pad • Place first block and level, front to back and side to side, lay subsequent blocks in same manner. • Place the blocks side by side, flush against each other, and make sure the blocks are in full contact with the leveling pad. Level front to back and side to side • Place soil In front of the base course and compact. Base course should be buried. Continue to fill and compact after each course is laid • If the wall is on an Incline, don't slope the blocks. Step them up so they remain consistently level • Use string along back edge of the block to check for proper alignment. See Diagram 3. S. CONSTRUCT ION OF THE NEXT COURSE • Fill cores and voids between blocks with A -inch clean drainage aggregate prior to laying the next course of block. Clean any debris off the top of the blocks • Place the second course of blocks on top of the base course Maintain running bond Pull each block forward as far as possible to ensure the correct setback. • Backfill with drainage aggregate directly behind the block, adding 6 to 8 inches at a time Add soil fill behind the aggregate. • Compact before the next course is laid Don't drive heavy equipment near the wall Self-propelled compaction equipment should not be used within 3 feet of the back of the wall • You'll need partial units to stay on bond. A circular saw with a masonry blade is recommended for cutting partial units Use safety glasses and other protective equipment when cutting. See Diagrams 4 and 5 6. DRAINAGE DESIGN • Each protect is unique The grades on the site will determine at what level to install the drainpipe Place the drainpipe (4-inch perforated piping) so water drains down and away from the wall into a storm drain, or daylight just above grade • Fit[ in the area behind the blocks with clean drainage aggregate, at least 1 foot from the wall You may need to place and Backfill several courses to achieve the proper drainage level. • The outlet pipes should be spaced not more than every 50 feet and at low points of the wall. In order for the drainage aggregate to function property, it must keep clear of regular soil fill See Diagrams 6 and 7. Diagram 5—NexbCourae Constructlon Diagram 6-0rainage Diagram ]—Backfill Diagram 8—Compaction 7. COMPACTION • Shovel the backfill soli behind the drainage aggregate and compact the backfill with a hand - operated compactor Make surethe aggregate is level with or slightly below the top of the base course • Continue to fill and compact after each course is Laid See Diagram 8 8. REINFORCEMENT (IF REQUIRED) • Geosynthenc reinforcement is recommended for walls taller than 4 feet or walls situated in poor soils, supporting a driveway, etc. Consult an engineer for design assistance • Check the wall construction plan to determine which courses will need reinforcement Clean any debris off the top layer of blocks Measure and cut the reinforcement to the design length in the plans The reinforcement has a design strength direction, which must be laid perpendicular to the wall • Place the front edge of the material on the top course, 1 inch from the face of the block. • Apply the next course of blocks to secure it in place. To keep it from wrinkling, pull the reinforcement taut and pin the back edge in place with stakes or staples • Add drainage aggregate behind the blocks, then add the backfdl soil and compact it. • Correct placement ensures that you maximize the connection strength and keep the batter consistent. A minimum of 6 inches of backfdl is required prior to operating vehicles on the reinforcement 9. CAPPING A WALL • Always start capping from the lowest elevation If the wall elevation changes, caps can be stacked where the wall steps up • Lay caps at the elevation change and work back toward the previous step up. Cut caps with a diamond -blade saw to fit, as needed • Carefully glue with a high -strength concrete adf— • If the wall is on an Incline, don't slope the blocks Step them up so they remain consistently level. • Use string along back edge of the block to check for proper alignment See Diagram 3 10. FINISH FRADE AND SURFACE DRAINAGE • Protect the wall with a finished grade at the top and bottom To ensure proper water drainage away from the wall, use 6 inches of soil with low permeability and seed or plant to stabilize the surface • Consult the wall design engineer if water may be directed behind the wall. If needed, create a swale to divert water away from the wall This will minimize water seeping into the soil and drainage aggregate behind the wall. 11. SITE CLEANING AND RESTORATION • Brush off the wall and pick up an debris left from the construction process. Notify the job superintendent in writing of the completion and that it is ready for final inspection and acceptance • Planting vegetation in front and on top of the wall will help reduce the chance of erosion • Following these best practices for construction will ensure the success of your ANCHOR DIAMOND Group retaining wall These instructions are meant as general guidelines Site -specific conditions may warrant additional installation requirements. • ANCHOR DIAMOND Group recommends you consult a professional engineer to design walls over 4 feet high, and have compaction tested by a qualified geotechnical engineer SAFETY NOTE: Always use appropriate equipment, including safety glasses or goggles and respirators, when splitting, cutting or hammering units RUNNING BOND STRAIGHT WALL Proper installation of an Anchor' retaining wall requires that running bond be maintained. Running bond occurs when the blacks are centered over the vertical joints of the previous course This adds to wall stability and makes the wall aesthetically beautiful. OUTSIDE CURVED WALL Any wall that is not perfectly straight will eventually run off bond When this happens, skip a block position and place the next block into the next place where it is back on bond. Measure the remaining gap and cut or split' a block to fit Once the partial unit is in place, glue with a concrete adhesive. Partial units must not be less than 8 inches long, and should not be placed directly on top of each other. If the gap is larger than the length of one block, divide the measurement by two and put two partial units in place Tip It may be possible to run the off -bond block into the soil bank to avoid cutting of partial units "To split a block, use a hydraulre sptitter or split manually by using a hammer and chisel to score the block on all sides Pound the chisel on the same line until the block splits. If partial unit sides are not exposed, use a circular cut-off saw with a masonry blade to achieve a tighter tit STEP 1- PLACE REINFORCEMENT SO LITTLE OR NO OVERLAP OCCURS IN THE RADIUSAREA IF OVERLAPOCCURS PLACE2103 �wwr rnwa.e.wc w+�Trrl FII%�I I I I yl I I I I I it I I- I I I I 1! „.FyPasEDAWxKrr Tn„rEw LI I I I I I I I •E*� �••»A.� II I I I I I I I noAUT waaaAS NeEceoro NNM+�N R�/yg9pq \ LrNweo aA.aL `rawrrwrre+ee aA+MAAA�Au uvuHarin PRINCIPLE REINFORCEMENT DIRECTION INCHES OF SAND BETWEEN THE - REINFORCEMENTLAYERS. Y-W OF SOIL FILL REQUIRED STEP 2: LAY THE NExT COURSE - f, BETWEEN OVERLAPPED\\. OF BLOCK, MAKE NARKON REINFORCEMENTFORPROPER THE BACK OF THE BLOCKS IN SOIL AND REINFORCEMENT THE AREAS THAT ARE NOT INTERACTION O REINFORCED. BACKFILL AND To COMPACT THAT COURSE .- O O MINIMUMRADIUS Q p 4 FT. TO FACE STEP 3: PLACE REINFORCEMENT 1 IN THE AREAS WHERE THE MARKS 1 SHOW GAPS IN THE LOWER O RE INFORCEMENTPATTERN, CONTINUE NORMAL WALL Q CONSTRUCTION. REPEATING THESE STEPSAS NEEDED. 1" O as CAPPING A WALL STRAIGHT WALL Always start capping from the lowest elevation Caps are trapezoidal and must be laid alternately short and long cap faces for a straight line Cap units are supplied with a recess to the bottom of the unit to accommodate the locator, and should always be laid with the recess facing downwards OUTSIDE CURVES Lay out the cap units side by side and cut at least every other cap to produce a uniform look Start with the long side of the cap facing out and adjust to the radius. INSIDE CURVES Lay cap units side by side with the short side facing out In most circumstances, making two cuts on one cap and then not cutting the cap an either side produces the most pleasing look. CORNERS On a 900 corner wall the corner caps need to be saw -cut to achieve a 450 mitered corner. FINISHING After layout is complete and caps are saw -cut to size, carefully glue the caps in place using a concrete adhesive. zi�% OUTSIDE CURVE SAW CUT AS REQUIRED TO CONSTRUCT 900EGREE MITERED CORNER INSIDE CURVE TOP 1 / 1 SPLIT FACE AND END 1 1 1 I WALL FACE 1. ALWAYS START CAPPING WALL FROM THE LOWEST ELEVATION. 2. LAYOUT CAPS PRIOR TO USING ADHESIVE. 3- CUT CAPS TO FIT. VARIOUS COMBINATIONS OF LONG AND SHORT CAP FACES WILL BE NECESSARY FOR RADII GREATER THAN THE MINIMUM. 4. ALTERNATE SHORT AND LONG CAP FACES EVERY OTHER CAP TO ACHIEVE A STRAIGHT ROW OF CAPS. S. USE EXTERIOR -GRADE CONSTRUCTION ADHESIVE TO SECURE CAPS. ANCHOR I I DIAMOND DRAINAGE CORNERS — INSIDE 900 ��DOANCHOR DIAMOND Good drainage Is critical to ensuring the long-term performance of Anchorw products. Water collected from the drainage fill behind the wal must be able to drain down and away from the wall into storm drams or an area lower than the wall, either at the end of the wall, via a carrier drain or through drainage weep holes. FIRST COURSE If the wall is longer than 50 feet, drainage weep holes must be Installed through the wall face, no more than 50 feet apart. Remove 2 inches off the front of two adjacent blocks to provide sufficient space for the drainpipe to exit through the face to farm the weep hole NEXT COURSE Budd this and remaining courses using standard construction techniques �� �� or r ow rERroRArED AWACENr NaIS TO ALLOW rTEE GRAM THE IEL VAPEA sLarE L�uN.t wuw nE naurA¢1 DA rw rart —V� 1 1 1 W AmcaR.oE 1 I tit'MIRK KLOw'GMK aocouRee �LawaRAnE I YACMG vA1tlE4 x uA+vuu REMOVE PORTION OF - -. A�DIJACENT UNITS TO ALLOW<•TEE (�r'�C•OPERFORATED l✓ U U '.�,- -- THRU-FA� - O� E 1%MERj� 2•CUT �— DAYLIGHT DRAIN THRU WALL FACE & EXTEND THIRD SLOPE 2NOCOURSE f 19T COURSE �I I SPACING VARIES 50'MA%IMUM BASE COURSE To create an inside 900 corner, begin by placing a block at the corner Then lay a second block perpendicular to the first and continue laying out the rest of the base course working from the corner out ADDITIONAL COURSES On the second course, place all blocks in a running bond along one side of the corner Once the second course of one wall is established, begin the second course of the adjacent wall Several blocks away from the corner, position full blocks In a running bond. Continue the running bond back towards the corner, until the gap becomes less than a full unit. Split* units may be required on this wall to mamtaln a running bond SUBSEQUENT COURSES Block placement In the corner must alternate In direction with each succeeding course. The locator of the block being overlaid within the corner should be removed using a hammer and chisel, and these units should be glued In place using a concrete adhesive 'To split a block, use a hydraulic sphtter or split manually by using a hammer and chisel to score the block on all sides. Pound the chisel on the same line until the block splits If partial unit sides are not exposed. use a circular cut-off saw with a masonry blade to achieve a tighter fit CUT UNITS (X)TO MAINTAIN RUNNING BOND � r�1Co�a c1f� c1 D lD 11D FIRST LD COURSE jIC WDV1 bK bA D JD THIRD COURSE Co. ;D SECOND COURSE ;D ;D ,D j� FOURTH COURSE D ,D ;D �D CORNERS - INSIDE 900 WITH REINFORCEMENT FIRST COURSE WITH REINFORCEMENT To install reinforcement on an Inside 900 corner, begin by checking the wall plan to determine reinforcement lengths and elevations Cut reinforcement to the lengths shown in the wall plan, paying attention to the reinforcement strength direction. Next, determine the proper placement of the reinforcement by dividing the proposed height of the wall by four. This represents the distance that reinforcement must extend beyond the front of the adjoining wall Measure this distance from the front of the adjoining wall and begin the grid placement here. Make sure the grid is placed 1 Inch back from the face of the block below and runs along the back of the adjoining wall EXAMPLE: If overall wall height is 4 feet, the reinforcement extension would be 1 foot. Place the next section of reinforcement on the adjoining wall The reinforcement must not overlap and should lie flush with previously placed sections. Once reinforcement is in place, the next course of blocks can be installed SECOND COURSE WITH REINFORCEMENT The first section of grid on this course is placed using the same formula that determines placement in front of the adjoining wall Alternate the reinforcement extension on each course where reinforcement is required. Place the next section of reinforcement on the adjoining wall The reinforcement must not overlap and should lie flush with previously placed sections Once reinforcement CORNERS - OUTSIDE 900 AND CORNERS - OUTSIDE 900 WITH REINFORCEMENT BASE COURSE To build an outside 900 corner, begin by placing a corner unit and working from the corner unit outward NEXT COURSE Lay a corner block perpendicular to the one below and glue the block in place with concrete adhesive. Two or three blocks away from the corner lay full blocks, maintaining running bond with the course below Lay blocks back towards the corner block, leaving space for the final split units" required to complete the course. Use split units immediately adjacent to the corner block to complete the course Continue to alternate the corner unit orientation with each IW �' course and always use a concrete adhesive on all corner units and RE NFORCEVENT H4 MYOND THE THE split units. CORNER AT SPECIFIED RE NPORCLMLNT ELEVATIONS 1'. RUNNING BOND - HI ExTYNsroN Use split units" as necessary to maintain running bond or e�ocA split a block, use a hydraulic splitter or split manually by using a Hl hammer and chisel to score the block on all sides. Pound the chisel on the same Ims until the block splits. If partial unit sides are not exposed, use a circular cut-off saw with a masonry blade to achieve a tighter lit. NOTE PUOENENT OF W CEMEM EXTENSION ON SFEPEGFWFIEO ••••• ••••••• ••••••• REINFORCEIENT ELEVATIONS. '. •••••••: ••••• •: FIRST COURSE WITH REINFORCEMENT _ Begin by checking the wall plan to determine reinforcement lengths and elevations Lay a section of reinforcement near the corner of the wall, ensuring that it is placed within 1 inch of the face of the block and running along the back of the adjacent wall. ADDITIONAL COURSES Lay the next course of blocks and before ba ckfdhng, mark the portion of the wall without reinforcement This is important, because once the backhll is in place this cannot be seen. I W Lr¢crlox "I ANCHOR DO DIAMOND Backfdl and compact behind the course of blocks Cut an additional length of grid to correspond to the marked section of blocks. This grid should be cut to the length shown in the drawings and laid so that it is placed 12 inches back from the wall face, while running along the back, but not overlapping the adjacent wall. Repeat this procedure at each reinforced layer within the wall, alternating the alignment of the additional layer of reinforcement at each elevation NOTE IN THE'CROSS�OVER AREA' OF REINFORCEMENT. ONE OF THE LAYERS OF REINFORCEMENT SHOULD BE LOWERED OR RAISED ONE COURSE TO ALLOW PLACEMENT OF THE REINFORCEMENT WITH THE PRINCIPLE REINFORCEMENT STRENGTH DIRECTION PROPERLY ORIENTATED_ THE REINFORCEMENT SHOULD NOT EXTEND INTO THE SEGMENTAL RETAINING WALL UNITS ON THE RETURN LEG OF THE 906DEGREE CORNER INSIDE CURVE WITH REINFORCEMENT CURVES - INSIDE DOANCHOR WITH REINFORCEMENT DIAMOND CALCULATE THE RADIUS Check the wall plan to determine the radius of the base course. This will be the smallest radius in the wall and must not be less than the m mi mum for the black system used A quick way to determine the base course radius 1) Add 1 /4 inch to the setback of the block used Multiply that by the number of courses in the finished wall. 2) Subtract the result of step 1 from the radius of the top course This number equals the approximate radius length of the base course. 3) To determine the red ins for the front edge of the trench, subtract 6 inches from the approximate radius length of the base course. Example: The setback of Diamond® Pro products with a 4-degree system batter is 9/16 inch. The wall is 6 courses high. The desired radius of the wall measured to the front of the block on the top course is 10 feet 11 Setback multiplied by number of courses I. + /,' = 1 1 /4' x 6 courses= 71h" 21 Desired radius minus setback 10 - 7'/1' = 9' 4/,' 3) Distance to front of trench 9'41/V-6'=3'4%" TipAdd the depth of the block if you prefer to mark the curve from the back of the block LAY OUT THE TRENCH Drive a stake into the ground at the desired radius point of the curve Attach a string and rotate it in an arc at the desired length to mark the curve in the soil Dig the trench. BASE COURSE Using existing radius point stake and string, mark the base course curve on the leveling pad. Align the front of the block with the marked curve and ensure level placement from side to side and front to back ADDITIONAL COURSES On each course, the hp of each block must be in contact with the back of the units below to ensure structural stability. 10 INSIDE CURVES W8 (NOT TO SCALE) Most retaining walls are designed assuming 100 percent coverage of the reinforcement. When building an inside curve the reinforcement will fan out, producing slight gaps In order to ensure 100 percent coverage, additional lengths of reinforcement are used to fill those gaps on the next course of blocks Don't overlap the grid on any given course. FIRST COURSE WITH REINFORCEMENT Cut reinforcement to the lengths specified in the wall plan Lay segments of reinforcement within 1 inch of the face of the wall, making sure that the strength direction of each section is perpendicular to the wall face. Avoid overlapping the reinforcement by separating each section NEXT COURSE Place the next course of blocks, marking their backs to identify unremforced areas. This step is important because when this course is backfdled, it's impossible to locate the unremforced areas Use the marked blocks as a guide, placing subsequent sections of reinforcement to overlap the gaps left on the previous course. This will ensure total reinforcement coverage ADDITIONAL COURSES Repeat this procedure throughout the construction of the curve whenever reinforcement is required MINIMUM INSIDE RADIUS The minimum radius varies by product. Please check Product Information for the product you are using at anchordiamond com CURVES - OUTSIDE CURVES - OUTSIDE DO ANCHOR WITH REINFORCEMENT DIAMOND LAY OUT THE RADIUS When building an outside curve, begin by determining the desired radius of the top course at the wall face This will be the smallest radius in the wall and must not be less than the minimum radius for the block system used. To determine the approximate base course radius 1) Add Yn inch to the setback of the block used. Multiply that by the number of courses in the finished wall 2) Add desired radius length of the top course to the result of step 1 This number equals the approximate radius length of the base course. 3) To determine the radius for the front edge of the trench, add 6 inches to the approximate radius length of the base course Example: The setback of the Diamond Pro- product with a 4-degree system setback is 9/rn inch The wall is 8 courses high The desired radius of the wall measured to the front of the block on the top course is 6 feet 1) Setback multiplied by number of courses I. + M" = C/a" x8 courses= 10" 2) Desired radius plus setback 6'+10'=6'10' 3) Distance to front of trench 6' 10' + 6' = T4' TipSubtract the depth of the block if you prefer to mark the curve from the back of the block LAY OUT THE TRENCH Drive a stake into the ground at the desired radius point of the curve Attach a string and rotate it in an arc at the desired length to mark the curve in the sail. Dig the trench. BASE COURSE Drive a stake into the ground at the desired center of the curve. Attach a string and rotate it in a circle around the stake to mark the radius in the soil Align the front of the block with the curve and ensure level placement from side to side and front to back. ADDITIONAL COURSES On each course, the hp of each block must be in contact with the back of the units below to ensure structural stability MINIM 4 FT. " Most retaining walls are designed assuming 100 percent coverage of the reinforcement. When building an outside curve the reinforcement will have gaps, and the back edges don't overlap To ensure 100 percent coverage, additional lengths of reinforcement are used to fill those gaps an the next course of blocks. Don't overlap the grid on one course. FIRST COURSE WITH REINFORCEMENT Cut reinforcement to the lengths specified in the wall plan. Lay sections of the reinforcement within 1 inch of the face of the wall with the strength direction perpendicular to the wall face. Avoid overlapping the reinforcement by separating each section NEXT COURSE Place the next course of blocks, marking their backs to identify unremforced areas. This step is important because when this course is backf fled, it's impossible to locate the unremforced areas Use the marked blocks as a guide, placing subsequent sections of reinforcement to overlap the gaps left on the previous course This will ensure total reinforcement coverage Repeat this procedure throughout the construction of the curve when reinforcement Is required. ADDITIONAL COURSES Repeat this procedure throughout the construction of the curve whenever reinforcement is required MINIMUM RADIUS Each product has a unique radius Check the Product Information on anchordiamond com Naa�oac,:wn oaraowa�. CCCUa6 N TE 0.rpitl NRA i anavooaws.aws a roa axaEsaswoearvce+rwE wriowwNcxr urns rry ao. ru. uouNao uaioxeNlNr roa rgorea saaiuoraasaxrawr NrDvcrip� GUARDRAILS Impact on a guardrail system will transfer additional loads to the top of the wall These additional loads must be accounted for in the design and construction of the watt A qualified engineer should always be consulted to determine the likely loads the guardrail will transfer to the wall and to produce a wall design that takes these in to account Consult a qualified engineer before design, construction and installation take place The final location of the posts and guardrail in relation to the wall should be positioned according to the design from the engineer, as should any additional reinforcement required in the design. Install any sleeves according to the wall plan. Sleeves should be at least 1 inch larger than the posts to allow for concrete and grouting. Walls should not be completed and sleeves then 'punched' through the already installed backfill and reinforcement layers after construction is complete This may result in damage to the reinforcement grids and lead to subsequent failure of the wall. Sleeves should be installed and held in place before any reinforcement the sleeve passes through is positioned, with the watt blocks, drainage material and backfill being installed and constructed in accordance with the instructions found elsewhere on anchordiamond com Carefully cut the reinforcement cross straps to allow the reinforcement to fit around the sleeve without distortion or additional tension being introduced to the grid when in its final location. Ensure the reinforcement grid is installed in accordance with the instructions found elsewhere on an chordiamond.com. Grout the guardrail posts into each sleeve after the wall is built FENCES The specific dimensions of the fence and fence post spacing are required to accurately determine the placement of the sleeves, Provide at least 1 inch clearance between the inside of the sleeve and the outside of the post to allow for mortar and grout. Install the sleeves according to the watt plan during the construction of the wall If the fence is at Least 3 feet back from the watt face, generally no additional reinforcement is required If the fence is installed within 3 feet from the face of the watt, there may be some load transferred to the wall from wind, snow or pedestrians Additional reinforcement around the fence sleeves may be needed Consult a suitably qualified engineer before installation takes place. Walls should not be completed and sleeves then 'punched' through the already installed backfill and reinforcement layers after construction is complete This may result in damage to the reinforcement grids and lead to subsequent failure of the wall. Carefully cut the reinforcement cross straps to allow the reinforcement to fit around the sleeve without distortion or additional tension being introduced to the grid when in its final location Grout the fence post into the sleeve after the wall is built 'Ni ANCHOR 0 DIAMOND TERRACES WATER APPLICATIONS @11DOANCHOR DIAMOND INDEPENDENT TERRACED WALLS Far each wall to be independent clothiers, they must be built using a 2.1 ratio. The upper wall must be built a distance away from the lower wall of at least twice the height of the lower wall In addition, the upper wall must also be equal to or less than the height of the lower wall. Exceptions to this general rule include weak soil conditions or where slopes exist above, below or between watt tocations For example, if the lower terrace is 3 feet 4 inches tall the distance to the upper terrace must be at least 6 feet 8 Inches, and the upper watt must not be higher than 3 feet 4 inches Proper dra wage is vital to maintaining stable, long-lasting terraced walls. Drainage pipe must be installed so that the water is directed around or under the lower wall (Never place the drainpipe outlet for the upper wall above or behind the lower wall.) DEPENDENT TERRACED WALLS When the distance between the lower and upper walls is less than twice the height of the lower watt, the walls become structurally dependent on each other. In this situation, it is important to take global stability ( the resistance to overall mass movement of the whole SRW system in a circular or sliding mode) into account, incorporating additional reinforcement -and longer layers -into the wall plan In addition, structurally dependent walls require even more excavation, back fi It and time For dependent walls, consult a qualified engineer i DIAMOND FRO'LOCK I BLOCK , 12' (MIN) OF FREE- DRAININGAGGREGATE CAP BLOCK — .. I I Other Leyera , VARIES—{ �--------- � x ! -__ O , z 2m Layer i _ REINFORCEMENT FINISHED LENGTH GRADE \` - 1el Layer) ! V _C'ODRAINTILE(EL-VARI_) 6' MINIMUM COMPACTED GRANULARAASE LEVELING PAD 6 2P With correct design and construction, Anchor® products can be successfully installed at the edge of water channels, river banks and drainage ditches. The final design of the wall is affected by various factors, including the movement and velocity of the adjacent water, erosion and scour, the direction of water travel to the wall, the risk of flooding, as well as the soil and ground conditions where the wall is being built A qualified engineer should always be consulted to determine the effect of water on the wall and to design a wall that takes all these factors into account Consult a qualified engineer before design, construction and installation take place, and follow the engineer's design Any reinforced -zone material should be made up of free draining materia BASE COURSE Place a filter fabric with extra length ( as specified by the engineer's design) in front of the wall The filter fabric will sit below the leveling pad, extend out into the reinforced zone and, after installation of the base course, up the front of the wa It. Install the leveling pad and the base course, the drainage aggregate and drainpipe. Wrap the fitter fabric up the face of the wait to the top of the base course Place soil fill in front of the wall and fully compact, trapping the fitter fabric against the front of the wall Install a second layer of fitter fabric to the front of the wall, with sufficient width to allow the fitter fabric to extend up the face of the wall to the depth of the layer of larger stones required to prevent scour along the base of the wall. Install a minimum of 3 inches of sand over the filter fabric, before installing the layer of larger stones. Use the layer of larger stones to trap the fitter fabric against the face of the watt NEXT COURSE Continue construction of the wall. A fitter fabric should be installed between the drainage aggregate and the reinforced -soil zone for the full height and length of the wall This prevents any clogging of the drainage fill by fines from the reinforced zone. ADDITIONAL COURSES Continue these steps until the wall is complete The final section of filter fabric should cover the drainage aggregate and run up aga cost the back of the top course of block -J renrr Exhibit "C" CITY OF FORT WORTH STORMWATER FACILITY OPERATION AND MAINTENANCE PLAN The only responsibility the City of Fort Worth has in the operation and maintenance of this Facility is inspection. General Maintenance Procedures The structural and functional integrity of the Facility shall be maintained at all times by removing and preventing drainage interference, obstructions, blockages, or other adverse effects into, through, or out of the system. Periodic silt removal shall occur when standing water conditions occur or the pond's storage volume is reduced by more than 10%. Silt shall be removed and the pondibasin returned to original lines and grades shown on the approved engineering plans. In addition, corrective measures are required any time a basin does not drain completely within 72 hours of cessation of inflow. NO STANDING WATER IS ALLOWED in basins designed for dry detention purposes. Accumulated litter, sediment, and debris shall be removed every 6 months or as necessary to maintain proper operation of the basin. Disposal shall be in accordance with federal, state and local regulations. Detention facilities shall be mowed monthly between the months of April and October or anytime vegetation exceeds 12-inches in height. To prevent debris from entering and clogging the downstream storm sewer system a wire mesh screen or similar screening device shall be installed over the outlet until final acceptance. 4. PREVENTIVE MAINTENANCE/INSPECTION Visual inspections of all components will be conducted every 6 months. A log shall be kept of maintenance actions, and inspections. The log should document the condition of the detention system's primary components, mowing, and silt, litter and debris removal dates. Document aeration of the basin bottoms and replanting to prevent the sealing of the basin bottom. Written maintenance and repair records shall be maintained by the party or parties signing the attached Agreement and shall be provided to the City upon request. STORMWATER FACILITY MAINTENANCE AGREEMENT 9 Rev. 03/01/2022 BN Exhibit "D" Stormwater Structural Maintenance CHECKLIST FREQUENT INSPECTION Mowing Remove Trash and debris Inspect irrigation system operation Remove grass clippings Violations Noted MINOR INSPECTION Condition of Pond Amount of silt in pond Amount of silt in flume Amount of ponded water Amount of wetland vegetation Location of Erosion Percent of vegetation Condition of trash guard Location of Erosion MAJOR INSPECTIONS Condition of Stormwater Quality Structure Type of Stormwater Quality Structure Structure type and Condition Condition of Rip -Rap Condition of filtration system REPAIRS REPAIRS DATE NOTES REQUIRED MADE STORMWATER FACILITY MAINTENANCE AGREEMENT 10 Rev. 03/01/2022 BN Berm or Embankment Settlement Location of erosion Evidence of Animals Evidence of Aquatic life Condition of Aeration Foundation STORMWATER FACILITY MAINTENANCE AGREEMENT 11 Rev. 03/01/2022 BN