Loading...
HomeMy WebLinkAboutContract 61762CSC No. 61762 FORT WORTHS VENDOR SERVICES AGREEMENT This VENDOR SERVICES AGREEMENT ("Agreement") is made and entered into by and between the CITY OF FORT WORTH ("City"), a Texas home -rule municipal corporation acting by and through its duly authorized Assistant City Manager, and ARMSTRONG FORENSIC LABORATORY, INC. ("Vendor"), a Texas corporation acting by and through its duly authorized representative, each individually referred to as a "party" and collectively referred to as the "parties." 1. Scope of Services. Vendor will provide lab analysis of various controlled substances, metals testing, gasoline fingerprinting, THC gummies, vapes, Total Suspended Solids, Biochemical Oxygen Demand, Chemical Oxygen Demand, and TPH — Total Petroleum Hydrocarbons ("Services) for the Police Department Forensics Laboratory ("Crime Lab") and the Water Department ("Water Department'), which are set forth in more detail in Exhibit "A" ("Scope of Services"), attached hereto and incorporated herein for all purposes. 2. Term. The initial term of this Agreement is for a period beginning on September 1, 2024 ("Effective Date"), and terminating on August 31, 2025 ("Termination Date"), unless terminated earlier in accordance with this Agreement. City will have the option, in its sole discretion, to renew this Agreement under the same terms and conditions for up to four (4) one-year renewal periods (each a "Renewal Term"). 3. Compensation. 3.1 City shall pay Vendor in accordance with the fee schedule of Vendor personnel who perform services under this Agreement, and in accordance with the provisions of this Agreement and Exhibit `B" ("Fee Schedule"), attached hereto and incorporated herein for all purposes. Total compensation under this Agreement will not exceed fifty thousand dollars and zero cents ($50,000.00) annually. 3.2 City will pay Vendor in accordance with the Prompt Payment Act (Chapter 2251 of the Texas Government Code) and the provisions of this Agreement, including Exhibit `B" ("Fee Schedule"), which is attached hereto and incorporated herein for all purposes. 3.3 Vendor will not perform any additional services or bill for expenses incurred for City not specified by this Agreement unless City requests and approves in writing the additional costs for such services. City will not be liable for any additional expenses of Vendor not specified by this Agreement unless City first approves such expenses in writing. OFFICIAL RECORD CITY SECRETARY FT. WORTH, TX Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 1 of 63 4. Termination. 4.1. Written Notice. City or Vendor may terminate this Agreement at any time and for any reason by providing the other party with at least 30 days' written notice of termination. 4.2 Non -Appropriation of Funds. In the event no funds or insufficient funds are appropriated by City in any fiscal period for any payments due hereunder, City will notify Vendor of such occurrence and this Agreement will terminate on the last day of the fiscal period for which appropriations were received without penalty or expense to City of any kind whatsoever, except as to the portions of the payments herein agreed upon for which funds have been appropriated. 4.3 Duties and Obligations of the Parties. In the event that this Agreement is terminated prior to the Termination Date, City will pay Vendor for services actually rendered up to the effective date of termination, and Vendor will continue to provide City with services requested by City and in accordance with this Agreement up to the effective date of termination. Upon termination of this Agreement for any reason, Vendor will provide City with copies of all completed or partially completed documents prepared under this Agreement. In the event Vendor has received access to City Information or data as a requirement to perform services hereunder, Vendor will return all City -provided data to City in a machine-readable format or other format deemed acceptable to City. 5. Disclosure of Conflicts and Confidential Information. 5.1 Disclosure of Conflicts. Vendor hereby warrants to City that Vendor has made full disclosure in writing of any existing or potential conflicts of interest related to Vendor's services under this Agreement. In the event that any conflicts of interest arise after the Effective Date of this Agreement, Vendor hereby agrees immediately to make full disclosure to City in writing. 5.2 Confidential Information. Vendor, for itself and its officers, agents, and employees, agrees that it will treat all information provided to it by City ("City Information") as confidential and will not disclose any such information to a third party without the prior written approval of City. 5.3 Public Information Act. City is a government entity under the laws of the State of Texas, and all documents held or maintained for City are subject to disclosure under the Texas Public Information Act. In the event there is a request for information marked Confidential or Proprietary, City will promptly notify Vendor. It will be the responsibility of Vendor to submit reasons objecting to disclosure to the Texas Attorney General. A determination on whether such reasons are sufficient will not be decided by City, but by the Office of the Attorney General of the State of Texas or by a court of competent jurisdiction. 5.4 Unauthorized Access. Vendor must store and maintain City Information in a secure manner and will not allow unauthorized users to access, modify, delete, or otherwise corrupt City Information in any way. Vendor must notify City immediately if the security or integrity of any City Information has been compromised or is believed to have been compromised, in which event, Vendor will, in good faith, use all commercially reasonable efforts to cooperate with City in identifying what information has been accessed by unauthorized means and will fully cooperate with City to protect such City Information from further unauthorized disclosure. Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 2 of 63 6. Right to Audit. Vendor agrees that City will, until the expiration of three (3) years after final payment under this Agreement or the final conclusion of any audit commenced during the said three years, have access to and the right to examine at reasonable times any directly pertinent books, documents, papers, and records, including, but not limited to, all electronic records of Vendor involving transactions relating to this Agreement at no additional cost to City. Vendor agrees that City will have access during normal working hours to all necessary Vendor facilities and will be provided adequate and appropriate work space in order to conduct audits in compliance with the provisions of this section. City will give Vendor reasonable advance notice of intended audits. 7. Independent Contractor. It is expressly understood and agreed that Vendor will operate as an independent contractor as to all rights and privileges and work performed under this Agreement and not as an agent, representative, or employee of City. Subject to and in accordance with the conditions and provisions of this Agreement, Vendor will have the exclusive right to control the details of its operations and activities and shall be solely responsible for the acts and omissions of its officers, agents, servants, employees, vendors, and subcontractors. Vendor acknowledges that the doctrine of respondeat superior will not apply as between City, its officers, agents, servants, and employees, and Vendor and Vendor's officers, agents, employees, servants, contractors, and subcontractors. Vendor further agrees that nothing herein will be construed as the creation of a partnership or joint enterprise between City and Vendor. It is further understood that City will in no way be considered a co -employer or a joint employer of Vendor or any of its officers, agents, servants, employees, contractors, or subcontractors. Neither Vendor, nor any officers, agents, servants, employees, contractors, or subcontractors of Vendor, will be entitled to any employment benefits from City. Vendor will be responsible and liable for any and all payment and reporting of taxes on behalf of itself and any of its officers, agents, servants, employees, or contractors. 8. Liability and Indemnification. 8.1 LIABILITY - VENDOR WILL BE LIABLE AND RESPONSIBLE FOR ANY AND ALL PROPERTY LOSS, PROPERTY DAMAGE, AND PERSONAL INJURY, INCLUDING, BUT NOT LIMITED TO, DEATH, TO ANY AND ALL PERSONS, OF ANY KIND OR CHARACTER, WHETHER REAL OR ASSERTED, TO THE EXTENT CAUSED BY THE NEGLIGENT ACT(S) OR OMISSION(S), MALFEASANCE, OR INTENTIONAL MISCONDUCT OF VENDOR, ITS OFFICERS, REPRESENTATIVES, AGENTS, SERVANTS, EMPLOYEES, CONTRACTORS, OR SUBCONTRACTORS. 8.2 GENERAL INDEMNIFICATION - VENDOR HEREBY COVENANTS AND AGREES TO INDEMNIFY, HOLD HARMLESS, AND DEFEND CITY, ITS OFFICERS, AGENTS, REPRESENTATIVES, SERVANTS, AND EMPLOYEES, FROM AND AGAINST ANY AND ALL CLAIMS OR LAWSUITS OF ANY KIND OR CHARACTER, WHETHER REAL OR ASSERTED, FOR PROPERTY DAMAGE OR LOSS (INCLUDING ALLEGED DAMAGE OR LOSS TO VENDOR'S BUSINESS AND ANY RESULTING LOST PROFITS) AND PERSONAL INJURY, INCLUDING, BUT NOT LIMITED TO, DEATH, TO ANYAND ALL PERSONS, ARISING OUT OF OR IN CONNECTION WITH THIS AGREEMENT, TO THE EXTENT CAUSED BY THE NEGLIGENT ACTS OR OMISSIONS, MALFEASANCE, OR INTENTIONAL MISCONDUCT OF VENDOR, ITS OFFICERS, AGENTS, REPREENTATIVES, SERVANTS, EMPLOYEES, CONTRACTORS, OR SUBCONTRACTORS. Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 3 of 63 8.3 INTELLECTUAL PROPERTY INDEMNIFICATION - VENDOR AGREES TO DEFEND, SETTLE, OR PAY, AT ITS OWN COST AND EXPENSE, ANY CLAIM OR ACTION AGAINST CITY FOR INFRINGEMENT OF ANY PATENT, COPYRIGHT, TRADEMARK, TRADE SECRET, OR SIMILAR PROPERTY RIGHT ARISING FROM CITY'S USE OF SOFTWARE OR DOCUMENTATION IN ACCORDANCE WITH THIS AGREEMENT, IT BEING UNDERSTOOD THAT THIS AGREEMENT TO DEFEND, SETTLE, OR PAY WILL NOT APPLYIF CITYMODIFIES OR MISUSES THE SOFTWARE AND/OR DOCUMENTATION. SO LONG AS VENDOR BEARS THE COST AND EXPENSE OF PAYMENT FOR CLAIMS OR ACTIONS AGAINST CITY PURSUANT TO THIS SECTION, VENDOR WILL HAVE THE RIGHT TO CONDUCT THE DEFENSE OF ANY SUCH CLAIM OR ACTION AND ALL NEGOTIATIONS FOR ITS SETTLEMENT OR COMPROMISE AND TO SETTLE OR COMPROMISE ANY SUCH CLAIM, HOWEVER, CITY WILL HAVE THE RIGHT TO FULLY PARTICIPATE IN ANY AND ALL SUCH SETTLEMENT, NEGOTIATIONS, OR LAWSUIT AS NECESSARY TO PROTECT CITY'S INTERESTS, AND CITY AGREES TO COOPERATE WITH VENDOR IN DOING SO. IN THE EVENT CITY, FOR WHATEVER REASON, ASSUMES THE RESPONSIBILITY FOR PAYMENT OF COSTS AND EXPENSES FOR ANY CLAIM OR ACTION BROUGHT AGAINST CITY FOR INFRINGEMENT ARISING UNDER THIS AGREEMENT, CITY WILL HAVE THE SOLE RIGHT TO CONDUCT THE DEFENSE OF ANY SUCH CLAIM OR ACTIONAND ALL NEGOTIATIONS FOR ITS SETTLEMENT OR COMPROMISE AND TO SETTLE OR COMPROMISE ANY SUCH CLAIM, HOWEVER, VENDOR WILL FULLY PARTICIPATE AND COOPERATE WITH CITY IN DEFENSE OF SUCH CLAIM OR ACTION. CITYAGREES TO GIVE VENDOR TIMELY WRITTENNOTICE OFANYSUCH CLAIM OR ACTION, WITH COPIES OF ALL PAPERS CITYMAY RECEIVE RELATING THERETO. NOTWITHSTANDING THE FOREGOING, CITY'S ASSUMPTION OF PAYMENT OF COSTS OR EXPENSES WILL NOT ELIMINATE VENDOR'S DUTY TO INDEMNIFY CITY UNDER THIS AGREEMENT. IF THE SOFTWARE AND/OR DOCUMENTATION OR ANY PART THEREOF IS HELD TO INFRINGE AND THE USE THEREOF IS ENJOINED OR RESTRAINED OR, IF AS A RESULT OF A SETTLEMENT OR COMPROMISE, SUCH USE IS MA TERIALL Y AD VERSEL Y RESTRICTED, VENDOR WILL, AT ITS OWN EXPENSE. (A) PROCURE FOR CITY THE RIGHT TO CONTINUE TO USE THE SOFTWARE AND/OR DOCUMENTATION, OR (B) MODIFY THE SOFTWARE AND/OR DOCUMENTATION TO MAKE IT NON -INFRINGING, PROVIDED THAT SUCH MODIFICATION DOES NOT MATERIALLY ADVERSELY AFFECT CITY'S A UTHORMED USE OF THE SOFTWARE AND/OR DOCUMENTATION, OR (C) REPLACE THE SOFTWARE AND DOCUMENTATION WITHEQUALLY SUITABLE, COMPATIBLE, AND FUNCTIONALLY EQUIVALENT NON -INFRINGING SOFTWARE AND DOCUMENTATIONAT NO ADDITIONAL CHARGE TO CITY; OR (D) IF NONE OF THE FOREGOING ALTERNATIVES IS REASONABLY AVAILABLE TO VENDOR, TERMINATE THIS AGREEMENT AND REFUND ALL AMOUNTS PAID TO VENDOR BY CITY, SUBSEQUENT TO WHICH TERMINATION CITY MAY SEEK ANY AND ALL REMEDIES AVAILABLE TO CITY UNDER LAW. 9. Assignment and Subcontracting. 9.1 Assignment. Vendor will not assign or subcontract any of its duties, obligations, or rights under this Agreement without the prior written consent of City. If City grants consent to an assignment, the assignee will execute a written agreement with City and Vendor under which the assignee agrees to be bound by the duties and obligations of Vendor under this Agreement. Vendor and assignee will be jointly liable for all obligations of Vendor under this Agreement prior to the effective date of the assignment. Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 4 of 63 9.2 Subcontract. If City grants consent to a subcontract, the subcontractor will execute a written agreement with Vendor referencing this Agreement under which subcontractor agrees to be bound by the duties and obligations of Vendor under this Agreement as such duties and obligations may apply. Vendor must provide City with a fully executed copy of any such subcontract. 10. Insurance. Vendor must provide City with certificate(s) of insurance documenting policies of the following types and minimum coverage limits that are to be in effect prior to commencement of any Services pursuant to this Agreement: 10.1 Coverage and Limits (a) Commercial General Liability: $1,000,000 - Each Occurrence $2,000,000 - Aggregate (b) Automobile Liability: $1,000,000 - Each occurrence on a combined single limit basis Coverage will be on any vehicle used by Vendor, or its employees, agents, or representatives in the course of providing Services under this Agreement. "Any vehicle" will be any vehicle owned, hired, and non -owned. (c) Workers' Compensation: Statutory limits according to the Texas Workers' Compensation Act or any other state workers' compensation laws where the Services are being performed Employers' liability $100,000 - Bodily Injury by accident; each accident/occurrence $100,000 - Bodily Injury by disease; each employee $500,000 - Bodily Injury by disease; policy limit (d) Professional Liability (Errors & Omissions): XJ Applicable [01 N/A $1,000,000 - Each Claim Limit $1,000,000 - Aggregate Limit Professional Liability coverage may be provided through an endorsement to the Commercial General Liability (CGL) policy, or a separate policy specific to Professional E&O. Either is acceptable if coverage meets all other requirements. Coverage must be claims -made, and maintained for the duration of the contractual agreement and for two (2) years following completion of services provided. An annual certificate of insurance must be submitted to City to evidence coverage. 10.2 General Requirements Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 5 of 63 (a) The commercial general liability and automobile liability policies must name City as an additional insured thereon, as its interests may appear. The term City includes its employees, officers, officials, agents, and volunteers with respect to the contracted services. (b) The workers' compensation policy must include a Waiver of Subrogation (Right of Recovery) in favor of City. (c) A minimum of thirty (30) days' notice of cancellation or reduction in limits of coverage must be provided to City. At least ten (10) days' notice will be acceptable in the event of cancellation due to non-payment of premium. Notice must be sent to the Risk Manager, City of Fort Worth, 200 Texas Street, Fort Worth, Texas 76102, with copies to the Fort Worth City Attorney at the address below. (d) The insurers for all policies must be licensed and/or approved to do business in the State of Texas. All insurers must have a minimum rating of A- VII in the current A.M. Best Key Rating Guide, or have reasonably equivalent financial strength and solvency to the satisfaction of Risk Management. If the rating is below that required, written approval of Risk Management is required. (e) Any failure on the part of City to request required insurance documentation will not constitute a waiver of the insurance requirement. (f) Certificates of Insurance evidencing that Vendor has obtained all required insurance will be delivered to the City prior to Vendor proceeding with any work pursuant to this Agreement. 11. ComDliance with Laws, Ordinances, Rules, and Reiulations. Vendor agrees that in the performance of its obligations hereunder, it will comply with all applicable federal, state, and local laws, ordinances, rules, and regulations and that any work it produces in connection with this Agreement will also comply with all applicable federal, state, and local laws, ordinances, rules, and regulations. If City notifies Vendor of any violation of such laws, ordinances, rules, or regulations, Vendor must immediately desist from and correct the violation. 12. Non -Discrimination Covenant. Vendor, for itself, its personal representatives, assigns, contractors, subcontractors, and successors in interest, as part of the consideration herein, agrees that in the performance of Vendor's duties and obligations hereunder, it will not discriminate in the treatment or employment of any individual or group of individuals on any basis prohibited by law. IF ANY CLAIM ARISES FROM AN ALLEGED VIOLATION OF THIS NON-DISCRIMINATION COVENANT BY VENDOR, ITS PERSONAL REPRESENTATIVES, ASSIGNS, CONTRACTORS, SUBCONTRACTORS, OR SUCCESSORS IN INTEREST, VENDOR AGREES TO ASSUME SUCH LIABILITY AND TO INDEMNIFY AND DEFEND CITY AND HOLD CITY HARMLESS FROM SUCH CLAIM. 13. Notices. Notices required pursuant to the provisions of this Agreement will be conclusively determined to have been delivered when (1) hand -delivered to the other party, its agents, employees, servants or representatives, or (2) delivered by facsimile with electronic confirmation of the transmission, or (3) received by the other party by United States Mail, registered, return receipt requested, addressed as follows: Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 6 of 63 To CITY: To VENDOR: City of Fort Worth Armstrong Forensic Laboratory, Inc. Attn: Assistant City Manager Benjamin Armstrong, President 100 Fort Worth Trail (formerly Energy Way) 330 Loch'n Green Trail Fort Worth, TX 76102 Arlington, TX 76012 Facsimile: (817) 392-8654 (817) 275-2691 Office (817 275-1883 (Fax) With a copy to Fort Worth City Attorney's Office Ben@AFLab.com at same address 14. Solicitation of Emplovees. Neither City nor Vendor will, during the term of this Agreement and additionally for a period of one year after its termination, solicit for employment or employ, whether as employee or independent contractor, any person who is or has been employed by the other during the term of this Agreement, without the prior written consent of the other party. Notwithstanding the foregoing, this provision will not apply to an employee of either party who responds to a general solicitation or advertisement of employment by either party. 15. Governmental Powers. It is understood and agreed that, by execution of this Agreement, City does not waive or surrender any of its governmental powers or immunities. 16. No Waiver. The failure of City or Vendor to insist upon the performance of any term or provision of this Agreement or to exercise any right granted herein does not constitute a waiver of City's or Vendor's respective right to insist upon appropriate performance or to assert any such right on any future occasion. 17. Governing Law / Venue. This Agreement will be construed in accordance with the laws of the State of Texas. If any action, whether real or asserted, at law or in equity, is brought pursuant to this Agreement, venue for such action will lie in state courts located in Tarrant County, Texas, or the United States District Court for the Northern District of Texas, Fort Worth Division. 18. Severability. If any provision of this Agreement is held to be invalid, illegal, or unenforceable, the validity, legality, and enforceability of the remaining provisions will not in any way be affected or impaired. 19. Force Maieure. City and Vendor will exercise their best efforts to meet their respective duties and obligations as set forth in this Agreement, but will not be held liable for any delay or omission in performance due to force majeure or other causes beyond their reasonable control, including, but not limited to, compliance with any law, ordinance, or regulation; acts of God; acts of the public enemy; fires; strikes; lockouts; natural disasters; wars; riots; epidemics or pandemics; government action or inaction; orders of government; material or labor restrictions by any governmental authority; transportation problems; restraints or prohibitions by any court, board, department, commission, or agency of the United States or of any state; civil disturbances; other national or regional emergencies; or any other similar cause not enumerated herein but which is beyond the reasonable control of the Party whose performance is affected (collectively, "Force Majeure Event"). The performance of any such obligation is suspended during the period of, and only to the extent of, such prevention or hindrance, provided the affected Party provides notice of the Force Majeure Event and an explanation as to how it prevents or hinders the Party's performance as soon as reasonably possible after the occurrence of the Force Majeure Event, with the reasonableness of such notice to be determined by the City in its sole discretion. The notice required by this section must be addressed and delivered in accordance with the notice section of this Agreement. Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 7 of 63 20. Headings Not Controlling. Headings and titles used in this Agreement are for reference purposes only, will not be deemed a part of this Agreement, and are not intended to define or limit the scope of any provision of this Agreement. 21. Review of Counsel. The parties acknowledge that each party and its counsel have had the opportunity to review and revise this Agreement and that the normal rule of contract construction to the effect that any ambiguities are to be resolved against the drafting party will not be employed in the interpretation of this Agreement. 22. Amendments / Modifications / Extensions. No amendment, modification, or extension of this Agreement will be binding upon a party hereto unless set forth in a written instrument executed by an authorized representative of each party. 23. Entirety of Agreement. This Agreement contains the entire understanding and agreement between City and Vendor, their assigns, and successors in interest as to the matters contained herein. Any prior or contemporaneous oral or written agreement is hereby declared null and void to the extent in conflict with any provision of this Agreement. 24. Counterparts. This Agreement may be executed in one or more counterparts, and each counterpart will, for all purposes, be deemed an original, but all such counterparts will together constitute one and the same instrument. 25. Warranty of Services. Vendor warrants that its services will be of a high quality and conform to generally prevailing industry standards. City must give written notice of any breach of this warranty within thirty (30) days from the date that the services are completed. In such event, at Vendor's option, Vendor will either (a) use commercially reasonable efforts to re -perform the services in a manner that conforms with the warranty, or (b) refund the fees paid by City to Vendor for the nonconforming services. 26. Immigration and Nationalitv Act. Vendor must verify the identity and employment eligibility of its employees who perform work under this Agreement, including completing the Employment Eligibility Verification Form (I-9). Upon request by City, Vendor will provide City with copies of all I-9 forms and supporting eligibility documentation for each employee who performs work under this Agreement. Vendor must adhere to all federal and state laws and establish appropriate procedures and controls so that no services will be performed by any Vendor employee who is not legally eligible to perform such services. VENDOR WILL INDEMNIFY CITY AND HOLD CITY HARMLESS FROM ANY PENALTIES, LIABILITIES, OR LOSSES DUE TO VIOLATIONS OF THIS PARAGRAPH BY VENDOR, VENDOR'S EMPLOYEES, CONTRACTORS, SUBCONTRACTORS, OR AGENTS. City, upon written notice to Vendor, will have the right to immediately terminate this Agreement for violations of this provision by Vendor. 27. Ownership of Work Product. City will be the sole and exclusive owner of all reports, work papers, procedures, guides, and documentation created, published, displayed, or produced in conjunction with the services provided under this Agreement (collectively, "Work Product"). Further, City will be the sole and exclusive owner of all copyright, patent, trademark, trade secret, and other proprietary rights in and to the Work Product. Ownership of the Work Product will inure to the benefit of City from the date of conception, creation, or fixation of the Work Product in a tangible medium of expression (whichever occurs first). Each copyrightable aspect of the Work Product will be considered a "work -made - for -hire" within the meaning of the Copyright Act of 1976, as amended. If and to the extent such Work Product, or any part thereof, is not considered a "work -made -for -hire" within the meaning of the Copyright Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 8 of 63 Act of 1976, as amended, Vendor hereby expressly assigns to City all exclusive right, title, and interest in and to the Work Product, and all copies thereof, and in and to the copyright, patent, trademark, trade secret, and all other proprietary rights therein, that City may have or obtain, without further consideration, free from any claim, lien for balance due, or rights of retention thereto. 28. Signature Authoritv. The person signing this Agreement hereby warrants that they have the legal authority to execute this Agreement on behalf of the respective party, and that such binding authority has been granted by proper order, resolution, ordinance, or other authorization of the entity. This Agreement, and any amendment hereto, may be executed by any authorized representative of Vendor. Each party is fully entitled to rely on these warranties and representations in entering into this Agreement or any amendment hereto. 29. Change in Companv Name or Ownership. Vendor must notify City's Purchasing Manager in writing of a company name, ownership, or address change for the purpose of maintaining updated City records. The president of Vendor or authorized official must sign the letter. A letter indicating changes in a company name or ownership must be accompanied with supporting legal documentation such as an updated W-9, documents filed with the state indicating such change, copy of the board of director's resolution approving the action, or an executed merger or acquisition agreement. Failure to provide the specified documentation may adversely impact invoice payments. 30. No Bovcott of Israel. If Vendor has fewer than 10 employees or this Agreement is for less than $100,000, this section does not apply. Vendor acknowledges that in accordance with Chapter 2271 of the Texas Government Code, the City is prohibited from entering into a contract with a company for goods or services unless the contract contains a written verification from the company that it: (1) does not boycott Israel; and (2) will not boycott Israel during the term of the contract. The terms "boycott Israel" and "company" have the meanings ascribed to those terms in Section 2271 of the Texas Government Code. To the extent that Chapter 2271 of the Government Code is applicable to this Agreement, by signing this Agreement Vendor certifies that Vendor's signature provides written verification to the City that Vendor: (1) does not boycott Israel; and (2) will not boycott Israel during the term of the Agreement. 31. Prohibition on Bovcotting Enemv Companies. If Vendor has fewer than 10 employees or this Agreement is for less than $100,000, this section does not apply. Vendor acknowledges that in accordance with Chapter 2276 of the Texas Government Code, the City is prohibited from entering into a contract for goods or services unless the contract contains a written verification from the Vendor that it: (1) does not boycott energy companies; and (2) will not boycott energy companies during the term of this Agreement. The terms "boycott energy company" and "company" have the meanings ascribed to those terms in Section 2276 of the Texas Government Code. To the extent that Chapter 2276 of the Government Code is applicable to this Agreement, by signing this Agreement Vendor certifies that Vendor's signature provides written verification to the City that Vendor: (1) does not boycott energy companies; and (2) will not boycott energy companies during the term of this Agreement. 32. Prohibition on Discrimination Against Firearm and Ammunition Industries. If Vendor has fewer than 10 employees or this Agreement is for less than $100,000, this section does not apply. Vendor acknowledges that in accordance with Chapter 2274 of the Texas Government Code, the City is prohibited from entering into a contract for goods or services unless the contract contains a written verification from the Vendor that it: (1) does not have a practice, policy, guidance, or directive that discriminates against a firearm entity or firearm trade association; and (2) will not discriminate during the term of the contract against a firearm entity or firearm trade association. The terms "discriminate," "firearm entity," and "firearm trade association" have the meanings ascribed to those terms in Section 2274 of the Texas Government Code. To the extent that Chapter 2274 of the Government Code is applicable to this Agreement, by signing this Agreement Vendor certifies that Vendor's signature provides written Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 9 of 63 verification to the City that Vendor: (1) does not have a practice, policy, guidance, or directive that discriminates against a firearm entity or firearm trade association; and (2) will not discriminate against a firearm entity or firearm trade association during the term of this Agreement. 33. Electronic Sienatures. This Agreement may be executed by electronic signature, which will be considered as an original signature for all purposes and have the same force and effect as an original signature. For these purposes, "electronic signature" means electronically scanned and transmitted versions (e.g. via pdf file, email, or facsimile transmission) of an original signature, or signatures electronically inserted via software such as Adobe Sign. IN WITNESS WHEREOF, the parties hereto have executed this Agreement in multiples. CITY OF FORT WORTH: By: WXY�� William Johnson (4126, 202414:48 CDT) Name: William Johnson Title: Assistant City Manager Date: Jul 26, 2024 ARMSTRONG FORENSIC LABORATORY, INC.: G, By: Name: e=mirmstrong Title: Pr Date:--1``��2,v�a� J FOR CITY OF FORT WORTH INTERNAL PROCESSES: Approval Recommended: By: RoberNlldr l26, 202412:34 CDT) Name: Robert A. Alldredge, Jr. Title: Executive Assistant Chief Attest: V By: Name: Jannette S. Goodall Title: City Secretary Contract Authorization: M&C: None Required Date M&C Approved: N/A Form 1295: N/A na �01.ORT 9d0 O°^° quo .IP Q°�a nezpsddP Contract Compliance Manager: By signing I acknowledge that I am the person responsible for the monitoring and administration of this contract, including ensuring all performance and reporting requirements. By. XgQl� C lam✓ Name: Loraine Coleman Title: Administrative Services Manager Approved as to Form and Legality: By: A P/,ems Name: Andrea Phillips Title: Assistant City Attorney OFFICIAL RECORD CITY SECRETARY FT. WORTH, TX Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 10 of 63 EXHIBIT A SCOPE OF SERVICES Armstrong Forensic Laboratory, Inc. OVERVIEW Armstrong's project specific scope of service under Ibis contract includes: • Project Specific COC (Chain of Custody) as required; • Evidence transport, as requested; • Evidence receipt and conf innation of information; • Photographic documentation ofcontrolled substance evidence upon receipt at laboratory; • t.xamination of evidence indicated for analysis; • Identification and selection ofsamples and sub -samples; • initial and final weight ofevidence, as appropriate; Appropriate and necessary analyses for controlled substance is based on characteristics of evidence, including but not limited to, • FTIR (Fourier -transform infrared spectroscopy); • Qualitative GC/MS (Gas chromatography —mass spectrometry); ■ Microscopical i=xatnination(s); • Spot Test(s). Analyses will conform to ASTM (American Society ror Testing and Materiels) or SWGDrug (Scientific Working Group for Analysis of Seized Drugs) O standards and guidelines as appropriate. Blood alcohol concentration is performed by GC-FID (Gas Chromatography- Flamc Ionization Detector) on a specialized piece ofequipment, an Agilent 6890 Series GC Flex AutoSampler; • Court -ready Laboratory Analytical Report; • Affidavit of Analysis as requested; and Secure, temporary evidence storage pending return shipment or transport Armstrong will perform the appropriate testing as described in the Scientific Working Group for Analysis of Seized Drugs (SWGDrug) Recommendations for Code of Professional Practice; Education and Training; Methods of Analysis; and Quality Assurance and/or ASTM Standard Math odslPractices. Unless otherwise noted, Armstrong will analyze only those items of evidence that are not considered extraneous items or paraphernalia. Only the physical material (solid or liquid) that would comprise the controlled substance will be analyzed. Unless otherwise allowed, sub -samples will be established in accordance with standard operating procedures. For bulk submissions that exceed thirty (30) individual units, Armstrong will release final laboratory reports in smaller groups as case riles are completed. That is, Armstrong will not hold reports for individual arresi cases pending completion of other laboratory work. Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 11 of 63 EVIDENCE 12F:V1E;1Y AND CONFIRMATION OF CASE INFORMATION Upon formal evidence receipt, the evidence is placed in the custody of a qualified ANAB (ANSI Naetional Accreditation Board; ANSI- Aniurican National Standards Institute) Analyst for initial processing prior to analysis. The evidence and related administrative documentation are again compared against the COC to verify all inforniolion, Where discrepancies between the information (physical evidence, evidence labeling, a-nd the COC) are identified the fort Worth PD will be contacted for resolution. Any changes made should he initialed and dated by the fort Worth PD and a corrected COC resubmitted to Armstrong. Armstrong's SOP related to Forensic Recovery (FR) case work, such as evidence submitted by the Fort Worth PD, require Ihat the evidence and all related information be handled based on the presumption that the information and data generated by the laboratory will he presented in court- Givcn the variability of the projects that may be subrinaed for Forensic Recovery, the handling of the evidence upon check -in must be considered on a case -by -case basis and must always maintain the integrity of the evidence submitted. Many of these samplers may require special examination, photographic documentation, and/or individual analytical assignment. After the submitted documentation (including the COC) is examined for completeness and a case file number is assigned, these samples are moved to a separate, secured evidence area until processing is begun, REPORT FORMAT AND AFFIDAVIT OF ANALYSIS Armstrong's Forensic Recovery Rcpurts are generated by the consulting staff under the direction of the Vice President of Services and are processed under the direction of the office Manager. Forensic Recovery Reports are issued for forensic case work designated as case type FR. In accordance with Armstrong's SOPS and ANAB requirements, the Consultatit(s) (ANAB Technical Reviewer/Analysts) responsible for the Case File will oversee report creation and sub nisslon. The Consultant ntay conduct, participate in, observe or supervise any tests, or will complete and document a review of all test documentation prior to preparing the final report. The responsible Consultant will document the review by initialing and dating each page of the data reviewed or a Document Review Cover Sheet identifying the data produced and reviewed that forms the basis of the conclusion(s) reached. Any opinions and interpretations included in the report will be clearly identified and the basis upon which those opinions and intcrpretatio+ts are made will he documented. If no definitive conclusions can be reached, the rcason(s) will be documented. The final report will contain the following information, at a mininttun: • Date the report is issued; Name, address, and phone number of the Laboratory; Name and address ofthe Client; • Name of Evidence Submitte Name of all parties receiving a copy or the report; • Page number and total number of pages ofthe report on each page; • Naine, title, and signature ofthe Analyst and/or Technical Reviewer; • Unique Laboratory Case File identification number on every page; • Description and identification of the smnpics and dale(s) received by the laboratory, including The laboratory's unique identifier; • Identification ofthe test method(s), the sample results, and conclusions; • The condition/acceptability ofthe samples; • Identification of the test method, analytical results, and reporting limit (if results are quantitated): Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 12 of 63 • Where relevant, a statement io the effect that the results relate only to the items tested; and • Name, title, and signature ofsignotorics accepting technical responsibility for tlic Report and of the analysis, The 'rechnical Reviewer is considered the Primary Signatory and the Analyst is the Second Signatory. In addition, where necessary for the interpretation ofthe analytical results, the report will include: • Date of analysis, • Deviations from, additions to, or exclusions from the test method, and information on specific test conditions, such as environmental conditions; • A statement of contpliancehton-compliance with requirements and/or specifications; • If applicable, a statement on the estimated uncertainty of measurement, if relevant to the validity or application of the test results, when requested by the Client, or when the uncertainty affects compliance to a specification limit; • Where appropriate and needed, opinions and interpretations; and • Additional information required by (lie analytical method or by the Client. if provided by the Client, and necessary for the interpretation of the test results, the report will include the following: • Date or sample collection; • An unambiguous identification of the substance, material or product sampled (including manufacturer, model or type designation, and serial number); • The sample location, including diagrams, sketches or photographs; • A reference to the sampling plans and sampling procedures used; and • Standards or specifications for the sampling method or procedure and deviations, additions or exclusions from the standards or specifications. All laboratory reports are stored electronically and the final report is printed on letterhead paper. Only one original is generated unless otherwise requested by the Fort Worth PD. The Office Manager, Vice President of Services, President, or designated qualified office personnel will review all Forensic Recovery Reports as the Administrative Reviewer. All signatories will have reviewed the Final report prior to signing in blue ink. Final reports issued to the Client via electronic delivery methods (email, facsimile, cic.) and/or mailed by U.S. Postal Service are considered final reports. If a determination is made that a report that has been issued in the U.S. Postal Service should be modified or amended, it will only be reissued with a notation at the top of the report as "Amended There will be an "Amended Report Tracking" table inserted at the end of the report and before the signature block noting the specifics related to any revision. To the extent possible, ali signatures included on the original report will be included with the amended report. Armstrong shall, where standard report format does not already, incorporate any requirements and recommendations for Final Reports as required, which may include: • Title: Name of lab performing analysis; • Date received by analyzing lab; Defendant(s) Name; • Date of Offense; • Offense Number; • Findings: namc(s) of controlled substance identified as listed in the Texas Controlled Substance Act; Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 13 of 63 • Net weight ofsample; and • Name of Analyst. An Affidavit of Analysis is available for each case file upon request. Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 14 of 63 Armstromy, Forensic Laboratory, Inc. 330 LocHn Green Trail Arhngton, Texas 76012-3458 917-275-2691 Fax: 817-275-1893 Peggy DeNovellis FWPD-Crime Lab RE: Full Force Letter Andrew T. Armstrong, PhD Marion K. Armstrong, MSPH, MBA, CIH Kelly L. Wonters, PhD Karen M. Deiss, BS Armstrong Forensic Laboratory has been the premier Fire Debris Testing laboratory since 1981, in 2019 Texas changed the laws regarding delta 9 THC and CBD products. We were the first laboratory in Texas, and one of the only private laboratories doing Texas Forensic Science Commission licensed testing suitable for courtroom presentation. We currently have done work in more than 80 counties in Texas and for numerous other states across the USA. While THC testing is not the only court ready testing we are able to provide (controlled substances, blood alcohol content, etc.), it is a very prominent need across the state. The state labs do provide testing essentially for no cost. They also have limitations. They test what they choose, do not accept anything with batteries, do not test edibles, do not report a quantitative number only above or below 1 %, and take up to 18 months to provide a result. We provide testing up to the penalty group requested, accept all samples, can test edibles, vapes, gummies, etc, provide a quanitative value with uncertainty as required, and provide most results in under two weeks. Our website is AFLab.com. httos: / /aflab.com/10-things-about-mariivana-testing-irt-texas/ httos: / /aflab.com/10-more-things-about-mariivana-testinR-in-texas/ httvs: / /aflab.com/ total delta9thcisdelta9anddelta9thca/ Please feel free to ask the Tarrant County District Attorneys about our work and if we would be a beneficial addition. Please let me know any questions you may have and any way we may be of service. 2-1 Providing a World of Serzrices 75' Page one o f o ne Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 15 of 63 Armstrong Forensic Laboratory, Inc. 330 Lcch'n Green Trail Arlington, Texas 76012-3458 817-273-2691 Fax:817-275-1883 Kathryn Agee -Dow FW Water Department RE: Full Force Letter 0 Andrew T. Armstrong, PhD Marion K. Armstrong MSPH, MBA, CIH Kelly L. wouters, PhD Karen M. Deiss, BS Armstrong Forensic Laboratory, Inc. (Armstrong) is a full service, multi -disciplinary analytical laboratory located in the heart of the Dallas/Fort Worth Metroplex. Armstrong is focused on providing quality Client response and service. Armstrong's expertise is in comprehensive, analytical laboratory services that centers on accurate results. More than 35 years of service to private industries and government agencies confirm Armstrong's excellent reputation in the areas of industrial hygiene, environmental analysis, product safety, and fire chemistry. Armstrong holds accreditation from four international ISO/IEC organizations as well as State and Federal licensures. The NCTRCA certifies Armstrong as a Woman -Owned Business Enterprise (WBE) and a Historically Underutilized Business (HUB). Armstrong performs analyses in support of government agencies' requirements and private industries. Armstrong provides collection and analytical services to municipal and wastewater plants to meet regulatory requirements. Industrial clients, engineering firms, and consultants utilize Armstrong to correctly characterize waste from various sources. Armstrong is certified by the Texas Commission on Environmental Quality (TCEQ) with accreditation through The NELAC Institute (TNI), Armstrong has become highly skilled in performing analyses required with state- of-the-art instrumentation and approved methodology. Environmental analytical services include: Petroleum Storage Tank Services EP-TOX (Extraction Procedure Toxicity Test Method) BTEX (Benzene, Toluene, Ethyl benzene, Xylene) RCRA Metals TCLP Extraction (Toxicity Characteristic Leaching Process) Total Organic Halogens Total Petroleum Hydrocarbon Wastewater Handling BOD (Biochemical Oxygen Demand) COD (Chemical Oxygen Demand) Conductivity Nitrates Hexane Extractable Materials TSS (Total Suspended Solids) Total Toxic Organics � Providing a World of Services 9a Page one of two Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 16 of 63 Armstrong Forensic Laboratory, Inc. FW Water Department Page 2 of 2 Stormwater Runoff Analyses Chlorinated Pesticides Cyanide and Phenols Orthophosphate Priority Pollutant Metals Semi -Volatile Organic Compounds Total Residual Chlorine Volatile Organic Compounds National Primary & Secondary Drinking Water Standards, 40CFRI41 & 40CFRI43 Alkalinity Anions (Nitrate, Nitrite, Fluoride) Coliforms Corrosivity/ pH Metals Pesticides TDS (Total Dissolved Solids) Trihalomethanes Turbidity Air • Lead All methods utilized for environmental analyses are EPA and TCEQ approved procedures. In addition, Armstrong provides method development and modification when required. Please feel free to ask our references about our work and if we would be a beneficial addition. Please let me know any questions you may have and any way we may be of service. Respectfully submitted, g Forensic Labo Inc. Benjamin N. Ar strong, BS Presider A1HA Accreditation Certificate 101413 TCEQ T104704240-23-19 PJLA Certificate L23-556/Accreditation 64631 ANAB, Certificate FT-0293 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 17 of 63 EXHIBIT B FEESCHEDULE Armstrong Forensic Laboratory, Inc. dw ' 2025 FEE SCHEDLjL THC Quantitation .0 Coroi'ted Substance Identifica ion B1 v od Alcohol Conte Court Testimony d APMD A C C R E D I T F D FORENSIC TESTING LABORATORY Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 18 of 63 Analytical Cost Armstrong Forensic Laboratory, Inc. is accredited by ANAB and the TFSC to perform criminal casework in the State of Texas. Armstrong's analyses conform to ASTM and SWGDrug Identification Criteria and Code of Professional Practice. All analyses are performed in Texas by Texas Forensic Science Commission Licensed Analysts. THC IDENTIFICATION AND QUANTITATION IN PLANT MATERIAL $ 110/Unit THC IDENTIFICATION AND QUANTITATION IN NON -PLANT MATERIAL $ 180/Unit E-cigs, vapes, edibles, waxes, oils, and non -green leafy material CONTROLLED SUBSTANCE AND PHARMACEUTICAL IDENTIFICATION $ 90/Unit Additional components Reported, Same Sample $ 55/ each Quantitation of component $ 90/Unit WEIGHT ONLY $ 90/Unit BLOOD ALCOHOL CONTENT $100/Unit Consultation and Court Fees Kelly Wouters, Ph.D. Consultation, Travel, Phone and Standby Wren Busby, Ph.D. Consultation, Travel, Phone and Standby Blood Alcohol Analyst Consultation, Travel, Phone and Standby Court Presentation and Deposition Video Deposition Affidavit of Laboratory Analysis Court Ready Data Package of Laboratory Analysis Duces Tecaut Evidence Storage (6 mos.) Evidence Return Shipping $ 345 /Hour $ 295 /Hour $ 200 /Hour Additional $100/ Hour Additional $ 200/ Hour $100.00/Case $ 250.00/Case $ 750.00/Case $ 75.00/Case $ 65.00/Box Vendor Services Agreement - Armstrong Forensic Laboratory, Inc. Page 19 of 63 Notes Controlled Substance Full Scan represents a full analysis, including weight and report of the primary controlled substance in the item or sub -sample. Quantitative results (purity) are a separate analysis from the identification. Depending on the number of different units submitted as a single item, multiple sub -samples may be required for a representative analysis. For evidence that must be sub -sampled to meet analytical methodologies, each sub -sample will be treated as an individual unit. The are no hidden fees for client cancellation, set up, untested samples, difficult samples, or sample cancellation due to insufficient sample. Armstrong maintains a library of reference standards including numerous synthetic drugs. If a submitted sample contains a controlled substance not already included in Armstrong's libraries, the purchase of a reference standard may be necessary to confirm the identification. In the event any additional standards are necessary, Armstrong will contact the Client for approval. Armstrong responds to requests from prosecutors handling the case, provides requested materials, and invoices the submitting agency, unless specifically directed otherwise by the submitting agency. Additional Component is considered to mean any other potentially significant analyte identified within the results; controlled or non -controlled by the State of Texas. Event Charges may be incurred when Armstrong is requested to provide services that require efforts beyond the scope of its standard work -shift. (Mon.- Fri., 7a.m. - 6 p.m.) Travel Expenses are charged as a Pass Through Cost. Mileage is charged at $0.70 per mile. Armstrong requests completed evidence be picked up or scheduled for return shipping within two weeks after the completion of the report. Evidence left at Armstrong for more than 30 days may be returned to the submitting agency at the agency's expense. Armstrong is not a licensed destruction facility and cannot destroy or discard controlled substances and related evidence. Expedited Turn -around Options: ASAP TAT-100% Analytical Surcharge 5 Day TAT —50% Analytical Surcharge Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 20 of 63 Armstron Forensic Laboratory, Inc. 9 Providing a World of Services 330 Loch'n Green Trail, Arlington, Texas 76012 Voice: (817) 275-2691 Fax: (817) 275-1883 www.AFLab.com E-mail: AFLab@AFLab.com Armstrong Forensic Laboratory, Inc August 31, 2023 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 21 of 63 Armstrong Forensic Laboratory, Inc. Laboratory Qualifications Organization and Management Chairman, Board of Directors: President: Senior Vice President and Technical Director Vice President of Services: Quality Assurance Director: Laboratory Director: Senior Consultant: Kay F. Armstrong, BS MT (ASCP) Benjamin N. Armstrong, BBA Andrew T. Armstrong, PhD, Fellow ABC Marion K. Armstrong, MSPH, MBA, CIH, MAC Chelynne A. Washington, BS Kelly L. Wouters, PhD, Fellow ABC Karen M. Deiss, BS Accreditations, Certifications, and Registrations American Industrial Hygiene Association - Laboratory Accreditation Program (AIHA-LAP): Industrial Hygiene Laboratory Accreditation Program (IHLAP) Environmental Lead Laboratory Accreditation Program (ELLAP) ANSI National Accreditation Board (ANAB): Seized Drugs: Qualitative Analysis, Quantitative Analysis Toxicology: Qualitative and Quantitative Analysis of Volatiles Materials (Trace): Fiber and Textiles, General Unknown Fire Debris Texas Forensic Science Commission (TFSC): Seized Drugs: Qualitative Analysis, Quantitative Analysis Toxicology: Qualitative and Quantitative Analysis fo Volatiles Materials (Trace): Fiber and Textiles, General Unknown Fire Debris Texas Commission on Environmental Quality (TCEQ): Air Emissions, Non -Potable Water, Solids and Chemical Materials Texas Department of Licensing and Regulation (TDLR): Mold Analysis Laboratory (MALab) Perry Johnson Laboratory Accreditation, Inc. (PJLA) Chemical Analysis and Mechanical Testing of Toys and Other Children's Products Department of Agriculture (DOA) Soil Permit Department of Justice (DOJ) Drug Enforcement Administration Controlled Substance Registration Texas Department of Public Safety Controlled Substance Registration Food and Drug Administration (FDA) Registered North Central Texas Regional Certification Agency (NCTRCA) WBE Certificate State of Texas HUB Certificate Technical Support and Contact Information Technical Support is available Monday through Friday, 9:00 a.m. - 5:00 p.m. After-hours messages and orders can be left at (817) 275-2691. For emergencies, call (817) 921-2461, 24 hours. 330 Loch'n Green Trail Arlington, TX 76012 Armstrong Forensic Laboratory, Inc August 31, 2023 Voice: (817) 275-2691 Fax: (817) 275-1883 Email: AFLab@AFLab.com Web: www.AFLab.com Page Q1 of 1 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 22 of 63 Product Testing Services CPSIA Compliance (HR4040) Lead in Paint and Surface Coatings (16CFR1303, ASTM F963-07 4.3.5) CPSC (ASTM F963.07) California Proposition 65 Other Services European Standard Corporate Specifications Hasbro Mattel Armstrong Forensic Laboratory, Inc August 31, 2023 Section A Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 23 of 63 Product Testing Services Description of Service Recommended Testing Evaluation and Cost Estimate No Charge CPSIA Compliance (HR4040) Lead in Children's Metal Products CPSC CH E1001-08 $55.00 Lead in Cluldren's Non -Metal Products CPSC CH E1002-08 $55.00 Phthalates in Children's Products (8) CPSC CH C1001-09 $225.00 BBP, DEHP, DBP, DINP, DPENP, DnHP, DCHP, DIBP Lead in Paint and Surface Coatings (16CFR1303, ASTM F963-07 4.3.5) Lead in Paint and Surface Coatings CPSC CH E1003-09 $50.00 CPSC (ASTM F963.07) Age Grading - Packaging and Labeling Evaluation $245.00 Flammability ASTM F963 4.2 $75.00 Small Parts ASTM F963 4.6 $55.00 Sharp Edges ASTM F963 4.7 $55.00 Sharp Points ASTM F963 4.8 $55.00 Use and Abuse Processing Per Toy $250.00 Includes Normal Use ASTM F963 8.5 $55.00 Impact Test ASTM F963 8.7 $55.00 Torque Test ASTM F963 8.8 $55.00 Tension ASTM F963 8.9 $55.00 Compression ASTM F963 8.10 $55.00 Flex Test ASTM F963 8.12 $55.00 Lead in Paint and Surface Coatings CPSC CH E1003-09 $55.00 Soluble Heavy Metals in Surface Coatings ASTM F963 4.3.5.2 $195.00 Antimony, Arsenic, Banum, Cadmium, Chmausim, Lead, Mercury and Selenium California Proposition 65 Lead in Paint and Surface Coatings CPSC CH E1003-09 $55.00 Lead in Children's Metal Products CPSC CH E1001-08 $55.00 Lead in Children's NonMetalProducts CPSC CH E1002-08 $55.00 Lead in Children's Jewelry EPA 3050, EPA 6010, EPA 7000 $55.00 Phthalates in Children's Products (7) CPSC CH C1001-09 $225.00 BBP, DEHP, DBP, DIDP, DINP, DNOP, DNHP Other Services General Certificate of Conformity (GCC) $95.00 Sample Breakdown for Testing $50.00 Armstrong Forensic Laboratory, Inc Page Al of 2 August 31, 2023 Vendor Services Agreement - Armstrong Forensic Laboratory, Inc. Page 24 of 63 Product Testing Services Description of Service European Standard Mechanical and Physical Properties EN 71 Part 1 $300.00 Flammability EN 71 Part 2 $175.00 Migration of Certain Elements EN 71 Part 3 $225.00 Corporate Specifications Hasbro Heavy Metals in Surface Coatings SRS-012 $225.00 Antimony, Arsenic, Barium, Cadmium, Chromium, Lead, Mercury and Selenium Heavy Metals in Paper and Fabric SRS-047 $225.00 Antimony, Arsenic, Barium, Cadmium, Chromium, Lead, Mercury and Selenium Heavy Metals in Plastic, Metal and Wood SRS-044 $225.00 Antimony, Arsenic, Banum, Cadmium, Chromium, Lead, Mercury and Selenium Heavy Metals in Throw Away Packaging SRS-082 $225.00 Cadmium, Hexavalent Chromium, Lead and Mercury Phthalate Plasticizers (6) SRS-046 $195.00 BBP, DEHP, DBP, DIDP, DINP, DNOP Flammability SRS-013 $175.00 Mattel Testing Soluble Heavy Metals QSOP 0006-3600 $225.00 Antimony, Arsenic, Banum, Cadmium, Chromium, Lead, Mercury and Selenium Phthalate (7) QSOP 0006-3610 $225.00 BBP. DEHP. DBP. DIDP. DINP. DNOP. DNHP Armstrong Forensic Laboratory, Inc August 31, 2023 Page A2 of 2 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 25 of 63 Industrial Hygiene Services Analytical Group Listing Prices are outlined in the following groups: Acids, Inorganic Aldehydes Isocyanates Amines, Aliphatic Amines, Aromatic Anions Cations Dust/ Particulates Gases Indoor Air Quality Screens Isocyanates Metals - Individual Metals - Group Organics, Gas Chromatography Organics, Multi -Component Organics, Total Organics Pesticides, Phosphate Pesticides, Pyrethrin Polynuclear Aromatic Hydrocarbons (PAH's) Titration Armstrong Forensic Laboratory, Inc August 31, 2023 Section B Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 26 of 63 Industrial Hygiene Services, Analytical Group Listing Test Name Test Code Method Dept Media Pricing Acids, Inorganic Fluoride FLUORIDE,SOL-F/N7906 NIOSH 7906 LC/IC 225-9031 $175.00 TAL $175.00 First Analyte $60.00 Additional Analyte Fluoride FLUORIDE,TOT-F/N7906 NIOSH 7906 LC/IC 225-9031 $175.00 TAL $175.00 First Analyte $60.00 Additional Analyte Volatile Acids VOLACIDS-F/N7907 NIOSH 7907 LC/IC 225-9032 $175.00 TAL Non -Volatile Acids NONVOLACIDS-F/N7908 NIOSH 7908 LC/IC 225-9033 $175.00 TAL Aldehydes Aldehydes List 1 ALD(I)-M/N2539 NIOSH 2539 FID 226-118 $275.00 TAL $145.00 First Analyte $75.00 Additional Analyte Aldehydes List ALD(II)-M/ET011 EPATO-11 LC/IC Sep -Pak $195.00 TAL $145.00 First Analyte $40.00 Additional Analyte Aldehydes List 3 ALD(III)-M/ET011 EPATO-11 LC/IC Sep -Pak $275.00 TAL $145.00 First Analyte $40.00 Additional Analyte Aldehydes List ALD(II)-WIPE/ET011 EPATO-11 LC/IC Wipe $195.00 TAL $145.00 First Analyte $40.00 Additional Analyte Aldehydes List ALD(III)-WIPE/ET011 EPATO-11 LC/IC Wipe $275.00 TAL $145.00 First Analyte $40.00 Additional Analyte Isocyanates ISOCYAN-M/O5002 LC/IC Tr GFF $225.00 TAL $145.00 First Analyte $50.00 Additional Analyte Amines, Aliphatic Aliphatic Amines AMINES, ALI-M/N2010 NIOSH 2O10 FID 226-10 $195.00 Each Amines, Aromatic Aromatic Anunes AMINES, ARO-M/N2002 NIOSH 2O02 FID 226-10 $340.00 TAL $195.00 First Analyte $75.00 Additional Analyte Anions Anions ANIONS-WIPE/E300 EPA300 LC/IC Wipe $195.00 TAL $125.00 First Analyte $95.00 Additional Analyte Armstrong Forensic Laboratory, In August 31, 2023 Page Bl of 5 Vendor Services Agreement - Armstrong Forensic Laboratory, Inc. Page 27 of 63 Industrial Hygiene Services, Analytical Group Listing Test Name Test Code Method Dept Media Pricing Cations Cations CATIONS-WIPE/ASTM D6919 ASTM D6919 LC/IC Wipe $195.00 TAL $125.00 First Analyte $95.00 Additional Analyte Dust/Particulates Asbestos ASBEST-B/OSS EPA 600/M4-82- OSS Solid $29.50 Each 020 Asbestos ASBEST-MULTI-B/OSS EPA 600/M4-82- OSS Solid $44.00 Each 020 Asbestos ASBESTFC-M/N7400 NIOSH 7400 OSS CEF 25mm $29.50 Each Total Dust (Tared Filter) PNOR-TT/N0500 NIOSH 0500 GRAV Tared PVC $30.00 Each Total Dust (Mt. Wt. Filter) PNOR-TMW/N0500 NIOSH 0500 GRAV MWCEF 37mm $30.00 Each Respirable Dust (Tared Filter) PNOR-RT/N0600 NIOSH 0600 GRAV Tared PVC $30.00 Each Respirable Dust (Mt. Wt. Filter) PNOR-RMW/N0600 NIOSH 0600 GRAV MWCEF 37mm $30.00 Each Respirable Crystalline Silica SILICA, RESP-F/N7500 NIOSH 7500 XRD Tared PVC $110.00 TAL $75.00 Filet Analyte $30.00 Additional Analyte Total Crystalline Silica SILICA, TOTAL-F/N7500 NIOSH 7500 XRD Tared PVC $110.00 TAL $75.00 First Analyte $30.00 Additional Analyte Total Crystalline Silica SILICA-BULK/N7500 NIOSH 7500 XRD Solid $115.00 Each Gases Air Gases AIR GASES/ASTM1946 ASTM D1946 OSS Tedlar Bag $255.00 Each Indoor Air Quality Screens EPA TO-01 Volatile Compounds TO-01 EPA TO-01 Unknown ID TO-01SQ Armstrong Forensic Laboratory, In August 31, 2023 EPATO-01 MS Tmax Tube $395.00 TAL EPATO-01 MS Tmax Tube $495.00 TAL Page B2 of 5 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 28 of 63 Industrial Hygiene Services, Analytical Group Listing Test Name Test Code Method Dept Media Pn=g EPA TO-15 Unknown ID TO-15SQ EPATO-15 MS Varies $455.00 TAL Clean and QC check Client CLEAN&QC-SUMMA EPA TO-14 MS Summer Canister $90.00 Each Summa Can Isocyanates Isocyanates ISOCYAN-M/047 OSHA47 LC/IC Tr GFF $225.00 TAL $145.00 First Analyte $50.00 Additional Analyte Metals - Individual Lead LEAD-PAINT/E6010 EPA 6010C METAL Paint $45.00 Each Lead LEAD-PAINT/E7000 EPA 7000 METAL Paint $45.00 Each Metals (ICP) MET-F/N7303 NIOSH 7303 METAL CEF 37mm $45.00 First Analyte $30.00 Additional Analyte Mercury Vapor MERCURY-M/N6009 NIOSH 6009 METAL 226-17-1A $60.00 Each Mercury Vapor MERCURY-M/0140 OSHA ID 140 METAL 226-17-1A $60.00 Each Mercury Particulate MERCURY-M/OID145 OSHA ID 145 METAL CEF 37mm $60.00 Each Mercury MERCURY-WIPE/OID145 OSHA ID 145 METAL Wipe $60.00 Each Metals - Group Welding Fumes METI3SCR-F/N7303 NIOSH 7303 METAL CEF 37mm $175.00 TAL $45.00 First Analyte $30.00 Additional Analyte Expanded Welding Fumes MET15SCR-F/N7303 NIOSH 7303 METAL CEF 37mm $190.00 TAL $45.00 First Analyte $30.00 Additional Analyte Organics, Gas Chromatography BTEX by NIOSH 1501 BTEX-M/N1501 NIOSH 1501 FID 226-01 $275.00 TAL $125.00 First Analyte $75.00 Additional Analyte Alcohols List 1 ALCOHOLl-M/N1400 NIOSH 1400 FID 226-01 $275.00 TAL $125.00 First Analyte $75.00 Additional Analyte Armstrong Forensic Laboratory, In Page B3 of 5 August 31, 2023 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 29 of 63 Industrial Hygiene Services, Analytical Group Listing Test Name Test Code Method Dept Media Pricing Alcohols List 2 ALCOHOL2-M/N1401 NIOSH 1401 FID 226-01 $275.00 TAL $125.00 First Analyte $75.00 Additional Analyte Alcohols List 3 ALCOHOL3-M/N1402 NIOSH 1401 FID 226-01 $275.00 TAL $125.00 First Analyte $75.00 Additional Analyte Alcohols List 4 ALCOHOL4-M/N1403 NIOSH 1403 FID 226-01 $275.00 TAL $125.00 First Analyte $75.00 Additional Analyte BTEX BTEX-PD/3M 3M OVM/GC-FID FID 3M 3500 $160.00 TAL $80.00 First Analyte $30.00 Additional Analyte BTEX/MTBE BTEXM-PD/3M 3MOVM/GC-FID FID 3M 3500 $185.00 TAL $80.00 Fist Analyte $30.00 Additional Analyte Dichlorobenzenes DICHLBENZENES-M NIOSH 1003 FID 226-01 $275.00 TAL $125.00 First Analyte $75.00 Additional Analyte Esters ESTERSI-M/N1450 NIOSH 1450 FID 226-01 $125.00 First Analyte $75.00 Additional Analyte Aromatic Hydrocarbons HYD,ARO-M/N1501 NIOSH 1501 FID 226-01 $125.00 First Analyte $75.00 Additional Analyte Halogenated Hydrocarbons HYD,HALO-M/N1003 NIOSH 1003 FID 226-01 $125.00 First Analyte $75.00 Additional Analyte Hydrocarbons HYD-M/N1500M NIOSH 1500 FID 226-01 $125.00 First Analyte $75.00 Additional Analyte Hydrocarbons (CS2) HYD-3M/CS2 3M O VM/GC-FID FID 3M 3500 $80.00 First Analyte $30.00 Additional Analyte Hydrocarbons (MECL2) HYD-3M/MECL2 3M OVM/GC-FID FID 3M 3500 $80.00 First Analyte $30.00 Additional Analyte Ketones List 1 KETONEI-M/N1300 NIOSH 1300 FID 226-01 $195.00 TAL $125.00 Fist Analyte $75.00 Additional Analyte Ketones List KETONE2-M/N1301 NIOSH 1301 FID 226-01 $275.00 TAL $125.00 First Analyte $75.00 Additional Analyte Organics, Multi -Component MultrcomponentHydrocarbons HYDMIX-M/N1550 NIOSH1550 FID 226-01 $125.00 First Analyte $75.00 Additional Analyte Armstrong Forensic Laboratory, In August 31, 2023 Page B4 of 5 Vendor Services Agreement - Armstrong Forensic Laboratory, Inc. Page 30 of 63 Industrial Hygiene Services, Analytical Group Listing Test Name Test Code Method Dept Media Pricing Multicomponent Hydrocarbons HYDMIX'3M/CS2 3MOVM/GC-FID FID 3M3500 $125.00 First Analyte $75.00 Additional Analyte Organics, Total Organics TVOC TVOC-TENAX/ETOI EPATO-1 MS Tmax Tube $250.00 Each Pesticides, Phosphate Phosphate Pesticides List 1 PEST,PHOS-M-Ll/N5600M NIOSH 5600 Mod MS 226-55 $275.00 TAL $135.00 First Analyte $65.00 Additional Analyte Phosphate Pesticides List 2 PEST,PHOS-M-L2/N5600M NIOSH 5600 Mod MS 226-55 $325.00 TAL $135.00 First Analyte $65.00 Additional Analyte Pesticides, Pyrethrin Pyrethrin Pesticides PEST,PYR-M/070M OSHA 70 ECD 226-30-16 $295.00 TAL $150.00 First Analyte $75.00 Additional Analyte Polynuclear Aromatic Hydrocarbons (PAH's) PAH List 1 (HPLC) PNA5-M/N5506 NIOSH 5506 LC/IC 226-30-04 $300.00 TAL $200.00 First Analyte $60.00 Additional Analyte PAH List 2 (HPLC) PNA9-M/N5506 NIOSH 5506 LC/IC 226-30-04 $350.00 TAL $200.00 First Analyte $60.00 Additional Analyte PAH List (HPLC) PNA16-M/N5506 NIOSH 5506 LC/IC 22630-04 $400.00 TAL $200.00 First Analyte $60.00 Additional Analyte PAH List 1 (MS) PNA5-M/N5515 NIOSH 5515 MS 226-30-04 $175.00 TAL $125.00 First Analyte $60.00 Additional Analyte PAH List (MS) PNA9-M/N5515 NIOSH 5515 MS 226-30-04 $225.00 TAL $125.00 First Analyte $60.00 Additional Analyte PAH List (MS) PNA16-M/N5515 NIOSH 5515 MS 22630-04 $275.00 TAL $125.00 First Analyte $60.00 Additional Analyte Titration Alkaline Dusts ALKDUST-F/N7401 NIOSH 7401 WC PTFE $125.00 Each Armstrong Forensic Laboratory, In Page B5 of 5 August 31, 2023 Vendor Services Agreement - Armstrong Forensic Laboratory, Inc. Page 31 of 63 Industrial Hygiene Services, Analytical Group Listing Test Name Method 1,6-Hexamethylene diisocyanate 4,4'-Methylene bisphenyl isocyanate 2,4-Toluene diisocyanate 2,6-Toluene diisocyanate Alcohols List 1 NIOSH 1400 tert-Butyl alcohol Ethyl alcohol Isopropyl alcohol Alcohols List 2 NIOSH 1401 n-Butyl alcohol sec -Butyl alcohol Isobutyl alcohol n-Propyl alcohol Alcohols List 3 NIOSH 1401 Allyl alcohol Cyclohexanol Diacetone alcohol Isoamyl alcohol Methyl isobutyl carbmol Alcohols List 4 NIOSH 1403 2-13utoxyethanol 2-Ethoxy ethanol Methyl cellusolve Aldehydes List 1 NIOSH 2539 Acetaldehyde Butyraldehyde Isobutyraldehyde Isovaleraldehyde Propionaldehyde Valeraldehyde Aldehydes List 2 EPA TO-11 Acetaldehyde Acrolem Be —aldehyde Formaldehyde Glutaraldehyde Isovaleraldehyde Valeraldehyde Aldehydes List 3 EPA TO-11 Acetaldehyde Acrolein Be —aldehyde n-Butyraldehyde Crotonaldehyde 2,5-Dimethylbenzaldehyde Formaldehyde Glutaraldehyde Hexanaldehyde Isovaleraldehyde Propionaldehyde m-Tolualdehyde o-Tolualdehyde p-Tolualdehyde Valeraldehyde Anions EPA 300 Protrude Chlonde Nitrate Nitrite Phosphate Sulfate Aromatic Amines NIOSH 2O02 Aniline N,N-dimethylanihne N,N-dimethyl-p-toluidme o-Toluidme 2,4-Xylidine Aromatic Hydrocarbons NIOSH 1501 Benzene p-ten Butyl toluene Cumene Ethylbenzene alpha Methyl styrene Naphthalene Styrene Toluene Vinyl toluene o-Xylene m&p-Xylene Total Xylenes BTEX 3M OVM/GC Benzene Toluene Ethylbenzene Total Xylenes BEE by NIOSH 1501 NIOSH 1501 Benzene Toluene Ethylbenzene Total Xylenes BTEX/MTBE 3M OVM/GC Benzene Toluene Ethylb—me Total Xylenes Methyl tert butyl ether Cations ASTM D6919 Ammonium Calcium Lithium Magnesium Potassium Sodium Dichlorobenzenes NIOSH 1003 1,2-Dichlombenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene Armstrong Forensic Laboratory, Inc August 31, 2023 Page Bl of 4 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 32 of 63 Industrial Hygiene Services, Analytical Group Listing Test Name Esters n-Amyl acetate sec -Butyl acetate Ethyl acrylate Methyl isoamyl acetate Expanded Welding Fumes Aluminum Cadmium Copper Manganese Titanium Fluoride Fluonde, soluble particulate Halogenated Hydrocarbons Benzylchloride Chlorobenzene 1,2-Dichlorobenzene Total 1,2-Dichloroethene Tetrachloroethene Trichloroethene Hydrocarbons Benzene n-Heptane Methylcyclohexane Toluene Hydrocarbons (CS2) Acetone Benzene 1-Bromopropane tert Butyl acetate Butyl cellosolve acetate Camphor Chlorobenzene o-Chlorostymne Cyclohexane Cyclopentane p-Dichlorobenzene Dichloroethyl ether Dnsobutyl ketone Dipropyl ketone Epichlorohydrin Ethylbenzene Ethylene dibromide Ethyl formate n-Hexane Isoamyl acetate Isooctal alcohol Isopropoxyethanol Isopropyl glycidyl ether Methyl acetate Methyl amyl ketone Methyl cellosolve acetate Methylene chloride Methyl isoamyl ketone Method NIOSH 1450 sec -Amyl acetate tert Butyl acetate Isoamyl acetate n-Propyl acetate NIOSH 7303 Antimony Chromium Iron Molybdenum Vanadium NIOSH 7906 Fluonde, Total particulate NIOSH 1003 Bromoform Chlorobromomethane 1,4-Dichlorobenzene Ethylene dichloride L1,1-Trichloroethane L2,3-Trichloroprop ane NIOSH 1500 Cyclohexane n-Hexane n-Octane 3M OVM/GC Armstrong Forensic Laboratory, Inc August 31, 2023 Allyl chloride Benzyl chloride n-Butyl acetate Butyl acrylate Butyl glycidyl ether Carbon tetrachloride Chlorobromomethane o-Chlorotoluene Cyclohexanone n-Decane Ll-Dichloroethane Dicyclopentadiene p-Dioxane Divmyl benzene Ethyl acetate Ethyl bromide Ethylene dichloride n-Heptane Hexane isomers Isobutyl acetate Isopar G Isopropyl acetate Mesitylene Methyl acrylate Methyl tert-butyl ether Methyl cyclohexane Methyl ethyl ketone Methyl isobutyl carbinol n-Butyl acetate 2-Ethoxyethyl acetate Isobutyl acetate Beryllium Cobalt Lead Nickel Zinc Fluoride, vapor Carbon tetrachloride Chlomform 1,1-Dichloroethane Hexachloroethane 1,1, 2-T richl oro ethane Cyclohexee Hexene n-Pentane n-Amyl acetate Bromoform 5-Butyl acetate t-Butyl alcohol p-tert-Butyltoluene Cellosolve acetate Chloroform Cumene Cyclohexee o-Dichlorobenzene 1,2-DicMoroethene Diethyl ketone Dipropylene glycol methyl ether n-Dodecane Ethyl acrylate Ethyl butyl ketone Ethyl ether Hexachlorethane 1-Hexene Isoflurane Isophorone Isopropyl ether Mesityl oxide Methylal Methyl butyl ketone Methyl cyclohexanol 5-Methyl 3-heptanone Methyl isobutyl ketone Page B2 of 4 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 33 of 63 Industrial Hygiene Services, Analytical Group Listing Test Name Method Methyl isopropyl ketone Methyl methacrylate Methyl propyl ketone alpha -Methyl styrene Naphthalene n-Nonane n-Octane n-Pentane 2,4-Pentanedione Perchloroethylene Phenyl ether Phenyl glycidyl ether n-Propyl acetate Propylene dichloride Propylene glycol methyl ether acetate Propylene oxide n-Propyl nitrate Styrene 1,1,2,2-Tetrachloroethane Tetrahydrofuran Toluene E L I-Tnchloroethane 1,1,2-Tnchloroethane Tnchlorethylene 1,2,3-Trichloropropane 1,1,2-Trichloro-1,2,2-trifluoroethane Vinyl acetate Vinyl chloride 4-Vinyl-l-cyclohexene Vinyhdene chloride Vinyl toluene o-Xylene m&p-Xylene Total Xylenes Hydrocarbons (MECL2) 3M OVM/GC Allyl alcohol -Amyl alcohol s-Amyl alcohol 1,3 Butadiene n-Butyl alcohol s-Butyl Alcohol Butyl cellosolve Cellosolve Cyclohexanol Diacetone alcohol Dimethylacetaturde Dimethyl formanude Ethylene chlorohydnn Furfural Furfuryl alcohol Isoamyl alcohol Isobutyl alcohol Methyl cellosolve Methyl formate 1-Methyl-2-pyrrohdmone n-Propyl alcohol Propylene glycol monomethyl ether Isocyanates OSHA 47 1,6-Hexamethylene diisocyanate 4,4'-Methylene bisphenyl isocyanate 2,4-Toluene diisocyanate 2,6-Toluene diisocyanate Ketones List 1 NIOSH 1300 Acetone Cyclohexanone Ditsobutyl ketone 2-Hexanone Methyl isobutyl ketone 2-Pentanone Ketones List 2 NIOSH 1301 Ethyl butyl ketone Methyl n-amyl ketone 5-Methyl 3-heptanone Metals (ICP) NIOSH 7303 Aluminum Antimony Ars emc Barium Beryllium Bismuth Boron Cadmium Calcium Chromium Cobalt Copper Gallium Indium Iron Lead Magnesium Manganese Molybdenum Nickel Phosphorous Potassium Selenium Sodium Strontium Thallium Tin Titamum Vanadium Zmc Multicomponent Hydrocarbo NIOSH 1550 Coal tar naphtha (CS-C10) Coal tar naphtha (C8-C10) Kerosene Kerosene (C9-C16) Mineral spirits (C9-C12) Mineral spirits (C9-C12) Naphtha (C6-C11) Naphtha (C6-Cll) Petroleum distillates (CC C8) Petroleum Naphtha (C6-C8) Petroleum ether (C5-C6) Stoddard Solvent (C9-C12) Petroleum naphtha (C6-C8) TPH DRO (>C12-C20) Rubber solvent (C5-C8) TPH GRO (C -C12) Stoddard solvent (C9-C12) VM&P Naphtha (C7-C11) TPH GRO (C6-C12) TPH DRO (C12-C20) TVOC (C -<C15) VM&P Naphtha (C7-Cll) PAH List 1 (HPLC) NIOSH 5506 Anthracene Benzo(a)pyrene Chrysene Phenanthrene Pyrene PAH List 1 (MS) NIOSH 5515 Anthracene Benzo(a)pyrene Chrysene Armstrong Forensic Laboratory, Inc Page B3 of 4 August 31, 2023 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 34 of 63 Industrial Hygiene Services, Analytical Group Listing Test Name Method Phenanthrene Pyrene PAH List 2 (HPLC) NIOSH 5506 Anthracme Benzo(a)anthracene Benzo(a)pyrme Chrysene Fluoranthene Fluorene Naphthalene Phenanthrene Pyrene PAH List 2 (MS) NIOSH 5515 Anthracme Benzo(a)anthracene Benzo(a)pyrme Chrysene Fluoranthene Fluorene Naphthalene Phenanthrme Pyrene PAH List 3 (HPLC) NIOSH 5506 Acenaphthene Acenaphthylene Anthracene Benzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(g,h,i)perylene Benzo(k)fluorenthene Chrysene Dibenz(a,h)anthracme Fluoranthene Fluorene Indeno(1,2,3-cd)pyrme Naphthalene Phenanthrene Pyrene PAH List 3 (MS) NIOSH 5515 Acenaphthene Acenaphthylene Anthracene Benzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(g,h,i)perylene Benzo(k)fluoranthene Chrysene Dibenz(a,h)anthracene Fluoranthene Fluorene Indeno(1,2,3-cd)pyrme Naphthalene Phenanthrene Pyrene Phosphate Pesticides List NIOSH 5600 Methyl azinphos Chlorpynfos Diazinon Disulfoton Malathion Methyl parathion Ethyl parathion Phosphate Pesticides List NIOSH 5600 Methyl azinphos Chlorpyrifos Diazinon Dichlorvos Disulfoton Ethoprop Malathion Mevinphos Methyl parathion Ethyl parathion Tetraethyl pyrophosphate Tetrachlorvinphos Pyrethrin Pesticides OSHA 70 Cypermethrin I Cypermethrin II Deltamethnn I Lambda cyhalothnn I Permethrin, cis Permethnn, trans Phenothnn I Pyrethnn I Pyrethrin II Tralomethrin Respirable Crystalline Silica NIOSH 7500 Quartz, Respirable % Quartz, Respirable Cnstobahte, Respirable %Cnstobahte, Respirable Silica, Respirable % Silica, Respirable Total Crystalline Silica NIOSH 7500 Quartz, Total % Quartz, Total Cnstobahte, Total % Cristobalite, Total Silica, Total % Silica, Total Silver Membrane Welding Fumes NIOSH 7303 Antimony Beryllium Cadmium Chromium Cobalt Copper Iron Lead Manganese Molybdenum Nickel Vanadium Zinc Armstrong Forensic Laboratory, Inc August 31, 2023 Page B4 of 4 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 35 of 63 Industrial Hygiene Services Individual Analyte List Analytes are outlined in alphabetical order. Armstrong Forensic Laboratory, Inc August 31, 2023 Section C Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 36 of 63 Alphabetical List of Analytes Test Name Test Code Method Dept Media Pneing A Acetic Acid ACETIC ACID-M/N1603 NIOSH 1603 OSS 226-01 $150.00 Each Acetone ACETONE-3M 3M OVM/GC- FID 3M 3500 $125.00 Each FID Acetonitnle ACETONITRILE-M/N1606 NIOSH 1606 FID 226-09 $125.00 Each Acrylonitnle ACRYLONITRILE-M/N1604 NIOSH 1604 FID 226-01 $125.00 Each Allyl chloride ALLYLCHLORIDE-M/N1000 NIOSH 1000 FID 226-01 $125.00 Each Ammoma AMMONIA-M/N6016 NIOSH 6016 LC/IC 226-10-06 $125.00 Each Ammoma AMMONIA-M/OID188 OSHA ID 188 LC/IC 226-29 $125.00 Each Analme ANALINE-M NIOSH 2O02 FID 226-10 $195.00 Each B Benzene BENZENE-PD/3M 3M OVM/GC- FID 3M 3500 $75.00 Each FID Benzene BENZENE-M/012 OSHA 12 FID 226-01 $125.00 Each Benzene soluble fraction BENSOLFRACTION-M/N5042 NIOSH5042 WC PTFE $125.00 Each Bromotnfluoromethane BROTRIFLUMETHANE-M/N1017 NIOSH 1017 FID 226-09 $125.00 Each 1,3-Butadiene 13BUTA-M/N1024 NIOSH 1024 FID 226-37 $125.00 Each 2-Butoxy ethyl acetate 2BUTOXETHYLACETATE-M OSHA 83 FID 226-01 $125.00 Each Butyl alcohol BUTYL ALCOHOL-3M 3M OVM FID 3M 3500 $125.00 Each Butylamine BUTYLAMINE-M/N2012 NIOSH 2O12 FID 226-53 $125.00 Each Butyl cellosolve acetate BUTCELACETATE-M/N1450MOD NIOSH 1450 FID 226-01 $125.00 Each Butyl glycidyl ether BUTGLYETHER-M/N1616 NIOSH 1616 FID 226-01 $125.00 Each C Calcium CALCIUM-M/N7020 NIOSH 7020 METAL CEF37mm $65.00 Each Camphor CAMPHOR-M/N1301 NIOSH 1301 FID 226-01 $125.00 Each Carbon disulfide CARBONDISULF-M/N1600 NIOSH 1600 FID 226-01 $125.00 Each Chlordane CHLORDANE-M/O67 OSHA67 ECD 226-30-16 $75.00 Each Chloroacetaldehyde CHLACEALDEHYDE-M/N2015 NIOSH 2015 ECD 226-15 $75.00 Each Chloroacetic acid CHLACEACID-M/N2008 NIOSH 2O08 LC/IC 226-47-01 $95.00 Each 2-Clloroethanol 2CHLETHANOL-M/N2513 NIOSH 2513 FID 226-91 $125.00 Each Chlorofluoromethane CHLFLUMETHAN-M/N1018 NIOSH 1019 FID 226-01 $125.00 Each 2-Chlorophenol 2CHLOROPHENOL-M/N2014 NIOSH 2O14 LC/IC 226-10 $145.00 Each Chloroprene CHLOROPRENE-M/N1002 NIOSH 1002 FID 226-01 $125.00 Each Chromium, Hexavalent HEXCHR/PAINT-M/OID215 OSHA ID 215 LC/IC Tared PVC $125.00 Each (Pamiang Process) Chronuum, Hexavalent HEXCHR/W-P-M/OID215 OSHA ID 215 LC/IC Tared PVC $85.00 Each (Welding or Plating Process) Coal Tar Pitch Volaflles CTPV-M/058 OSHA58 GRAV GET 37mm $225.00 Each Chromium, Hexavalent HEXCHR-M/N7600 NIOSH 7600 WC Tared PVC $85.00 Each Cresols CRESOL-M/O32 OSHA32 LC/IC 226-95 $125.00 Each Cresols CRESOL-M/N2546 NIOSH 2546 FID 226-95 $125.00 Each Cyclohexane CYCLOHEXANE-M NIOSH 1500 FID 226-01 $125.00 Each Cyclohexylamine CYCHEXAMINE-M/OPV2016 OSHAPV2016 FID Silica Gel Tube $125.00 Each 1,3-Cyclopentadiene 13CYCLOPENTADIENE-M/N2523 NIOSH 2523 FID Special $125.00 Each D Diazmon DIAZINON-M NIOSH 5515 MS OVS $125.00 Each Diazmon DIAZINON-WIPE NIOSH 5515 MS Wipe $125.00 Each Dibutyl phthalate DIBUTPHTHALATE-M/N5020 NIOSH5020 FID CEF37mm $125.00 Each Dichlorodifluoromethane DICHLDIFLUMETHANE-M/N1018 NIOSH 1018 FID 226-01 $125.00 Each Dichlorofluoromethane DICHLFLUMETHANE-M/N2516 NIOSH 2516 FID 226-25 $125.00 Each 1,I-Dichloro-l-nitroethane 11DICHLINHETHANE-M/N1601 NIOSH 1601 FID 226-91 $125.00 Each 1,2-Dichloropropme 12DICHLPROPANE-M/NI013 NIOSH 1013 ECD 226-91 $125.00 Each 1,2-Dichlorotetrafluoro-ethane 12DICHLTETFLUETHANE-M/N1018 NIOSH 1018 FID 226-01 $125.00 Each Diethylene glycol mono butyl DIET H GLYMON BUTETHER-M/OPV2095 OSHAPV2095 FID 226-01 $125.00 Each ether Diethyl ether DIETHETHER-M NIOSH 1610 FID 226-01 $125.00 Each Di-(2-ethylhexyl) phthalate DI2ETHHEXPHTHALATE-M/N5020 NIOSH 5020 FID CEF37mm $125.00 Each Armstrong Forensic Laboratory, Inc Page Cl of 4 August 31, 2023 Vendor Services Agreement - Armstrong Forensic Laboratory, Inc. Page 37 of 63 Test Name Alphabetical List of Analytes Test Code Method Dept Media Difluorodibromomethane DIFLUDIBROMETHANE-M/N1012 Dimethylacetamide DIMETACETAMIDE-M/N2004 Dimethylanaline DIMET H ANAL IN-M/N2002 Dimethylformamfde DIMETFORMAMIDE-M/N2004 Dimethylphthalate DIMETHPHTHALATE-M Dioxane DIOXANE-M/N1602 Diphenyl DIPH ENYL-M/ N2530 E Elemental carbon ELECARBON-F/N5040 Endrin EN DRIN-M/ N5519 Epichlorohydrin EPICHLOROHYDRIN-M/N1010 1,2-Epoxypropane 12EPDXYPROPANE-M/N1612 Ethanol ETHANOL-3M Ethanol amine ETHANOLAMINE-M/N2007 Ethyl acetate ETHACETATE-M/N1457 Ethyl bromide ETHBROMIDE-M/N1011 Ethyl chloride ETHCHLORIDE-M/N2519 Ethylene chlorohydrin ETHCHLHYDRIN-M/N2513 Ethylene dibromide ETHDIBROMIDE-M/N1008 Ethylene dichloride ETHDIC-M/N1003 Ethylene glycol ETHGLY-M Ethylene glycol monobutyl ETHGLYMONBUTETHER-M/N1403 ether Ethylene oxide ETHOXIDE-3M3551 Ethylene oxide ETHOXIDE-M/N1614 Ethyl ether ETHETHER-M/N1610 Ethyl formate ETHFORMATE-M/N1452 F Fiber Count FIBCOUNT-M Fiberglass FIBERGLASSM/N7400 Fluorotrichloromethane FLUTRICHLMETHANE-M/N1006 Formaldehyde FORM-M/N2541 Formaldehyde FORM-UMEX100/01007 Formaldehyde FORM-SEP PAK/ETO11 Furfural FURFURAL-M/ N2539 Furfuryl alcohol FURFURYL ALCOHOL-M/N2505 G Glutaraldehyde GLUT-SEP PAK/ETO11 Glycidol GLYCIDOL-M/ N1608 H 2-Heptanone 2HEPTANONE-M/N1300 Hydrogenfluonde HYDFLUORIDE-M/N7906 Hydrogen sulfide HYDSUL-M/N6013 Hydrogen sulfide HYDSUL-M/01008 Hydroquinone HYDROQUINONE-M/N5004 r Iron II oxide an/as Iron IROOXI-F/I Isophorone ISOPHORONE-M/N2508 Isopropyl acetate ISOPROPYL ACETATE-M/N1454 Isopropyl alcohol IPA3M Isopropyl ether ISOPROPYL ETHER-M/N1618 L Lead LEAD-F/N7082 Lead LEAD-F/01D121 Lead LEAD -WIPE / OID121 Armstrong Forensic Laboratory, Inc August 31, 2023 NIOSH 1012 FID 226-01 NIOSH 2O04 FID 226-10 NIOSH 2O02 FID 226-10 NIOSH 2O04 FID 226-10 OSHA 104 FID OVS NIOSH 1602 FID 226-01 NIOSH 2530 FID 226-35-01 NIOSH5040 OSS QFF37mm NIOSH 5519 ECD Filter NIOSH 1010 FID 226-01 NIOSH 1612 FID 226-01 3M OVM FID 3M 3500 NIOSH 2O07 FID 226-10-04 NIOSH 1457 FID 226-01 NIOSH 1011 FID 226-01 NIOSH 2519 FID 226-25 NIOSH 2513 FID 226-81 NIOSH 1008 ECD 226-01 NIOSH 1003 FID 226-01 NIOSH 5523 FID 226-57 NIOSH 1003 FID 226-01 3MOVM FID 3M 3551 NIOSH 1614 ECD 226-38-03 NIOSH 1610 FID 226-01 NIOSH 1452 FID 226-01 NIOSH7400 MIC CEF25mm NIOSH 7400 MIC CEF25mm NIOSH 1006 FID 226-09 NIOSH 2541 FID 226-118 OSHA1007 LC/IC 500-100 EPATO-11 LC/IC Sep -Pak NIOSH 2539 FID 226-118 NIOSH 2505 FID 226-115 EPATO-11 LC/IC Sep -Pak NIOSH 1609 FID 226-01 Pricing $125.00 Each $125.00 Each $195.00 Each $125.00 Each $125.00 Each $125.00 Each $125.00 Each $75.00 Each $85.00 Each $125.00 Each $125.00 Each $125.00 Each $170.00 Each $125.00 Each $125.00 Each $125.00 Each $125.00 Each $95.00 Each $125.00 Each $125.00 Each $125.00 Each $125.00 Each $95.00 Each $125.00 Each $125.00 Each $65.00 Each $65.00 Each $125.00 Each $125.00 Each $125.00 Each $125.00 Each $195.00 Each $125.00 Each $125.00 Each $125.00 Each NIOSH 1300 FID 226-01 $125.00 Each NIOSH 7906 LC/IC Tr CEF $125.00 Each NIOSH 6013 LC/IC Orbo 34 $125.00 Each OSHA1008 LC/IC Silica Gel Tube coa $125.00 Each NIOSH 5004 LC/IC CEF37mm $125.00 Each NIOSH 7300 METAL CEF37mm $50.00 Each NIOSH 2508 FID 226-91 $125.00 Each NIOSH 1454 FID 226-01 $125.00 Each 3M OVM FID 3M 3520 $125.00 Each NIOSH 1618 FID 226-01 $125.00 Each NIOSH 7082 METAL CEF37mm $45.00 Each OSHA ID121 METAL CEF37mm $45.00 Each OSHA ID121 METAL Wipe $45.00 Each Page C2 of 4 Vendor Services Agreement - Armstrong Forensic Laboratory, Inc. Page 38 of 63 Alphabetical List of Analytes Test Name Test Code M Mesityl oxide MESOXIDE-M/N1301 Methanol METHANOL-M/ N2000 2-Methoxyethyl acetate 2METETHACETATE-M/N1451 Methyl acetate METACETATE-M/N1458 Methyl acrylate METACRYLATE-M/N1459 Methylal METHYLAL-M/N1611 Methyl bromide METBROMIDE-M/N2520 Methyl cellosolve acetate METCELACETATE-M/N1451 Methyl chloride METHYLCHLORIDE-M/N1001 Methyl cyanoacrylate METCYAACRYLATE-M/OSHA55 Methylcyclohexanol METCYCHEXANOL-M/N1404 Methylcyclohexanone METCYCHEXANONE-M/N2521 Methylene chloride METCHL-3M Methylene chloride METCHL-M/N1005 4,T-Methylenedianilme 44MET DIAN ALINE-M/N5029 Methyl ethyl ketone peroxide METETHKETPER-M/N3508 Methyl iodide METHYL IODIDE-M/N1014 Methyl methacrylate METHMETHACRYLATE-3M Methylmethacrylate METHMETHACRYLATE-M Methyl propyl ketone METPROKETONE-M/N1300 Methyl tert butyl ether MTBE3M Methyl tert-butyl ether MTBE-M/N1615 Mineral spirits MINERAL SPIRITS-M/O48 Monomethylanihne MONMETANILINE-M/N3511 N Nicotine NICOTINE-M/N2551 Nitric oxide NITOXI-M/OID182 Nitric oxide/Nitrogen dioxide NITOXI/NIT DIO-M/OID182 Nitroethane NITETHANE-M Nitrogen dioxide NITDIO-M/OID182 Nitromethane NITMETHANE-M/N2527 1-Nitmpyrene NITROPYRENE-M/N5506 1-Nitropyrene NITROPYRENE-M/N5515 O Oil mist OIL MIST-M/N5026 Ozone OZONE-M/ OID214 P Particle Sizing & Count PARSIZ/CNT-F Phenol PHENOL-M/N2546 Phenol PHENOL-M/O32 Phosphine PHOSPHINE-M/0ID180 Phosphoric acid PHOSPHORIC ACID-M/OIDlll Polychlorinated biphenyls PCB-M/N5503 Potassium hydroxide m/as POTHYD-F/F Potassium Pyridine PYRIDINE-M/N1613 S Sodiumhydroxide SODHYD-F/OID121 Strontium chromate An/ as STRCHR-F/I Strontium and Chrorruum Strychnine STRYCHNINE-M/N5016 Styrene STYRENE-M/09 Sulfur dioxide SULDIO-M/OID200 T T erp enes TERPENES-M/ N 1552 Armstrong Forensic Laboratory, Inc August 31, 2023 Method Dept Media Pricing NIOSH 1301 FID 226-01 $155.00 Each NIOSH 2O00 FID 226-51 $125.00 Each NIOSH 1451 FID 226-01 $125.00 Each NIOSH 1458 FID 226-01 $125.00 Each NIOSH 1459 FID 226-01 $125.00 Each NIOSH 1611 FID 226-01 $125.00 Each NIOSH 2520 FID 226-30-02 $175.00 Each NIOSH 1451 FID 226-01 $125.00 Each NIOSH 1001 FID 226-01 $125.00 Each OSHA55 LC/IC 226-98 $125.00 Each NIOSH 1404 FID 226-01 $125.00 Each NIOSH 2521 FID 226-115 $125.00 Each 3M OVM FID 3M 3520 $125.00 Each NIOSH 1005 FID 226-01 $125.00 Each NIOSH 5029 LC/IC Tr GEE $175.00 Each NIOSH 3508 WC Imp Solution $85.00 Each NIOSH 1014 FID 226-01 $125.00 Each 3M OVM FID 3M 3500 $125.00 Each NIOSH 2537 FID 226-30-06 $125.00 Each NIOSH 1300 FID 226-01 $125.00 Each 3M OVM FID 3M 3500 $125.00 Each NIOSH 1615 FID 226-01 $125.00 Each OSHA48 FID 226-01 $125.00 Each NIOSH 3511 FID Imp Solution $125.00 Each NIOSH 2551 MS 226-93 $175.00 Each OSHA ID 182 LC/IC 226-40 back $95.00 Each OSHA ID 182 LC/IC 226-40 Set $95.00 Each NIOSH 2526 FID 226-3002A $125.00 Each OSHA ID 182 LC/IC 226-40 front $95.00 Each NIOSH 2527 FID 226-111A $125.00 Each NIOSH 5506 LC/IC 22630-04 $200.00 Each NIOSH 5515 MS 226-30-04 $175.00 Each NIOSH5026 FTIR CEF37mm $95.00 Each OSHA ID214 LC/IC Tr Filter $95.00 Each No Method MIC CEF25mm $95.00 Each NIOSH 2546 FID 226-95 $125.00 Each OSHA32 LC/IC 226-95 $125.00 Each OSHA ID 180 LC/IC 226-80 $175.00 Each OSHA ID 111 LC/IC CEF37mm $95.00 Each NIOSH 5503 ECD GFF&Florisil $85.00 Each OSHA ID121 METAL Filter $55.00 Each NIOSH 1613 FID 226-01 $125.00 Each OSHA ID 121 METAL Filter $55.00 Each NIOSH 7300 METAL CEF37mm $75.00 Each NIOSH 5016 LC/IC Filter $195.00 Each OSHA9 FID 226-01 $125.00 Each OSHA ID 200 LC/IC 226-80 $145.00 Each NIOSH 1552 FID 226-01 $125.00 Each Page C3 of 4 Vendor Services Agreement - Armstrong Forensic Laboratory, Inc. Page 39 of 63 Alphabetical List of Analytes Test Name Test Code Method Dept Media Tetraethyl pyrophosphate TETETHPYRPHOSPHATE-M/N2504 NIOSH 2504 FID 226-105 Tetrahydrofuran TETHYDFURAN-M/N1609 NIOSH 1609 FID 226-01 Toluene TOLUENE-3M 3M OVM/GC- FID 3M 3500 FID Toluene TOLUENE-OVM/O111 OSHA111 FID 226-91 Total suspended particulates PM10-8X10" 40 CFR Part 50 GRAV GFF Tared 8x10 App B Total suspended particulates TSP-8X10" 40 CFR Part 50 GRAV GFF Tared 8x10 App B Toxaphene TOXAPHENE-M/N5039 NIOSH 5039 ECD CEF37mm Trichloroethene TRICHLETHENE-M/N1022 NIOSH 1022 FID 226-01 Trimethylbenzene TRIMET13EN-M/OPV2091 OSHAPV2091 FID 226-01 Turpentine TURPENTINE-M/N1551 NIOSH1551 FID 226-01 Total Volatile Organic TVOC(C15)-PD/3M 3M OVM FID 3M 3500 Compounds V Vinyl bromide VINBROMIDE-M/N1009 NIOSH 1009 FID 226-09 Vinyl chloride VINCHLORIDE-M/N1007 NIOSH 1007 FID 226-01 Vinylidene chloride VINYLIDENE CHLORIDE-M/N1015 NIOSH 1015 FID 226-01 W Warfarin WARFARIN-M/N5002 NIOSH 5002 LC/IC PTFE Armstrong Forensic Laboratory, Inc August 31, 2023 Pricing $125.00 Each $125.00 Each $125.00 Each $125.00 Each $90.00 Each $90.00 Each $125.00 Each $125.00 Each $90.00 Each $125.00 Each $125.00 Each $190.00 Each $190.00 Each $190.00 Each $195.00 Each Page C4 of 4 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 40 of 63 Microbial Services Prices are outlined in the following groups: Air Bulk Surface Coliforms Liquid Armstrong Forensic Laboratory, Inc August 31, 2023 Section D Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 41 of 63 Test Name Air Bioaerosols Cellulose Plate Total Count and ID A RT MEA Plate Colony Count and ID A ET PDA Plate Total Count and ID A RT TSA Plate Colony Count and ID A RT TSA Plate Colony Count and ID 9 ET Bulk Microscopical Exam and Fungi ID Cellulose Plate Total Count and ID 9 RT MEA Plate Total Count and ID 9 RT MEA Plate Total Count and ID 9 ET PDA Plate Total Count and ID A RT TSA Plate Colony Count and ID A RT TSA Plate Colony Count and ID A ET Surface Microscopical Exam and Fungi ID Cellulose Plate Total Count and ID 9 RT MEA Plate Total Count and ID 9 ET PDA Plate Total Count and ID A RT TSA Plate Colony Count and ID A RT TSA Plate Colony Count and ID A ET Coliforms Fecal cohforms Total coliforms Liquid Heterotrophic Plate Count Microbial Services Test Code Method Dept Media Pricing BIOAEROSOLS AFL -SOP 3.01.101 BIO Air-O-Cell $70.00 Each CELL ART-P C/C AFL -SOP 3.01.102 BIO Cellulose Plate $90.00 Each MEA (HT-P (C/C) AFL -SOP 3.01.111 BIO MEA Plate $90.00 Each PDA ART-P (C/C) AFL -SOP 3.01.111 BIO PDA Plate $90.00 Each TSA ART-P C/C AFL -SOP 3.01.107 BIO Cellulose Plate $90.00 Each TSA AET-P C/C AFL -SOP 3.01.107 BIO TSA Plate $90.00 Each MICROMOLD-BULK AFL -SOP 3.01.103 BIO Bulk $70.00 Each CELL 9RT-B C/C AFL -SOP 3.02.008 BIO Bulk $90.00 Each MEA ART-B (C/C) AFL -SOP 3.02.008 BIO Bulk $90.00 Each MEA AET-B (C/C) AFL -SOP 3.02.008 BIO Bulk $90.00 Each PDA ART-B (C/C) AFL -SOP 3.02.008 BIO Bulk $90.00 Each TSA ART-B C/C AFL -SOP 3.02.008 BIO Bulk $90.00 Each TSA AET-B C/C AFL -SOP 3.01.107 BIO Bulk $90.00 Each MICROMOLD-TAPE AFL -SOP 3.01.103 BIO Tape Transfer $70.00 Each CELL 9RT-SB C/C AFL -SOP 3.02.009 BIO Swab $90.00 Each MEA 9ET-SB (C/C) AFL -SOP 3.02.009 BIO Swab $90.00 Each PDA ART-SB (C/C) AFL -SOP 3.02.009 BIO Swab $90.00 Each TSA ART-SB C/C AFL -SOP 3.02.009 BIO Swab $90.00 Each TSA AET-SB C/C AFL -SOP 3.02.009 BIO Swab $90.00 Each COL,FECAL-W/APHA9222D APHA 9222D BIO Varies $75.00 Each COL,TOTAL-W/APHA922213 APHA 9222B BIO Varies $75.00 Each HETPLTCNT APHA 9215 BIO Liquid $70.00 Each Notes (1) Minimum TAT for cultured samples is 9 calendar days. Certain genera and/or species may require extended growth periods. Please contact the laboratory for specific needs. Room and Elevated incubation temperatures available. (2) Standard microbiological agar medias are utilized by the laboratory including malt extract agar (MEA); Cellulose (CEL), Potato Dextrose (PDA); Tryptone soy (TSA); and Blood Agar. Contact the laboratory for the appropriate media for your specific needs. Armstrong Forensic Laboratory, Inc Page DI of 1 August 31, 2023 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 42 of 63 Environmental Services Analytical Group Listing Prices are outlined in the following groups: Anions Cations Closed Loop Stripping Coliforms Extractions Inorganics - General Metals - Group Metals - Individual Organics - General Organics - Screens Armstrong Forensic Laboratory, Inc August 31, 2023 Section E Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 43 of 63 Environmental Services, Analytical Group Listing Test Name Test Code Method Dept Media Pricing Anions Anions ANIONSS/E300 EPA300 LC/IC Solid $195.00 TAL $125.00 First Analyte $95.00 Additional Analyte Anions ANIONSW/E300 EPA300 LC/IC Liquid $195.00 TAL $125.00 First Analyte $95.00 Additional Analyte Anions ANIONS WIPE/ E300 EPA300 LC/IC Wipe $195.00 TAL $125.00 First Analyte $95.00 Additional Analyte Nitrogen analyzed as Nitrate NITROGEN-W/E300 EPA300 LC/IC Liquid $90.00 TAL & Nitrite by EPA 300 Sulfate SULFATE-S/E300 EPA300 LC/IC Solid $125.00 Each Sulfate SULFATE-S/E9038 EPA 9038 WC Solid $75.00 Each Sulfate SULFATE-S/TXDOT145E TXDOT 145E WC Solid $75.00 Each Cations Cations CATIONS-S/ASTM D6919 ASTM D6919 LC/IC Solid $195.00 PAL $125.00 First Analyte $95.00 Additional Analyte Cations CATIONS-W/ASTM D6919 ASTM D6919 LC/IC Liquid $195.00 TAL $125.00 First Analyte $95.00 Additional Analyte Cations CATIONS-WIPE/ASTM D6919 ASTM D6919 LC/IC Wipe $195.00 TAL $125.00 First Analyte $95.00 Additional Analyte Closed Loop Stripping Geosmin GEOSMIN-W/APHA 6040B APHA 6040B MS Liquid $375.00 Each Coliforin5 Fecal coliforms COL,FECAL-W/APHA9222D APHA9222D BIO Varies $75.00 Each Total coliforms COL,TOTAL-W/APHA9222B APHA9222B BIO Varies $75.00 Each Extractions Non Volatile SPLP Extraction SPLP-NV-MET for Metals Armstrong Forensic Laboratory, Inc August 31, 2023 EPA 1312 METAL Solid $60.00 Each Page El of 8 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 44 of 63 Environmental Services, Analytical Group Listing Test Name Test Code Method Dept Media Pricing Non Volatile TCLP Extraction TCLP-NV-ECD EPA 1311 ECD Solid $60.00 Each for ECD Non Volatile TCLP Extraction TCLP-NV-MET EPA 1311 METAL Solid $60.00 Each for Metals Non Volatile TCLP Extraction TCLP-NV-MS EPA 1311 MS Solid $60.00 Each for Mass Spec Volatile TCLP Extraction for TCLP-VMS EPA 1311 MS Solid $70.00 Each Mass Spec Volatile TCLP Extraction for TCLP-V-PID EPA 1311 PID Solid $70.00 Each PID Inorganics - General Alkalis ty ALKALINITY-W/APHA232013 APHA2320B WC Liquid $50.00 Each Total acidity ACIDITY-W/APHA2310 APHA2310 WC Liquid $50.00 Each Alkalinity ALKALINITY-W/AQ1-EPA102 AQ1-EPA 102 WC Liquid $50.00 Each Ammonia AMMONIA-W/E350.2 EPA 350.1 WC Liquid $65.00 Each Biochemical Oxygen Demand BOD-W/APHA5210B APHA 5210B WC Liquid $55.00 Each Carbonaceous Biochemical C13OD-W/APHA521013 APHA 5210B WC Liquid $60.00 Each Oxygen Demand Residual chlorine CHLRES-W APHA 4500-Cl G WC Liquid $65.00 Each Free Chlorine CHLFREE-W/HACH8021 HACH8021 WC Liquid $65.00 Each Total Residual Chlorine CHLTOTRES-W/HACH8167 HACH 8167 WC Liquid $65.00 Each Armstrong Forensic Laboratory, Inc Page E2 of 8 August 31, 2023 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 45 of 63 Environmental Services, Analytical Group Listing Test Name Test Code Method Dept Media Pric[ng Chemical Oxygen Demand COD-W/EPA410.4 EPA 410.4 via WC Liquid $50.00 Each Hach Specific Conductrvity CONDUCTIVITY/EPA9050 EPA 9050A WC Solid/Ligmd $30.00 Each Corrosivity PH-W/4500H+B APHA4500H+B WC Liquid $30.00 Each Cyamde, Amenable CYANIDE,AMEN-W/4500CN- APHA4500CN- WC Liquid $130.00 Each C/E Cyanide, Total CYANIDE,TOTAL-W/4500CN- APHA4500CN- WC Liquid $130.00 Each C/E Cyanide, Total CYANIDE,TOTAL-W/E335.2 EPA335.2 WC Liquid $170.00 Each Cyanide, Reactive CYANIDE,REACTIVE EPA Chapter 7, WC Liquid $95.00 Each EPA 335.2 Flashpoint, Closed Cup, Amb FLAPT-CC-140 ASTM D93 WC Liquid to 140 F Flashpomt, Closed Cup, FLAPT-CC-FLASH ASTM D93 WC Liquid Subambient to Flash Flashpomt, Open Cup, Amb FLAPT-OC-140 ASTM D92 WC Solid to 140 F Flashpomt, Open Cup, FLAPT-OC-FLASH ASTM D92 WC Solid Subambient to Flash Hardness HARD-CALC 2OF2 APHA 2340 B METAL Liquid Hexavalent Chronuum HEXCHR-W/APHA3500-CRB APHA3500-CrB WC Liquid Iodine Number IODINE NUMBER ASTM D1959 WC Liquid Armstrong Forensic Laboratory, Inc August 31, 2023 $75.00 Each $175.00 Each $75.00 Each $175.00 Each $75.00 Each $75.00 Each $245.00 Each Page E3 of 8 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 46 of 63 Environmental Services, Analytical Group Listing Test Name Test Code Method Dept Media Pricing Methylene Blue Active MBASW/E425.1 EPA 425.1 WC Liquid $145.00 Each Substances Methylene Blue Active MBASW/APHA5540C APHA 5540C WC Liquid $145.00 Each Substances Odor ODOR/APHA2150 APHA2150B WC Liquid $195.00 Each Punt Filter Test PAINTFILTERTEST/EPA9095B EPA 9095B WC Vanes $95.00 Each Percent Moisture PERCENTMOIST ASTM D2974A WC Solid $50.00 Each Percent Solids PERCENTSOLIDS ASTM D2974A WC Solid $50.00 Each Phosphorous, Total PH OSPH, TOT-W/E365.2 EPA365 WC Liquid $75.00 Each Phosphorous, Dissolved PHOSPH,DISS-W APHA 4500-P E WC Liquid $75.00 Each Phosphorous, Total PHOSPH,TOT-W APHA4500-P B, E WC Liquid $75.00 Each Reactivity, Corrosivity, RCl/SW846,C7 EPA Chapter? WC Solid/Liquid $225.00 Each Igratabihty Reactivity REACTIVITY EPA Chapter 7 WC Solid $95.00 Each Taste TASTE/APHA2160 APHA2160 WC Liquid $95.00 Each Total Dissolved Solids TDSW/APHA2540C APHA 2540 C GRAV Liquid $55.00 Each (Res, Solids) Total Dissolved Solids TDSW/E160.1 EPA 160.1 GRAV Liquid $55.00 Each (Res, Solids) Total Kjeldahl Nitrogen TKN-OSS/APHA4500BF APHA4500BF OSS Liquid $195.00 Each Armstrong Forensic Laboratory, Inc Page E4 of 8 August 31, 2023 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 47 of 63 Environmental Services, Analytical Group Listing Test Name Test Code Method Dept Media Pricing Total Organic Carbon TOC-W EPA415.1 OSS Liquid $195.00 Each Total Organic Halides TOX-W/E9056 EPA 9056 LC/IC Liquid $195.00 Each Trihalomethane TRIHALO-W/E8260 EPA 8260 MS Liquid $150.00 Each Total Suspended Solids TSS-W/APHA2540D APHA 2540D WC Liquid $55.00 Each (Res, Total) Total Suspended Solids TSS-W/E160.2 EPA 160.1 WC Liquid $55.00 Each (Res, Total) Total Solids TS-W/EPA160.3 EPA 160.3 GRAV Liquid $55.00 Each Total Solids TS-W/APHA2540B APHA2540B GRAV Liquid $55.00 Each Turbidity TURBIDITY APHA 2130B WC Liquid $55.00 Each Total Volatile Solids TVS EPA 160.4 GRAV Solid $55.00 Each Volatile Suspended Solids VSS-W/APHA2540E APHA2540E GRAV Liquid $55.00 Each Metals - Group Metals List 1 (RCRA 8) SPECIFIC TO ANALYTE EPA 6010/200.7 & METAL Solid/Lrgmd $175.00 Each 7470/ 7471/245.1 Metals List 2 (Priority SPECIFIC TO ANALYTE EPA 6010/200.7 & METAL Solid/Lrgmd $195.00 Each Pollutants) 7470/ 7471/245.1 Metals List 3 (20 Metal Screen) SPECIFIC TO ANALYTE EPA 6010/200.7 & METAL Solid/Lrgmd $295.00 Each 7470/7471/245.1 Special Metals Preparation MET-SPECPREP METAL Solid/Liquid $60.00 Each Armstrong Forensic Laboratory, Inc August 31, 2023 Page E5 of 8 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 48 of 63 Environmental Services, Analytical Group Listing Test Name Test Code Method Dept Media Pricing Metals - Individual Inductively Coupled Plasma SPECIFIC TO ANALYTE EPA 6010 or EPA METAL Solid/Liquid (ICP) 200.7 $45.00 First Analyte $30.00 Additional Analyte Flame Atomic Absorption SPECIFIC TO ANALYTE EPA 7000 Series or METAL Solid/Liquid (FAA) EPA 200 Series $45.00 First Analyte $30.00 Additional Analyte Cadmium CADMIUM, LEACH-S/AOAC AOAC 973.32 METAL Solid $90.00 Each Leachable Lead LEAD, LEACH-S/AOAC AOAC 973.32 METAL Solid $95.00 Each Lead LEAD-S/E6010 EPA 6010C METAL Solid $45.00 Each Lead LEAD-S/E7000 EPA 7000 METAL Solid $45.00 Each Mercury MERCURY-S/E7471 EPA 7471B METAL Solid $60.00 Each Mercury MERCURY-SPLP/E7470 EPA 7470A METAL Solid/Liquid $60.00 Each Mercury MERCURY-TCLP/E7470 EPA 7471 METAL Solid/Liquid $60.00 Each Mercury MERCURY-W1D/E7470 EPA 7470A METAL Liquid $60.00 Each Mercury MERCURY-WIT/E7470 EPA 7470A METAL Liquid $60.00 Each Mercury MERCURY-W2D/E245 EPA 245.1 METAL Liquid $60.00 Each Mercury MERCURY-W2T/E245 EPA 245.1 METAL Liquid $60.00 Each Organics - General Acetone ACETONE-W ASTM D3695 FID Liquid $75.00 Each Alcohols & Ketones ALC&KET-W ASTM D3695 FID Liquid $75.00 First Analyte $30.00 Additional Analyte Armstrong Forensic Laboratory, Inc Page E6 of 8 August 31, 2023 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 49 of 63 Environmental Services, Analytical Group Listing Test Name Test Code Method Dept Media Prid g Ethylene Glycol ETHGLYCOL-W/D2908 ASTM D2908-91 FID Liquid $75.00 Each Hexane Extractable Material O&G-W/E1664 EPA 1664 WC Liquid $130.00 Each Hexane Extractable Material O&G-W/E1664 (SGT) EPA 1664 WC Liquid $160.00 Each (SGT) Toxaphme TOXAPHENE-W/E8081 EPA 8081B ECD Liquid $175.00 Each TPH TPH-S/TCEQ1005 TCEQ TX 1005 TPH Solid $95.00 Each TPH TPH-S/TCEQ1006 TCEQ TX 1006 OSS Solid $350.00 Each TPH TPH-W/TCEQ1005 TCEQ TX 1005 TPH Liquid $95.00 Each TPH TPH-W/TCEQ1006 TCEQ TX 1006 TPH Liquid $350.00 Each Trihalomethanes TRIHALO-W/E624.1 EPA 624.1 MS Liquid $195.00 Each Organics - Screens Polychlorinated biphenyls PCB -OIL EPA 8082A ECD Off $105.00 Each Polychlorinated biphenyls PCB-P/DOD EPA 8082A ECD Paint $115.00 Each with DOD Toluene Ext. Polychlorinated biphenyls PCB-S/DOD EPA 8082A ECD Solid $115.00 Each with DOD Toluene Ext. Polychlorinated biphenyls PCB-S/E8082 EPA 8082A ECD Solid $115.00 Each Polychlorinated biphenyls PCB-W/E608 EPA 608 ECD Liquid $115.00 Each Polychlorinated biphenyls PCB-W/E8082 EPA 8082A ECD Liquid $115.00 Each Armstrong Forensic Laboratory, Inc Page E7 of 8 August 31, 2023 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 50 of 63 Environmental Services, Analytical Group Listing Test Name Test Code Method Dept Media Prid g Pesticides, Chlorinated PEST,CHLOR-S/E8081 EPA 8081B ECD Solid $245.00 TAL $145.00 First Analyte $60.00 Additional Analyte Pesticides, Chlorinated PEST,CHLOR-W/8081 EPA 8081B ECD Liquid $245.00 TAL $145.00 First Analyte $60.00 Additional Analyte Pesticides, Phosphate PEST, PHOS-S/EPA8141A EPA 8141A MS Solid $265.00 TAL $165.00 First Analyte $60.00 Additional Analyte Pesticides, Phosphate PEST, PHOS-W/EPA8141A EPA 8141A MS Solid $265.00 TAL $145.00 First Analyte $60.00 Additional Analyte Polynuclear aromatic PNA-W/E8270 EPA 8270 MS Liquid $245.00 TAL hydrocarbons $165.00 First Analyte $60.00 Additional Analyte Polynuclear aromatic PNA-W/E8310 EPA 8310 LC/IC Liquid $315.00 TAL hydrocarbons $165.00 First Analyte $90.00 Additional Analyte Semi -Volatile Organic SVOC-S/E8270 EPA 9270 MS Solid $245.00 TAL Compounds $165.00 First Analyte $60.00 Additional Analyte Semi -Volatile Organic SVOC-W/E625 EPA625 MS Liquid $295.00 TAL Compounds $195.00 First Analyte $60.00 Additional Analyte Sena -Volatile Organic SVOC-W/E8270 EPA8270 MS Liquid $245.00 TAL Compounds $165.00 First Analyte $60.00 Additional Analyte Volatile Organic Compounds VOC-S/E8260 EPA 8260 MS Solid $195.00 TAL $145.00 First Analyte $50.00 Additional Analyte Volatile Organic Compounds VOC-W/E624.1 EPA 624.1 MS Liquid $195.00 TAL $145.00 First Analyte $50.00 Additional Analyte Volatile Orgamc Compounds VOC-W/E8260 EPA 8260 MS Liquid $195.00 TAL $145.00 First Analyte $50.00 Additional Analyte Armstrong Forensic Laboratory, Inc August 31, 2023 Page E8 of 8 Vendor Services Agreement - Armstrong Forensic Laboratory, Inc. Page 51 of 63 Environmental Services, Analytical Group Listing Test Name Method Alcohols & Ketones ASTM D3695 Acetone Amyl alcohol Ethanol 1-Hexanol Isopropyl alcohol Methanol Methyl amyl alcohol n-Octanol 2-Pentanol n-Propenol sec -Butyl alcohol Anions EPA 300 Bromide Chloride Nitrate Nitrite Phosphate Sulfate Cations ASTM D6919 Ammom at Calcium Lithium Magnesium Potassium Sodium Metals List 1 (RCRA 8) EPA 6010/200.7 Arsenic Barium Cadmium Chromium Lead Mercury Selenium Silver Metals List 2 (Priority Pollutants) EPA 6010/200.7 Antimony Aisemc Berylhum Cadmium Chromium Copper Lead Mercury Nickel Selenium Silver Thallium Zinc Metals List 3 (20 Metal Screen) EPA 6010/200.7 Aluminum Antimony Arsenic Barium Beryllium Cadmium Chromium Cobalt Copper Iron Lead Manganese Molybdenum Nickel Selenium Silver Thallium Titamum Vanadium Zinc Pesticides, Chlorinated EPA8081B Aldrin alpha-BHC beta-BHC delta-BHC gamma-BHC alpha -Chlordane gamma -Chlordane Chlordane, Technical 4,4'-DDD 4,4'-DDE 4,4'-DDT Dieldnn Endosulfan I Endo sulfan II Endosulfan sulfate Endrin Endrin aldehyde Endrin ketone Heptachlor Heptachlor epoxide Methoxychlor Decachlorobiphenyl 2,4,5,6-Tetrach1om-m-xylene Pesticides, Phosphate EPA8141A Azinphos methyl Chlorpyrifos Diazinon Dichlorvos Disulfoton Ethoprop Ethyl parathion Malathion Methyl parathion Mevinphos Tetmchlorvinphos Tetraethyl pyrophosphate Polynuclear aromatic EPA8270 hydrocarbons Acenaphthene Acenaphthylene Anthracene Benzo(a)anthracene Benzo(b)fluoranthene Benzo(k)fluormthme Benzo(g,h,i)perylene Benzo(a)pyrene Chrysene Dibenz(a,h)anthracene Fluoranthene Fluorene Indeno(1,2,3-cd)pyrene Naphthalene Phenanthrene Pyrene Nitrobenzene-d5 2-Fluorobiphenyl 4-Terphen7l-d14 Polynuclear aromatic EPA8310 hydrocarbons Acenaphthene Acenaphthylene Anthracene Benzo(a)anthracene Benzo(b)fluoranthene Benzo(k)fluormthme Benzo(g,h,i)perylene Bmzo(a)pyrme Chrysene Dibenz(a,h)anthracene Fluoranthene Fluorene Indeno(1,2,3-cd)pyrene Naphthalene Phenanthrene Pyrene Semi -Volatile Organic EPA 625 Compounds Acenaphthene Acenaphthylene Anthracene Benzidme Benzo(a)anthracene Benzo(a)pyrene Armstrong Forensic Laboratory, Inc August 31, 2023 Page El of 3 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 52 of 63 Environmental Services, Analytical Group Listing Test Name Method Benzo(b)fluoranthene Benzo(g,hf)perylene Benzo(k)fluoranthene Bis(2-chloroethoxy)methane Bis(2-chloroethyl)ether Bis(2-ethylhexyl) phthalate Bis(2-chloroisopropyl) ether 4-Brorrophenyl phenyl ether Butyl benzyl phthalate Carbazole 4-Chlomaniline 4-Chloro-3-methylphmol 2-Chloronaphthalme 2-Chlorophenol 4-Chlorophenyl phenyl ether Chrysene Dibmz(a,h)anthracene Dibenzofman 1,2-Dichlorobenzene 1,3-Dichlorobenzene 1,4-Ds1dorobenzene 3,3'-Dichlorobenzidine 2,4-Dichlorophenol Diethyl phthalate 2,4-Dimethylphmol Dunethyl phthalate Di-n-butyl phthalate 4,6-Dinitro-2-methylphmol 2,4-Dinitmphenol 2,4-1)autrotoluene 2,6-Dinitrotoluene Di-n octyl phthalate 1,2-Dipheny1hydrazme (azobenzene) Fluoranthene Fluorene Hexachlorobenzene Hexachlorobutadiene Hexachlorocyclopentadiene Hexachloroethane Indeno(1,2,3-cd)pyrene Isophorone 2-Methyl naphthalene 2-Methylphenol 4-Methylphenol Naphthalene 2-Nitroaniline 3-Nitroamhne 4-Nitroanfline Nitrobenzene 2-Nitrophenol 4-Nitrophenol N-Nitrosod-thylamine N-Nitrosodi-n-propylarmne N-Nitrosodiphenylamine Pentachlorophenol Phenanthrene Phenol Pyrene Pyridine 1,44-Trichlorobenzene 2,4,5-Tnchlomphenol 2,4,6-TricMorophenol 2-Fluorophenol Phenol-d6 2,4,6-Tribromophmol Nitrobenzene-d5 2-Fluorobiphenyl 4-Terphenyl-d14 1,4-Dichlorobmzme-d4 Naphthalene-d8 Acenaphthene-d10 Phenanthrene-d10 Chrysene-d12 Perylene-d12 Semi -Volatile Organic EPA 8270 Compounds Acenaphthene Acenaphthylene Anthracene Bmzidine Bmzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(g,hj)perylene Benzo(k)fluoranthene Bis(2-chlomethoxy)methane Bn(2chloroethyl)ether Bis(2-ethylhexyl)phthalate Bis(2-chlomisopropyl) ether 4-Bromophenyl phenyl ether Butyl benzyl phthalate Carbazole 4-Chloroaniline 4-Chloro-3-methylphmol 2-Chloronaphthalme 2-Chlorophenol 4-Chlorophenyl phenyl ether Chrysene Dibenz(a,h)anthracene Dibenzofuran 1,2-Dichlorobenzene 1,3-Dichlorobenzene 1,4-Dichlorobmzme 3,3'-Dichlorobenzidine 2,4-Dichlorophenol Diethyl phthalate 2,4-Dimethylphenol Dimethyl phthalate Di-n-butyl phthalate 4,6-Dinftro-2-methylphenol 2,4-Dinitrophenol 2,4-Dinitrotoluene 46-Dinitrotoluene Di-moctyl phthalate 1,2-Diphmylhydrazme (azobenzene) Huoranthene Fluorene Hexachlorobenzene Hexachlorobutadiene Hexachlorocyclopentadiene Hexachloroethane Indeno(1,2,3-cd)pyrene Isophorone 2-Methyl naphthalene 2-Methyl phenol 4-Methyl phenol Naphthalene 2-Nitroanilme 3-Nitroamline 4-Nitroamlme Nitrobenzene 2-Nitrophenol 4-Nitrophenol N-nitrosodimethylamine N-Nitrosodi-n-propylamine N-Nitrosodiphenylamine Pentachlorophenol Phenanthrene Phenol Pyrene Pyridine 1,2,4-Tnchlorobmzme 2,4,5-Trichlorophenol 2,4,6-TricMorophenol 2-Fluorophenol Phenol-d6 24,6-Tribromophmol Nitrobenzene-d5 2-Fluorobiphenyl 4-Terphenyl-d14 1,4-Ds1dorobenzene-d4 Naphthalene-d8 Acenaphthene-d10 Phenanthrene-d10 Chrysene-dl2 Perylene-d12 Special Metals Preparation Speciahzed Digestion Volatile Organic Compounds EPA 624.1 Benzene Bromodichloromethme Bromoform Bromomethane Carbon tetrachloride Chlorobenzene Chloroethane 2-Chlomethylvinyl ether Chloroform Chloromethane Dibromochlommethane 1,2-Dichlorobenzene 1,3-Dichlombenzene 1,4-Dichlorobenzene 1,1-Dshloroethane 1,2-Dichloroethane 1,1-Dichlomethene cis-1,2-Dichloroethene trans-1,2-Dichloroethme 1,2-Dichloropropane cis-1,3-Dichloropropene trans-1,3-Dichloropropene Ethylbenzene Methylene chloride Armstrong Forensic Laboratory, Inc Page E2 of 3 August 31, 2023 Vendor Services Agreement - Armstrong Forensic Laboratory, Inc. Page 53 of 63 Environmental Services, Analytical Group Listing Test Name Method Methyl ethyl ketone T oluene Tnchloroethene m&p-Xylene Dibromofluoromethane 1,4-Dichlorobenzene-d4 Volatile Organic Compounds EPA 8260 Benzene Bromomethane Chloroethane Chloromethane 1,3-Dichlombenzene 1,2-Dichlomethane trans-1,2-Dichloro ethene trans-1,3-Dichloropropene Methyl ethyl ketone T olnene Tnchloroethene m&p-Xylene Dibromofluoromethane Chlorobenzene-d5 Armstrong Forensic Laboratory, Inc August 31, 2023 1,1,2,2-Tetrachloroethane Tetrachloroethene 1,1,1-Trichloroethane 1,1,2-Tiichloroethane Tnchlorofluoromethane Vinyl chloride o-Xylene 4-Bromofluombenzene Toluene-d8 Cllorobenzene-d5 Fluorobenzene Bromodichloromethane Bromofonn Carbon tetrachloride Chlorobenzene 2-Chloroethylvinyl ether Chloroform Dibromochloromethane 1,2-Dichlorobenzene 1,4-Dichlorobenzene 1,1-Dshloroethane 1,1-Dichloroethene cis-1,2-1)ichloroethene 1,2-Dichloropropane cis-1,3-Dichlompropene Ethyl benzene Methylene chloride 1,1,2,2-Tetrachloroethane Tetrachloroethene 1,1,1-Trichloroethane 1,1,2-Trichloroethane Tnchlorofluoromethane Vinyl chloride o-Xylene 4-Bromofluombenzene Toluene-d8 Fluorobenzene 1,4-Dichlombenzene-d4 Page E3 of 3 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 54 of 63 Forensic Testing and Consulting Services Prices are outlined in the following groups: Recovery & Identification of Ignitable Liquids Fluid Analysis Trace Evidence Additional Services Explosive Gases Evidence Collection Evidence Disposition Services Armstrong Forensic Laboratory, Inc August 31, 2023 Section F Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 55 of 63 Forensic Testing -Consulting Services Test Name Recovery St Identification of Ignitable Liquids Ignitable Liquids Prep for Ignitable Liquids (Per Case) Fluid Analysis Brake Fluid Crossmatch, Hydrocarbons ("fingerprinting") Fuel Contamination DEF Contamination Coolant Gas Chromatograph ID (High Temperature) Gas Chmmatogmph/Mass Spectrometer ID (GC/MS) Water Content by FTIR Sugar Analysis Engine Oil (Wear Metals) Engine Oil (Sugar, Water, Glycol, FTIR, etc.) Transmission Fluid ( Wear Metals) Transmission Fluid (Water, FTIR, physical exam) Trace Evidence Blood Alcohol Content Blood, Presence of Drug Screen Analysis for Presence Drug Screen Analysis for Quantitation Forensic Examination Forensic Microscopy Saliva, Presence of Semen, Presence of Wax by GC TCEQ 1005 Additional Services Chamber Test Setup/Burn Cellulose Insulation Evaluation Energy Dispersive X-Ray Analysis FAME Fire Point & Smoke Point Foreign & Regulated Domestic Soil Surcharges FTIR for Identification Microscopic Photographs Oxidizers (spot test) Paint Examination/ Comparison (First Sample) Paint Examination/ Comparison (Additional Sample) Photographic Documentation Solvent Extraction Spontaneous Combustion Evaluation Vertical Burn Test X-Ray XRD Analysis Explosive Gases Natural Gas Analysis Evidence Collection Fire Debns Collection Kit 1 Gallon Fire Debris Cans (4 Pack) 1 Gallon Fire Debris Cans (12 Pack) Vehicle Fluid Collection Kit Paint Transfer Collection Kit Evidence Disposition Seances Storage (6 Months) per case Armstrong Forensic Laboratory, Inc August 31, 2023 Test Code Media Pricing FIRE/ASTM1618 Debris $115.00 FIRE PREP Debris $50.00 BRAKEFLUID Liquid $285.00 CROSSMATCH Organic $500.00 FUELDESC/AFL Fuel $285.00 DEFDESC/AFL Fluid $285.00 COOLANT Liquid $265.00 GC -FIRE FID Varies $285.00 GCMS Varies $350.00 WATCON/FTIR Liquid $195.00 SUGAR Liquid $85.00 WM OIL lOF2 Oil $85.00 WM OIL 2O172 Oil $85.00 WM TRANS 10172 Fluid $85.00 WM TRANS 2O172 Fluid $85.00 BLALCONTENT/AFL Liquid $190.00 BLOOD, PRESENCE Varies $260.00 DRUGSCREEN/AFL Varies $260.00 DRUGSCREEN/PURITY Vanes $260.00 FORENSIC -EXAM Vanes $395.00 MICRO -FORENSIC Varies $165.00 SALIVA Vanes $260.00 SEMEN, PRESENCE Vanes $260.00 WAX/GCFID Solid $235.00 CHAMBERTEST Varies $750.00 Insulation $950.00 EDAX Vanes $375.00 FAME2OF3 Debris $350.00 FIREPT-OPEN CUP Vanes $750.00 Solid $50.00 FTIR Varies $195.00 MIC-PHOTO Varies $60.00 OXIDIZERS (SPOT TEST) Solid $150.00 Paint $375.00 Paint $250.00 PHOTOS Vanes $85.00 Varies $110.00 Vanes $950.00 VERTBURN/UL94V Vanes $395.00 XRAY Varies $150.00 XRD Vanes $350.00 NATGAS/FID Air $175.00 K-FIREDEBRLSKIT Varies $40.00 K-GALLONCANBOX Varies $40.00 K-GALLONCANSTACK Vanes $110.00 K-VEHICLEFLUID Vanes $25.00 K-PAINTTRANSFER Varies $25.00 Evidence $75.00 Page IT of 2 Vendor Services Agreement - Armstrong Forensic Laboratory, Inc. Page 56 of 63 Forensic Testing -Consulting Services Test Name Test Code Media Pricing Storage (1 Year) per case Evidence $150.00 Storage (3 Years) per case Evidence $350.00 Storage, Dangerous (6 Months) per case Evidence $500.00 Storage, Oversized (6 Months) per case Evidence $300.00 Storage, Orls (4 Years) per case Evidence $50.00 Sample Handlmg & Return per case Evidence $60.00 Armstrong Forensic Laboratory, Inc August 31, 2023 Page F2 of 2 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 57 of 63 Sampling Media Prices are outlined in the following groups: Sorbent Tubes Filters Passive Monitors Sealed Containers Armstrong Forensic Laboratory, Inc August 31, 2023 Section G Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 58 of 63 Test Name SorbentTubes Charcoal Tube (50/100) Silca Gel (75/150) Mercury Tubes (200) XAD-2 (50/100) XAD-2 (200/400) Tenax (50/100) OVS, Quartz Fiber Filter/XAD-2 (140/270) XAD-7, Treated (40/80) Low Sulfur Carbon DNPH Silica Gel Filters Treated Nitrocellulose Filters (SKC 225-9031) Treated Quartz Fiber Filters (SKC 225-9032) Quartz Fiber Filters (SKC 225-9033) Air-O-Cell Cassette Mixed Cellulose Ester, 25mm Mixed Cellulose Ester, 37mm Mixed Cellulose Ester, 37mm (Matched Wt.) +/- 50u Glass Fiber Filter, 37MM Treated Glass Fiber Filter, OSHA 42/47 Parallel Particle Impactor with Tared PVC PTFE (Teflon) Filter, 1.Ou PTFE (Teflon) Filter, 2.Ou PVC Filter (Tared) +/- l0u Quartz Fiber Filter, 37mm Passive Monitors UMEX 100 Formaldehyde Passive Monitor Assay Technologies Passive Organic Vapor Monitor Sealed Containers Tedlar Bag Armstrong Forensic Laboratory, Inc August 31, 2023 Sampling Media Media Code M-226-01 M-226-10 M-226-17-1A M-226-30-04 M-226-30-06 M-226-35-03 M-226-58 M-226-98 M-ORBO34 M-SEP-PAK M-225-9031 M-225-9032 M-225-9033 M-AOC M-CEF,25MM M-CEF,37MM M-CEF,MW50 M-GFF,37MM M-GFF,TR M-PPI-DISP-TARED M-PT FE jU M-PTFE,2U M-PVC,TARE M-QFF,37MM M-500-100 M-ASSAY-566 M-232-01 Media Pricing 226-01 $1.50 Each 226-10 $1.75 Each 226-17-1A $2.75 Each 226-30-04 $4.25 Each 226-30-06 $7.25 Each 226-35-03 $9.75 Each 226-58 $29.25 Each 226-98 $4.00 Each Orbo 34 $5.50 Each Sep -Pak $22.25 Each 225-9031 $40.00 Each 225-9032 $37.00 Each 225-9033 $24.00 Each AOC $6.00 Each CEF25mm $1.50 Each CEF37mm $1.50 Each MWCEF37mm $9.25 Each GTE 37mm $2.00 Each OSHA 47 Filter $4.00 Each Tared PVC $42.50 Each PTFE $13.50 Each PTFE $17.25 Each Tared PVC $6.00 Each QFF 37mm $6.50 Each 500-100 $25.50 Each 566 O VM $20.00 Each 232-01 $16.50 Each Page Gl of 1 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 59 of 63 Equipment Rental and Related Services Prices are outlined in the following groups: Integrated Sampling Other Services Armstrong Forensic Laboratory, Inc August 31, 2023 Section H Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 60 of 63 Description of Service Integrated Sampling Air Monitoring Pump Andersen Sample & Pump Respirable Dust Cyclone Low Flow Adapter Flow Rate Regulator for SC 6 Liter Summa Canister (SC) Other Services Client Equipment Calibration Equipment Download Armstrong Forensic Laboratory, Inc August 31, 2023 Equipment Rental Rental Length Pricing 1 Day $60.00 Each 3 Day $90.00 Each 1 Week $120.00 Each 1 Day $85.00 Each 3 Day $130.00 Each 1 Week $140.00 Each 3 Day $12.00 Each 1 Week $15.00 Each 1 Day $20.00 Each 3 Day $25.00 Each 1 Week $45.00 Each 1 Day $40.00 Each 3 Day $55.00 Each 1 Week $75.00 Each 1 Day $75.00 Each 3 Day $105.00 Each 1 Week $125.00 Each Per Hour Per Event $125.00 Each $55.00 Each Page HI of 1 Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 61 of 63 General Consulting Services Andrew T. Armstrong, Ph.D., C.P.C. Marion Armstrong, M.S.P.H., M.S.A., C.I.H. Kelly L. Wouters, Ph.D. Karen M. Deiss, S.S. Analyst, Other Reporting Packages Court Records Other Services Armstrong Forensic Laboratory, Inc August 31, 2023 Section I Vendor Services Agreement — Armstrong Forensic Laboratory, Inc. Page 62 of 63 General Consulting Services Description of Service Cost Unit AndrewT. Armstrong, Ph.D., C.P.C. Consultation, Travel, Phone and Standby $395.00 Hour Court Presentation and Deposition $495.00 Hour Video Deposition $595.00 Hour Marion Armstrong, M.S. P.H., M. B.A., C.I.H. Consultation, Travel, Phone and Standby $295.00 Hour Court Presentation and Deposition $395.00 Hour Video Deposition $495.00 How KellyL. Wouters, Ph.D. Consultation, Travel, Phone and Standby $295.00 Hour Court Presentation and Deposition $395.00 Hour Video Deposition $495.00 Hour Karen M. Deiss, B.S. Consultation, Travel, Phone and Standby $245.00 Hour Court Presentation and Deposition $345.00 Hour Video Deposition $445.00 How Analyst, Other Consultation, Travel, Phone and Standby $200.00 How Court Presentation and Deposition $300.00 How Video Deposition $400.00 Hour Reporting Packages "CLP Like" Reporting Package $250.00 Package TRRP Reporting Package $250.00 Package Court Records Affidavit $100.00 Each Litigation Packet/File Production $250.00 Each Duces Tecum $750.00 Each Other Services Computer Services (e.g.: CAD, database search) $125.00 Hour Court Production, Records Copy $125.00 Hour Data Recalculations $95.00 Hour Emergency Response (200% Analytical + Per Person) $250.00 Per Person/4 hrs Fax Transmission $1.50 Page Field use of Specialized Laboratory Equipment $150.00 Trip File Initiation/ Retainer for retention of Services $5,000.00 per File Sample Pickup/ Deliver within DFW Metroplex $45.00 Trip Site Documentation (Photographs) $95.00 Trip Technician (In-house or Field) $125.00 Hour Travel Mileage $0.70 per Mile Video Taping and Production $150.00 Hour Armstrong Forensic Laboratory, Inc Page Il of 1 August 31, 2023 Vendor Services Agreement - Armstrong Forensic Laboratory, Inc. Page 63 of 63