HomeMy WebLinkAboutContract 61193-CO2PROJECT NAME:
CONTRACT:
CFA #
CITY PROJECT #
CITY SECRETARY CONTRACT #
FID #
X#
FILE #
INSPECTOR:
PROJECT MANAGER:
DEVELOPER -AWARDED -PROJECT CHANGE ORDER
Quarry Falls Multi Family
Water & Sewer
CFA23-0174
105084
61193
30114-0200431-105084-EO7685
27931
W-3000
Henry Tristan
Ram Tiwari
CITY PARTICIPATION
Phone No: (682)263-2418
Phone No: (817)392-2237
YES
CSC No. 61193-0O2
CHANGE
ORDER No:
2
WATER
Developer
SEWER
CONTRACT UNIT
DRAINAGE
PAVING
STREET LIGHTS
CONTRACT
DAYS
Developer
Developer
Developer
Cost
City Cost
Developer Cost City Cost
Cost City Cost
Cost
City Cost
Cost
City Cost
ORIGINAL CONTRACT
$1,254,690.00
$104,345.00 I
$372,737.00 $0.00
$0.00 $0.00
$0.00
$0.00
$0.00
$0.00
100
EXTRAS TO DATE
$595.00
$0.00 I
$0.00 $0.00
$0.00 $0.00
$0.00
$0.00
$0.00
$0.00
CREDITS TO DATE
$0.00
$0.00 I
$0.00 $0.00
$0.00 $0.00
$0.00
$0.00
$0.00
$0.00
CONTRACT TO DATE
$1,255,285.00
$104,345.00 I
$372,737.00 $0.00
$0.00 $0.00
$0.00
$0.00
$0.00
$0.00
100
AMOUNT OF PROP. CHANGE ORDER
$1,520.00
$0.00 I
$0.00 $0.00
$0.00 1 $0.00
$0.00
$0.00
$0.00
$0.00
0
REVISED CONTRACT AMOUNT
$1,256,805.00
$104,345.00 I
$372,737.00 $0.00
$0.00 $0.00
$0.00
$0.00
$0.00
$0.00
100
TOTAL REVISED CONTRACT AMOUNT PER
UNIT
$1,361,150.00
$372,737.00
$0.00
$0.00
$0.00
REVISED COST SHARE
Dev. Cost:
$1,629,542.00
City Cost:
$104,345.00
TOTAL REVISED CONTRACT
$1,733,887.00
REVIEWED
By TIWARIR at 9:52 am, Aug 29, 2024
Revised: 12-17-2018
OFFICIAL RECORD
CITY SECRETARY
FT. WORTH, TX
Page 1
You are directed to make the follow ng changes in the contract documents:
CITY BID ITEM
PAY ITEM # # QUANTITY
5 3311.0001 0.19
UNIT I: WATER IMPROVEMENTS
CFW Unit
UNIT ITEM DESCRIPTION Price
TON Ductile Iron Water Fittings w/ Restraint
TOTAL UNIT I: WATER IMPROVEMENTS
Developer
UNIT PRICE Cost City Cost TOTAL
$8000.00 $1,520.00 $1,520.00
$0.00 $0.00
1520.00 $0.00 $1,520.00
1 1
REVIEWED
By TIWARIR at 9:52 am, Aug 29, 2024
Revised: 12-17-2018 Page 2
REASONS FOR CHANGE ORDER Water line connection to existing main relocated due to field constraints, two bends are required for the new connection.
RECOMMENDED:
mma, inc
By:
Name: Andrea Taylor, PE
Title: Principal
APPROVAL RECOMMENDED:
CFW - Water Department
By: Su6d��Pr
Name:JSuby Varughese
Title: IlEngineering Manager
RECOMMENDED:
CFW - 'Contract Compliance Manager
By:
Rarn Tiwari
R,in TI-1 Se14202414-15 CfJT
Name:
Ram Tiwari
Title:
Senior Professional
Engineer/PM
M&C Number:
24-0176
M&C Date Approved:
2/27/2024
Revised: 12-17-2018
APPROVED:
GS Quarry Falls Phase 1 Owner, LP
By:
Name: JR Thulin
Title: Vice President
APPROVED:
CFW - Assistant City Manager
Cana $ta�
By: Ra„a
Name: Dana Burghdoff
Title:
inn
ooFpoeT➢n
.........�°a
d>8 040
ATTEST
o== -.c
PVo g=p
nE4p56ti.e
Jannette S. Goodall
City Secretary
APPROVED:
GS Construction Great Plains, LLC
By: /*F'
Name: Philip Treacy
Title: Vice President
APPROVED AS TO FORM AND LEGALITY
CFW - Assistant City Attorney
By: Ricl,irc—!Sep 8,2024 08 22 CDT)
Name:
Richard McCracken
Title:
" Contract Compliance Manager (Project Manager):
By signing I acknowledge that I am the person responsible
for the monitoring and administration of this contract, include
ensuring all performance and reporting requirements.
❑ There are NO City Funds associated with this Contract
0 There are City Funds associated with this Contract
OFFICIAL RECORD
CITY SECRETARY
FT. WORTH, TX
Page 3
REVIEWED
By TIWARIR at 9:52 am, Aug 29, 2024
s ,c� ss vEa "v
MATCHLINE SEE SHEET Ii STA 14+— — —
\ \ w ER / i
\` �I O
\ \ \\�A hZIUa /
vE�ncw`oeucr
�SRezo,
...w..� rA �o�NST
_ sol, \ \"
1
f'CAL
"S 1
\ r _i,sov
730
725
0
720 0
+
Y
F
y
W
710 W
y
f
{
§ 700
g@
2
695
a —
m
F
�Y
sE,NLL.es2o
/ v ��
1 "6TP
PUBLIC a SLI 12—l
Cl
WL T.2 sl
-2 - - \ N 1 I ,b'XB]•JNTw-r 1EE
= =os sses o=IPaaOC /I DE
TA, "o w
11
\\ A1 CONTR MR SRALL FIRLD
�n5 _ V6RlFY 6.I7STING FL09LIN6 ///////
? E oIf✓u ,cJ �1�II11
CONMER CONPLlCT6. I
�jCC/01�1J�ESMT
\\\\� P"I o0 `_ z of
VA AVA�A� A 1 '� va mr ecsv
WL-2 (PUBLIC) STA 14+00 — END
a /
89pR! ,,y r3
�Ng Ncs
690 4 1 1 1 1L� I I 1 1�2 1 1 1 1� I I 11 1�2 1 1 1 1� I I I I I I 1 1�2 1 1 1 1� I I I I I I 1 1�2 1 1 1 1� I I I I I I I I I I I I I ego
14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50
W
lo
LEGEND. x' _.. 1C.a .. F
PROPOSED FIRE H1T)RANi y A�
SSEMBLD T w
.LVE SED BLOW OFF FTC /
PROPOSED AR RELEASE
�r�l /E- A�L�)
PROPOSED GATE VALVE �L w _ � WI Fly I r . & VAULT �S F•"I
PROPOSED WATER LINE w — O
PROPOSED WATER SERNCE r^' � P— W
PROPOSED SEWER LINE s: LL-
PROPOSED SEWER MANHOLE _=
PROPOSED SEWER SERNCE
PROPOSED STORM LINE _ O
PROPOSED STORM INLET
EXISTING WATER LINE
EXISTING FIRE II —IT
I-11G WATER VALVE
WATER STUDY NUMBERI �'\ T,-
WSL-2023-2576 \
1 ❑ m mla
`II T. .�,.
KEY MAP
NTS
TO SISET 2024
nrxmni Rinx,v ISFT Faa x["mat "ol[s tP E OF F s
DATA IS THORN AS RC L S
a A"IIIA"u a µ�,2a5
RUZ
ExncT lacy nays oT , t� DRTE c.10s
v""ncs __CS Know Know what's belOW. ssuc 121
Call before you dig.
Horn s i.1 1 E �« i siR CFNcan°oAo .'-S °ION --
CONCRETE DWALL cIE rna BOX CU `a sE H CENTER OF
CONCRETE MEADWALL 2 ai11/2, RFl o2 as
a , -IT vAULT aFT
Aa oes.Riv. ar
au n _ .. EHFE I— �T.
odo` a /NT THE xoa ao Ho /.NF WATER PLAN
oomw11UL11 11 IRA IS z,z° o ssa<sa"s ,`.e E o 12
vaxr of o.o.o carraicaT ®zoi< NNn IIC