Loading...
HomeMy WebLinkAboutContract 62769STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 03/01/2022 BN 1 Date Received: _______________ Permit No.: SWFMA-22-0067 Time Received: _______________ City Secretary No.: __________________ STORMWATER FACILITY MAINTENANCE AGREEMENT THIS AGREEMENT, made and entered into this ____ day of _____________, 2025, by and between West Worth Commerce Center I, LLC, a Texas limited liability company hereinafter referred to as “Landowner”, and the City of Fort Worth, hereinafter referred to as “City”. WITNESSETH WHEREAS, the Landowner is the owner of certain real property described as a acre tract of land situated in the J. Burssey Survey, Abstract No. 128, the Hays Covington Survey, Abstract No. 256, and the L.B. Creswell Survey, Abstract No. 367, Tarrant County, Texas according to the deeds recorded in Document Nos. D221103162 and D222119275, Deed Records, Tarrant County, Texas, hereinafter called the “Property”. WHEREAS, the Landowner is proceeding to build on and develop the Property according to the Site Plan/Subdivision Plan known as West Worth Commerce Center, hereinafter called the “Plan”, which is expressly made a part hereof, as approved or to be approved by the City and the Landowner provides for management of storm water within the confines of the Property; and; WHEREAS, the City and the Landowner, and their successors and assigns, agree that the health, safety and welfare of the residents of the City of Fort Worth, Texas require that on-site Stormwater Management Facilities be constructed and maintained on a portion of the Property; and WHEREAS, the City requires that on-site Stormwater Management Facilities (“Facility”) as shown on the Plan be constructed and adequately maintained by the STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 03/01/2022 BN 2 Landowner, its successors and assigns, the location and dimensions of which is shown and more particularly described by metes and bounds in the attached Exhibit “A1”, and Exhibit “A2” (“Facility Property”); and NOW, THEREFORE, in consideration of the foregoing premises, the mutual covenants contained herein, and the following terms and conditions, the parties hereto agree as follows: 1. The Landowner, its successors and assigns, shall adequately construct and maintain the on-site Stormwater Management Facility (“Facility”) at no expense to the City of Fort Worth in accordance with the design specifications for the Facility, attached as Exhibit “B”, and the current standards then in force and effect in the City of Fort Worth and with the Operations and Maintenance Plan attached to this Agreement as Exhibit “C”. The Stormwater Facility includes all pipes, channels or other conveyances built to convey Stormwater to the facility, as well as all structures, improvements, and vegetation provided to control the quantity and quality of the Stormwater. Adequate maintenance is herein defined as good working condition so that these facilities are performing their design functions. The Stormwater Structural Control Maintenance Checklists, attached to this Agreement as Exhibit “D”, are to be used to establish what good working condition is acceptable to the City. 2. The Landowner, its successors and assigns, shall inspect the Facility and submit an inspection report to the City annually. The purpose of the inspection is to assure safe and proper functioning of the Facility. The inspection shall cover the entire Facility, berms, outlet structure, pond areas, access roads, etc. Components of the Facility, which need maintenance or replacement to perform their design function, shall be noted in the inspection report along with the corrective actions to be taken. 3. The Landowner, its successors and assigns, hereby grant permission to the City, its authorized agents and employees, to enter upon the Property and to inspect the Facility Property whenever the City deems necessary. The purpose STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 03/01/2022 BN 3 of inspection is to follow-up on reported deficiencies and/or to respond to citizen complaints. The City shall provide the Landowner, its successors and assigns, copies of the inspection findings and a directive to commence with the repairs if necessary. 4.In the event the Landowner, its successors and assigns, fails to maintain the Facility in good working condition as specified herein, the City, its authorized agents and employees, may enter upon the Facility Property and take whatever steps necessary to correct deficiencies identified in the inspection report and to charge the costs of such repairs to the Landowner, its successors and assigns . It is expressly understood and agreed that the City is under no obligation to routinely maintain or repair said Facility, and in no event shall this Agreement be construed to impose any such obligation on the City, such obligation is Landowner’s. 5. The Landowner, its successors and assigns, will perform the work necessary to keep the Facility in good working order as appropriate. In the event the City pursuant to this Agreement, performs work of any nature, or expends any funds in performance of said work for labor, use of equipment, supplies, materials, and the like, the Landowner, its successors and assigns, shall reimburse the City upon demand, within thirty (30) days of receipt thereof for all actual costs incurred by the City hereunder. In the event that Landowner or its successors or assigns fail to pay the City for the costs incurred under this section, the City shall impress a lien for the costs of such work upon other lots owned by the Landowner. Such lien shall be perfected by filing in the office of the County Clerk of Tarrant County, Texas an affidavit identifying the property to be charged with such lien, stating the amount thereof, and making reference to this Agreement. 6. This Agreement imposes no liability of any kind whatsoever on the City. THE LANDOWNER AGREES TO HOLD THE CITY HARMLESS FROM ANY LIABILITY IN THE EVENT THE FACILITY FAILS TO OPERATE PROPERLY. LANDOWNER COVENANT AND AGREE AND DOES HEREBY INDEMNIFY, HOLD HARMLESS AND DEFEND STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 03/01/2022 BN 4 THE CITY OF FORT WORTH, ITS AGENTS, SERVANTS AND EMPLOYEES FROM AND AGAINST ALL COSTS, EXPENSES, LOSSES, DAMAGES, CLAIMS OR CAUSES OF ACTION WHATSOEVER ARISING, OR WHICH MIGHT ARISE, FROM THE FAILURE OF LANDOWNER OR ANY FUTURE OWNERS OF THE ABOVE FACILITY PROPERTY TO MAINTAIN THE FACILITY, INCLUDING, BUT NOT LIMITED TO THE BED AND BANKS OF THE DETENTION POND; ANY DAMAGES CAUSED TO PERSON OR PROPERTY DUE TO (1) FLOODING OF THE POND AND ITS BANKS, (2) SLOPE FAILURE OF THE BANKS OF THE POND, OR (3) FAILURE OF THE POND OR ITS BANKS TO OPERATE IN A MANNER CONSISTENT WITH CITY OF FORT WORTH CRITERIA TO PERFORM ANY OTHER DUTIES OR OBLIGATIONS HEREUNDER. 7. Landowner covenants and agrees that no habitable building shall be erected within the boundaries of the Property in which the Facility is located as outlined on Exhibit “A1”, and Exhibit “A2”, but this paragraph shall not preclude construction of other improvements within the boundaries of the Property in which the Facility is located, which do not impede drainage. Landowner covenants and agrees that no habitable building shall be erected on the above property abutting such boundaries of the Property in which is Facility is located, which shall have a finished floor at an elevation less than two feet above the maximum depth of water in the detention pond which would occur during a 100-year frequency flood. 8. This Agreement shall be recorded among the land records of Tarrant County, Texas, shall constitute a covenant running with the land, and shall be binding on the Landowner, its administrators, executors, assigns, heirs and any other successors in interests, including any property owner’s association. Executed this _7t_h ___ day of February CITY OF FORT WORTH Dana Burghdoff (Feb,20251 . CST) Dana Burghdoff Assistant City Manager City of Fo11 Worth Date: Feb 7, 2025 Approved as to Form and Legality: Matthew Murray Sr. Assistant City Attorney City Attorney's Office Date: Feb 7, 2025 ATTEST: Jannette S. Goodall City Secretary Date: Feb 10, 2025 STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 03/01/2022 BN 2025. LANDOWNER West W 01th Commerce Center I, LLC a Texas limited liability company ,--Date: Contract Compliance Manager: By signing, I acknowledge that I am the person responsible for the monitoring and administration of this contract, including ensuring all performance and reporting requirements. Rebecca Owen (Feb 7, 2025 15:02 CST) Rebecca Owen Planning Manager Date: Feb 7, 2025 5 STATE OF TEXAS § COUNTY OF TARRANT § This instrument was acknowledged before me on February 7th, 2025 by Dana Burghdoff, Assistant City Manager of the City of Fort Woi�th, on behalf of the City �pa�P�a' KATHLEEN BRADFORD �O� Notary Public STATE OF TEXAS " Notary I.D. 12197197 � s/� 9jFOFj� My Comm. Exp. Apr. 12, 20D Ka.�L�eeri ��ea.c� (/ Notary Public, State of Texas LANDOWNER STATE OF � Q_� ��`.-':� § COUNTY OF � c�,�iy�-�� § BEFORE ME, the undersigned authority, a Notary Public in and for the State of --T�:�o�5 , on this day personally appeared � c� �`..� ��`!�;— (name), `�i�(�,,� C�.51-Q �r' (title), known to me to be the .��� person whose name is subscribed to the foregoing instrument, and acknowledged to me that he/she executed the same for the purposes and consideration therein expressed, as the act and deed of �J 2�� ��Y�'�• Cu,�ry��,- c�. �:st,N�:— � ��C- (entity), a � Ivy1 ��-C* ��:�k���1'1 h.y c��rzk'�„�, (entity type) and in the capacity therein stated. GIVEN LTNDER MY HAND AND SEAL OF OFFICE this �� day of 'bfv , 20 � . � � . ,i ��k...,� Notaiy P��lic, ate of �� �� �,�,���� •'o.�''PYP°8,=, MEGHAN CHERRY : z: �•: =*� *- My Notary ID # 131017095 �'rg oF ;�+`�� Expires February 23, 2025 STORMWATER FACILITY MAINTENANCE AGREEMENT 6 Rev. 03/01/2022 BN STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 03/01/2022 BN 7 EXHIBIT “A ” LEGAL DESCRIPTION i� , . ExH�e�,-A� � ABBREVIATION LEGEND I ABBR. DEFINITION CCi COUNTY CLERK'S FILE NO. W C CIftF IRQN ROD FOUND WITH CAP C GRS �RON ROD SET W�CAP STAbiPED'WA.I. 571d" • CM CONTROIIING MONUMENT I tAAG NRII. SET IMTH SHINER STAMPED APPROXIMATE • �`� WA.I. R.P.1.5.5714" LOCATION PKF PK WAIL FOUND OFABSTRACTLINE� zcF -PicK-curi CONCRETEFOUN� � XCS 'X' CUT IN CONCRETE SET .� � Z ' _100' 200' � ( � Scale 1 "=200' ��d I} r � > � � _ ��Z WEST WORTH COMMERCE }. o � � CENTERI,ILC z CC #D221103162 � o v �. � � 4 2 ( • WESTRIDGE CHURCH I � OF NAZARENE I APPROXIMATE LOCATIdN , ' � OF ABSTRACT LINE " 3l4° IPF 1/2° CIRF � . . _ . _ _ _ — . — . . — . . "W.A.I; 5714"�_ . _ . . _ . MAG FND. CM L.B. CRESWEI.L SURVEY, 1l2 CIRF ABSTRACT N0. 367 _ . °6&G" �� WEST WORTH COMMERCE I CENTER I, LLC 1f2° CIRF CC #D222119275 "W.A.L 5714" (R) I i/2" CIRF °VJ A_I. 5714" fR1 N 88°29'S4" W t2) �l2` CIRF 1,527.23' "W.A.I. 5714° (R) I POINT OF � COMMENCING I I Winkelmann � ` POND 1��XHIBIT � `�� � � �? �.?'� . 8c Associates, Inc. r�p;�a�ar��;�;� 2.432 ACRES SHEET CONSULTINGCNIIENGINEERS � SURVEYORS � Y,�.'Q.. �'.•• 4;s (105,931, SQ r��.> BFAHIILCRESTPtKApRIYE.SUREi15 (872I�� t . • .. . . .. � .� W�llll5, tE1V5 ]SI30 t9%L7 �tr]OS3 FAX t .� � � TexasEn{pnearcReyiaGationNo.89 �.. . ,_EJNARCi:`JAY LUEKER Texas Surveyon No. 10086600 Exprae t2-31-25 .. . .� . , . . . COMRIGHT�2025.NRnkeimann6Assodates.lnc. �`. •••` •••••,• �i••• ..� e �-.:� __..�� . : �iE. ,.,_2�, ••� 5714 �: WESTWORTH COMMERCE CENTER.I, LLC OF Date: o�zz.zs ����'�s.s�a�'O� 3625 N. HALL STREET, SUITE 12$0 � . File: �s7o2-aoNo ��:�'�� 'y� DA�LAS TEXAS 75219 ;� ` . _�. �U1�. . Prniact Nn • 78702.D0 "�+oi�'F,i° . _ _..._..__ _.._ _._.._....-• --' -'--•--� � y� ' � ( ����� . � �. � W S ' _ 100' 200' Scale 1 "=200' . i i ABBREVIATION �EGEND A88R. DEFINI110N CC7F COUNN CIERK'S fILE NO. E CIRF IRON ROD FOUND WITH CAP CIRS IRON ROO SET WtCAP STAMPEO'WA.I. 5T14' CM CONTROLLING MONUMEM �G MAG NAII SET IMTH SHiNER STAMPED 'WA.1. R.P.L5.5714" PKF PK NAIL FOUND PKS PK NAlI SET XCF "X"CUTWCONCRETEFOUND ,/\ XCS 'X" CUT IN CONCRETE SET N35°32'37°E 46.19' N43°4&'08°E � 37.14'� N35°45'59`E ���^ on ca� L10-� v � 36.03' = N10°52'45°E � 51.67' N06°23'25"W NA3°13'21°E 98.41' N48°28'05"W 66.7T _\ E)--- MAG ' C� S11°07'38°E 21.09' S19°50'03"E � 65.23' S09° 15'09"E � 1 20.25' �, � �� S06°55'11°E 1NEST WORTN COMMERCE ��� ` 40.83' CENTER I, llC �� A 113 CC #D221103162 � \�`�\\ ` S01°33'22"W ��`���� 70.86' �ti���� S02°17'42"VJ � \�l 122.97' \� ���\� � POND EXHIBtT #t �� � 2.432 ACRES ,jl � � (105,931 SQ. FT.} �\ � S13°02'47"W ��� 89.24' . �� S27°40'22"W ,�8 . L14L15 77.98' 19 !>> 116 �INT OF N 88°29'54" W — �ininiin�� 1,527.23' Winkelman�. `�� ' ' & Associates, Inc. CONSULTINGCIVIIENGMEERS � SURVEYORS 8t50 HILLLREST PIAZA DRNE, bU1TE 215 ,,,:., . (9T1) 4W�'lO80 ORLLAS. TEXAS ]52m (8Th 486TOB8 FPX Texes Engineere Re�sbation No. 89 Texas Surveyots No.10088800 �pree 12-31-25 � COPYRIGHT � 2025, NAnkeiman� 6/4sodntes, Ix. scale . ," - zoo� � � Date: o�zz.2s . , � DWp: FilB : 78702-POND Proiect Nn. � 78702.00 ' . � POND 1 EXHIBIT �� �:; g �-�" . _ ,`@;. Ga �;�,-� ' 2.432 ACRES SHEET � �a: � � ,° .'`:�•. (1 Q5,931 SQ. FT.) � 's.1....... .. • .. ' 7 I,EONA}� dAY LtJ�KER v . �...r......L..... .. ,a . 5714 ��'.• WESTWORTH GOMMERCE CENTER I, LLC OF ,'�`•'���'ESs�o�'�q� � 3625fiV. HALi� STREET, SUITE 12$0 � ��,{jp ,S �Rv� � , DALLAS; TEXAS 75219 .:- � '"'�......, .- ...,..., -�- � "� � � �� � �� - POND 1 EXHIBIT LINE AND CURVE TABLES LINE TAB�E LINE # BEARIN� DISTANCE L1 N41°31'55°E 15.53' L2 N88°30'15"W 14.66' L3 N59°41'01"W 4.96' l4 N50°16'47"W 54.38' L5 N46°47'39"W 16.85' L6 N15°53'20°W 46.28' L7 N09°09'30"E 36.98' L8 S73°30'10"E 25.48' L9 N40°3T24"E 33.29' L10 N32°10'24"E 27.79' L11 N45°O6'55"E 19.6A' . � � LINE TABLE ._,_,� �,.,�„.�,- - LINE # BEARING DISTANCE �12 N27°49'20°E 23.34' L13 S03°36'24"E 33.06' L14 S52°29'03°E 3.54' L15 S49°17'12"E 64.10' L16 S40°42'48"W 12.50' L17 N49°17'12"W 63.75' L18 N52°29'03"W 56.64' L19 N54°47'45"W 42.96' L20 N67°36'37"W 21.02' L21 S4$°24'S2°W 89.33' L22 552°00'24"W 82.77' CURVE TABLE N0. DEITA RADIUS LENGTH CH. l CH. B C1 132°18'23° 24.99' 57.71' 45.72' S75°44'00"E � -Winkel�mann ,t. ,��,�,:�r'� �� ��. & ' Associafes, Inc. ,`p ��s `� �„��;. � : .��y CONSULTING CIVILENGINEERS � SURVEYORS �: Q� � ' � �CS �r`i�� 6]5� HILLCNEST PIATA DRIVE. SVITE 315 ���� �ere)��am .•.S.�n...........�.......:"...: DAItAS. TE%AS T52]0 . •c .. (g� 686JU98 FAX [�. `fezasE�naenRepahetionNo.89 lE0NF4RD JAl� �..�.�Ct\�t'4�� Texas Sunayore Nq,10086800 F�cpres 12-31-25 � ' ., �y � � � , COPYRIGHT� 2025.N4nkeimannBAssodetes.l�x. . 1 ^• ••••• . a-: x wA A �7,� 4 ,� .. s�ie : � _.:�o . �. �-� 78702-POND � �`� t _ POND 1 EXHIBIT 2.432 ACRES (105,931 SQ. FT.) NESTWORTH COMMER�E CENTER I, LLC 3625 N. HALL STREET, SUITE 1280 DALLAS, TEXAS 75219 �� . . � HEET 3 OF � Q� � i � � � l � � STATE OF TEXAS § COUNTY OF TARRANT § BEING a tract of land situated in the J. BURSSEY SURVEY, ABSTRACT NO. 128, City of Fort Worth, Tarrant County, Texas, and being a portion of a tract of land as described in deed to West Worth Commerce Center I, LLC, recorded in County Clerk's File No. D221 1 031 62, Officiai Pubiic Records, Tarrant County, Texas (O.P.R.T.C.T.), and being more particularly described as foliows: COMMENCING at a 1/2-inch iron rod with red plastic cap stamped "W.A.I. 5714" found for the Southwest corner of a trcat of land as described in deed to West Worth Commerce Center I, LLC, recorded in County Cierk's File No. D222119275, O.P.R.T.C.T., said iron rod also being the most Southerly Southeast corner of said West Worth Commerce Center 1, LLC (CC #D221103162); THENCE North 88 deg 29 min 54 sec West, departing the West line of said West Worth Commerce Center I, LLC (CC #D222119275) and along the South line of said West Worth Commerce Center I, LLC (CC #D221103162), a distance of 1,527.23 feet to a MAG nail found for the most Southerly Southwest corner of said West Worth Commerce Center I, LLC (CC #0221103162); THENCE North 48 deg 28 min 05 sec West, departing the South line and along the Westerly line of said West Worth Commerce Center i, LLC (CC #D221103162), said line also being the approximate centeriine of a creek, a distance of 66.77 feet to a point; THENCE departing said Westeriy line and over and across said West Worth Commerce Center I, LLC (CC #D221103162), the following: North 41 deg 31 min 55 sec East, a distance of 15.53 feet to the POINT OF BEGINNING; North 88 deg 30 min 15 sec West, a distance of 14.66 feet to a point for corner; North 59 deg 41 min 01 sec West, and distance of 4.96 feet to a point for corner; North 43 deg 13 min 21 sec East, a distance of 98.41 feet to a point for corner; North 47 deg 31 min 47 sec East, a distance of 76.30 feet to a point for corner; North 50 deg 16 min 47 sec West, a distance of 54.38 feet to a point for corner; North 46 deg 47 min 39 sec West, a distance of 16.85 feet to a point for corner; North 15 deg 53 min 20 sec West, a distance of 46.28 feet to a point for corner; North 05 deg 23 min 25 sec West, a distance of 51.91 feet to a point for corner; North 02 deg 00 min 28 sec East, a distance of 51.67 feet to a point for corner; North 10 deg 52 min 45 sec East, a distance of 28.46 feet to a point for corner; North 18 deg 45 min 06 sec East, a distance of 36.03 feet to a point for corner; North 09 deg 09 min 30 sec East, a distance of 36.98 feet to a point for corner; South 73 deg 30 min 10 sec East, a distance of 25.48 feet to a point for comer; North 40 deg 31 min 24 sec East, a distance of 33.29 feet to a point for corner; North 35 deg 45 min 59 sec East, a distance of 39.50 feet to a point for corner; ��� Winkelmanri & Associates, Inc. CONSULTING CIVII ENGINEERS � SURVEYORS �� -S]SOHILlCRFSTPLA2ADRNE.SUITE215 :+ �9�Z�49p-�OW OAIIAS.TEXAS ]52J0 19I3)dg0-109�JfN( -. � Texas Engineers Registretbn No. 89 � �� Texas Suneyors Na. 1098b600 Expires t237-25 � COPYRIGHT O�2025, Winkeimann 8 Assoc�ales, Inc, ��� Scale : ��A ,; Date: o�.z2.zs ��. File : �s�o2-aorvo No.: �8702.00 (CONTINUED ON SHEET 5} �. �� ;�r,a POND 1 EXHIBIT �� `}` f' ' �; -2.432 AGRES � SHEET ...�i....�...:. �a`3j�� , ••� (1.05,931 SQ. FT:) lEON�.�D JA � { .. � „-`� . . .......... ' . : •�0 57�4 :... `t',�?o,�� ��,� �,. WESTWORTH�'COMMERCE `CENTER I, LLC OF '� ,. .y••... ss�, � ��� � , �� SUR��, ` � � � � ��3625 N. �HALL STREET, SUITE 1280 � . ��� � DALLAS, TEXAS 75219 POND 1 EXHIBIT (CONTINUED FROM SHEET 4) North 32 deg 10 min 24 sec East, a distance of 27.79 feet to a point for corner; North 45 deg 06 min 55 sec East, a distance of 19.64 feet to a point for corner; North 43 deg 46 min 08 sec East, a distance of 37.14 feet to a point for corner; North 35 deg 32 min 37 sec East, a distance of 46.19 feet to a point for corner; �' l � North 27 deg 49 min 20 sec East, a distance of 23.34 feet to a point for corner and being the beginning of a curve to the right having a radius of 24.99 feet, a centrai angle of 132 deg 18 min 23 sec, a chord bearing of South 75 deg 44 min 00 sec East, and a chord length of 45.72 feet; Along said curve to the right, an arc distance of 57.71 feet to a point for corner; South 11 deg 07 min 38 sec East, a distance of 21.09 feet to a point for corner; South 19 deg 50 min 03 sec East, a distance of 65.23 feet to a point for corner; South 09 deg 15 min 09 sec East, a distance of 20.25 feet to a point for corner; South 06 deg 55 min 11 sec East, a distance of 40.83 feet to a point for corner; South 03 deg 36 min 24 sec East, a distance of 33.06 feet to a point for corner; South 01 deg 33 min 22 sec West, a distance of 70.86 feet to a point for corner; South 02 deg 17 min 42 sec West, a distance of 122.97 feet to a point for corner; South 13 deg 02 min 47 sec West, a distance of 89.24 feet to a point for corner; South 27 deg 40 min 22 sec West, a distance of 77.98 feet to a point for corner; South 52 deg 29 min 03 sec East, a distance of 3.54 feet to a point for corner; South 49 deg 17 min 12 sec East, a distance of 64.10 feet to a point for corner; South 40 deg 42 min 48 sec West, a distance of 12.50 feet to a point for corner; North 49 deg 17 min 12 sec West, a distance of 63.75 feet to a point for corner; North 52 deg 29 min 03 sec West, a distance of 56.64 feet to a point for corner; North 54 deg 47 min 45 sec West, a distance of 42.96 feet to a point for corner; North 67 deg 36 min 37 sec West, a distance of 21.02 feet to a point for corner; South 48 deg 24 min 52 sec West, a distance of 89.33 feet to a point for corner; South 52 deg 00 min 24 sec West, a distance of 82.77 feet to the POINT OF BEGINNING. CONTAINING within these metes and bounds 2.432 acres or 105,931 square feet of land, more or less. Bearings shown hereon are based upon an on-the-ground Survey performed in the field on the 30th day ofAprii, 2021, utilizing a G.P.S. bearing related to the Texas Coordinate System, North Texas Centrai Zone (4202}, NAD 83, grid values firom the GeoShack VRS network. �`� Winkelmann & Associates, Inc. CONSULTING CIVIL ENGINEERS � SURVEYORS 6'lS�HIILCRFbTP(AUORIVE.SUITE215 �'. � r.. (gTh4BLL'N80 � wius. Tex�s raw � .. . � �erzt reo-roes Fnx Texas Errypnaera R¢psiration No. 89 Tezx Surveyorc No.10086600 Expires 12Jt-25 COPYRIGHT � 2(125, Winkeimann 8 Asaodates, l`x. N!A o,.zz.zs - �i'�°� T�''+ • ,�@^,., isre,�•:+�'� . 4.G � �✓J: � 4 •• �� cC , �! , LEONARD JAY LUEK�R '.� �..o_ ...5714 . a :;� : POND 1 EXHIBIT 2.432 ACRES (105,931 SQ. FT.) WESTWORTH COMMERCE CENTER I, �LC 3625 N. HALt STREET, SUITE 1280 DALtAS; TEXAS 75219 • N W APPROXIMATE • LOCATION OF ABSTRACT LINE � �� J � N � � O 0' 100' 200' Z o I � Scale 1 "=200' �•a m alr y; w w � �� � c=i� ' z W.O C~'� �I Z � O m U �. � >— . Q 2 I POND EXHIBIT #2 3.986 ACRES (173,620 SQ. T.) ,_ ' S89°11'13"E 541.00' � N J -� ��1 L30 c� I(2) 112" CIRF W.A.I. 5714" (R) . POINT OF � BEGINNING I I `�� Winkelmann & Associates, Inc. CONSULTING CIVIL ENGINEERS � SURVEYORS 6750HILLCRESTPLA2ADRNE,SURE215 (9T3)490.7090 DALlAS.TEXAS 75230 (9721490.]099FAX Texas Engineers Registration No.89 Texas Surveyors No. t00B6600 Expires 12-31-23 COPYR IGHT O 2023, W nkelmann 8 Associates, Inc. Scale : �" = 200� Date: �o.io.za Dwq. File : �8�oz-PONo Proiect No.: �e�oz.00 E EXHIBIT A2 ABBREVIATION LEGEND ABBR. DEFINIT70N CC# COUNN CIERK'S FILE NO. CIRF IRON ROD FOUND WITH CAP CIRS �RON ROD SET W/CAP STAMPED'W.A.I. 5714' CM CONTROLLING MONUMENT MAG MAG NAIL SET WITH SHINER STAMPED 'W.A.I. R.P.L.S. 5714" PKF PK NAIL FOUNp PKS PKNAILSET XCF 'X' CUT IN CONCRETE FOUND XCS 'X' CUT IN CONCRETE SET WESTRIDGE CHURCH OF NAZARENE APPROXIMATE LOCATION L36 OF ABSTRACT LINE / 314" IPF 112" CIRF — _ . . _ . . "W.A.1:5714" R /� MAG FND. CM L.B. CRESWELL SURVEY, ABSTRACT N0. 367 /,���� POINT OF '//�//�� � vz"CIRF I ICOMMENCIN �� ,�g "W.A.I. 5714" (R) ���� � WESTWORTH Ch B=S72°15'01"W � COMMERCE CENTER I, LLC Ch L=304.44� 112" CIRF CC #D222119275 L=309.15' "W.A.I. 5714" (R) R=510.00� S 54°53'04" W p=034°43'55" 236.83' �� �``V �' T o�Nj ............................: LEONARDJAYLUEKER � '• A 5714 / _�r � POND 2 EXHIBIT 3.986 ACRES (173,620 SQ. FT.) WESTWORTH COMMERCE CENTER I, LLC 3625 N. HALL STREET, SUITE 1280 DALLAS, TEXAS 75219 SHEET 1 OF 4 o��g��2 POND 2 EXHIBIT LINE AND CURVE TABLES LINE TABLE LINE # BEARING DISTANCE L28 N35°O6'40"W 60.00' L29 S69°12'55"W 71.06' L30 S89°35'08"W 30.73' L31 N88°29'54"W 189.63' L32 N01 °25'37"E 54.05' L33 N01 °33'58"E 45.43' L34 N01°39'43"E 51.33' L35 N19°11'36"E 35.76' L36 S87°56'56"E 25.97' L37 S32°44'30"E 24.87' L38 S54°53'04"W 58.74' L39 N35°06'56"W 34.50' L40 S54°53'04"W 81.49' CURVE TABLE N0. DELTA RADIUS LENGTH CH. L CH. B C2 14°1333" 453.40' 112.57' 112.28' S62°06'09"W C3 20°22'12" 215.00' 76.44' 76.04' S79°24'02"W C4 34°57'52" 57.50' 35.09' 34.55' N65°38'09"W C5 32°33'41" 225.06' 127.90' 126.19' S15°16'57"E C6 89°44'54" 24.50' 38.38' 34.57' S10°00'37"W "� Winkelmann & Associates, Inc. CONSULTING CIVIL ENGINEERS � SURVEYORS 6]SOHILLGRESTPlAZAORNE,SUfTE215 (9]7)d9o-7U90 �ALlAS.TE%AS 75230 (9]2�49P7099FA% Tezas Engineers Registre[ion No. 89 Texas Surveyors No. 100B66U0 Expires 72-37-23 COPYRIGHT O 2023, Winkelmann 8 Associates, Inc. Scale : NiA Date : io.�o.zs Dwq. File : �e�oz-PON� Proiect No. : �8�oz.00 /�.���G\STE �'i" 'i1 7 �:' � a9N •���������.�.����������i�.. LEONARpJAYLUEKER Q�9w °�F�14b?P.Qr/, EXHIBIT A2 POND 2 EXHIBIT 3.986 ACRES (173,620 SQ. FT.) WESTWORTH COMMERCE CENTER I, LLC 3625 N. HALL STREET, SUITE 1280 DALLAS, TEXAS 75219 SHEET Z Or 4 Jd/18/z3 POND 2 EXHIBIT STATE OF TEXAS § COUNTY OF TARRANT § EXHIBIT A2 BEING a tract of land situated in the J. BURSSEY SURVEY, ABSTRACT NO. 128, the HAYS COVINGTON SURVEY, ABSTRACT NO. 256 and the L.B. CRESWELL SURVEY, ABSTRACT NO. 367, City of Fort Worth, Tarrant County, Texas, and being a portion of a tract of land as described in deed to West Worth Commerce Center I, LLC, recorded in County Clerk's File No. D222119275, Official Public Records, Tarrant County, Texas (O.P.R.T.C.T.), and being a portion of a tract of land as described in deed to West Worth Commerce Center I, LLC, recorded in County Clerk's File No. D221103162, O.P.R.T.C.T. and being more particularly described as follows: COMMENCING at a 1/2-inch iron rod with red plastic cap stamped "W.A.I. 5714" found for the most Easterly corner of said West Worth Commerce Center I, LLC (CC #D222119275), said iron rod being the beginning of a curve to the left having a radius of 510.00 feet, a central angle of 34 deg 43 min 55 sec, a chord bearing of South 72 deg 15 min 01 sec West and a chord length of 304.44 feet; THENCE departing the North line and along the Southerly line of said West Worth Commerce Center I, LLC (CC #D222119275) and along said curve to the left, an arc distance of 309.15 feet to a 1/2-inch iron rod with red plastic cap stamped "W.A.I. 5714" found; THENCE South 54 deg 53 min 04 sec West, continuing along said Southerly line, a distance of 236.83 feet to a 1/2-inch iron rod with red plastic cap stamped "W.A.I. 5714" found; THENCE departing said Southerly line and over and across said West Worth Commerce Center I, LLC (CC #D222119275) tract and said West Worth Commerce Center I, LLC (CC #D221103162) tract, the following: North 35 deg 06 min 40 sec West, a distance of 60.00 feet to the POINT OF BEGINNING and the beginning of a curve to the right having a radius of 453.40 feet, a central angle of 14 deg 13 min 33 sec, a chord bearing of South 62 deg 06 min 09 sec West and a chord length of 112.28 feet; Along said curve to the right, an arc distance of 112.57 feet to a point for corner; South 69 deg 12 min 55 sec West, a distance of 71.06 feet to a point for corner and the beginning of a curve to the right having a radius of 215.00 feet, a central angle of 20 deg 22 min 12 sec, a chord bearing of South 79 deg 24 min 02 sec West and a chord length of 76.04 feet; Along said curve to the right, an arc distance of 76.44 feet to a point for corner; South 89 deg 35 min 08 sec West, a distance of 30.73 feet to a point for corner; North 88 deg 29 min 54 sec West, a distance of 189.63 feet to a point for corner and the beginning of a curve to the right having a radius of 57.50 feet, a central angle of 34 deg 57 min 52 sec, a chord bearing of North 65 deg 38 min 09 sec West and a chord length of 34.55 feet; Along said curve to the right, an arc distance of 35.09 feet to a point for corner; North 01 deg 25 min 37 sec East, a distance of 54.05 feet to a point for corner; North 01 deg 33 min 58 sec East, a distance of 45.43 feet to a point for corner; (CONTINUED ON SHEET 3) `�� Winkelmann & Associates, Inc. CONSULTINGCIVILENGINEERS � SURVEYORS 6]`AHILLCftESTPLAZAOFIVE,SUfTE215 (972)490.]090 �ALLAS.TE%AS I533U (9T11696�099FA% Tezas Engineers Registration No. 89 Texas Surveyors No. 10086600 Expires 12J7-23 COPYRIGHT� 2023,WinkelmannBAssociates,lnc. Scale : NiA Date : io �o.za , File : �8�oz-PON� t No. : �a�oz.00 / ,�P�� �rFTF-F �: Q.`` � R o�tJ� ........................:. LEONARp �qy LUEKER ��,poF67�' �..P Q.. ��`l'O � S Z: ;��(�el/ POND 2 EXHIBIT 3.986 ACRES (173,620 SQ. FT.) WESTWORTH COMMERCE CENTER I, LLC 3625 N. HALL STREET, SUITE 1280 DALLAS, TEXAS 75219 HEET 3 OF 4 POND 2 EXHIBIT (CONTINUED FROM SHEET 2) North 01 deg 29 min 45 sec East, a distance of 126.01 feet to a point for corner; North 01 deg 39 min 43 sec East, a distance of 51.33 feet to a point for corner; North 19 deg 11 min 36 sec East, a distance of 35.76 feet to a point for corner; South 89 deg 11 min 13 sec East, a distance of 541.00 feet to a point for corner; EXHIBIT A2 South 87 deg 56 min 56 sec East, a distance of 25.97 feet to a point for corner and the beginning of a curve to the left having a radius of 225.06 feet, a central angle of 32 deg 33 min 41 sec, a chord bearing of South 15 deg 16 min 57 sec East and a chord length of 126.19 feet; Along said curve to the left, an arc distance of 127.90 feet to a point for corner; South 32 deg 44 min 30 sec East, a distance of 24.87 feet to a point for corner and the beginning of a curve to the right having a radius of 24.50 feet, a central angle of 89 deg 44 min 54 sec, a chord bearing of South 10 deg 00 min 37 sec West and a chord length of 34.57 feet; Along said curve to the right, an arc distance of 38.38 feet to a point for corner; South 54 deg 53 min 04 sec West, a distance of 58.74 feet to a point for corner; North 35 deg 06 min 56 sec West, a distance of 34.50 feet to a point for corner; South 54 deg 53 min 04 sec West, a distance of 81.49 feet to the POINT OF BEGINNING. CONTAINING within these metes and bounds 3.986 acres or 173,620 square feet of land, more or less. Bearings shown hereon are based upon an on-the-ground Survey performed in the field on the 30th day ofApril, 2021, utilizing a G.P.S. bearing related to the Texas Coordinate System, North Texas Central Zone (4202), NAD 83, grid values from the GeoShack VRS network. "� Winkelmann & Associates, Inc. CONSULTING CIVIL ENGINEERS � SURVEYORS 6]SOHILLCRESTPLAZA�RNE,SUITE215 (9]])d9Q7090 OALlAS,TE%AS 25230 (97])490-]0%FAX Texas Engineers Registration No. 89 Texas Surveyors No. t00B6600 Expires 72-37-23 COPYRIGHTOO 2023,WnkelmannBAssociates,lnc. >cale : NiA Date: �o.�o.za . Fl�e : 78702-POND t Nn • 78702.00 o �,��,� :�� �� .� � o :� LEONqR� �AY LUEKER .�- � �? 5714 �.;: : rs POND 2 EXHIBIT 3.986 ACRES (173,620 SQ. FT.) 3TWORTH COMMERCE CENTER I, LLC 3625 N. HALL STREET, SUITE 1280 DALLAS, TEXAS 75219 HEET 4 OF 4 /�/!8/23 STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 03/01/2022 BN 8 EXHIBIT “B” DESIGN PLAN AND SPECIFICATIONS ,�" � ���� � � � �, - - �� , LEGEND � I • � �� ' � � ; i '�� �- � I � 705 E%ISTING CONTOURS . �� _��/ �� E X H I B I T B�(1 0 F 2 2) ,� ''� �,z PR�osEo ��r«�RS � � ' � � . �.', � .i� � �� j � � � � WALL /�p� , � - ; � � � /� �� j '� �� .' � BOUNDARY / VV . � � � � � FEMA EFFECTIVE i�i �� _ � �� .� � � ,� � :� 100YR FLOODPLAIN > / / I� �� � /� ,� �� O FEMA EFFECIIVE �' � � � , �� � � 100YR FULLY DEVELOPED , . �'� / / � I • . ��j ''� �� 0 FLOODPLAIN / � � 1 � � � � FLOODPLAIN EASEMENT � � � / / �i ' � , , i S ; i / � � ,� ,.i � � � . . q�/ � � . � / �� � i- �'�� /� � A , r-- 5. � 1 ��� � I �� "��- ,-_ . , - , � � � � � , f �i - , � �. � , _ �i , � ` � � � �' �cble, � � ' ' . � � � r� .� , �� � , � „ � ,� ;,_� 00'" � � , , � � ' ; � � , � ' ��� ��`` _ � �� - � _ \ �- �% � SWFM A � �' ,�� , % , �, . � , , / ,/ � s. ���� � . � . , � � j ,;, � BOUNDARY � —4:1 ENTRANCE �, � / � �j ��/����!� � ��� � Z�; �� RAMP �\ 720.0 ` � CONSTRUCT � � ; � � , , EMERGENCY SPILLWAY , � �' , , � � � ; � ' FLARED—WING � 245 WIDEx0.5 DEPTH � , � � �ETENT � ^ � ION � HEADWALL � (GRASS) , ; ,� PON� � .,. ... � ,,\.,� �� � � � ; ; �„ EASEMENT 6' CONCRETE ,, , � ,'� .� , i � � \ �� �! I ��� FLUME � INSTALL RIP—RAP FOR fi ��������� �� i DETENTIo �` �� �'���'� �� EMBANKMENT EROSION � � ',`' P N� � �o `,, � � � - ��� � OTECTION � � � � �� � � � PR - , � � �. � � _ _ � ' � ' � ,� ` , � j i -� I � � � �� � � �_ ,� �, ��� ��� � ��� � O � � ��� �� '� \ � 79 8 97 � , / �/� � � .� ��� � � � � ��. � ���� � � .. STM� � �� � i �, � �� �'�� � l , �� OU TLET `� ; �,, � � , �� ��� � '�� � \. / ; � � STRUCTURE � ,, �20.0 � � _ _ FLARED WING �� �'� � � � �� � � � ��.� � � � , `o oaTW � H EAD WALL � � ; � ' ;� � OUTFALL �� �,o.00BW�-;, a �� i � , � \ 1 � �� \ �� .. � . . �� . ... � - -- � �. �� .\ �.., � � �� r � _ OUT TO � �, �,4.�9TW �__ � PROPOSED DITCH - , 708'°B � � �� � � � � �_ �� � � � � RETAINING WALL � '�� -�-- � � __, `. \. � ,,� � ��� � DITCH OUT �� _ � �, ,� �v.soTw � � i � _; . � I �� TO CREEK �, , �� � � ��,,,, .� , �o9.25BW �� � ��.,� � � � � � � �. , , , � � ♦, � ;_ �� �717.15TW� � ,, 9kr�F�\ � \ \� \ �� I ♦ \ ♦ 708.10BW � , � � � �� ' � �♦ 708_OOTW � �� , � ' � - �� ��� -�- �� �SS MH � ��� 708.00BW � � � � � __ �_ � , � � � , � . � -� �, , � ; -- � — -- ---- — _ — _ �, � � � � , � � - - �,-, . ` � - . ,_,._.� � _ �_ ,, � ;.• - _ >_ - - - -- - -=� - - � �� - � , . - - . � � ; , ,� ., ., � � � -�- _- � �� � _ _. _ � � -- _ -�- �__ - __ - _�_ . � � � � _ � � _� � �---�� � � � - � �- _ -� � � < ��- - � _ � � _= , � . � _ _ � -. � - � _ � ,�� , - �_ : -; �. ♦;� - -,`�- - - - - - - _ ��—i - _ ; x - � - - - ---� _-> ,-� -_ ,- , .. �,_ � --- - � � ' -- _ � , , , _ NO SAVED OR PROPOSED ��� `- � � �` � � �- � - REFERENCE SHEET 13 �� - ROAD - - FOR HEADWALLS T� ��' TREES WITHIN SWFMA -�`� CHAPIN - STRUCTURAL DESIGN � � MAINTAINED AREA � � � � .� �_. � � � � �� �� � �� � META � � � �— . � � \ ��, �� 1„ , _____ - � �' � GATE ��� Winkelmann & Associates, Inc. DETENTION POND 1 PLAN SHEET CONSVLTING CNIL ENGMEERS ■ SURVEYORS 6)SOHILLCRESTPWADRNE,SIIRE215 �9,�,.�_�oso NWC CHAPIN ROAD & ALEMEDA STREET � DALVS, iE%RS 5230 (91]) s90-�p99 FqX Te.a= Engineers Regislralion No 89 FORT WORTH, TEXAS Texas Surveyors Reqistration No. 100866-00 COPIRIGHT '�� 20222, Winkelmann & Asso<iates, In<. Scale : 1'� — 100' Date : 12�27�2024 �Wg. F�ie : Detention Pond.dwa � e 735 730 725 720 715 710 705 700 35 30 25 20 715 710 05 00 735 730 � 725 720 715 710 705 700 735 730 � � 725 (V 7LO � 4 , O, 715 DITCH N.7.S. 710 705 3000 P.S.I. CONC. `h 5" �3 Bars at I 700�¢'3 Bars ot 1B" O.C. 6• �.C. 6' 6' CONCRETE FLUME (INSIDE POND) N.Ts. 0+00 1+00 2+00 3+00 4+00 Pond1 B—B EXHIBIT B 2 0� 22 i�Vinkelmann ��� & Associates �n�. DETENTION POND 1 CROSS—SECTIONS s CONSULTMG CIVIL ENCINEERS • SURVEYORS - - . suirE zis (s�2) aso-�o90 (e�z) aeo-�o99 rnx Texas En9'^eers Re9�olrotion No- 89 i�as Surveyors Reg�shation No. 100866-00 COPVRIGHT � 20222. Winkelmonn & Associates, Inc Scale : N.T.S. Date : 12�27�21 �wq. F�ie : Detention Pond.dwq FORT WORTH, TEXAS etention SHEET � on Nond—zUz.S—Uts—Uy_dwg 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 Pond1 A—A 4.00' N � 0 SAFETY GRATE FOf EMERGENCY RELEASE 1.18x1.09' ORIFICE 1.35'x1.96' ORIFICE 1.05'x0.90' ORIFICE INSTALL: TRASH RACK EXHIBIT B (3 OF 22) "� w inxeimann & Associates, Inc. CONSULTING CNIL ENGINEERS • SURVEYORS , SUIiE 215 (9l2) �90-)090 )5230 (9]2) 490-)099 FnX Texas Eng'inee�s Reglsl�alion No- 89 Texas Surveyors Registratlon No. 100866-00 COPYRIGHT � 2020. Winkelmann & Associatas, Inc Scole : N.T.S. Date : 12�27�2� Dwg. File : Detention Pond.dwq SOMETRIC VIEW N.T.S. REFERENCE SHEET 14 FOR OUTFALL STRUCTURAL DESIGN DETENTION POND 1 OUTFALL STRUCTURE FORT WORTH, TEXAS etention on Pond-2023-08-09 dwq SII��T 3 FRONT VIEW REAR VIEW N.T.S. N.T.S. Elevation 708.25 709.00 710.00 711.00 712.00 713.00 713.192 714.00 715.00 715.269 716.00 717.00 718.00 718. 9717 719.00 720.00 Pond 1 Storage (ac-ft) 0.0000 0.0335 0.2780 0.8200 1.5987 2.5160 2.7099 3.524 4.624 4.9454 5.820 7.114 8.516 9.9870 10. 030 11.653 Discharge Rate (cfs) 0.0000 1.7809 5.1162 6.8934 8.2983 9.4977 9.7115 14.897 25.320 27.1125 33.413 42.885 49.549 55.0899 55.241 60.325 ORIFICE EQUATION Q = CA 2gH Q = ORIFICE FLOW DISCHARGE (CFS) C = DISCHARGE COEFFICIENT (0.6) A = AREA (ft2) g= ACCELERATION DUE TO GRAVITY (32.2 ft/s) H= EFFECTIVE HEAD ON THE ORIFICE lftl POND 1 DETENTION CALCULATIONS Q=C.L.H3�2 Q(cfs)(known)=291.6 POND 1 OUTLET STRUCTURE DETAILS STM Event 1 STM Event 2 STM Event 3 1 -YR 5 -YR 100 -YR STORM PEAK I STORM PEAK I STORM PEAK WTR Surtace Elev. 713.19 715.27 718.97 Elevation Difference 4.94 2.08 3.70 Qnnnxnuowne�E (cfs) 9.71 27.11 55.09 100 YR Hefifiective �ft% HA3-ws3 3.11 Area (ftz) A3 1.28 5 YR Hette�t��e �ft) Hnvwsz 1.40 Hnz_wss 5.11 Area (ftZ) AZ 2.65 AZ 2.65 Heffective �ft) Hai-wsi 4.42 HAl-wsz 6.49 HA1-ws3 10.20 1 YR Area (ftZ) A1 0.94 A1 0.94 A1 0.94 ORIFICE FLOW DISCHARGE RATE 100 YR Orifice Flow QAa-wsa 11.07 5 YR Discharge QAZ-ws2 15.34 QAZ-wsa 29.26 1 YR (cfs) Qni-wsi 9.71 Qai-ws2 11.77 Qai-wsa 14.75 �ota� (�s) 9.71 27.11 55.09 SLOT OPENING DETAILS A1 A2 A3 Area (ftZ) 0.94 2.65 1.28 Wdth (ft) 0.90 1.96 1.09 Height (ft) 1.05 1.35 1.18 Flowline 708.25 713.19 715.27 H(ft)=0.5 Crest Invert L(ft)=245 Elevation=718.97' L' �� - - � 720.00' � 718.97' EMERGENCY SPILLWAY TRAPEZOIDAL WEIR (CIPOLLETTI) EXHIBIT B(4 OF 22) N.T.S. "� w inxeimann & Associates, Inc. CONSULTMG CIVIL ENCINEERS • SURVEYORS - - . suirE zis (s�2) aso-�o90 (e�z) aeo-�o99 rnx Texos Englneers Reglstrotion Na 89 i�as Surveyors Reg�shation No. 100866-00 COPVRIGHT � 20222. Winkelmonn & Associates, Inc Scale : N.T.S. Date : 12�27�21 �wq. F�ie : Detention Pond.dwq Storm Event Qa WSE VM�, (ft3) VM,,,X, (ac-ft) 100 55.09 718.97 435,034 9.99 5 27.11 715.27 215,422 4.95 1 9.71 713.19 118,043 2.71 etention FORT WORTH, TEXAS SHEET ❑ on Nond-zUz.S-Uts-Uy_dwg z l ^`° , z 1 I � �a���DaaO �� a00a��a� D��aO�a� a�Da00aa � o �DDa0�a0 � e ���a00a� �DDa�Da� ��: EXHIBIT B 5 OF 22 "� Winkelmann & Associates, Inc. CONSVLTING CNIL ENGMEERS ■ SURVEYORS 6)50 HILLCREST PVSA DPoVE, SIIRE 215 (9)2) 490-)090 DALVS, iE%RS �5230 (9l2) s90-�p99 FnX Texas Engineers Regislralion No. 89 Texas Surveyors Reqistration No. 100866-00 COPIRIGHT �� 20222, Winkelmann & Asso<iates, In<. Scale : N.T.S. Date : 12�27�2024 �Wg. F�ie : Detention Pond.dwa 5�/q I T 4'-2�/u _ .�% 4'-0 MADE IN THE U.S.A. � AVAILABLE MATERIALS: MILD STEEL (NO FINISH)- WGT: 140.61bs. MILD STEEL (GALVANIZE�) - WGT: 140 61bs. STAINLESS STEEL - WGT: 140 61bs. ALUMINUM - WGT'. 4].S lbs. CUSTOM SIZES AVAILABLE AVAILABLE UPON REpUEST WITH: ACCESS PORT iCAST-IN STYLE FRAME WITH EM6ED ANCHORS �TRASHRACKS,mm LCP1�8 48"SOUARE CULVERT ,R�oEcoM A 69683 DETENT/ON POND 1 PROTECT/ON GRA TE FORT WORTH, TEXAS SHEET � e / / �' �� I ;' ' ; �' ►v ,,-�XHIBIT B (6 OF 22) � , _ , , , , � - ---- -- ; , �.- _ , � i � /� '� � _...... , � � � ;� � , ' � � �� =�' �� -- ,; � �� � �� � / ' �/ ' E �-�ze — , � � � ' � ;'� i ��.� , / � i / �� , I ' � -- -- � - — � , � � , � �' � � � -- � � -- /�I ' '� - � ' ,' ' ' S � / � / .� - ----�-- - - - I ' ' '� � ' 5 ' 1 0' � � � ,' / % � o i� �, � ; Scale ; ,�'� � � I ,�' � � „_100' ;' � � � �' � � � . ; �; �' -� - I . � � ,� , � ; � FLARED—WING FLARED—WING ' I y ' ,� �' HEADWWALL HEADWWALL % ���'� � � :� , SWFMA 6' CONCRETE 8�� � BOUNDARY % _ FLUME �� sTM RaMP��c� � _ _ _ , � I � � _ - _ , �I I _ ;� — , , , � � - - — /� � �- �' I I � ' � � .720.5 � � . � , � , � �� � - '�� ,, � � . , � � ��� �, - / — � � ��5 i , / ��� I � o / \J '� ,' �' % 23' i � �I o i , , � /' I � � '`� ; � 00�° i / � � D ENTION � i '� -1 � �', �� � I �' OND 2 DETENTIO�Y � � `� �i f, , POND ; � � ;EASEMEf� � 720.50 i i � � i i ii , i �� � � � � I � � � � �' II I � ' �' ...:. i � / 1�" ` / ; I � I � I , � � �' / � � � , - O � ..� .. .. ... - .. - — . ... .... . . .. . .. . ,, CONSTRUCT � ��P- _ � _ - OUTLET ' , - -- STRUCTURE ' EMERGENCY SPILLWAY � �P �N — — — STM — --- - OUTFALL TO , �0' WIDE x 1' DEPTH - -- X ' (GRASS) - _ � PROPOSED '� � — — — - PUBLIC STORM �fl � -� ; � -'— � ` , - � — SYSTEM -� � �` INSTALL RIP—RAP -' �, � , FOR EMBANKMENT - NO SAVED OR PROPOSED REFERENC EROSION E SHEET 13 TREES WITHIN SWFMA FOR HEADWALLS PROTECTION MAINTAINED AREA STRUCTURAL DESIGN I � , � � ��� Winkelmann & Associates, Inc. DETENTION POND 2 PLAN SHEET CONSVLTING CNIL ENGMEERS ■ SURVEYORS 6)SOHILLCRESTPWADRNE,SUREPIS �s,��.�-��so NWC CHAPIN ROAD & ALEMEDA STREET � DALVS, iE%RS 5230 (91]) s90-�p99 FqX Te.a= Engineers Regislralion No 89 FORT WORTH, TEXAS Texas Surveyors Reqistration No. 100866-00 COPIRIGHT '�� 20222, Winkelmann & Asso<iates, In<. Scale : 1'� — 100' Date : 12�27�2024 �Wg. F�ie : Detention Pond.dwa 735 730 725 720 715 710 705 700 35 30 25 20 '15 '10 05 00 0+00 1 +00 2+00 Pond2 B—B EXHIBIT B (7 OF 22) Winkelmann 3+00 4+00 FORT WORTH, TEXAS ��� & Associates, �n�. DETENTON POND 2 CROSS—SECTIONS CONSULTMG CIVIL ENCINEERS • SURVEYORS — s��.E z�s �s,�> .so—,o99 N W� �s,z� ,s _ .A. Texas En9'^eers Re9�olrotion No- 89 i�as Surveyors Reg�shation No. 100866-00 COPVRIGHT � 20222. Winkelmonn & Associates, Inc scale : N.T.S. Date : 12�27�2024 �wq. F�ie : Detention Pond.dwq etention 735 I 730 725 720 715 710 � 705 700 735 730 725 720 3000 P.S.I. CONC. M 715 �5� /3 Bars at �3 Bars a�� 6" O.C. 18" O.C. 710 6. 6' CONCRETE FLUME (INSIDE POND) N.T.S. 705 700 SHEET 7 on Nond—zUz.S—Uts—Uy_dwg 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 Pond2 A—A 740 735 730 725 720 715 710 705 700 695 740 735 730 725 720 715 710 705 700 695 —1+00 0+00 1+00 1+50 STM UNE f0 SCALE: i�_�0'VH. EXHIBIT B (8 OF 22) � Winkelmann �� & Associates, �n�. DETENTION POND 2 OUTFALL PIPE PROFILE �II��T CONSULTING CNIL ENGINEERS • SURVEYORS s�s°����reE=�P�A°R��E=°��E�,s �s��,.s°�°s° NWC CHAPIN ROAD & ALEMEDA STREET � �s�z, ,so_,o99 F� re;a E�9�ee�= Re9=,�a,�o� No 89 FORT WORTH, TEXAS Texas Surveyors Registratlon No. 100866-00 COPYRIGHT � 2020. Winkelmann & Associatas, Inc Scole : N.T.S. Date : 12�27�2024 Dwg. File : Detention Pond.dw Pro'ect No. : 78702 G: 787 02 ENGI�--KIVC; City Contracts SWFMA Detention Pond 78702—Detention Pond-2023-08-09-dwq , � � N � SAFETY GRATE FOR EMERGENCY RELI 0.42"X0.44" ORIFICE 0.60"X0.57" ORIFICE 0.56"x0.56" ORIFICE INSTALL: TRASH RACK EXHIBIT B (9 OF 22) "� Winkelmann & Associates, Inc. CONSULTING CNIL ENGINEERS • SURVEYORS , suirE zis (s�R) as0-�o90 (e�z) aeo-�o99 rnx �sz3o Texas Eng'inee�s Reglsl�alion No- 89 Texas Surveyors Registratlon No. 100866-00 COPYRIGHT � 2020. Winkelmann & Associatas, Inc Scale : N.T.S. Date : 12�27�2024 Dwg. File : Detention Pond.dwq REFERENCE SHEET 14 I S 0 M E TR I C VI E W FOR OUTFALL STRUCTURAL DESIGN N.T.S. DETENTION POND 2 OUTFALL STRUCTURE �II��T etention FORT WORTH, TEXAS on Pond-2023-08-09 dwq � �RONT VIEW REAR V EW N.T.S. N.T.S. Rating Table for HMS Elevation Storage Discharge Rate ft ac-ft cfs 707.00 0.00 0.000 708.00 0.09 1.264 709.00 0.59 1.952 710.00 1.77 2.454 710.67 2.95 2.741 711. 00 3.52 3.175 712. 00 5.56 4.890 712.12 5.81 5.020 713.00 7.71 6.616 714.00 9.97 7.851 715.00 12.33 8.867 715.22 12.87 9.074 716. 00 14.79 9.761 717. 00 17.35 10.572 718. 00 20.02 11.320 719.00 22.80 12.019 720.00 25.69 12.678 ORIFICE EQUATION Q = CA 2gH Q = ORIFICE FLOW DISCHARGE (CFS) C = DISCHARGE COEFFICIENT (0.6) A = AREA (ftZ) g= ACCELERATION DUE TO GRAVITY (322 ft/s H= EFFECTIVE HEAD ONTHE ORIFICE (ft) OUTLET STRUCTURE DETAILS STM Ever�t 1 STM Event 2 STM Event 3 1 -YR 5 -YR 100 -YR STORM PEAK STORM PEAK STORM PEAK ' WTR Surface Elev. 710.67 Elevation Difference 3.67 QMAXALLOWABLE �CfS� 2.7411 100 YR HefPective �ft) Area (ft�) 5 YR Heffective �ft� Area (ftz) 1 YR Herfea��e �ft) Hni-wsi Area (ft�) Al 712.12 1.44 5.02 Haz-wsz AZ 3.40 HAl-wsz 0.31 Al 715.22 3.11 9.0735 HA3-W53 A3 1 .14 HAZ_ws3 0.34 AZ 4.84 HAl-wss 0.31 Al 2.90 0.18 4.25 0.34 7.94 0.31 ORIFICE FLOW DISCHARGE RATE 100 YR Orifice Flow Qaa-wsa 1.51 5 YR Discharge QAZ_WSZ 1.75 QAz-W53 3.37 1 YR (cfs) Qai-wsi 2.74 Qni-wsz 3.27 Qai-wsa 4.19 QTo,�i (cfs) 2.74 5.02 9.07 SLOT OPENING DETAILS A1 A2 A3 Area (ftZ) 0.31 034 0.18 Width (ft) 0.56 0.57 0.44 Height (ft) 0.56 0.60 0.42 Storm Event Qrelease WSE STORAGE (cu-ft) STORAGE (ac-ft) 100 9.07 715.22 560,678 12.871 5 5.02 712.12 252,918 5.806 1 2.74 710.67 128,567 2.95 Q=C.L.H3�2 Q(cfs)(known)=240 H(ft)=1.0 L(ft)=70.0 L' Crest Invert Elevation=720.00' � 720.50' � 719.00' EMERGENCY SPILLWAY TRAPEZOIDAL WEIR (CIPOLLETTI) EXHIBIT B(10 OF 22) N.T.S. "� w inxeimann & Associates, Inc. CONSULTMG CIVIL ENCINEERS • SURVEYORS - - . suirE zis (s�2) aso-�o90 (e�z) aeo-�o99 rnx Texas En9'^eers Re9�olrotion No- 89 i�as Surveyors Reg�shation No. 100866-00 COPVRIGHT � 20222. Winkelmonn & Associates, Inc scale : N.T.S. Date : 12�27�21 �wq. F�ie : Detention Pond.dwq POND 2 DETENTION CALCULATIONS FORT WORTH, TEXAS SHEET 10 etention Pond 78702-Detention Pond-2023-08-09 dwg zI a-o r� a���Daa a00a��a D��aO�a a�Da00a �DDaO�a ���a00a �DDa�Da �,� � > 5�/q I T �M, 4'-2�/u _ .�% 4'-0 � MADE IN THE U.S.A. � AVAILABLE MATERIALS: MILD STEEL (NO FINISH)- WGT: 140.61bs. MILD STEEL (GALVANIZE�) - WGT: 140 61bs. STAINLESS STEEL - WGT: 140 61bs. ALUMINUM - WGT'. 4].S lbs. CUSTOM SIZES AVAILABLE AVAILABLE UPON REpUEST WITH: ACCESS PORT iCAST-IN STYLE FRAME WITH EM6ED ANCHORS �TRASHRACKS,mm LCP1�8 48"SOUARE CULVERT ,R�oEcoM A 69683 � 1'-2 �/te"0 . 1 1'-0 j 1 � MADE IN THE U.S.A. � AVAILABLE MATERIALS: MILD STEEL (NO FINISH) - WGT'. 24 9 Ibs_ MILD STEEL (GALVANIZED) - WGT'. 24 91bs. STAINLE55 STEEL - WGT: 24.91bs. ALUMINUM - WGT�. 8 41 Ibs. CUSTOM SIZES AVAILFBLE AVAILABLE UPON REpUEST WITH: �TRASHRACKS.< EXHIBIT B (11 OF 22 "� Winkelmann & Associates, Inc. CONSVLTING CNIL ENGMEERS ■ SURVEYORS 6)50 HILLCREST PVSA DPoVE, SIIRE 215 (9)2) 490-)090 DALVS, iE%RS �5230 (9l2) s90-�p99 FnX Texas Engineers Regislralion No. 89 Texas Surveyors Reqistration No. 100866-00 COPIRIGHT �� 20222, Winkelmann & Asso<iates, In<. Scale : N.T.S. Date : 12�27�2024 �Wg. F�ie : Detention Pond.dwa DETENT/ON POND 2 PROTECT/ON GRA TE FORT WORTH, TEXAS SHEET 11 1 n �2 6' TOVMIN. v95% STD. v �v PROCTOR DENSITY. RIPRAP DETAIL N.T.S. RIP RAP (Using Gregory Method) V= Yw= Ys= 9= �so= 13.12 ft/sec 62.4 Ib/ft3 165 �b/ft3 32.2 ff/sZ 0.842 ft 10.10 in 257 mm Dso = ,jV/C1.8 C29�Y5 —Yw)/Yw)os Based on Figure 3.12 -17 from iSWM Desiqn needs 18" Riprap and 6" Bedc RIPRAP GRADATIONS 18" THICKNESS OF RIPRAP SIEVESIZE PERCENT SQUAREMESH PASSING 21 INCH 100 �g INCH 65-100 12 INCH 35-65 g INCH 15-40 g INCH 5-25 EXHIBIT B (12 OF 22 "� Winkelmann & Associates, Inc. CONSULTMG CIVIL ENCINEERS • SURVEYORS - ' . sulrE zls (9)2) a9o-�o90 (9)2) 990-)099 !nx Texas En9'^eers Re9�olrotion No- 89 i�as Surveyors Reg�shotion No. 100866-00 COPVRIGHT � 20222. Winkelmonn & Associates, Inc scale : N.T.S. Date : 12�27�202� �wq. F�ie : Detention Pond.dwq .,—��.�� � BEDDING 18" Riprap Stability ��s5��5o+�ao���5)� 5.5 D85= �ao= ��s= 6" Bedding Stability �15�d85�5��15�d15�4� d85= d5o= d, 5= D,5/d85= D�s/d�s= �so�dso<40 3.93 OK 410 mm 257 m m 110 mm 32 m m 17 mm 6 mm 3.44 O K 18 OK 15 OK BEDDING GRADATIONS 6" THICKNESS OF RIPRAP SIEV E SIZE PERCENT SQUAREMESH PASSING 3 INCH 100 1-1/2 INCH 55-100 3/4 INCH 25-60 3/g INCH 5-30 No. �4 0-10 CREGORY CALCULA T/ONS FOR ROCK R/PRAP FORT WORTH, TEXAS etention SHEET 12 on Nond—zUz.S—Uts—Uy_dwg � o ir.inu onnv omo n n � __ �z _ _oo Dta OF TPLPE�� � I ����������������������������������������������������������� ��������������������������������������������������������I�� � � �• ����������������������������������������������������������� •' • ��������I�I������������III����I�I�I����I����I�������IIII��� • • _ ����������������������������������������������������������� ����9@�������������@������6@����@��9�����@@@���@@�9���@���� =. �����������������������������������������������������������:: �������AA�AA���������A�A�AAA������AA�AAAAA������A��AAAAAA���: 9������������������������������������6��������9������������:: ,-� 7 r' � P/ D r __..� _ r � N _ z �'� xi, _ � I � I m _ � < �. � � I i 'm ZOm I q.. � r 3..�J I Min Max O I 6"� � H r6� I m m t��mo 0 o NFQ<+ � � � �o m� m � " ~ �---\�-� - z - i N° - D • __/__ ___��Noam n n �I���=/��__ Y I e �o � � � � � 2 n a � � m 3 n y ; --- a m T fl — o n m ° _ � — 1 = n � T a y T C Z � z � � � o � � � � , . 0 �] T ]� — _ � � � aom A � � W � a� "� w inxeimann & Associates, Inc. CONSVLTING CNIL ENGMEERS ■ SURVEYORS 6)50 HILLCREST PVSA DPoVE, SIIRE 215 (9)2) 490-)090 DALVS, iE%RS �5230 (9l2) s90-�p99 FnX Texas Engineers Regislralion No. 89 Texas Surveyors Reqistration No. 100866-00 COPIRIGHT �� 20222, Winkelmann & Asso<iates, In<. Scale : N.T.S. Date : 12�27�2024 �Wg. F�ie : Detention Pond.dwa � �� _ I v�o�_ ' � n I� � �, m N L i � O < n < w x I I w Q_ � Na i ^._z. oN o.\j o _ � 6" � �, �-6„ � m < I a y Z � �F' O O O O O O _ X _ pOQ '_ - 30 10���������� 1������������ I����������� 1����������� 9���������������� ���������������� ���������������� ���������������� • TXDOT CONCRETE HEADWALL DETA/LS FORT WORTH, TEXAS m x I � � � W OT I N N SHEET 13 . . � . I I .i. � ._. ._. ... . � I I I. L_._L_ ntt0���ww'�'�doT.siate.Tx.us/fiw/specinT �n�=o' � � � � - .� 02fw.agn _� I "_m_�I - ��I � f�, � d � i m f' �� �` I I I__I I - m � I I I �� c'� � ' o� u��': I I I I � D _� � =,.IF�- z a ;I�� I I I � - m n s �� � —1 J--�—I—� ���, ��. �osm `�°� ' I _,i I I I " � � I y - �L'r�r._�-:- _- a - r � _ 6'. I 9" � � yi IA � v p r.'-� y° � m j P O N- � i.g, 7_6,. - 2 I �� �Tj �IS'S30'9tle0�c. e0"51512eD1c. ' m _ _ ar � o ar � o _ 0 � P 4 . � � � � - -oi5' Deo*n j 'D D ' r R m ^. n _ � z N o yo ��L m o � r~—� � jjj'���'''' 2 3'-9' D-ii' m_ �� N ��I ^ ��3.. �� - - �N - �N � � . • • ��������� � � •�•.' • ���������'• •. ��•• � • ��������� • � o k � � g " � � ��S I � ��� �- m�l N4, o °_: �n �%�yF 4 a,B.D 2,_2" � oz z._a. r'—'7 �o m Z a � � � m A n �� a y � o � 4 D = a r �r= �'��'�.\\. � ��� - � � �I� : � r �I� - ��� L___ -1I� � � :.:.,..���' � - F�_I m I I � 9 I � n� 'm � � 2 Y�'�i�J o I � ' ,\: - ~ i I � �.:.�; ., _ ��i� _ ��� � � '- - ��f s.' µ n, B, D 2, 2.' . C-IS" r �i�; i L N o�F_ y i m �� m F �I, � } �-o � n � r--� � ss> �135„9,. �3,. �N � r�-h ��� ---c s � �� �o � ~ m �N O �� 3 � o D � r os" m r'--'1 "� w inxeimann & Associates, Inc. CONSVLTING CNIL ENGMEERS ■ SURVEYORS 6)50 HILLCREST PVSA DPoVE, SIIRE 215 (9)2) 490-)090 DALVS, iE%RS �5230 (9l2) s90-�p99 FnX Texas Engineers Regislralion No. 89 Texas Surveyors Reqistration No. 100866-00 COPIRIGHT �� 20222, Winkelmann & Asso<iates, In<. Scale : N.T.S. Date : 12�27�2024 �Wg. F�ie : Detention Pond.dwa � m x _ � � � � � � N N SHEET 14 OUTFALL STRUCTURE DETA/LS FORT WORTH, TEXAS 1 � i ��� -0� —_ �II�_ T � I IP Y' ' � 95Z Q + �� l Q N� Z +(�n II � � 0 Nj W �\ �o�LL � I ' ' / a t� � ; � ; ; �. ,. �� l � � i _ " � ` � �'� a ��',��', �7 �, � �', � '' � LL, �, N'�, c���n i� �, ��,, �' � �'�,� '�,o �,o � �� \ � J � r . � � '` � i �� � \ �\ � N� , � � I ��\ \ . ` `� �\ �\ �\ � �\ �\ . �\ �\ . �I� �•.\` \\ �'�\• \�� �\ �\ � ` \��\� �\ �\ �� �I � ` \ \\ \ �h J �y� ,� .\� .�:'.'7C.�. `.l�1! \ ./. � . _,� .. �\ �� . � � �\ ' �\ \ `1 \ . � . \ \ \ . , \1 '1 . ��.� �� . . .\ \ �� II � I \\ \ � I 1 1 1 � I{ 1 I I' I \ I � i I I � I � � � �� � �..i i �. I i I d �. il i , _ , � g � � �"���' � �I. .� �_��'�J. � N / / b �(�' � � i� � J �OT iW I g� � /7 �/N LL � � m / �r LL ,' / / / / �� // / �. `� ,�E X H IBI T B(� 5 OF 22, "� Winkelmann & Associates, Inc. CONSULTING CNIL ENGINEERS • SUMEYORS 6]50 HILLCRfST PV3A DRIVE, SUITE 215 (9)]) 490-)090 �nLVS, lEWS p5230 (9�]) s90-]099 Far � as E g �eg/s( o. 89 .�.as 5 yro .egist No. 100B66 00 oP�, o �a���, �� � ti Sca�e : 7=300 Date e5 12�27�2( Dwg. File : 78702—ERO. dwg Proiect No. : 78702 -- -- w � I; _ � = J� �I - w o Q � � � �' u' �'3 , � , o ��-- i � i r W� ""Krl } "�; ;��,�" m'� i I�i z �, ' cn o � Q � V i "� 'I� � � � � �/ /� `,..\�� _ Q � / > J ll� � � / J�`a� !l\ o � 0\ `` � , � � � �, � � �\ \ � � � ������� ������ ' ""����i��I��i ����i����i ' �E�����£�e �����1 ��„ i � "e' ,�.. �� � ��a �a�. ��` ��►. , �a�� ��\. r�� ► � ��� � ,� U.rt , I M i� � a (V O ❑ OO�II J J O � W � � � � I �r LL � � � ____�___.i/ ,II �� ; - o= - w s �,�w wz _a �o � �a \ 1 , o ••• 1 6/ � ; :•: � u � :.: � � i I � � I I , i WR � W; '.; p3 il I Q _. k O i¢ iY , � 4 Z� II Z =U � �� i0� � �� �W ti�_ �i Ov N� W W UW O .- i �1 _ . Q �W � uU . pd \ �`I� > �� �- aOW Sp Wtip � I � n � Q �� 2 W� �� 2WJ. a o SE¢ W 3¢i:i ,�2 . .I Z� _ O �� ~p �1 2 W� � � � ¢ WS OW I` .�O n- � 2n 2W O�¢ 4 WZQ � � _. Q YC�� d � aQ p g � � 1 W�W O R R II. x2� �>W � Q2 4iri_� ��'e pi H I` W� oo�' Q -2� 3 � � o ox z z �� o� � E w�000-o 23 W S 4r�R � 2 2- � 4Z��J o J�� �W� m W�? �n �i 2�� s o �o = �a � � m� m � �Q �� oa� � w = ��< �a � �� p �__ � '"W= � � �� ���� Z�� i� O ¢ 4�W 2 32 � � O R� W � �� y� O�. p W _-�¢ � �_ -_ I vl� 2 kEXaxU22 2 � W S .`i �IY� W ZO o���a¢ ZN Z.ciui .�W2�"�S''iW�u � ���Q� ��g�., N ^i a v»��WW 'VnoD�¢j� Y OW 4-ro �30 � O � O 2 (/ O I /' �� J�� ? O t\ �..i _ �O 2 i ¢ W W W Z\ p n � O ¢ «i(F R G S a -T Q u U ? �p a�'.,l I,a' W Z 0 O 0 Z � (> � 3 i� W 2 ¢ a Q ��� Y I O 2 � �'� � 2 a O _ (Wi E � m a -'�� i� W W _ � I + � r Q � � R "� -- S J iW 50� OQ -] � o W Q�2 2W a�.-.� n ' - W o � ¢h '�'u o2z¢ ln�� ovi _ NWW � iY� � -:O.'� �00 O�O � R ci /I _ � l i� tt WQ��_. ORW¢ Kti� C� 2U �-R ;'G ¢2y _.w� 2 2i n>iZ 4 �� �Oi2 'C/ �G ....0 ��'02 3J� �2 �W�1��4 � � ' I .Q3 -�WWV 0 W _'W4 jo �Wn � Q�O�n�� S[04W2 Y� � �00 �R � �w= a � ox"w "^ ,� - �� Rh� OO�n¢� �C> W Y�� � �> O O d � mW U Z �ZOW �3on �S ¢o� � Q.Wjh m O¢Z O .�rl YZUOo�3 W3 Zp Q�Q 2�W�h 4 Ct OY R .�� i 2 � � �m " a` w� o`miz o � a _ _y . m....o , �a _ EROSION CONTRO� PLAN NWC CHAPIN ROAD 8c ALEMEDA STREET FORT WORTH. TEXAS SHEET 15 EXHIBI T B(� 6 OF 22� 12" MIN. j '�\�': .�. � ..... /��j'.r'--. / � �\ .; �°:; �/��� f . �•. •� / ��;���� ' � /\� , I • ROCK BAGS � � ///\� e e ��� . / ij��% '.� �•"° //\� : ._ i .. ' �� • ` Q j I ' ///�� • al� .._ . �\��\ . I. � — , ��� '��r.� \�i�\j � j��i • L 'T°'- . .\��\. � �� . . . �/� EDGE OF / GUTTER �FILTER FABRIC SECURED TO 2"x4" VnRE MESH BELOW A 1 J z%4 MESN J �� 1 ` ROCK BAG TO � � PREVENT FLOW � UNDER 2'x4' W1RE MESH 2"X4" WIRE WEIR CURB INLET PROTECTION NOTFS, GENERAL • DRAINAGE PATiERNS SHALL BE EVALUATED TO ENSURE INLET PROTECTION N9LL NOT DIVERT FLOW OR FLOOD THE ROADWAY OR PDJACENT PROPERTIE$ AND $TRUCNRES. ' INLET PROTECiION MEASURES OR DEVICES THAT COMPLETELY BLOCK THE INLET ARE PROHIBITE�. THEY MUST ALSO INCWDE A BYPA55 CAPnBILITY IN CASE THE PROTECTION MEASURES ARE CLOGGED. • A POSITIVE OVERLOW PATH SHALL BE CONSIDERED IN THE DESIGN OF INLET PROTECiION CONTROL MEASURED AT SUMP INLETS. CURB INLET PROTECTION ' MUNICIPALITY PPPROVAL IS REOUIRED BEFORE INSTALLING INLET PROTECTION ON PUBLIC STREETS. ' SPECIAL CAUTION MUST BE E%ERCISED WHEN INSTALLING CURB INLET PROTECTION ON PUBLICLV iRAVELED SiREETS OR IN DEVELOPED AREAS. ENSURE THAT INLET PROTECTION IS PROPERLY DESIGNED, INSTALLED AND MAINTAINED TO AVOID FLOODING OF THE ROADWAY OR ADJACENT PROPERTIES AND SiRUCTURES. • A TWO INCH OVERfLOW CAP OR WEIR IS REQUIRED ON ALL CURB INLET PROTECTION DEVICES. ' TRAFFIC CONES, WARNING SIGNS. OR OTHER MEASURES SHALL BE INSTALLED TO WARM MOTORISTS Wr1EN THE INLET PROTECiION MEASURES EXTEND BEYOND THE GUTTER LINE. • 2'X9" WEIR PROTECTION: BEND 'MRE MESH AROUND THE 2" X4" BOARD AND $TAPLE i0 THE BOARD. BEND N1RE MESH AROUND THE BOTTOM OF THE BOARD, THE CURB OPENING, AND ALONG THE PAVEMENT TO FORM A CAGE FOR THE ROCH. ROCK BAGS SHALL BE PLACEO PERPENDICUTAR TO THE CURB, AT BOTH ENDS OG THE WOODEN GRAME, TO DISRUPT THE FLOW AND DIRECT WATER INTO THE ROCK FILTER. STACK THE BAGS TWO HIGH IF NEEDEO. • 2"X4" WIRE (HOG w1REJ wEIR PROTECTION THE FILTER FABRIC AND WIRE MESH SHALL EXTEND A MINIMUM OF i2 INCHES PAST THE CURB OPENING ON EACH SIOE OF THE INLET. FILTER FABRIC SHALL BE PLACED ON 2" X a" WIRE MESH TO PREVENT THE TUBE FROM SAGGING INTO TME INLET. ROCK BAGS ARE USED TO HOLD THE WIRE MESH AND FILTER GFBRIC IN CONTACT 'MTH THE PFVEMENT. AT LEAST ONE BAG SHALL BE PLACED ON EITHER SIDE OF iHE OPENING. PnRALLEL TO AND UP AGAINST THE CONCRETE CURB. THE BAGS FRE INTENDED TO DISRUPT AN� SLOW THE FLOW ANO ENSURE IT �OES NOT GO UNDER THE FABRIG ADD BAGS IF NEEDED. ROCK BAC$ � 2" GAP � 2"%6" W1RE MESH FILTER FABRIC SECURED TO 2'X4' \//// ; � - � WIRE MESH \�\//��% � .. � \/\ ° . \��\� FILTER FABRIC � %\�% : SECURED TO 2 %4 � /\�/\�%��/\//\/ ���i .: WIRE ME2HGAP FIOR .e• //�%\�%�/2�x4 W1RE /\�j' �� OVERFLOw BETWEEN j�\� MESH \j/��/+ �:•� THROAT ANDNTOP ... \//�,. �\\..:� OF FABRIC .••. \n\� "' W lI1K@1ri1SRD & Associates, Inc. CONSVLTING CNIL ENGMEERS ■ SURVEYORS 6)50 HILLCREST PVSA DRNE, SIIRE 215 (9)2) 490-)090 DALVS, iE%RS �5230 (91]) s90-�p99 FqX 7exas Engineers Registration No. 89 r.os s���yo�s Re9�:aar;o„ No. rooess-oo COPYRIGHi O 2020, wnkelmann & Associates, Inc. Sca�e : N.T.S Date : 12�27�2� Dwq. F11e : 78702—ERO ,' �//�� EXISTING CURB _. ��/��. INLET (ALL TWES) ORT WORT CITY OF FORT WORTH, TEXAS 2"X4" WIRE WEIR CURB INLET PROTECTION EROSION CONTROL DETAILS FORT WORTH, TEXAS en wq REVISED 04-30-2021 01 57 13-D430 SHEET 16 12' MIN. FACE Of CURB .�j��\� ��. i\�%/��% :.��-. �iSWM�""TecM1nicalManual Construc�ion Controls iSWM��"TecM1nical Manual ConsVuction ConVols Rock Check Dams 2.1.1 Pllmary Use • Slone shall be well gratletl wi�h slone size ranging trom 3l0 6 inches �in tliameter far a check tlam Check tlams are usetl in lang tlrainage swales or tlitches to retluce erosive veloci�ies. They are typically height of 24 inches or less. The stone size range for check dams greater ihan 24 inches is 4 to 8 used in conjunction with other channel protection techniques such as vegetation Ilning anC Nrt inches in tliameter. einfarcement mats. Check tlams provitle limitetl trea�ment lo setlimen�-latlen �ows. They are more • Rock check tlams shall have a minimum lo dth of 2 tee� with sitle slo es of 71 or Flal�er. useful in retlucing flow velocitles �o acceptable levels for stablliza�ion methotls. Check tlams may be P w� P - usetl in cambina�ion with s�one outlet setliment traps, where �he check tlams prevent erosian of lhe swale Rock Bag Check Dams while the seaiment trap capmres sediment at the aownstream ena of the swale. • Rock bag check tlams shoultl have a minimum lop witlth of i6 �inches. • Bag leng�h shall be 24 inches to 301nches, wid�h shall be ib inches �0 181nches antl lhickness shall 2. �.2 Applications be 6 inches �0 8 inches antl having a minimum weigh� of 40 powtls. Check tlams are typically usetl in swales antl tlrainage tli�ches along linear projects such as roatlways. They ca also be used in short svrdles tlown a steep slope, such a wales tlown a highway • Minimum rock bag tlam heigh� af 12 inches woultl consis� of one row of bags s�acketl on top oi two embankmenl �o retluce velocities. Check tlams shall not be usetl in live stream channels. rows of bag. The dam shall always be one more rowwitle �han it Is hlgh, stacked pyremid fashlon. Check tlams shoultl be Ins�alled before the wnVibu�ing drainage area Is tlisWrbeq so as �o mitiga�e �he • Bags shoultl be (Iletl wi�h pea gravel. (I�er stone, or aggrega�e Iha� is clean antl free of tlele�erious eRects on the swale from the increase in runoff. It [he swale itself is gratletl as pah of �he construction material. activitles, check tlams are installed Immetllately upon <ompletion of gratling to cantral velocities in the • Santl bags shall no� be usetl for check tlams, tlue to �heir propensity to break antl release santl tha� is swale until stabilization is compleletl. transpohetl by the concentratetl 9ow in the tlrainage swale or tlitch. . Bag material shall be porypropylene, polyethylene, polyamide or mnon burlap woven fabric, minimum 2.7.3 Deslgn CI'itena unit weight 4-ounces-per-square-yartl, Mullen burst sirength exceetling 300-psi as determinetl by Genefal Cfitefia ASTM 03]86, S�antlartl Tes� Melhotl for Hytlraulic Bursting Streng�h of Textile Fabrics-Oiaphragm Bursting SVength Tester Method antl ultraviolet s�abiliry exceetling 70 percenL • Typically, �he dam height should be between 9 Inches and 36 Inches, depending on the material of which lhey are made. The heigh� of the check dam shall always be less fhan one-third lhe depth of • PVC pipes may be Installed through �he tlam to allow for mntrolled flow lhraugh �he tlam. Pipe �he channel. nc„�Itl be schetlule 40 or heavier polyvinyl chloritle (PVC) having a nominal internal diameler of 2 . Oams shoultl be spacetl such lhat the lop af �he tlovmstream tlam is at the same eleva�ion as �he �oe of the upstream tlam. On channel gredes flatler ihan 04 percent, check dams shoultl be placetl at a Sack Gabion Check Dams distance tnat aiiaws sman poois m mnn between eacn cneck aam. . Sack gabion check tlams may be used In channels wilh a mn�ribu�ing tlreinage area of 5 acres or . The �op of lhe side of lhe check dam shall be a minimum of 12 inches higher lhan �he mitltlle of the ess. tlam. In atltli�ion, �he sitle of �he tlams shall be embetltletl a minimum of 18 Inches In�o �he sitle of �he • Sack gablons shall be wrappetl in galvanizetl steel, woven wire mesh. The wire shall be 20 gauge dreinage tlltch, swale or channel to minimize the potential for �ows to erode arountl ihe sitle af ihe with 1 inch tliame�er, hexagonal openings. dam. • Wire mesh shall be one piece, wrappetl around �he rock, and secured lo itself on �he tlownstream • Larger flaws (greater than 2-year, 24-hour tlesign storm) must pass the check tlam wi�hou� causing sitle using wire ties or hog rings. excessrve upstream Flootling. • Sack gabions shall be staketl wi�h'/. inch rebar at a maximum spacing of �hree feet Each vnre sack • Check tlams should be used in conjundion with o�her setllment retlu<tion techniques prior �o shall have a minimum of hvo stakes. releasing flow oRsite. • S�one shall be well gratletl with a minimum size range from 3 to 6 inches In diameter. • Use geotexlile flter fabric under check tlams of 12 inches In height or greater. The fabric shall meet �he following minimum criteria: Ofganic Filfel TUbe Check Dams o Tensile SVength, ASTM D4632 Test Me[hod for Greb Breaking Loatl antl Elongation of • Organic flter tubes may be usetl as check tlams in channels with a contribu�ing tl�ainage a�ea of 5 Geotexliles, 250-Ibs. acreso�less. o PuncWre Rating, ASTM �4833 Test Melhotl for Intlex PuncWre Resistance of Geo�extiles, • Organic (I�ertubes shall be a minimum of 121nches in tliameter. Geomembrenes, antl Relatetl Protluc�s, 135-Ibs. • Filter material usetl vnthin Wbes to conshuct check tlams shall be limi�etl to mir, sVaw, aspen flber o Mullen Burs� Rating, ASTM D3786 S�antlard Tesl Me�hotl for Hydreulic Burs�ing SVength of antl other organic ma�erial with hlgh cellubse <ontenL The material shoultl be slow �o tlecay or leach Tex�ile Fabrics-Diaphragm Bursting S�reng�h Tes�er Me�hoQ 420-psi. nu[rients in s�antling wa�er. o F�oparent Opening Size, ASTM D4751 Tes� Methotl for Determining Apparent Opening Size of a • S�aking of flter tubes shall be a� a maximum of 4 foot spacing antl shall alternate through the tube Geo[ex�lle, U.S. Sieve No.20 (max). antl on lhe tlovmstream face of lhe Wbe. . Loose, unconfinetl soil, wootl chips, composl, antl other material �ha� can float or be transpohetl by . Unless supersedetl by requiremenis In thls section, filter Wbes and flter material sha0 mmply with ihe runoR shall not be used to construct check tlams. CheckDam CC-ib CM1eckDam CC-13 Revised 04I10 Revisetl OOI10 i5W M�"" Technical Manual ConsVuction ConVols ISW M�"' Techniwl Manual ConsiNction Conirols 2.0 Erosion Controls 2.1 Check Dam axcxaairvc �a�es F�ow Uescrip�ion: Check dams are small �3'Mi awa�MxMUMsoeovEe�� �—' I bar- -t gofl k ock � Eaosorvcorvlaoi \ j ba �"9 I ec9 9 filt t b pl ced . -L�_�� tl - ge I tlmc�h, / 9'�• They tl �he v I ty f II . � � ---_ L .`\ � con t t tl � ws p-tl I tetl . . y�M„� — �L bar f tl' ent d d the � � � I po�enTal far eros on of �he swale or . . . �� dtch. HEEiF�OW . � . KEYCONSIDERATIONS AVPUCATIONS . [s(ivv)tiNcxon DESIGNCRITERIA: � � o Perimeter Conhol � �� rry oucHourecenr e� • Heigh�s beN✓een 9lnches antl 36 in<hes Slo e Pro�ec[ion MUMovEauanrEuos � svnaNcaecoMMeNoeoav . Top of the tlownsiream tlam shoultl be at ihe sam ELEVAiIONSNXL�OVERU.POry � � � mnrvuFncniaea eleva�lonasthe�oeof�heupsVeamtlam SedimenlBarrier roP or �ovrFR ece. EC6ISOMETRIC PIAN VIEW AUVANTAGES / BENEFITS: Channel Protection �?s� • Retlucetl velocities in long tlrainage swales or ditches Temporary Stabilization . May be usetl wilh other channel protection measures Final Stabilization s�EEr . Provides some setllment removal Weste Management r`oW l\ DISADVANTAGE5ILIMITATIONS: HousekeepingPractices ��—,_` �_ `\/ • Cannot be usetl in live stream channels � . mmor Po�am9 �Ps�ream orme �ne�K aams Fe=0.30-0.50 . Extensive main�enance or replacement of Ihe tlams (Oepentls on soil type) � m rncru�rt requiretl atter heary �ows or high velocity �ows • Mowing hezartl from laose rocks if all rock is not removetl �MPLEMENTATION at end of consiruction CON9DERATIONS �� MNNTENANCE REOUIREMENTS: p Capital Casts Inspec�regularly • Maintenance • Remove sil� when il reaches approxima�ely % Ihe height of the tlam or 12 inches, whichever is less O Training EGBOVERLAPEXqMPLE p Sui�abili�yfo�Slopes>5% TARLETEDPoLLUlANiS aherConsideretions: G Setllmen� • None � Nutrients & Toxic Ma�erials o Oil 8 Grease G Floa�able Ma�erials Figure 2.] Schematics of Erosion Con[rol Blanketa 0 omerco�so-��uoowas�es e�os�oo comroi ainoke�s ec�e ene�w oam cc-iz aevisea omm Re��sea oano EXH/B/ T B � 7 OF 22 "� Winkelmann & Associates, Inc. EROSION CONTROL DETAILS SHEET CONSVLTING CNIL ENGMEERS ■ SURVEYORS 6)SOHILLCRESTPWADRNE,SORE215 �9,�,.�_�oso NWC CHAPIN ROAD & ALEMEDA STREET DALVS, iE%RS 5230 (91]) a90—�p99 FqX 17 7exas Engineers Registration No. 89 r.os =�,�,�,s Re9,sr,ar;o� �o ,00e66_oo FORT WORTH, TEXAS COPYRIGHi O 2020, wnkelmann & Associates, Inc. Sca�e : N.T.S Date : 12 27 2024 Dwg. File : 787�2—Ef�� Pro'ect No. : �87�2 wq i5WM1°'TecM1nicalManual Core�ruc�ion Conhols • Anchor Irenching shall be localetl along the top of slope of the installation area, except tor small areas vnthlessthan 2 percenislope. • Ins�alla�ion antl anchoring shall conform to �he recommenda�ions shown within �he manufac�urer's published IltereNre for the erosiom m�trol blanket Anchors (s�aples) shall be a minimum of 6 inches in leng�h antl 1 inch witle. They shall be matle of 11-gauge wire, or equivalent, unless Ihe ECB is intendedto remainin place with fnalstabilization and biodegrede. • Particular attention must be paitl to joinis antl overlapping material. Overlap along the sitles and al lhe entls of ECBs shoultl be per Ihe manufacturer's recommentlalions for site contli�ions antl lhe type of ECB being Inslalletl. At a minimum, lhe end of each roll of ECB shall overlap the next roll by 3 feet antl the sitles of rolls shall overlap 4 Inches. . At[er�mstallation,lhe blankets shoultl be checketl foruniform contactwith lhe soil, secu�i�y of�he lap join�s, antlfNshness ofthe staples withthe grountl. • When ECBs are installetl to assis� with establishing vegetatioR seetling shall be compleletl before installation of ihe ECB. Criteria for seetling are provitletl In Section 29 Vegetation. • Turt Reintorcement Mats shaultl be usetl insleatl ot ECBs for permanent erosion control antl for stabillzing slopes greater than 2:1. • ECBs are limi�etl to use in swales antl channels �hat have shear s�resses of less Ihan 2.0 pountls per square foot Turt reinforcement mats shall be used In open channels with higher shear s�resses. 2.3.4 Design Guidance and Specifications Speci(ications for construc�ion of Ihis item may be tountl In �he Stantlartl Specifications for Public Works Construction- Nohh CenVal Texas Council of Governmenls, Sedion 207.15 Erosion Control Blankels antl In Item 169 of the S�antlartl Specifca�ions for Construclion antl Maintenance oi Highways, Streets, antl Britlges (TxDOT, 2004). 2.3.5 Inspection and Maintenance Requirements Erosion control blanke�s shoultl be inspectetl regularty (a� leas� as oflen as requiretl by �he TPDES Construction Generel Permil) tor bare spo�s causetl by wea�her or o�her evenls. Mlssing or loosenetl blanke�s mus� be replacetl ar re-anchoretl. Check far e setlimen� tlepasitetl from runoff. Remove setliment antl/or replace blanket a ssary. In atlditlon, determine the source of ex<ess setliment antl implemenl appropriare measures ro con�rol �he erosion. Also check for rill erosion tleveloping untler �he blankels. If found repair the erotletl area. Determine �he source of water causing the erosion and atld mntrols �o preven� ils reoccurrence. 2.3.6 Example Schematics The following schemalics are example applica�ions of �he consUuclion control. They are In�entletl ta sist In untlerstanding ihe control's tlesign antl function. The schemalics a not for cons[ruc[ion. The designer is responsible for working with ECB anufacWrers to e re lhe proper ECB is specifetl basetl on the si�e topography antl tlrainage. Installation measures shoultl be tllc�aletl by lhe ECB manufacturer and are tlepentlen� on the type of ECB �installetl. Manufac�urers recommentlatians for overlap, anchoring, antl stapling shall always be followetl. Criteria shown here are appllcable only when they are more stringenl than ihose provitletl by ihe manufacturer. Erosion Control elankets CG2J ae��:ea oaim iSWM�M TechnicalManual Construction Controls 2.3 Erosion Control Blankets �.:.,.,, Descrip[ion: An conVol - -- blanket (ECB) 5 otemporary, � C tlegratlable, rolleds erosion conVol � �, . product ihat reduces soil erosion antl � assists in ihe establishmen� antl growth o( vegetation. ECBs, also �- �;� ^ s �, known as soll ratentlon blankats, ar Curb � nufa�cturetl by many p� SV �\ Erosion ntl re ompose�d p' ly f \ ConVo processetl na[ural g [' Is .__ \\� ti� �� Blenke� �hat are woven gluetl � [ Ily --_ ��-�� bountl toge�her wlh naNral fber netting or mesh on one or both sides. KEY CONSIDER.4170N5 APPUCATIONS DESIGN CRITERIA: Perimeter Con[rol • ECB selectetl based on slope,flow ra[e and length of Slope Protection • Specify preparation of soil surtace �o ensure uniform Setliment Barrie con�acl wi�h blanke� Channel Protec[lon • Ins�alla�ion antl anchoring according �o manufac�urers recommentla�ions Temporary Stabilization AOVANTAGES I BENEFRS: Final Stabllization • Holtls seetl antl soil in place until vege�a�ion is Mlaste Management eslablishetl Housekeeping Practices • ERective (or slopes, embankments antl small channels DISADVANTAGESILIMITATIONS: F2=O.90(Grounamver) . No� ro� �se o� smoes 9�eace� ma� zi o � �na��eis Fe=0.65 with shearstresses gree�erthen 2.� pountls persquare (Penmeterw/o vegefation) foof MAINTENANCE REQUIREMENTS: IMPLEMEN7ATION • Replace or re-anchor loosened blankets ��NSIDERA770N5 • Remove setlimen� tlepositetl on blankets • Capi�el Cos�s C Maintenance 7ARGETEDPOLLIf�ANTS o Training • Sui�abili�y for5lopes > 5% • Setliment O Nutrien�s 8 Toxic Matenals Other Consitlerations: O OII& Grease • Li/e expec[anry,partial tlegretlafion.antl mowing/ O Floatable Ma�erials aintenanceissues /or O OfherConsVuctionWaste ECBsleRin0laceaspartol finalstebilization Revisetl OOI10 XHIB/ T B�� 8 OF 22 w inxeimann & Associates, Inc. CONSVLTING CNIL ENGMEERS ■ SURVEYORS 6)50 HILLCREST PVSA DRNE, SIIRE 215 (9)2) 490-)090 DALVS, iE%RS �5230 (91]) s90-�p99 FqX 7exas Engineers Registration No. 89 r.os s���yo�s Re9�:aar;o„ No. rooess-oo COPYRIGHi O 2020, wnkelmann & Associates, Inc. Sca�e : N.T.S Date : 12�27�2� Dwq. F11e : 78702—ERO en �iSW M�M TecM1nical Manual Cons�ruclion Controls 2.3.1 Piimary Use Erosion conirol blankets (ECBs) ar used to holtl seetl antl soil In place until vegetatlon is established on tlis�urbed areas. They can be usetl on many types o(tlisNrbetl areas, but are parficularly eRective for slopes and embankmenis and In small drainage swales. ECBs seetletl for vegetation may be usetl as a perime�er con�rol. When used in combination wi�h other sedimen� barriers, such es siltfence ororganic fil�erNbes, blanke�s mey be usetl as a perime�ercontrol wi[h or withou[ vegetation. 2.3.2 Applicafions ECBs may be used on many types of dist�rbed areas but are most applicable on qrotlual to steep (2:1) cuVfillslopes antl�in swales antl channels wi�hlowto motlera�e �ow vebci�ies. In Ihese applicationsthey may provitle temporary s�abilize�ion by �hemselves o may be usetl wi�h seetling to provitle final stabllization. ECBs are also used to establish vegetation In channels where velocities are lessihan 6.0 feetpersecond. When seeded tor eslabllshment of vegetation, ECBs can be an eHective perimeter alon9lhe down slope sitle ofllnearconsVuctlon projech (roads antl utilltles). ECBs with vegeta[ion are also used as perimeter controls for new developmen�, particularty a� Ihe front on resitlen�iallots in new subtlivisions. ECBs are an effective aid in establishing vegete�etl fil�er strips. 2.3.3 Design Criferia • The tlesigner shall specify [he manufacNrer, type of er con[rol blanket ro be used, and tlimensionetl limi�s o( �installation basetl on �he sile topography antl tlrainage. • The type antl class of e control blanke� mus� be specifetl in wrdance with the anufac�urers guitlencefor�he slope o(�he ereato be pro�ec�etl.�he flowrale (sheetflow on cWfill slopes) or velocity (concentrdted �ow in swales) of stormwater runoff In contact in witM1 iM1e ECB, antl [he anticipa[ed lengih ofservice. . ECBs should meet [he applicable "Minim�m Pertormance S[andards for TxDOT" as publishetl by TxDOT in i�s "Erosion Control Reporl" antllor be lis�etl on �he most cu ren� a ual "Approved Produc[s List tor TxDOT" applicable to TxDOT Item 169 Soil Re[ention 8lanketnantl its Special Provisions. • ECBs shall be installetl verticalty tlown slope (across conrours) on cuUfll slo0es antl embankmenis antl along�he conlours(parallelto flow)�in swales and tlrainage tlitches. • ECBs designetl [o remain onsite as part of final stabllization shall have netting or mesh only on one side (�he exposetl sitle) of �he ECB. The ECB shall be inslalled wi�h Ihe side thal tloes not heve netting or mesh in contect with �he soil surtace. All materiels in the ECB, inclutling anchors, should be 100 percen[ blotlegratlable withln [hree years. • On cuVFlll slopes and tlrainage ditches or swales designetl to receive erosion con[rol blanke�s for temporary or final stabiliza�ion, ins�allation of the ECBs shall be �iniliatetl �immedia�ely efler completinq greding of�he slope or drainage way, end in no case laterthan 14 days afte� completion ofgratling [hese features. �o not delay ins[allation of ECBs on ihese highly-erotlible areas until comple�ion of construction ac�ivi�ies antl stabilization of�he remaintlerofthe site. • Unless �he ECB is seedetl to establish vege�a�ion, perime�er control applica� ons shall be limi�etl �o Ihihy toot wide tlrainage areas (i.e.linear consbuc�ion projec�s)(or an 8(oot witlih of ECB. When seeded tor vegetation, u e of EC6s for perimeter conVol shall follow ihe criteria in ihe Section 3.15 VagetaYad Fil[ar 5lrlps end Bui/ers. • Prior to the installation of the ECB, all rocks, tlih clotls, s�umps, roo�s, �rash antl any o�her obsVuctions that woultl prevent the ECB from tying in dlreIX con�ac� with �he soil shall be removed. Erosion ConVOI8lankets CG26 Revisetl 04I10 ISWM�M Tec�nicalManual ConsVuction ConVols 3.10.6 Example Schematics The following schematics are example applica�ions of �he construclion con�rol. They are �intendetl to assis[In understandingihe control's design antlfunction. The schematics are not for construction. They mey serve as e stahing poin� (or creating e cons�ruc�ion detail, butthey must be site adapted bythe tlesigner. In atldltion, dlmensions and notes appropriatefor �he applica�ion mus� be atltletl by Ihe tlesigner. Sil[Fence CC-146 Revised O4I10 EROSION CONTROL PLAN FORT WORTH, TEXAS wq SHEET �• i5W M�"" TecM1nical Manual Conshuction Conhols � Apparent Openin9 Siie, ASTM D4151 Test Metlrotl for Dete�m'ining Apparen� Open�ing Size of a Geo[ex[ile, U S. Sleve No. 30(max) to No. 100 (min). � Ulhaviole� Resisiance, ASTM DP355 Standartl Test Method for Deterioretion o( Geotextiles by Exposure ro Ligh[, MoisWre, and Heat In a Xenon Arc Type ApparaWs, Mlnimum ]0 percent. • Fence pos�s shall be steel antl may be T-section or L-sec�ion, 1.3 pountls per linear foot minimum, antl 4 feet �in length m�inimum. Wootl pos�s may be used tlepending on anticipatetl leng�h of service antl provitletl ihey are 4 feet in lengih minimum and have a nominal cross section of 2 Inches by 4 inches for pine or 2 Inches by 2 inches for hartlwoods. . Silt fence shall be supportetl by s[eel wire fence fabric as follows: 0 41nch z 41nch mesh sire, W1 4l1 4, minimum 14 gauge wire fence fabric; � Hog wire, 12 gau9e wire, small openings instelletl a� bottom of silt fence', o Stantlartl 2�inc� x 2�inch c�ain link fence fabric, or o Other weltled or woven s[eel fabrics consisting of equal or smaller spacing as that Ilstetl herein antl appropriate gauge wire to provide suppoh. • Silf Fence shall consis� of syn�hetic tabric suppohetl by wire mesh end steel posts set a minimum of 1-foot tlepYh antl spacetl not more ihan 6-feef on cen[er. • A 6 Inch witle Vench Is to be cut 6 Inches tleep a[ ihe toe of the fence to allow fhe tabric fo be laid below the surtace antl backfilletl wiU compactetl earih or gravel to prevent bypass of runoff untler ihe fence. Fabric shall overlap a� abutting ends a minimum of 3 fee� and shall be joinetl such Ihat no leakage or bypass occurs. If soil conditions prevenl a minimum toe-in dep[h of 6 Inches or Installation of support post ro tlep[h of 12 inches, silt fences shall not �e usetl. • Suffcient room for �he operation of sediment removal equipment shall be provitled behHeen the silt fence antl o�her obstructions in ortler �o properly main�ain �he (ence. • The las� 10 fee� (or more) at the entls of a line of sill fence shell be lumetl upslope to preven[ bypass of stormwater. Additional upslope runs of silt tence may be neetletl every 200 to 400 Ilnear feet, depend�ing on �he traverse slope along �he line of sil� fence. 3.10.4 Design Guidance and Specifications Speci(cations (or construdion of �his i�em may be (ountl �in lhe S�antlard Speci(cations for Public Woilcs Consiruc[ion - North CenVal Texas Council of Governmenis, Section 201.5 Silt Fence and In ihe Stantlard Speci(cations for Construction antl Main�enance of Highways. Siree�s antl Britlges (Tx�ot 2004) I�em 506.2.J antl I�em 506.4.C.9. The American Sociery Por Testing antl Ma[erials has establlshetl s[antlartl specifica�ions for sil� fence ma�erials (ASTM D6461) antl sil� fence -installa�ion (ASTM D6462). 3.10.5 Inspection and Maintenance Requirements Silt fence shoultl be inspec�etl regularly (a� least as o�en as requiretl by Ihe TPDES Const�uc�ion Generel Permi�) for builtlup of excess setliment, untlercutlinq, sags, and other failures. Setllmen[ shoultl be ovetl before i� reaches half �he heigh� of �he fence. In atldi�ion, tletermine �he source of excess etlimen� antl �implemen� appropria�e measures to control the erosion. Damaged or clog9etl fabric mus[ be repaired or replacetl as necessary. SiltFence CC-145 Revisetl 04110 i5W MTM TecFnical Manual Construc�ion ConVols 3.10 Silt Fence oe:�.�pno�: n suo rence mnss�s oi �---�, oa�mapearea geo�enae r�mm:�vaonea ny �.e me:n aqre� �� �m netling orother backing s[re�chetl beNreen . ag, metal posis wih iM1e low dg f Ihe 5 S%Fance � �bresecurelyembetltletl' - h inihe / sol. T�e fence -s typ Ily I ca�etl �' tlovmslream of d'sturbeE a rcept ShbitizeeArea .��� �unoM'n ihe fortn of she t A . A silt knce provtles bo�M1 (Itrat tl �me hr S�� setliment setting by retlucng �M1e velocty 1(EYCONSIDERATIONS APPLICATIONS DESIGN CRRERIA: Per me�er Confrol • Mas mum dra nage area of 0 25 acre per 100 I near feet ot silt Slope Protect on fence Sedimen[ Barrier • Maximum 200 fee� tlistance of �ow �o sil� fence; 50 fee� it slope exceeds 10 percent CM1annel P�otec�ian • Minimumfabricoverlapof3feetalabuttin9ends',joinfabricto TemporaryStabilization preven�leakage • Turnendofsil[fencelineupslopeaminimumofl0teet FinalS�abiliza�ian • Install stone overPow structure at low poinis or spacetl at Waste Managemenf approxima�ely300feetifnoapparentlowpoint HousekeepingPrac�ices ADVANTAGESIBENEFITS: . ewoom�wimeao:m�rea�:neeonow Fe=0.50-075 • Most eReclive wi�h coarse to silry mil rypes (Oepends on soil type) OISAOVANTAGE51 LIMITATIONS: . L'mtedeXectvenesswt�claysolstluetoclogging IMPLEMENTATION • Localizetl ilood ng tlue to m nor pontling at ihe upslope sitle of �ONSIDERA110N5 tM1esitfence p CapiWlCosts • Not for use as h k tl ' les or low areas subled to M_ cenirztetlfio ance N�o�t for use wli 'S d' � g prevent a m n mum [oe In p 7- • d pih of 6-n h or'n tallat on of suppo� posis to a tlepih of 12-ncM1es G SUUblityk�5lopes>5°o • Can fail sirucNrally under heavy stortn flows, creating maintenanceproblemsantlretlucingeRecliveness O�M1erLonsitlera�ions: MAINTENANCERE�VIREMENTS: • Ellectso{pondingorMe redirection oiflaw anro • Inspeciregularty aEjarentaieasantlpmperiy . Repairuntlercutling,sagsando�Ferfencefailures • Removesetlimen�beforeitreacM1esM1alt�M1eM1eigM1�oftM1efince TARGETED POLLUTANTS • Sediment O Nuhien68ToxicMa�enals O 0118 Grease G FloaGble Materials O OlherConstructionWastes Sil�Fence Revised 00I10 EXHIB/ T B( � 9 OF 22 "� w inxeimann & Associates, Inc. CONSVLTING CNIL ENGMEERS ■ SURVEYORS 6)50 HILLCREST PVSA DRNE, SIIRE 215 (9)2) 490-)090 DALVS, iE%RS �5230 (91]) s90-�p99 FqX 7exas Engineers Registration No. 89 r.os s���yo�s Re9�:aar;o„ No. rooess-oo COPYRIGHi O 2020, wnkelmann & Associates, Inc. Sca�e : N.T.S Date : 12�27�2� Dwq. F11e : 78702—ERO CC-103 ISW M�M Techniral Manual Construction ConVols 3.10.1 Primary Use Sil� fence is normally usetl as a perime�er con[rol on �he tlown slope sitle of d�isturbetl ereas antl on side slopes where stormwaler may runoff �he a� It is onty feasible (or no cenire[ed, shee[ ilow conditions. It it becomes necessary ro place e silt fence where concen[retetl flows may be occur (e.g. where hvo sill fences join at an angle, o r channels or gullies�, i� will be necessary �o einforce the silt fence a� �ha� erea by a rock berm or entl beg bertn, or o�her s�ruc[ural measures iha[ will supporl ihe silt fence. 3.10.2 Applications Sllt fence is an economical means to Veat overland, non-concenireted flows for all [ypes of prqects. Silt fences are used as perimeter conhol tlevices for both si[e tlevelopers antl linear (roatlway) type projecis. They ere most eHec�ive wi�h coarse to silty soil lypes. Due to the potential of clogging antl limi�etl effectiveness, silt fences should be used with caution In areas ihat have predominantly clay soil rypes. In �his latlerinstance, a soils engineer or soil scientist should conflrm ihe s�itabiliry of sil[fence for [hat application. Atltli[ional conlfols may be neetled �o remove fine sil�s antl cley soils suspentletl �in stormwater. 3.10.3 Design Criteria . Fences are to be wns[ructetl along a line of constant elevation (along a contour Ilne) where possible. • Sil[ fence can In[ertere wiU consVuctlon operations; iherefore, planning of access rou[es onro ihe site is cri�ical. • Meximum tlrainage aree shall be � 25 ecre per 1001inear fee� of siltfence. • Meximum flowto any 20 (oot section of silt (ence shell be 1 CFS. • Maximum tlistance of Flow to sil� fence shall be 200 feet or less. If �he slope exceetls 10 percent the flow dislance shall be less than 50 fee�. . Maximum slope adjacenl lo the fence shall be 2:1. • Silt fences shall not be usetl where lhere �is a concentra�ion of wa�er in a chennel, dreinage ditch or swa e, nor shoultl it be usetl as a conVol on a pipe ouffall. . If 50 percen[ or less soil, by weight, passes [he U S. S[andard Sleve No. 200; select the apparen[ opening sire (A O S.) to retain 85percen[ of Ihe soil. • If 85 percen� or more of soil by weight passes Ihe U.S. S�antlartl Sieve No. 200, silt fences shall not be used unless the soil mass Is evaluated antl deemed suitable by a soil scientist or geotechnical engineer concerning ihe erotllbliry of [he soil mass, tllspersive characteristics, antl ihe potential grain- size charac�eris�ics of Ihe material that is likely �o be ero0etl. . Stone overFlow struc�ures or o�her outle� conVol tlevices shall be installetl at all low points along �he fence or spaced a[ approxima�ely 300 feet'if [here Is no apparen� low point. • F'il�er s�one for oveRlow sVuclure shell be 1 i'inches washed stone con�aining no flnes. Mgular shaped stone Is prefereble to rountled shapes. . Sil[ fence fabric must meet the following minimum criteria'. o Tensile Streng�h, ASTM D4632 Tes� Me�hod for Grab Breaking Loatl and Elongation of Geotextiles, 90-Ibs. v Puncture Rating, ASTM D4833 Test Methotl for Index Punc�ure Resis�ance of Geotextiles, Geomemb�anes, antl Relatetl P�otlucls, fi0-Ibs. o Mullen Burs� Ra�ing. ASTM D3186 Stantlard Test Me�hotl for Hytlraulic 8ursting Strengih of Textile Fabrius-Dlaphragm Bursting Strengih Tes[er Method, 280-psi. SIItFence CC-144 Revised 04I10 i5W M�M TecM1nical Manual ConsUuction Controls cE�M��HOEGHi FORFENCEPOST v aeOVE Ex . �'TM) � � FE�E PoSi oF RocK eacNF LL � w aM H EMeew,��r t � 3� \ — IN w � � iFErvcN F�RIciOE-iN SILT FENCE EXAMP gE FE CEON %�s� r � SILTFENCE 5 ONE / ��� pFSLiFENCE 13]9Fii[�LIiIX Figure 3.28 Schematics of Sil� Fence EROSION CONTROL DETAILS FORT WORTH, TEXAS SHEET 19 iSWM�M TecM1nical Manual Conslruction Conirolz Table 3.9 Minimum Exi[ Dimensions MIn.Wid�h MIn.Length DIrt�u6MArea dExh ofExh <1Acre i5feet 20feet > 1 Acre but � 5 25 fee[ 50 feet Acres z s n�.es ao ree� so ree� • Ifawheelcleaningsystemis�setl,�hewitllM1of[hes[abilixetlexi�mayberetlucetltofunnellrefficin�o [he sys�em. Refer to Section 3.16 Wheel Cleaning. 3.11.4 Design Guidance and Speci(ications Specifications for consVuction of this item may be fo�ntl In ihe Standard Specifications for Publlc Works Consfruction - Norih Cenfral Texas Council oi Governmenis, Section 201.10 SWbillzetl ConsVuction Enirance and in tFe Standartl Speciflcations for ConsVuction and Maintenance of HigM1ways, SVee�s and 9ridges (TxDOT 2004) Item 506 2.E antl Ilem 506 4 C 5. 3.7 LS Inspection antl Maintenance Requlrements Cons[ruction exits shoulE be inspecteE regularly (a[ least as oXen as requireC by ihe TPOES Conshuction General Permit). TFe stabilired consVuction exit sFall be maintained In a condllion Na� prevenh hacking or ilow of sediment onto paved surfaces. Periotlic re-grading antl top dressing with adtlitional s�one mus� be done to keep iFe efficiency of [he exit from tliminishing. The rock shall be re-gatled wM1en ru6 appear. Adtlltional rock shall be added when soil Is sM1owing iM1rough iFe rock surface. AdGitionalconirols are needed ifinspec[ions reveala properlyinslalletl and maintainetl exi�, butVacking of soil ou�side Ihe conshuction area �is still evitlenL Adtli�ional mn4ols may be daily sweeping of all mil spilletl, tlroppetl, or tracketl on�o public righ�s-of-way or �M1e �ins�allation o� a wtieel cleaning sys[em. 3.11.6 Example Schematics TM1e following scM1ematics are example applica�ions of Ihe cons�ruc�ion conhol. TM1ey are in�endetl �o assis� in untlers�anding �M1e conhol's tlesign antl func�ion. The schematics are not for consrcunion. They may sene as a s[arting point for creating a construction tletail, but �hey mus� be si�e atlap�etl by �he tlesigne�. In atltli�ion, tlimensions antl no�es app�opria�e tor iM1e application must be atltletl by tFe designer. eee:ee oano�w�eo� E.e cweo ISW M�M TecM1niwl Manual Conslruction ConVols 3.11.1 Primary Use Stabilizetl coretruMion exi[s are usetl ro remove soil, mutl antl other matler hom vehicies ihat drive oH of consVudion site onro public sireets. Stabilizetl exits retluce Ihe neetl to remove sed'iment from sheets. W M1en usetl property, �M1ey also con�rol ��af(c by tlirec�ing veM1icles a single (or iwo fo� la�ge� si�es) loca�ion. Controlling traffic onto antl off of ihe site retluces iM1e number antl quantity of tlisturbetl a and provitles pro�ec�ion foro�hersetlimen[conhols by tlecreasing�he po�en�ial forvehlcles[o tl�iverove�Ne control. 3.112 Applications Stablllretl conshuction exics are usetl on all consiruction sites with a disWrbetl area of one acre or larger and are a recommendeE practice for smaller construction si[es. A stablllzed exil ls usetl on intlividual esitlentiallots untilihe driveway is placed. Stablllzetl consVuc[ion exits may be used in conjunction with wM1eel cleaning systems as describetl In Secfion 3. )6Wheel Cleaning Sysfems. 3.11.3 Design Crite�ia • Limitsi[eaccesstoonerouteduringconsirudion,ifpossible',�voroutesforlinearantllaryerprojeds. • Prevent Vaf(c from avoiding o shortcutting iFe full IengiM1 of [he co i[ by Installing barriers. Barriersmayconsis�otsilttence,consVuctionsafetytencing,orslmllarbarreiers. • Oesign IM1e a s poin��s) �o be a� Ihe upslope sitle of ihe cons�ruction site. Do no� place wnsVuc�ion access a� Ihe lowest poin� on �he mnsVuction si�e. . Stablllred consVuction exits are ro be construcfed such tM1at tlrainage across �he exil is directed to a Volletl, stabilired oullet onsite with provisions for storage, proper Flltration, and �emoval of wash • Theeexi� mus� be slopetl away from �M1e pavetl surtace so Na� s�ormwater trom tM1e si�e tloes no� tliscM1arge �M1rougM1 �he exi� onto roatlways. • Mlnimumwidihofexitshallbei5feet. • The consiruction exit ma�erial sM1all be a m m(hickness of 8�incM1es. The stone or recycled mncre�e usetl sM1all be 3 to 5�inches in size with litlle or no (nes. • Thegeotextiletabricmustmeet�Fefollowingminimumcriteria: = Tensile SVengiM1, ASTM 04632 Test Method for Grab Breaking Loatl and Elongation of Geotextiles,30016s. � PuncWre Shengih, ASTM D4833 Tesl Methotl for Index PuncWre Resistance of Geotextiles, Geomembranes, and Related Products, 12016s. o Mullen Burst Rating, ASTM 03]Bfi Stantlard Test Method for Hytlraulic Burs�ing Sireng�F of Textile Fabrics-Olaphragm Burs[ing SVeng�F Tester Me[hod, 600 psi. � Apparent Opening Sire, ASTM �4]51 Test MetFotl for De[ermining Appa�ent Opening Size of a Geo[extile, U S. Sieve No. 40 (max). • Rock by i�self may no� be sufficien� �o remove clay soils from wM1eels, par�icularly In we� condl�ions. When ne ssary, vehicies must be cleaned to re sediment prior to antering paved roatls, sireets, or parking lots. Refer to SecHon 3. �6 Wnee� Geanin9 5ystems for adtllllonel conirols. • Usingwa�ertowashsetlimentfromstree�sisprohibi�etl • Mlnimumdimensionsforiheslabillzedexitshallbeasfollows'. Re�s�ea oan��o-�n�a� e.,e caiae ISW M�M TecM1nicel Manual Conshuclion Canlrols ISW M�M Tachniwl Manual ConsVuction ConVols 3.11 Stabilized Construction Exit ;, cP � � S[ blzetl �0 � � Con t tonExit �j� � _... ....; I. e i / /��as � �� L2ngth . KEYCONSIDERATIONS vMicF correla eseb9imlFlc�volume o s¢e o� tlisturbetl SroneM3ro5in tan Y • AdE a wM1eel clean'ng syztem wM1en inspections reveal ihe s�aen��a e.�� aoes �o� a,e�e�r o-a�kmg Direcis Iraific�to a�conirolletl access Oo nt� • Proted�z ofl�er sed'ment conirols by I'ming I�e area • EXecO ene apd OendeN onTlm!f'n9 �n9resz and e9ress b :we��r�:aa a.n aay:onromo�9,wn��imivm�rei�o�e��ro�: �remOVe aHceReouiRemervrs: re9�larlyfi �he �oiJ area between tM1e racks is visible on iM1e surface, • Penotlicall��re9�tla anE bp Erass wi1M1 atltlltional sbna �o TARLETEDPOLLIRANiS G Setliment O Nutnents&ToxicMaleriels OII 8 Grease D p A b'I' d p d f h tl yltl h k ' I pl d g �I (ler I F d'Idg 'I d F tlbs f [o e d veh'cle tr prior u�ng [he t cton t. Th blect �s to '' e eh t k g f so;l o publ'c ro d ays Wnere -t -II be APPIIG110N5 enme�erConhol Slope Pro�ection Setlimen� Berti¢! CM1annelPro�ection Temporary Stabllizatlon as e enlagement Housekeeping Prac�ices Fe=NIA IMPIfMENTATiON CONSIDEFATIONS cannaico:m Maintenance o r�a�omg o SuitebilirybrSlaDes>5% . �erNonesiJeraOans. XH/Bl T B(20 OF 22 w inxeimann & Associates, Inc. CONSVLTING CNIL ENGMEERS ■ SURVEYORS 6)50 HILLCREST PVSA DRNE, SIIRE 215 (9)2) 490-)090 DALVS, iE%RS �5230 (91]) s90-�p99 FqX 7exas Engineers Registration No. 89 r.os s���yo�s Re9�:aar;o„ No. rooess-oo COPYRIGHi O 2020, wnkelmann & Associates, Inc. Sca�e : N.T.S Date : 12�27�2� Dwq. F11e : 78702—ERO en �� � �,�s s� � w�a CuculATorvs / �/ '/ � ROPD o / � � � noN � `ewsrir�ccAnoe F��reRrnaAic anveosur+r Figure 3.29 SCM1ematics of S�abilizetl Conshuc[ion Exit SteblllzeE Conziructlan Exlf CG�51 EROSION CONTROL DETAILS FORT WORTH, TEXAS wq SHEET � 0 Drainage Calulations 1 (Fully Developed) RUNOFF �RNG. AREA COEFFICIENT 11 qi ii 4��� I��m Qinn AREA (AC.) � (IN�HR) (CFS) (IN�HR) (�FS) (IN�HR) (CFS) ix I 1.vo I oeo I a.oe I a.ze I esi l e.xe I sza I e��a 25 I 1.]80 I 0.90 I 4.06 I 3.33 I 6.51 I 5.33 I 9.24 I 7 57 26 0.910 0.90 Natc 4'x4'G.i. @SA6 4'x4' G. i. @ SA6 4'x4' G.i. @ SAG 4'x4' G.i. @ SAG 4'x4' G.i. �v SA6 4'x4' G.i. @ SAG 10' CI. on 6rade S' C.I. @ SAG 5'CI. @SAG 5' C.I. �V SAG S' C.I. @ SAG 5' C.I. @ SAG 5' C.I. @ SAG 5'CI. @SAG 10' CI. on Grade 10' CI. on Grade io' c. i. �u sa� io' c. i. �u sa� 10' C.I. @ SA6 10' C.I. @ SA6 10' C.I. @ SA6 10' CI. on Grade 10' C.I. on Grade 5' C.I. @ SAG 4'x4' G.i. �V SAG 4'x4' G.i. @ SA6 4'x4' G.i. @ SA6 4'x4' G.i. @ SA6 4'x4' G.i. �i� SAG 4'x4' G.i. @ SAG 4'x4' G.i. @ SAG 4'x4' G.i. @ SAG 5'CI. @SAG 5'CI. @SAG 5' C.I. @ SAG 5' C.I. @ SAG 5' C.I. �V SAG 5' C.I. @ SAG 5' C.I. (� SAG Drainage Calulations 2 (Fully Developed) DRN6. AREA RUNOFF Il Ql I.� Qla I�,� Qlao AREA (q�) COEFFCCIENT (IN/HR) (CFS) (IN/HR) (CFS) (IN/HR) (CFS) Note 42 0.250 0.90 4.06 0.91 6.51 1.46 9.24 2.08 5'CI.@SA6 43 0320 0.90 4.06 1.17 6.51 1.87 9.24 266 5'CI.@SAG 44 0.090 0.30 4.06 0.33 6.51 0.53 9.24 0.75 5' C.I. @ SA6 45 0.210 0.90 4.06 0.77 6.51 1.23 9.24 1.75 5'CI.@SA6 46 0.2]0 0.9� 4.06 0.99 6.51 1.58 9.24 L25 10'C.I.on6rade 47 0.630 0.90 4.06 2.30 6.51 3.69 9.24 5.24 10' C.I. on 6rade 48 0.4G0 0.90 4.OE 1.G8 G.�l 2.]0 9.24 3.53 10' C.I. on Gratle 49 0.230 0.90 4.06 0.84 6.51 1.35 9.24 1.91 5' GI. (a1 SA6 4'x4' G.i. �v SA6 4'x4' G.i. (d SA6 GO 1.930 61 1.270 62 1370 63 1.420 64 0.3 W G� O.1G0 �� o.sw G7 0.920 68 0.950 69 O.S80 70 1.230 71 0.�30 ]2 0.2� ]3 0.240 �a ano 75 0.110 0.90 0.30 0.90 o.eo 0.90 o.eo o.eo 0.90 0.90 0.90 0.90 0.90 o.ea o.eo o.eo 0.90 ������ ' �'� '�" ��' �� ' ��' ����� ������ �� '���� '������ '������ ������ ' ��' �' ���� ' ��' ����� � '����� ����'' �� ������ ������ Sd C.I. @ SAG 10' C.I. @ SA6 10' C.I. @ SA6 10' C.I. on 6rade 5'C.I.@SAG � C.I. �N SAG 4'x4' G.i. @ SAG 4'x4' G.i. @ SAG 4'x4' G.i. @ SA6 4'x4' G.i. @ SA6 4'x4' G.i. @ SA6 5'C.I.@SAG 5' C.I. �i� SAG s� c i. �a sn� 5' C I. [ SAG 5'CI.C�SAG 80 0.280 0.90 4.06 1.02 6.51 1.64 9.24 2.33 Sl 0.110 0.90 4.06 0.40 G.51 0.G4 9.24 0.91 82 3.650 0.30 4.06 13.34 6.51 21.39 9.24 30.35 S3 1.980 0.90 4.06 7.23 6.51 11.W 9.24 1G.47 "� Winkelmann & Associates, Inc. CONSULTMG CIVIL ENCINEERS • SURVEYORS . suirE zis (s�2) aso-�o90 (e�z) aeo-�o99 rnx iexas5�En9ineers Re9�sfrafion rvo 89 lexas Surveyors Regishation No_ )00866-00 COPMIGHT O 2020. Winkelmonn & Associafes. lnc scale : N.T.S Date : 12 27 2024 Dwq. File : 78702- DAM 5' C.I. @ SA6 10' C.I. on Gratle Detention Pond 2 EXHIBI T B(22 OF 22) Detention Pontl 1 SITE DRAINAGE AREA MAP- SH�,�,T FORT WORTH, TEXAS 22� � RW6 NOTE FROM FALKOFSKE: This plan was developed directly from WINKLEMANN & ASSOCIATES, INC. POND GRADING PLAN (PRIVATE) DATED DECEMBER 26, 2024 SHEET NO. C-24.05. This plan is for the sole purpose of showing what retaining wall sections to use where and to comment on the site as necessary with regards to the retaining walls. Contractor shall review final Civil Plans for other notes with regard to the site prior to constructing Masonry Stone Retaining Wall. � FALKOFSKE ENGINEERING, INC. GENERALNOTES 1. Design 1.1. Design Codes IrRerna�ional Building Code, 2015 Edition 1.2. Geotechnical Report Firm: Reed Enoineerinq Group ReporiNo. 23809 Dated: October,2021 Allowable Bearing Capacky 2500 osf and 4000 psf 1.3. Design Parameters Soil Parame�ers: Sol Type' Friction Mgle Gohesion (psf) llnd WeigM (pcf) Rateined Bac�ll (On sita clay) 28 deg 0 psf 120 pcf Founda�lon Solls (2600 psQ 28 deg 0 psf 120 pof Foundation Soils (4000 ps� 35 deg 0 psf 135 pcf 'See materials below for a descrip�ion of each Soil Type. Factors of Safety: EMernal Stabiliry Minimum Factor of Salety Against Base Sliding (Static Condition) 1.5 b. Minimum Fac�or of Salety Against OverWrning 2.0 Minimum Factor of Satety Agains� Global Stabiliry 1.5 d. Minimum Factor of Safety for Bearing Capacity 3.0 Deslgn Loading: Lateral earth pressures are calculated using Coulombs Lateral Earth Pressure Theory. Designs have been pertormed to accept loading per ihe proposed loading conditions based on the Civil Grading Plans. A live loading of 250 psf has been used for all walls supporting areas sublect to frelane loading. Retaining walls should not have solid fence (such as wood fence) placed on mp of wall other ihan that shown on these plans. Retaining walls shall not have additional surcharge placed above wall other than ihat shown on ihese plans. Retaining walls shall not have slope a� base or top of wall �hat exceed �hat which is shown on �hese plans. The retaining walls no�ed above require special design. 2. Materials 2.1. Soil Types Retained BacMill On site dayey soils a.b. Properly compaded orvsi�e fill soils, verifiw�ion by o�hers. b. Foundation Soils ( Allowable Bearing = 2500 psf min) b.a. Bearing on Hard NaNral Undisturbed Clayey or Sandy Soils b.b. Friction Mgle between Base of Wall and Soil-19 deg Foundation Soils ( Allowable Bearing = 4000 psf min) Bearing on Bedrock c.b. Friction Mgle between Base of Wall and Soil-23 deg c.c. Bedrock Passive Pressure at �oe =400 psf d. Drainage Ma�erial d.a. Free draining granular backfill, dean, nonplastic, relatively wel4graded. 2.2. Dimension Stone Average Densiry of masonry wall varies hom 135pcf �0 145pc(. b. S�one size varies from 4" to 18". Face stone shall be coordinated between conVacmr and ownerldeveloper. d. Recycled concre�e 4" �0 18" may be used in place of dimension stone, wn�rac�ore op�ion. 2.5. Rebar/Welded Wire Fabric (If Required) All steel reinforcemeM shall be new bille� s�eel conforming �o ASTM A-615, Grade 60 wi�h ty=60ksi. b. All reinforcement shall not have deleterious material on it. c. NI welded wire fabric shall have minimum ty=65ksi and be ho� dip galvanized. 2.4. Drainage Materials Weep pipes shall be PVG or corrugated HDPE pipe. b. Drainage zone shall be separated from retained bac�ll by miraf 140N flter fabric or approved equal. 2.5 Portland Cement Mortar for Retaining Wall Construction. The pohland cemeM mortar used for construction of the masonry stone re�aining walls shall be provided wi�h �he following proportions per cubic yard of concrete. The ponland cement mortar supplier shall provide "batch tickets" dearly indicating that the appropriate oun� of ma�erials are provided in each truck load. The batch �ickets shall dearly indicate the amoun� batched, �he da�e, the project name and shall be provided to Falkofske Engineering, Inc. for review, documenta�ion, and file. Con�erRs Amoun� per cubic yard Specifc Graviry Volume ft^3 Type 1 Portland cement 451 Ibs 3.15 229 TypeFFlyAsh 113 Ibs 2.93 0.62 FineAggregate(sand): 274616s 259 16.99 Potable Wa�er 367 Ibs 44 Gallons 5.88 Sika Air (or equivalent) (AS REQ'D) oz 4.5% 122 z7.o Total Note: �he portland cement mohar supplier material weigh�s may vary sligh�ty based on �he specifc gravky of �he ma�erials used. Concrete retarders may be used atthe discretion ofthe masonry wall conhactor. A greater amount of retarder is typically used during ho� periods and a less amount of re�arder isrypically used during cool wea�her. Please note that the above proportions will provide a portland cement mortar with a compressive sirength of about fc =2500 psi. Falkofske Engineering, Inc. does not require any wncrete tes�ing provided the above propoNions are verified by way of �he "ba�ch tickets". 3. Construction 3.1 Preparation Work a. Priorto grading or excavation of the si�e, confrm the lowtion of �he retaining walls and all underground feaNres, including Nili�y bca�ion wi�hin the area of cons�ruc�ion. Ensure unding shucNres are protected hom eRecis of wall excavation, and consvuction. b. Coo�d�inate �installat�ion oi underground Nili�ies and other improvements wi�h wall ins�alla�ion. STRUCTURAL ENGINEERING CONSULTANTS 3.2 Ezcavation a. If a mortared foo�ing is over-excava�ed, then �he dimension stone shall be placed mortared. If a dry stone footing is over excavated, then ihe dimereion stone does not need to be monared. b. Fill over-excavated area in hont of the wall footing wRh compacted on site soils before the wall onstruc�ion exceeds 4fee� in heigM. c. In areas where the walls are installed in a cut, the required excava�ion shall e�end horizoMally to ihe e#ent of ihe width of ihe retaining wall. The wall may be built m ihe cuL If ihe wall is over cut, ihen soil shall either be compacted or the drainage zone may be widened. 3.3 Wall Construction a. The wall shall be wnstructed �o the dimensions as shown on these plans. FrorR leads, back leads,and s�ring lines shall be set for each walL Care shall be �aken �o install �he mohar zones ihe correct ihickness, and to place drainage behind ihe wall as required. b. Control joinis shall be installed at a maximum of 16'-0" o.c. per ihese plans. c. Weep pipes shall be placed a� 8'-0" o.c. max. d. Face rock �ype shall be coordinated benveen �he archi�ect, owner, and re�aining wall contractor. 3.4 Retained Backfill Placement a. Retained bac�ll shall be placed per the recommendations of the geotechnical engineer, but should no� be less �han 93% S�andard Proc�or Maximum Dry Densiry (ASTM D698). b. Fill should be placed in maximum 8" thick compacted IiRs. c. Large compaction equipment (equipment heavier than 7,50016) shall remain a minimum of 1 Sx �he heigM of �he wall away hom the back of �he wall for a period of 2 weeks from �he �ime of onstruc�ion. d. After a period of 2 weeks from ihe time of consVuction large compaction equipment may be used behind �he wall but shall s�ay a minimum of 5'-0" avrey from �he back of the wall. e. Soil placed wi�h in 5'-0" of �he back of �he wall shall be placed using handheld compac�ion equipment. f. If ihe wall is in a cut situation the wall may be built up m the cut. If the wall is overcut the drainage may be widened to �he cN or compacted fll may be placed belween �he drainage zone and ihe cut. 3.6 Retaining Wall Pertormance, Maintenance, and Other Comments a. CorRrol joinis are provided in the retaining wall m allow Por minor movements due m settlement and shrink swell ofthe soils. Some cracking may occur in the face of �he retaining wall. This raoking, If minor Qessthan 3I8"), may be wsmeHcalty repalred as daslrad. b. The retaining walls are designed m allow surtace water m flow over ihe tops of ihe retaining walls. Care should be �aken during and after construc�ion �o not allow water �o pond behind the retaining walls, as �his can have a nega�ive impac� on the stabili�y ofthe re�aining walls. c. If downspouts are located nearthe back of ihe retaining wall they should eRher be plumbed �hrough �he retaining wall to drain below �he wall or wllec�ed and �ied in�o �he storm sewer system. Pertora�ed subsurface pipes shall not be used behind the retaining walls. d. Positive drainage over ihe top of ihe walls shall be maintained ihroughout the life of the sVucture. If swales are placed behind the wall they shall remain clean and free draining. If water isfound to be ponding in the swale it shall be fxed �o allow water �o heety drain as soon as possible. e. Any broken sprinlders behind ihe retaining wall shall be Nrned off and repaired as soon as possible. 3.7 Cold Weather Construction of Retaining Walls Cons�ruc�ion Requiremenh for�emperotures be�ween 40°F antl 12°F: a. Water and aggregates used in mohar shall not be hea�ed above 140°F. b. Mortar sand or mixing water shall be heated m produce monar temperaNres behveen 40°F and 120°F at ihe time of mixing. Cons�ruc�ion Requirements for�emperotures be�ween 32°F antl 25"F: a. The guidelines above for construction requiremeMsfor �emperetures be�ween 40°F and 32°F and ihe following shall be met. b. The mor�ar �emperoture shall be main�ained above heezing un�il used in masonry stone retaining wall. c. Usible ice and snow shall be removed hom �he �op surtace of existing foundations and masonry to do' onstruction. These surtaces shall be heated to above freezing, using methodsthat �me�es�u i� aamaae. d. Newly consvucted masonry shall be completely covered with weather-resistive membrane for 48 hours afler being completed. Consiructlon Requlrements fortemperatures between 25°F and 20'F: a. The guidelines above for conshuction requiremenisfor temperaNres between 40°F and 32°F, ihe onstruction guidelinesfor �emperatures be�ween 32°F and 25°F, and �he following shall be me�. b. Masonry (raw stone) surtaces under wnstruction shall be hea�ed �0 40°F. c. Wnd breaks or endosures shall be provided when the wind velocRy exceeds 15 miles per hour. d. Newly consVucted masonry shall be completely covered with weatherresistive insulating blankets, or equal protection, for 46 hours after being completed. The above procedures comesfrom sec�ions 2104.3.2.1, 2104.3.2.2, 2104.3.2.3, 2104.3.3.3, and 2104.3.3.4 of �he In�emational Building Gode, and is in compliance wi�h Masonry S�andards JoiM CommiVee recommendations for cold weather consVuction of masonry strucNres. 4. Construction Observations 4.1 Construction Observations by Falkofske Engineering, Inc. a. Falkofske Engineering, Inc. will pertorm construction observation, but only as a means of verification of the contractors qualtty con[rol performance. b. Falkofske Engineering,lnc. will actasthe Speciallnspectorfor[his project. Contrac[or shall contact Falkofske Engineering to set up inspections, at least 1 day before onstruction starts. c. All required materials testing shall be pertormed by an approved materials testing laboratory. d. Falkofske Engineering, inc. is not responsible for means, methods, and material furnished by the retaining wall contractor. 4.2 Construction Observations by Others a. Construction observations as required by the city shall be coordinated by the contractor. MASONARY RETAINING WALLS - NOTES Job: 764.21 SHEET WINKLEMANN AND ASSOCIATES WESTWORTH COMMERCE CENTER Date: 01-23-25 6750 HILLCREST PLAZA DR. #215 NWC ALEMEDA STREET AND CHAPIN ROAD DALLAS, TEXAS 75230 FORT WORTH, TEXAS By: SC RW1-1 Scale: NTS � FALKOFSKE ENGINEERING, INC. POSi BY OTHER PVC SLEEVE FOR POST � AS REQ'D BY OTHER NOTE: DURING INSTALLATION OF — �— HANDRAIL POST IF SLEEVE LOCATION DOES NOT MATCH POST LOCATION IT IS PERMISSIBLE TO CORE DRILL THE 1'-8" DEPTH. � WALL SECTION W/HANDRAIL POST RW1-2 CONTRACTOR OPTION "r� e'-o" Mnx. PROVIDE 3" DIA. WEEP HOLE ����pq8 aWNER OR BUILDER $ o g pgB ' S�o$B°RBe8 a�8 � �� °s _ � �� � � PROVIDE CONTROL JOINTS � i6'-0" O.C. MAX. 2 TYPICAL PLAN VIEW AT BASE RW1-2 ". STRUCTURAL ENGINEERING CONSULTANTS 4. ,.,,., X,P7pA�NN51 MATERTAL M RTAF � � A RW1 N.T.S 3 TYPI A P N I W AT RN R RW 1-2 N.Ts. BATTER CAP BACK OF CAP FRONT OF CAP FACE OF L RETAINING WALL WALL HEIGHT TOE OF WALL IBEDMENT —I I I—I I I DEP_TH ���—�� H E�� �_ DEPTH FOUNDATION SOILS BASE WIDTH I I I—I I li �� / SHOULDER OF YIALL ���—� � �—� � �— � I�I—I BACK�F WALL —I I I I R AINED BACKFILL ��I�j� / / �� FAILURE WEDGE 55' HEEL LEGEND MASONARY RETAINING WALLS - NOTES Job: 764.21 SHEET WINKLEMANN AND ASSOCIATES WESTWORTH COMMERCE CENTER Date: 01-23-25 6750 HILLCREST PLAZA DR. #215 NWC ALEMEDA STREET AND CHAPIN ROAD DALLAS, TEXAS 75230 FORT WORTH, TEXAS By: SC RW 1-2 Scale: NTS � FALKOFSKE ENGINEERING, INC. HANDRAIL IF REO'D BY OTHERS RE: 1/RW1 AL50. TIGHttY FITTED STONE FULLY MORTARED REQUIRED POINT ALL FACE STONE JOINTS FACE STONE PER OWNER �6 1 3' DIA. WEEP HOLE O B'-0" O.C. 6' MIN. ABOVE GRADE FINISHED GRADE SLOPE 1V:8H MAX. REFER TO CIVIL FOR FINAL GRADING. —III—III IIIIIIIIIII I—I I I—I I I—I I I—I I I—I I-IIII III—III—IIII � _' � 1=1�I II I I I-1 STRUCTURAL ENGINEERING CONSULTANTS A T � REp D SIOPE �. ����� 4" TOP SOIL & 1'-8" CLAY CAP AND COMPACTED ON SITE SOIL. BACK FACE MAY BE IRREGULAR FILTER FABRIC AROUND DRAINAGE ZONE, MIRAFI 140N OR APPROVED EQUAL. COMPACTED, OR EXISTING ON SITE SOIL. CONTINUOUS GRAVEL OR CLE4N FREE DRAINING ROCK, SEE RW1 GENERAL NOTES. REFER TO A/RW6 FOR DRAINAGE ZONE ON WALLS 4'-0" OR LESS IN HEIGHT. FILTER FABRIC OVER END OF WEEP PIPE COMPACTED SOIL BELOW WEEP PIPE. ��� I II- �z" T� Z<� FILTER FABRIC AROUND I-1I1=1I1=1I I I I- D2nINAGE POCKEi. B � �IIIII�II11=111 II � �� �� � 3" �IA. WEEP HOLE � 8'-0" O.C. GRAVEL OR CLEAN ROCK CHIP POCKEf, 9" DEEP. A DRAINAGE POCKET RW6 WALLS 4'-0' ❑R LESS WSONRY lALL SCXdDULd ssoo sa - eweac uv�cm Mdxn x�runei uxnisroneao sou.s OR COIPI4T8D dND TJ3ldD 801G4 S88 QfM8R1l N0189 3fldMry �RyI11 HEICHf W9¢ roE OFFlX (TOFJ OEPIM (XFEL) �nElf ypR�OqEp 1HICMlF55 R�11L�GE Z� 6F�AHfr H B B1 C C1 A ZEE T G �A�m 1'-0' 1'-2' D'-2� 1'-0' 0'-3' 0'-2' 1'-0' SEE A/RWB 2'-0' 1'-4' 0'-4' 1'-0� 0'-3� 0'-�' 1'-0' SEE A/RWB 3'-0' 1'-9' D'-8' 7'-0� 0'-4' 0'-8' uoq�inFn 1'-3' SEE A/RW6 <�-0' 2'-1' D''7' 7''Y 0'-5' 0'-e' uox�inm 1'-8' SEE A/RW6 5'-0� 3'-D' D'-8' 1'-8' 0'-7' 0'-10� uox�inm 2'-4' 1�-U� 2500 pef 8._�. 3�_6. p�_9. Z._p. ��_8. �._0. � Z�_9. ��_�. �._Q. ��_�. ��_�0. 2._6. ��_9. �._Z. 3�_3. ��_�. 8._Q. �._8. �._p. 3._p. �._��. �._4. 3._8. �._�. 9•_U• S•_S• 1•_3• 3•_3• 1•_U• 1•_6• �r 1•_Y• 1•_U• 70'-0' 6'-2' 1'-7' 3'-9' 1'-2' 7'-8' a'-7' 1'-0' MALL D6SJCX CRITdR1A BFMING SLOPE TOP SLOPE BOT /CINE PR54.£ fAC1KK1 SIDPE Of y� W P P� PRF44UZ PRFSSURE NlOLE fl 9E fl�CK OF WNL q 2500PSF 14.04 Oeg 7.13 Eeg 28 deg 28 Aeg 79 Eeg 99.46 deg 0 pef USE THIS SCHEWLE FOR 1/RWB �1� TYPICAL WALL SECTION RW6 BEARING IN CLAY S�ILS "T.s MAX SLOPE ABOVE WALL 1V�4H MAX SLOPE BELOW WALL 1V�8H MASONARY RETAINING WALLS Job: 764.21 SHEET WINKLEMANN AND ASSOCIATES WESTWORTH COMMERCE CENTER Date: 01-23-25 6750 HILLCREST PLAZA DR. #215 NWC ALEMEDA STREET AND CHAPIN ROAD DALLAS, TEXAS 75230 FORT WORTH, TEXAS By: SC RW6-1 Scale: NTS � FALKOFSKE ENGINEERING, INC. HANDRAIL IF REQ'D BY OTHERS RE: 1/RW1 AL50. TIGHTLY FITfED STONE FULLY MORTARED REQUIRED POINT ALL FACE STONE JOINTS FACE STONE PER OWNER �6 1 3" DIA. WEEP HOLE � 8'-0" O.C. 6" MIN. ABOVE GRADE FINISHED GRADE SLOPE iV:BH MAX. REFER TO CIVIL FOR FINAL GRADING. � STRUCTURAL ENGINEERING CONSULTANTS 4" TOP SOIL & 1•_8• CLAY CAP AND COMPACTED ON SITE SOIL. BACK FACE MAY BE IRREGUL4R FILTER FABRIC AROUND DRAINAGE ZONE, MIRAFI 140N OR APPROVED EQUAL. COMPACTED, OR EXISiING ON SITE SOIL. CONTINUOl1S GRAVEL OR CLEAN FREE oRniNiNc ROCK, SEE RW1 GENERAL NOTES. REFER TO A/RW6 FOR DRAINAGE ZONE ON WALLS 4'-0" OR LE55 IN HEIGHT. FILTER FABRIC OVER END OF WEEP PIPE COMPACTED SOIL BELOW WEEP PIPE. ��2 TQ Z4� FILTER FABRIC AROUND � DRAINAGE POCKEf. II III�II11=111 II � � �� � 3" DIA. WEEP HOLE � 8'-0" O.C. GRAVEL OR CLEAN ROCK CHIP POCKET, 9" DEEP. A DRAINAGE POCKET RW6 WALLS 4'-0" ❑R LESS LASONRY ►ALL 3CXBDVL6 �000 Yf - H(IRP'0 fJPICITY iB��N� ON BSDROCS 3I'S OSNdRY,lRHi9 8H68f RII) B�4 tt1E B 9E B�SE B�TIE1f T11CIQ£55 R4W[� Z � x[iart wuTM xvm R�q oFmx (xFEU or rwi nucxxcss CRVACIry H B B1 C C1 A E T G 1'-0' 1'-2' D'-2� 0'-8' 0'-3' 0'-2' 1'-0' SEE A/RWB 2'-0' 1'-2' 0'-Y 0'-8' 0'-3� 0'-�' 1'-0' SEE A/RWB 3'-0' 1'-8' D'-3' 0'-9' 0'-4' 0'-8' uoq�inFn 1'-3' SEE A/RW6 4'-0' 1'-10' 0'-4' 0'-9' 0'-4' 0'-e' uox�inm 1'-8' SEE A/RW6 5'-0� 2'-9' 0'-5' 1'-0' 0'-8' 0'-10� uox�inm 2'-4' 1�-U� dp00 pef 8._�. 3�_j. p�_6. �._�. ��_�. �._0. � Z�_9. ��_�. 7'-0� 3'-70' 0'-7' 1'-0' 0'-9' 1'-2' 3'-3' 7'-0' 8._Q. �._4. �._8. �._3. �._��. �._4. 3._8. �._�. 9'-0' 1'-11' 0'-9' 1'-3' 0'-11' 1'-6' � 1'-2' 1'-0' td_0• 9•_b• U•_tU. �._8. �._�. �._8. �._�. �._�. MALL D6SJCX CRITdR1A BFMING PE lOP PE BOT /CINE PR54.£ fAC1KK1 SIDPE Of y� � „ � P. PRF44UZ PRFSSURE NlOLE fl 9E fl�CK OF WNL q /OOOPSF 14.04 deg 7.13 Eeg 28 deg 400 pef 23 Eeg 99.46 deg 0 pef USE THIS SCHEWLE FOR 2/RWB �2� TYPICAL WALL SECTION RW6 BEARING IN BEDROCK "T.s MAX SLOPE ABOVE WALL 1V�4H MAX SLOPE BELOW WALL 1V�8H MASONARY RETAINING WALLS Job: 764.21 SHEET WINKLEMANN AND ASSOCIATES WESTWORTH COMMERCE CENTER Date: 01-23-25 6750 HILLCREST PLAZA DR. #215 NWC ALEMEDA STREET AND CHAPIN ROAD DALLAS, TEXAS 75230 FORT WORTH, TEXAS By: SC RW6-2 Scale: NTS 51.OPE M�E�D tV'4� EXHIBIT C (1 OF 2) Exhibit "C" CITY OF FORT WORTH STORMWATER FACILITY OPERATION AND MAINTENANCE PLAN The only responsibility the City of Fort Worth has in the operation and maintenance of this Facility is inspection. General Maintenance Procedures The structural and functional integrity of the Facility shall be maintained at all times by removing and preventing drainage interference, obstructions, blockages, or other adverse effects into, through, or out of the system. Periodic silt removal shall occur when standing water conditions occur or the pond's storage volume is reduced by more than 10%. Silt shall be removed and the pond/basin returned to original lines and grades shown on the approved engineering plans. In addition, corrective measures are required any time a basin does not drain completely within 72 hours of cessation of inflow. NO STANDING WATER IS ALLOWED in basins designed for dry detention purposes. Accumulated litter, sediment, and debris shall be removed every 6 months or as necessary to maintain proper operation of the basin. Disposal shall be in accordance with federal, state and local regulations. Detention facilities shall be mowed monthly between the months of April and October or anytime vegetation exceeds 12-inches in height. To prevent debris from entering and clogging the downstream storm sewer system a wire mesh screen or similar screening device shall be installed over the outlet until final acceptance. 4. PREVENTIVE MAINTENANCE/INSPECTION • Visual inspections of all components will be conducted every 6 months. • A log shall be kept of maintenance actions, and inspections. The log should document the condition of the detention system's primary components, mowing, and silt, litter and debris removal dates. Document aeration of the basin bottoms and replanting to prevent the sealing of the basin bottom. • Written maintenance and repair records shall be maintained by the party or parties signing the attached Agreement and shall be provided to the City upon request. STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 12/29/2014 EXHIBIT C (2 OF 2) Exhibit "C" CITY OF FORT WORTH RETAINING WALL MAINTENANCE PLAN The only responsibility the City of Fort Worth has in the operation and maintenance of this Facility is inspection. General Maintenance Procedures a. Control joints are provided in the retaining wall to allow for minor movements due to settlement and shrink swell of the soils. Some cracking may occur in the face of the retaining wall. This cracking, if minor (less than 3/8"), may be cosmetically repaired as desired. b. The retaining walls are designed to allow surface water to flow over the tops of the retaining walls. Care should be taken during and after construction to not allow water to pond behind the retaining walls, as this can have a negative impact on the stability of the retaining walls. c. If downspouts are located near the back of the retaining wall they should either be plumbed through the retaining wall to drain below the wall or collected and tied into the storm sewer system. Perforated subsurface pipes shall not be used behind the retaining walls. d. Positive drainage over the top of the walls shall be maintained throughout the life of the structure. If swales are placed behind the wall they shall remain clean and free draining. If water is found to be ponding in the swale it shall be fixed to allow water to freely drain as soon as possible. e. Any broken sprinklers behind the retaining wall shall be turned off and repaired as soon as possible. STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 12/29/2014 INSPECTION CHECKLIST FOR SIMPLE DETENTION BASIN Form CFW-6CFW- SEPTEMBER 2015 Appendix A A-17 Facility Name: ____________________________________________________ Facility Agreement Number: ______________ Date: _____________________ Type of Inspection: Annual ____, Quarterly ____, Monthly ____, Routine ____, or Storm Event ____, (# days since event ______)Basin Conditions: 1. Is there standing water or wet spots? Yes___ No ___ Comments _____________________________ 2. Does sides or bottom show signs of erosion, settling, cracking, etc? Yes___ No ___ Comments _____________________________ 3. Does dam or emergency spillway show signs of erosion, settling, cracking, or other problems? Yes___ No ___ Comments _____________________________ 4. Is there evidence of animal burrowing in dam? Yes___ No ___ Comments _____________________________ 5. Is there evidence of changes in shape or volume of basin? Yes___ No ___ Comments _____________________________ 6. Do vegetated areas need mowing? Yes___ No ___ Comments _____________________________ 7. Are there trees or woody growth in dam? Yes___ No ___ Comments _____________________________ 8. Are there areas that need to be re-vegetated? Yes___ No ___ Comments _____________________________ 9. Is there any accumulation of silt, trash, debris or litter in the basin? Yes___ No ___ Comments _____________________________ 10. Are there any other basin maintenance activities needed? Yes___ No ___ Comments _____________________________ Structural Components: 1. Are pipes, channels, trash racks, etc. free of obstructions? Yes___ No ___ Comments _____________________________ 2. Are pipes, spillway or trash racks in need of repair? Yes___ No ___ Comments _____________________________ 3. Is the low flow or trickle channel in need of repair? Yes___ No ___ Comments _____________________________ 4. Is the outfall channel in need of repair? Yes___ No ___ Comments _____________________________ 5. Are there any other structural maintenance activities needed? Yes___ No ___ Comments _____________________________ Plan for correcting deficiencies: ____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________Signature: ________________________________ Owner’s Representative Date: _______________________________ Basin/Pond Number:_______Inspected By:__________________________________Pond 1SWFMA-22-00679700 Chapin Rd. INSPECTION CHECKLIST FOR SIMPLE DETENTION BASIN Form CFW-6CFW- SEPTEMBER 2015 Appendix A A-17 Facility Name: ____________________________________________________ Facility Agreement Number: ______________ Basin/Pond Number: _______ Inspected By: __________________________________ Date: _____________________ Type of Inspection: Annual ____, Quarterly ____, Monthly ____, Routine ____, or Storm Event ____, (# days since event ______)Basin Conditions: 1. Is there standing water or wet spots? Yes___ No ___ Comments _____________________________ 2. Does sides or bottom show signs of erosion, settling, cracking, etc? Yes___ No ___ Comments _____________________________ 3. Does dam or emergency spillway show signs of erosion, settling, cracking, or other problems? Yes___ No ___ Comments _____________________________ 4. Is there evidence of animal burrowing in dam? Yes___ No ___ Comments _____________________________ 5. Is there evidence of changes in shape or volume of basin? Yes___ No ___ Comments _____________________________ 6. Do vegetated areas need mowing? Yes___ No ___ Comments _____________________________ 7. Are there trees or woody growth in dam? Yes___ No ___ Comments _____________________________ 8. Are there areas that need to be re-vegetated? Yes___ No ___ Comments _____________________________ 9. Is there any accumulation of silt, trash, debris or litter in the basin? Yes___ No ___ Comments _____________________________ 10. Are there any other basin maintenance activities needed? Yes___ No ___ Comments _____________________________ Structural Components: 1. Are pipes, channels, trash racks, etc. free of obstructions? Yes___ No ___ Comments _____________________________ 2. Are pipes, spillway or trash racks in need of repair? Yes___ No ___ Comments _____________________________ 3. Is the low flow or trickle channel in need of repair? Yes___ No ___ Comments _____________________________ 4. Is the outfall channel in need of repair? Yes___ No ___ Comments _____________________________ 5. Are there any other structural maintenance activities needed? Yes___ No ___ Comments _____________________________ Plan for correcting deficiencies: ____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________Signature: ________________________________ Owner’s Representative Date: _______________________________ Pond 2SWFMA-22-00679700 Chapin Rd.