Loading...
HomeMy WebLinkAboutContract 63496Date Received: 6/20/2025 Permit No.: SWFMA-25-0044 Time Received: 1:56 p.m. City secretary No.: 63496 STORMWATER FACILITY MAINTENANCE AGREEMENT THIS AGREEMENT, made and entered into this 20th day of June , 2025, by and between Northwest Independent School District, a political subdivision of the State of Texas, acting by and through Dr. Mark Foust, its duly authorized Superintendent, hereinafter referred to as "Landowner", and the City of Fort Worth, hereinafter referred to as "City". WITNESSETH WHEREAS, the Landowner is the owner of certain real property described as a tract of land situated in the Hopkins Davidson Survey, Abstract No. 437, City of Fort Worth, Tarrant County, Texas according to the deed recorded in Document No. D216265006, Official Public Records, Tarrant County, Texas, hereinafter called the "Property"; WHEREAS, the Landowner is proceeding to build on and develop the Property according to the Site Plan/Subdivision Plan known as Northwest ISD HS #4 New High School, hereinafter called the "Plan", which is expressly made a part hereof, as approved or to be approved by the City and the Landowner provides for management of storm water within the confines of the Property; and; WHEREAS, the City and the Landowner, and their successors and assigns, agree that the health, safety and welfare of the residents of the City of Fort Worth, Texas require that on -site Stormwater Management Facilities be constructed and maintained on a portion of the Property; and OFFICIAL RECORD CITY SECRETARY FT. WORTH, TX STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 03/01/2022 BN WHEREAS, the City requires that on -site Stormwater Management Facilities ("Facility") as shown on the Plan be constructed and adequately maintained by the Landowner, its successors and assigns, the location and dimensions of which is shown and more particularly described by metes and bounds in the attached Exhibit "A" ("Facility Property"); and NOW, THEREFORE, in consideration of the foregoing premises, the mutual covenants contained herein, and the following terms and conditions, the parties hereto agree as follows: 1. The Landowner, its successors and assigns, shall adequately construct and maintain the on -site Stormwater Management Facility ("Facility") at no expense to the City of Fort Worth in accordance with the design specifications for the Facility, attached as Exhibit "B", and the current standards then in force and effect in the City of Fort Worth and with the Operations and Maintenance Plan attached to this Agreement as Exhibit "C". The Stormwater Facility includes all pipes, channels or other conveyances built to convey Stormwater to the facility, as well as all structures, improvements, and vegetation provided to control the quantity and quality of the Stormwater. Adequate maintenance is herein defined as good working condition so that these facilities are performing their design functions. The Stormwater Structural Control Maintenance Checklists, attached to this Agreement as Exhibit "D", are to be used to establish what good working condition is acceptable to the City. 2. The Landowner, its successors and assigns, shall inspect the Facility and submit an inspection report to the City annually. The purpose of the inspection is to ensure the safe and proper functioning of the Facility. The inspection shall cover the entire Facility, berms, outlet structure, pond areas, access roads, etc. Components of the Facility, which need maintenance or replacement to perform their design function, shall be noted in the inspection report along with the corrective actions to be taken. STORMWATER FACILITY MAINTENANCE AGREEMENT 2 Rev. 03/01/2022 BN 3. The Landowner, its successors and assigns, hereby grant permission to the City, its authorized agents and employees, to enter upon the Property and to inspect the Facility Property whenever the City deems necessary. The purpose of inspection is to follow-up on reported deficiencies and/or to respond to citizen complaints. The City shall provide the Landowner, its successors and assigns, copies of the inspection findings and a directive to commence with the repairs if necessary. 4. In the event the Landowner, its successors and assigns, fail to maintain the Facility in good working condition as specified herein, the City, its authorized agents and employees, may enter upon the Facility Property and take whatever steps necessary to correct deficiencies identified in the inspection report and to charge the costs of such repairs to the Landowner, its successors and assigns. It is expressly understood and agreed that the City is under no obligation to routinely maintain or repair said Facility, and in no event shall this Agreement be construed to impose any such obligation on the City, such obligation is Landowner's. 5. The Landowner, its successors and assigns, will perform the work necessary to keep the Facility in good working order as appropriate. In the event the City pursuant to this Agreement, performs work of any nature, or expends any funds in performance of said work for labor, use of equipment, supplies, materials, and the like, the Landowner, its successors and assigns, shall reimburse the City upon demand, within thirty (30) days of receipt thereof for all actual costs incurred by the City hereunder. 6. This Agreement imposes no liability of any kind whatsoever on the City. 7. Landowner covenants and agrees that no habitable building shall be erected within the boundaries of the Property in which the Facility is located as outlined on Exhibit "A" but this paragraph shall not preclude construction of other improvements within the boundaries of the Property in which the Facility is located, which do not impede drainage. Landowner covenants and agrees that no habitable building shall be erected on the above property abutting such boundaries of the Property in which is Facility is located, which shall have a STORMWATER FACILITY MAINTENANCE AGREEMENT 3 Rev. 03/01/2022 BN finished floor at an elevation less than two feet above the maximum depth of water in the detention pond which would occur during a 100-year frequency flood. 8. This Agreement shall be recorded among the land records of Tarrant County, Texas, shall constitute a covenant running with the land, and shall be binding on the Landowner, its administrators, executors, assigns, heirs and any other successors in interests, including any property owner's association. [SIGNATURES ON THE FOLLOWING PAGE] STORMWATER FACILITY MAINTENANCE AGREEMENT 4 Rev. 03/01/2022 BN Executed this 19th day of Jun e CITY OF FORT WORTH Jesica McEachern Assistant City Manager City of Fort Worth Date: 06/19/2025 Approved as to Form and Legality: M. Kevin A�ole�t 11 oh bel�aGf o tt M. Kcv, An d, ,,II-b,haff f rA At Murray (J un 16, 207509.T9 C.J Matthew Murray Senior City Assistant Attorney City Attorney's Office Date: 06/16/2025 4 pO! pOHT 4;b ATTEST: '° °_°° PdQn oEXASoo Jannette S. Goodall City Secretary Date: 06/20/2025 2025. LANDOWNER Northwest Independent School District a Texas nonprofit corporation By: Dr. Mark oust Its: Superintendent Date: Contract Compliance Manager: I acknowledge that I am the person responsible for the monitoring and administration of this contract, including ensuring all performance and reporting re uir ments. 4�� Kandice Merrick Planning Manager Date: 06/16/2025 OFFICIAL RECORD CITY SECRETARY FT. WORTH, TX STORMWATER FACILITY MAINTENANCE AGREEMENT 5 Rev. 03/01/2022 BN STATE OF TEXAS § COUNTY OF TARRANT § 2025 This instrument was acknowledged before me on June 19th, by Jesica McEachern, Assistant City Manager of the City of Fort Worth, on behalf of the City of Fort Worth. otpR�PLB KATHLEEN BRADFORD f Notary Public t STATE OF TEXAS Notary I.D. 12197197 My Comm. Exp. Apr. 12, 2027 - - - - - - - - - - - - - - LANDOWNER STATE OF� COUNTY OF ]P,047b,,, Notary Public, State of Texas M BEFORE ME, the undersigned authority, a Notary Public in and for the State of -T'--4'ko , on this day personally appeared (name), S"lr11(df vtd t4 6 L S d/vA-j (title), known to me to be the person whose name is subscribed to the foregoing instrument, and acknowledged to me that he/she executed the same for the purposes and consideration therein expressed, as the act and deed of I % (entity), a J xt( � /' {p (entity type) and in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE this day of a JENNIFER ROBERTS Notary ID #10669430 My Commission Expires August 8, 2025 *artybub'i State of STORMWATER FACILITY MAINTENANCE AGREEMENT 6 Rev. 03/01/2022 BN EXHIBIT "A" LEGAL DESCRIPTION STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 03/01/2022 BN EXHIBIT "A" "STORM WATER DETENTION FACILITY & DRAINAGE" BEING 7.132 acres of land, situated in the Hopkins Davidson Survey, Abstract No. 437, City of Fort Worth, Tarrant County, Texas, and being a portion of the remainder of that certain tract of land conveyed in deed to Northwest Independent School District (Northwest I.S.D.), according to the deed filed in Instrument #D216265006, Deed Records of Tarrant County, Texas (D.R.T.C.T.), and being more particularly described by metes and bounds as follows: COMMENCING at a 1/2 inch iron rod found at the northwest corner of said Northwest I.S.D. tract (Inst. #D216265006), also being the northeast corner of that certain tract of land conveyed in deed to Northwest Independent School District (Northwest I.S.D.), according to the deed filed in Instrument #D224180802, D.R.T.C.T., and being in the south line of Lot 2, Block 1, Alliance Gateway West Addition, an addition to the City of Fort Worth, as filed in Cabinet A, Slide 5817, Plat Records of Tarrant County, Texas (P.R.T.C.T.), from which a 1/2 inch iron rod with cap stamped "TNP", recovered at the southeast corner of said Northwest I.S.D. tract (Inst. #D224180802), also being the northeast corner of the remainder of a tract of land described in the deed to ADL Development, L.P., a Texas Limited Partnership, according to the deed filed in Instrument #D218054115, D.R.T.C.T., and being in the west line of said Northwest I.S.D. tract (Inst. #D216265006), bears S 00°12'58" E, a distance of 2223.70 feet; THENCE N 89046'37" E, along the north line of said Northwest I.S.D. tract (Inst. #D216265006), and along the south line of said Lot 2, also passing along the south line of a tract of land described in deed to Oncor Electric Delivery Company LLC, as filed in Instrument #D223091339, D.R.T.C.T., and the south line of the remainder of a tract of land described in deed to AIL Investment, L.P., as filed in Volume 9381, Page 66, D.R.T.C.T., a distance of 1596.98 feet to a 3/8 inch iron rod set with cap stamped "TNP INC ESMT" (hereinafter all 3/8 inch iron rods set are marked the same) for the POINT OF BEGINNING of the hereinafter described tract of land; THENCE N 89046'37" E, continuing along the north line of said Northwest I.S.D. tract (Inst. #D216265006), also passing along the south line of a tract of land described in deed to Oncor Electric Delivery Company LLC, as filed in Instrument #D223091338, D.R.T.C.T., a distance of 216.19 feet; THENCE leaving said line, passing over and across said Northwest I.S.D. tract (Inst. #D216265006), the following courses and distances; S 00°13'23" E, a distance of 41.21 feet; S 88°14'16" E, a distance of 252.20 feet; S 86°46'52" E, a distance of 148.17 feet; S 83032150" E, a distance of 41.32 feet; S 80°56'24"E, a distance of 105.75 feet to a 3/8 inch iron rod set; S 00°55'38" E, a distance of 51.95 feet; S 05°48'49" E, a distance of 150.21 feet; S 43'01'52" E, a distance of 23.83 feet; S 14°24'55" E, a distance of 245.99 feet to the beginning of a curve to the left whose radius is 116.84 feet, and whose long chord bears S 12°30'53" E, a distance of 91.89 feet; Along said curve in a southeasterly direction, through a central angle of 46°18'38", an are length of 94.44 feet to the end of said curve; S 35°48'34" E, a distance of 151.58 feet to a 3/8 inch iron rod set at the northeast corner of a 20' Drainage Easement, as filed in Instrument #D208114814, D.R.T.C.T.; Sheet 1 of 4 NWI 23360 S 53°43'38" W, along the northwesterly line of said 20' Drainage Easement, a distance of 20.00 feet to a 3/8 inch iron rod set at the northwest corner of said 20' Drainage Easement; N 39°43'33" W, a distance of 147.68 feet to the beginning of a curve to the left whose radius is 80.00 feet, and whose long chord bears N 63°20'02" W, a distance of 64.08 feet; Along said curve in a northwesterly direction, through a central angle of 47°12'57", an arc length of 65.93 feet to the beginning of a reverse curve to the right whose radius is 100.97 feet, and whose long chord bears N 65°00'49" W, a distance of 72.27 feet; Along said curve in a northwesterly direction, through a central angle of 41°56'27", an arc length of 73.91 feet to the beginning of a compound curve to the right whose radius is 80.00 feet, and whose long chord bears N 38*01'59" W, a distance of 16.75 feet; Along said curve in a northwesterly direction, through a central angle of 12'01' 13", an arc length of 16.78 feet to the end of said curve; N 32'01'23" W, a distance of 55.54 feet; N 20°45'32" W, a distance of 65.66 feet to the beginning of a curve to the right whose radius is 50.00 feet, and whose long chord bears N 10°49'30" W, a distance of 17.25 feet; Along said curve in a northwesterly direction, through a central angle of 19°52'04", an arc length of 17.34 feet to the beginning of a reverse curve to the left whose radius is 70.00 feet, and whose long chord bears N 45°21'32" W, a distance of 98.07 feet; Along said curve in a northwesterly direction, through a central angle of 88°56'07", an arc length of 108.66 feet to the end of said curve; N 89°49'35" W, a distance of 127.82 feet; S 42°48'36" W, a distance of 56.88 feet; N 86°25'57" W, a distance of 378.86 feet to a 3/8 inch iron rod set; N 00°13'23" W, a distance of 153.44 feet to the beginning of a curve to the left whose radius is 41.92 feet, and whose long chord bears N 45°13'23" W, a distance of 59.28 feet; Along said curve in a northwesterly direction, through a central angle of 90°00'00", an arc length of 65.84 feet to the end of said curve; S 89°46'37" W, a distance of 6.54 feet; N 00° 14'45" W, a distance of 201.46 feet to the POINT OF BEGINNING and containing 310,680 square feet or 7.132 acres of land. Oil Q• �` O I �, ••1HERON•W�•SIMS Ap .%.................. 10, 2025 . Theron W. SimsR.P.L. , Eq 5887 Texas Registration No. 5867 Surveyed on the ground April 30, 2025M 1. Bearings of lines shown hereon refer to Grid North of the Texas Coordinate System of 1983 (North Central Zone; NAD83 (2011) Epoch 2010) as derived locally from Western Data Systems Continuously Operating Reference Stations (CORS) via Real Time Kinematic (RTK) methods. An average Combination Factor of 1.00012 was used to scale grid coordinates and distances to surface. 2. Integral parts of this survey: a. Legal Description b. Sketch Sheet 2 of 4 NWI 23360 CURVE TABLE DELTA CHORD BEARING I CHORD I 46'18'38 S12'30'53"E 191.89' 47'12'57" N63'20'02"W 64.08' 41'56'27" I N65'00'49"W 172.27' 12-01'13" N38'01'59"W 116.75' 19'52'04" I N10'49'30"W 17.25' 88'56'07" I N45'21'32"W 198.07' 90'00'00" I N45'13'23"W 159.28' CURVE# LENGTH RADIUS C1 94.44' 116.84' C2 65.93' 80.00' C3 73.91' 100.97' C4 16.78' 80.00' C5 17.34' 50.00' C6 108.66' 70.00' C7 65.84' 41.92' teague nail & perkins 5237 N. Riverside Drive, Suite 100 Fort Worth, Texas 76137 817.336.5773 ph 817.332.7756 fx tnp / TBPELS Registration No. 100116-00 C:\Users\rterguson\oneDrive - Teague Noll & Perkins\Desktop\7132 Ac Storm Water Detention Focitlity - NW1 23360.dwg NOTES., 1) Bearings of lines shown hereon refer to Grid North of the Texas Coordinate System of 1983 (North Central Zone; NAD83 (2011) Epoch 2010) as derived locally from Western Data Systems Continuously Operating Reference Stations (CORS) via Real Time LINE TABLE I Kinematic (RTK) methods. An average Combination Factor of 1.00012 was used to scale grid coordinates and distances to surface. LINE # DIRECTION LENGTH 2) Integral parts of this survey: a. Legal Description L1 N89'46'37"E 121 6.19' b. Sketch L2 I SOO'13'23"E I 41.21' L3 I S88-14'16"E 1252,20' 1-4 I S86'46'52"E 1148.17' L5 I S83'32'50"E I 41.32' L6 I S80'56'24"E L7 1105.75' SOO'55'38"E 51.95' L8 I S05'48'49"E 1150.21' 19 S43'01'52"E I 23.83' L10 I S14'24'55"E 1245.99' L11 I S35'48'34"E 1151.58' L12 I S53'43'38"W I 20.00' L13 I N39'43'33"W 1147.68' L14 I N32'01'23"W I 55.54' L15 I N20'45'32"W I 65.66' L16 I N89'49'35"W 1127.82' L17 I S42'48'36"W I 56.88' L18 I N86'25'57"W 1378.86' EXHIBIT "B" L19 I N00'13'23"W 1153.44 I STORM WATER L20 S89'46'37"W 6.54' DETENTION FACILITY L21 I NOD'14'45"W 1201.46' I & DRAINAGE Situated in the Hopkins Davidson Survey, Abstract No. 437, City offort Worth, Tarrant County, Texas. JOB No. NWl 2JJ60 SHEET 4 OF 4� APPROVED WAIVERS FORT WORTH 4 Fart Worth o4� Stormwater Management REQUEST FOR WAIVER FROM CITY OF FORT WORTH — STORMWATER Submitted by: Amanda Mullen Phone: 817-420-7414 Date: 4/11/2025 Company: Teague Nall & Perkins Email: amullen@tnpinc.com Proposed Project Description Name: NISD HS #4 - Retention/Detention Pond Type: Retention/Detention Pond to serve NISD HIS #4; DS-24-0131; SWFMA-25-0014; CG-25-00012 Location: North Riverside Drive, South of 170 (include map) Existing Condition (show information on map or drawing) CFW Maintained Facilities: None Existing Right -of -Way for CFW facility: N/A Topography: See attached drawings Other Pertinent Data Related to waiver Request: Waiver requested to item 9 under section 3.8.4.5 to allow for slope paving of slopes up to 1:1. In areas of 1:1 grouted rock rip rap a detail is provided of the proposed design. Grouted rock rip rap will be laid on flat steps within the pond (refer to attached detail). For areas of slope pavement within the berm and spill way flatwork with have a 24" toe at top and bottom of the slope, weepholes and gravel pack are also provided (refer to attached detail). Waiver Request Specific criteria you want to vary: Item 9 under Section 3.8.4.5 to allow for slope paving of slopes up to 1:1. Explain why the criteria needs to be varied or is not applicable: Pond locations is on the north side of the site, there is an existing gas road, and easements that limit available space. coupled with limitations of impacts to existing wetlands and site configuration steeper slopes were necessary at certain areas. Explain how the basis for the criteria Will be Satisfied: The design of the grouted rock rip rap shows the rock will be places on on flat steps cut into the earth to provide stability. The slope paving is 6" flatwork, reinforced with #3 bars at 18" OC with a 24" toe at top and bottom of the slopes. Details are attached to the waiver request. List attachments supporting waiver request (preliminary design report excerpt, construction drawings, calculations, photographs, map, etc.: Justification of Decision: Details for waiver are consistent with approved grading plans -waiver granted based on physical constraints for the on -site design; no adverse impact anticipated based on approved design plans with varied criteria. Notes: Waiver Decision: Reviewer Signature: Accepted ❑✓ Denied ❑ Date: 4.28.25 Form CFW-7 CFW- July 2024 161 EXHIBIT "B" DESIGN PLAN AND SPECIFICATIONS STORMWATER FACILITY MAINTENANCE AGREEMENT Rev. 03/01/2022 BN I � \ SWFMA BOUNDARY 1 1/11 W \ S BOUNDARY ii !� �. , � � fill IKEYRM Sir" 1_Iow' scale City of Fort Worth, Texas tnp prol0f teague nail and perkins, inc hori. GLP23338 5237 N. Riverside Drive, Suite 100 1 .. =80' Improvements for sheet Fort Worth, Texas 76137 HIGH SCHOOL #4 817.336.5773 ph 817.336.2813fx PZI 1 -­Mpinc.co. date SWFMA EXHIBIT of TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 GRADING OVERALL 26 _------- — — — — — — - r — . asp sit 9rz LFL I EXIST. 10' RAMP SWFMA BOUNDARY I I / 24 TYPE C /HEADWALL _— I II I I� F/L=718.36 1 /w �% I � I i I I I I I I I l= w 12' ROCK \ < RIP —RAP \ ,� .410 oz� TOP GABION IZ WALL ELEV.• �734.50 ^ I/ X BOTTOM GABION WALL ELEV ,729.50 1ryti BOTTOM GABION��° WALL ELEV 1ryh I I I 729.50 GABION POND /j EDGE Ai teague nail and perkins, inc SFa�e oriz 5237 N. Riverside Drive, Suite 100 1 rr=40r Fort Worth, Texas 76137 v rt 817.336.5773 ph 817.336.2813fx N/A www.tnpinc.com date TBPELS: ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 City of Fort Worth, Texas tnp prol0f GLP23338 Improvements for sheet HIGH SCHOOL #4 2 SWFMA EXHIBIT of GRADING PLAN - SECTION A 26 Jq w / 24" TYPE V I/ \ HEADWALL _ / FA = 71&J6 cm 11 I\ Lu F/L = 716.34 1 12" ROCK o \ RIP -RAP Lu I I ii I Lu so 3 " -24 ROCK RIP -RAP TOM GABIION . ELEV 50 BOTTOM GABION�,°c WALL ELEV. 729.50 ^� l I TOP GABION I I WALL ELEV I 734.50 j �IIATC LIN teague nail and perkins, inc 5237 N. Riverside Drive, Suite 100 Fort Worth, Texas 76137 817.336.5773 ph 817.336.2813fx www.tnpinc.com TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 72 TYPE C HEADWALL 1 SWFMA BOUNDARY � n a ^I ^ LARGE BLOCK scale oriz 1 rr=40' N /rA date APR 2025 TW 749.00 BW 749.00 �Ia City of Fort Worth, Texas Improvements for HIGH SCHOOL #4 SWFMA EXHIBIT GRADING PLAN -SECTION B tnp prol0( GLP23338 sheet 3 of 26 , \\\\\\BOTTOM GABION -GABION POND WALL ELEV EDGE 729.50 TOP GABION Y7TALL WALL ELEV VRE 735.50 LARGE BLOCK RETAINING WALL A���� TOP GABION WALL ELEV 734.50 TW 749.06 N BW 737.OG N I I \ � I,I J II LARGE BLOCK RETAINING WALL SEE SHEET 24 -60" TYPE V HEADWALL I � � 1 TW 749.00 / BW 737.00 SEE SHEET 25 TW 752,25 )'MTMA BW- 739.00 BOUNDARY TW 752.25 BW 752.25 ---------------- scale League nail and perkins, inc t,oriz 5237 N. Riverside Drive, Suite 100 1 rr=40r Fort Worth, Texas 76137 v It 817.336.5773 ph 817.336.2813 FirN/A www.t,pinc.com date 4tn TBPELS- ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 f City of Fort Worth, Texas GLP23338 Improvements for sheet HIGH SCHOOL #4 4 SWFMA EXHIBIT of GRADING PLAN - SECTION C 26 I I I II I N I �I I I It I �I SWFMAI BOUNDARY \ I I JHU I ^I P ill ICI I� TOP GABON- WALL ELEV 735.50 N r. N GABION ^ Y I POND EDGE I I r, BOTTOM GABIOh \ WALL ELEV / 729.50 /� 1 ✓ I\ �k\\�,`\ I_ 11\ I` 1 \ �1 EMERGENCY SPILL WA Y SEE SHEET 14 /�� �IIIIII�IIII I I I I I I I teague nail and inc SFale perkins, oriz 5237 N. Riverside Drive, Suite 100 1 rr=40r Fort Worth, Texas 76137 v rt N(A 817.336.5773 ph 817.336.2813 fx date www.tnpin—om TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 01 010 h%0% 60k\'Nol 4 N8, 0 4me M FA �;717.50) N&\k -'� \ \ \ \\\ BOTTOM GABIOA -GABION POND WALL ELEV EDGE 729.50 7x7' OUTFALL--- STRUCTURE l TOP GABION FIRST WEIR WALL ELEV ELEVA LION.• / 735.50 F/L=732.50 J LARGE BLOCK RETAINING WALL SEE SHEET 25 , KEYPLAN SCALE 1 =4000' �a tnp City of Fort Worth, Texas Improvements for HIGH SCHOOL #4 SWFMA EXHIBIT GRADING PLAN - SECTION D tnp proldtf GLP23338 sheet 5 of 26 I �I rl QA-Oif � I `'i�� _ 1717 M/4 W n I IL .40e 1 Drainage Area Map Legend 17.919 I NM_ rTowARRoxs oRNNAce AREAS AGE AREA REAGE oasnNG MMAGE alines PRE -PROJECT DRAINAGE AREA MAP C HYDROLOGY DATA - PRE -PROJECT CONDITIONS Basin ID Area (ac) Area I CN I TC (min) Lag Time Ql (CFS) 05 (CFS) 0100 (CFS) (SgMi) (min) DA-01 58.23 0.0910 79 27.2 16 53.3 121.4 298.0 DA-02 17.99 0.0281 74 27.6 17 11.3 29.9 81.7 DA-03a 49.98 0.0781 79 25.9 16 45.7 104.2 255.8 DA-03b 14.23 0.0222 80 15.0 9 18.2 40.3 96.7 DA-04 26.51 0.0414 90 19.6 12 49.8 88.4 178.7 DA-05 26.62 0.0416 95 15.9 10 65.6 106.4 201.3 DESIGN POINT SUMMARY N07ES• 1. Please refer to Drainage Study DS-24-0131 for additional background information on the overall analysis. 2. Per City criteria, Pond routing was completed using the Unit Hydrograph - SCS Method. J. Increases in discharge due to proposed site development are anticipated to be mitigated using the detention pond. Increases will occur immediately downstream of the site, nris increase is proposed to minimize the impacts within the watershed as a whole. (Please refer to Drainage Study (DS-24-01Y) for additional information. 4. At least 1.00' of freeboard is provided in the detention pond for the 100-year storms events and 0.5' of freeboard for dogged conditions. Q1 (CFS) Q5 (CFS) 0100 (CFS) Basin ID EX PROP A EX PROP A EX PROP A DP-01 53.3 39.9 -13.4 121.4 80.2 -41.2 298.0 178.5 -119.5 DP-04 79.1 71.5 -7.6 191.8 179.3 -12.5 497.4 584.2 86.8 0 tnp prol6lr League nail and perkins, inc 5F°�e City of Fort Worth, Texas GLP23338 5237 N. Riverside Drive, Suite 100 1 "=500r Improvements for sheet Fort Worth, Texas 76137 vert HIGH SCHOOL #4 817.336.5773 ph 817.336.2813 fx N(A L __tnpinc.com date SWFMA EXHIBIT of of TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 PRE -PROJECT DRAINAGE AREA MAP 26 t 0 �" o a 0 0 Q 0 9 \� 0��o ; o a o , 0 0 6 d I � 0 d 2% 177G�L_ _75 oo � LN-0L1 0 0 0 0 0 0 0 0 0 0 0 �� o 0 0 0 0 0 00000000 000 doo ooC/� rI \ I POST -PROJECT DRAINAGE AREA MAP HYDROLOGIC DATA - POST -PROJECT CONDITIONS / min /bwwsw a7Y FU / W-1175 Drainage Area Map Legend 111111- flaw AMC -,DRAINAGE AREA aas MANAGE AREA ACREPROPOSED DRAINAGE DIMES Basin ID Area (as) ren CN TC (min) Lag Tiara 01 (CFS) 05 (CFS) 0100 (CFS) N07ES- I 1. Please refer to Drainage Study DS-24-0131 for additional DA-01 23.66 0.03697 84 13.11 8 39.9 80.2 178.5 background information on the overall analysis. DA-02.1 78.34 0.12241 92 28.6 17 136.0 232.7 458.0 2. Per City criteria, Pond routing was completed using the DA-02.2 35.62 0.05566 92 17.5 11 75.6 129.3 253.8 Unit Hydrograph - SCS Method. DA-03 5.18 0.00810 86 13.3 8 9.7 18.6 40.0 1 J.Increases in discharge due to proposed site development DA-04 24.77 0.03870 89 19.6 12 44.6 80.7 165.5 1 are anticipated to be mitigated using the detention pond. DA-05 26.62 0.04160 95 15.9 10 65.6 106.4 201.3 1 Increases will occur immediately downstream of the site, DESIGN POINT SUMMARY This increase is proposed to minimize the impacts within the watershed as a whole. (Please refer to Drainage Study al (cFS) 05 (cFs) 0100 (CFS) (DS-24-01Y) for additional information. Basin ID Ex PROP A Ex PROP A Ex PROP A 4. At least 1.00' of freeboard is provided in the detention DP-0 53.3 39.9 -13.4 121.4 80.2 -01.2 298.0 178.5 -119.5 pond for the f00-year storms events and 0.5' of freeboard DP-04 79.1 71.5 -7.6 191.8 179.3 -12.5 497.4 584.2 86.8 for dogged conditions. 0 teague Hall and perkins, inc scale City of Fort Worth, Texas y tnp proj6ff GLP23338 ha,;� 5237 N. Riverside Drive, Suite 100 1..=500r Improvements for sheet Fort Worth, Texas 76137 vort HIGH SCHOOL #4 817.336.5773 ph 817.336.2813 fx N(A 7 date SWFMA EXHIBIT -w Mpinc.com of TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 t POST -PROJECT DRAINAGE AREA MAP 26 TIME OF CONCENTRATION CALCULATION Sheet Flaw Component Shallow Flow Component Pipe Flaw Component Total Tmd Basin Length 'n' Slope P21nl Veloc Travel Sheet Length Length Slope Veloc Travel S J."'no Pipe 'n' Slope Vedas Travel Pipe Ift'; value Iflf fl) 2-yr,24hr (Ipsl Time Plow unpaved Paved (IIj If) (fps) Time 101 Din vdue (ft/N) (fps) Tlme Flow ptlin) Tone rrti (nen) (in) (min) Tlme Mn PrwhsAW Cmdr nc 0"l 1DODD 0.1500 09038 3M 0JV 1f115 I8.15 5W-94 0.00 OD366 3-09 324 324 CLOD tyA W402 IODIIO CLI5.00 000'� 3522 QIO I(t26 1626 122300 OI!(i 00123 I�LI IIJ2 11�2 CL00 A DA-03o IOD,OUiil15L1400060 35M Ql1 Isi12 15.12 816.* 0100 00230 2.4S SW S56 CLOD A DA.ODh 100- D 0-IS00 00230 3522 0:9 SB0 RM IM6.0D 000 00443 3-42 620 620 G-OD N/A M-04 I0DflO 0150D 00186 35" 0- 7 961 961 44M 06624 00110 211 7.18 7-19 1300 =0 A--ed Vc*. By I 8D6 1 278 1 276 Past PruiW Gtadium -51 1622 I l I7.98S00 I IrnipnA-o7 IOO.OD 01511D 007MI 35" 0.18 934 934 255M 00720 87I 1.95 193 A --rood Vduci 6.72 PropDi403 100M CLI500 005W 3522 026 647 &0 1.%6jMD 000 00390 102 6$7 6$7 CLOD ��00 TIME OF CONCENTRATION CALCULATION, CON'T Channel Flow Component I Final T[ [alculalion Depth Tara] 8onom of 55 'n' slope Veb[ Travel OtmneI Tdal Tiiswaf SCS Avg IPncrh (ft widlh(fl) Flow (fkVJ vdue (ff/fl) (fps) Time Flow Length Canc Logtime Vela (a) (nYn) Time (Mn) (ft) (min) (min) (ftisas) 2,107_93 Assustl� ylksCily 6110 `# 586 2006 27�/ 16 172 Oc10 N/ ODD 0.00 OEM 13M 27-% 17 0.80 1,$70M Asa■snvlr *.IY 600 S.19 5.19 3786 2i87 16 139 000 WA 000 090 000 13M 1503 9 132 ODD I A:a■rs0sf V0Y.1y 600 eon am 1478 1957 12 1106 300.00 Asn■nOdVelusly 6-00 179 IJ9 I:L80 $ 2.08 I ODO N/A 0.00ODO 11f110 E 265717 =000 N/A am 000 am 1751 11 301 1 000 N/A 0.00 ODD 0.00 1:L45 13 % 8 1.68 1 League Hall and perkins, ins 5237 N. Riverside Drive, Suite 100 scale h,,;z N/A ♦ Cit of Fort Worth, Texas Y Improvements for mp prola r/ GLP23338 sheet FortTexas 1 817.336.5773 ph 817.336.2813 fx www.tnpinc.com NA date t P HIGH SCHOOL #4 SWFMA EXHIBIT 8 of TBPELS: ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 TIME OF CONCENTRATION 26 STA_0+00.00 SD UNE N" _ (,V L—t USH — WA ✓ 0.40 11111111 3,,2.71:X teague nail and inc SFa�e perkins, 5237 N. Riverside Drive, Suite 100 1 "=20' Fort Worth, Texas 76137 v rt N(A 817.336.5773 ph 817.336.2813 fx date www.tnpinc.com TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 tnp I UP 0 City of Fort Worth, Texas tnp ( GLP23333338 Improvements for sheet HIGH SCHOOL #4 9 SWFMA EXHIBIT of POND OUTFALL PLAN 26 740 Cn O J w w Of \ "' 9 94 W W N N 740 SCALE: HOR.• I" = 40' VER.• 1 " = 4' NORMAL PERMANENT POOL POND ELEVA 17ON WSEL=732.50 0 W C a J w O J of W L L_ -0+50 0+00 1 +00 1 +25 SD LINE N' 730 720 City of Fort Worth, Texas tnp pro,ecr teague nail and perkins, inc Shape Y oriz GLP23338 5237 N. Riverside Drive, Suite 100 N.T.S. Improvements for sheet Fort Worth, Texas 76137 vert HIGH SCHOOL #4 817.336.5773 ph 817.336.2813fx N.T.S. 10 --Mpinc.com dateKtn SWFMA EXHIBIT of TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 POND OUTFALL PIPE PROFILE 26 SWFM s� — _ — BOUNDARY _i -N x S" ' BOUNDARY -a Scale Cityof Fort Worth, Texas tnp pro,6cf teague nail and perkins, inc hori. GLP23338 5237 N. Riverside Drive, suite 100 "-1 25' Improvements for sheet Fort Worth, Texas 76137 rt HIGH SCHOOL #4 817.336.5773 ph 817.336.2813fx N/A 11 --Mpinc.com date4tn SWFMA EXHIBIT of TBPELS: ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 P POND EASEMENT 26 i 760 760 750 r✓� r .r, 750 WEAR • MA 740 ►VormdPb�Et »,�' _ 740 _,. 730 1�►1 4 730 rr ,-�__ , 720 __N� 720 710 1 I I I I� ' any 710 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 DETiENTI►01N POND MW SECTIr011V A -A' 750 two MR wsa: 7J9 50• Iftwo WM *M- 7J680' 750 orma/ Pod 740 �' EL ,J2-W f 740 730 :�„ 730 720 f 720 710 710 0+00 1+00 2+00 3+00 4+00 Scale Cityof Fort Worth, Texas tnp proldtf teague nail and perkins, inc horiz GLP23338 5237 N. Riverside Drive, Suite 100 N.T.S. Improvements for sheet Fort Worth, Texas 76137 Vert HIGH SCHOOL #4 817.336.5773 ph 817.336.2813fx N.T.S. 12 www.tnpinc.com date SWFMA EXHIBIT of TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 GRADING CROSS SECTIONS 26 i 'll \ r r v goo :> oaf MOOR FOOTBALLARENA L 8TAONM RACT� NNW FACLRYGHfifm Go" GH4W GEM �. a+i0 O++io &N4w NNW aii0 a+0 \ \ / WHM GHNN I1 O�i +o a+ oGHW - \ nnunnnnnnuuuuuir �� � // o l ' a;uiiuiiuiiummimuuuia ° ° 0 200 400 tnp prole&' tea ue nail and erkins, inc scale City of Fort Worth, Texas 5 p haa: GLP23338 5237 N. Riverside Drive, Suite 100 1 n=400r Improvements for sheet Fort Worth, Texas 76137 vert HIGH SCHOOL #4 817.336.5773 ph 817.336.2813 fx N/A 13 www.tnpinc.com date SWFMA EXHIBIT of TBPELS: ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 VICINITY MAP 26 SPILLWAY — MON& PLAN IsEXI 741 % to > > SPILLWAY OVERFLOW 736.25 7Z 735 NORMAL POOL 73250 CONCRETE SPILLWAY 1.5 TO 1.0 73.' LEADING \\\Z725 00 FLA1WYh4K EDGE 730 72�GY DIS�PA7/AY S1EP 724.82 725 > 7 > �TRAIUNG FLATWbRK EDGE 720.60 p5 DRIVE ELEI/A770N 72270 _ > 1� > > SLOPE TO DRAIN > \ '1 720 72C — IF \ 'UMMIL IL PAVING' \ \ CONCRETE FLATWORK 71 `GROUTED ROCK RIP -RAP DEEPENED EDGE (nPICAL) 715 SECTION I — SPILLWAY VER77CAL EXAGGERA 110N x1.5 fiP O scale teague nail and perkins, inc . City of Fort Worth, Texas Y tnp pro,Afr GLP23338 horiz 5237 N. Riverside Drive, Suite 100 j "=20r Improvements for sheet Fort Worth, Texas 76137 Vert HIGH SCHOOL #4 817.336.5773 ph 817.336.2813fx N.T.S. 14 --Mpinc.cora date SWFMA EXHIBIT of TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 SPILLWAY INFORMATION 26 740.50' - 739.00' - 737.75' - 736.25' - 736.23 733.50'- 732.50'- - 3'x3' RCB FL=722.0� 100YR Clogged Conditions 739.90' 100YR WSEL 739.50'� 280' \ 0 o 8' �4.7 ' � 6' fLO t RCB Orifice Opening OPEN AREA - NORMAL POOL I I 31.875 FT? = 732.50' 4. I I FLOW l _ 8, TOP VIEW DETENTION POND OUTLET STRUCTURE (NOT TO SCALE) OUTLET RATING CURVE Elevation Discharge Elevation Discharge Elevation Discharge Elevation Discharge Elevation Discharge Elevation Discharge (h) (ch) (h) (ds) (h) (cis) +` (it) (cis) (h) (.Fs) 00 (cis) 732.11 1.01 111.01 11.11 111.10 11.30 736.90 178.82 738.40 137.65 739.90 111111 732.60 3.24 73430 47.97 735.60 73.71 737.00 183.15 738.50 244.35 740.00 1174.99 732.70 1,47 -21 10.07 735.70 75.11 737.10 186.49 7-60 25135 740.10 1308.35 732.10 9.70 734.30 12.12 735,10 76.12 737,20 M87 731170 25862 740,20 1447.63 732.90 12.93 734.40 54.08 735.90 77.97 737.30 191.35 738.80 266.15 740.30 1592.56 733.00 16.16 734,50 56.02 736.00 79.20 737.40 193.91 738.90 273.94 740.40 1742.94 733.10 19.41 -61 17.84 -10 -49 737.50 196.54 7-00 211.97 740.50 1191.55 733.20 22.65 734,70 59.63 736.20 BLED 737.60 199.26 739.10 315.56 NOTE: Bentley's 733.30 25.87 -11 61.32 -21 12.41 737.70 202.06 7-21 -31 PondPad(use1 to 733.40 29.10 734,90 63.03 736.30 117.03 737.80 205.23 739.30 439.03 create rating curve. 733.50 32.33 735.00 64.66 736.40 143.56 737.90 209.42 739.40 518.98 733.60 35.43 735.10 -25 736.50 15681 738.00 214.23 7-11 -61 733.70 38.27 735.20 67.84 736.60 163.41 738.10 219.52 739.60 707.05 733.80 -91 735.30 69.33 731.70 1-11 738.20 225.21 7-70 913.41 733.90 43.36 735.40 70.84 736.80 174,17 738.30 231.26 739.80 927.16 POND VOLUME SUMMARY Elevation Area Incr. Volume * Cuml. Volume Comments (ft) (acres) (acre-fi) (a-ft) 732.50 2.70 0.00 0.00 Normal Pool 733.00 2.73 1.36 1.36 1 734,00 2,84 2,78 4,14 735.00 3.56 3.19 7.34 736.00 3.92 3.74 11.07 1 737.00 4.20 4.06 15.13 1 738.00 4.51 4.35 19.49 1 739.00 4.81 4.66 24.15 740.00 5,10 4.95 29.10 740.50 5.14 2.56 31.66 Top of Pond *Conic Method: V=(1 /3)(1-12-1-1 1)[(Al +A2+(A 1 *A2)AO.5)] scale teague nail and perkins, inc hori: 5237 N. Riverside Drive, Suite 100 N/A Fort Worth, Texas 76137 vert 817.336.5773 ph 817.336.282813 fx N/A www.tnpinc.com date tn TBPELS: ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 OUTLET RATING CURVE(SPILLWAY) EI-ol..n Discharge Elevari.ni Discharge (h) L' (h) (cis) 736.30 0.13) 738.50 58.02 1 736.40 0.70 738.60 64.37 1 736.50 1.50 738.70 7"00 1 736.60 2.48 738.80 77.89 I 1 736.70 3.62 738.90 85.04 1 736.80 4.89 739.00 92.44 1 736.90 6.28 739.10 125.40 1 737.00 7.78 739.20 179.57 1 737.10 9.39 739.30 247.62 1 737.20 11.10 739.40 326.93 1 737.30 12.89 739.50 415.99 1 737.40 14.78 739.60 513.76 1 737.50 16.75 739.70 119,11 1 737.60 18.81 739.80 732.63 1 737.70 2094. 739.90 852.17 737.10 23.44 740.00 -24 737.90 26.99 740.10 3111.99 738.00 31.14 740.20 1250.66 738.10 35.77 740.30 1394.98 738.20 40.81 740.40 1544.75 738.30 46.22 740.50 1699.77 738.40 51.96 I NOTE: Bentley's Pond Pack used to create rating curve POND FLOW SUMMARY Return Event Pond Inflow Pond Outflow WSEL Peak Storage) (years) (cfs) (cfs) (ft) (ao-ft) 1 247 70 735.30 8.6 1 5 427 176 736.80 14.4 1 100 847 572 739.50 26.4 City of Fort Worth, Texas mPGLPprolaff 233383338 Improvements for sheet HIGH SCHOOL #4 15 SWFMA EXHIBIT of POND STRUCTURES 26 j FL 720.55—\ teague nail and inc 5cal Perkins, h*rie 5237 N. Riverside Drive, Suite 100 1 "=200' Fort Worth, Texas 76137 v rt N(A 817.336.5773 ph 817.336.2813 fx date www.tnpinc.com TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 TEMPORARY DRAINAGE PIPE TO BE INSTALLED FOR SKIMMER .r a tnp ,�R�JI/ND WETLAND((~� 1 A YI RF RFMn p6TRR 'LEGEND 13 Row DAM ® KET PROM177 W �O— MFQMY PavaE caysmucnav EYMMOEAXT tnp Q City of Fort Worth, Texas tnp / GLP23333338 Improvements for sheet HIGH SCHOOL #4 16 SWFMA EXHIBIT of EROSION CONTROL PLAN 26 Jq ROCK I 12" MIN. A 1 EROSION CONTROL NOTES (TNP) 1. STABILIZED CON6IRUC110N EXITS SHALL BE USED BY ALL PROJECT VEHICLES LEAVING THE CONS7RUC770N AREA. WHEEL WASHING EQUIPMENT SHALL BE USED TO REMOVE EARTHEN MATERIALS FROM WHEELS AND VEHICLES. 2. CONTRACTOR SHALL ENSURE THAT NO STORMWA7ER RUNOFF ENTERS DRAINAGE SYSTEMS OR EXITS THE CONS7RUC77ON AREA WITHOUT PASSING THROUGH ROCK BERMS/EROSION CONTROL DEVICES 3. CONTRACTOR SHALL PROVIDE STREET CLEANING ON ADJACENT STREETS AS NECESSARY TO REMOVE EARTHEN MA7FR/ALS TRANSPORTED FROM THE CONSTRUCRON AREA. 4. NO OIL OR HAZARDOUS MATERIALS SHALL BE STORED /N THE CONS77?UC77ON AREA. 5. 7HESE PLANS SHALL BE USED /N CON✓UNC77ON WI7H THE ACCOMPANYING DOCUMENT EN7710, POLLU77ON PREVEN77ON PLAN". 6. ALL EROSION CONTROL DEVICES ARE TO BE REMOVED BY THE CON7RACTOR AF7FR THE PROJECT /S COMPLETE AND SUBSTAN77AL STAB/L/ZA77ON /S ACHIEVED. r 12" MIN, FACE OF CURB EDGE OF GUTTER FILTER FABRIC SECURED TO 2"X4' WIRE MESH BELOW A 2- 4" WIRE ••ROCK SAG TO MESH PREVENT FLOW - UNDER 2"X4" WIRE MESH 2"X4" WIRE WEIR CURB INLET PROTECTION teague nail and perkins, inc 5237 N. Riverside Drive, Suite 100 Fort Worth, Texas 76137 817.336.5773 ph 817.336.2813 fx www.tnpinc.com TBPELS: ENGR F-230; SURV 10011600, 10011601, 10194381 scale horiz N/A N/A date IN MAY 2025 NOTES: GENERAL • DRAINAGE PATTERNS SHALL BE EVALUATED TO ENSURE INLET PROTECTION WILL NOT DIVERT FLOW OR FLOOD THE ROADWAY OR ADJACENT PROPERTIES AND STRUCTURES. • INLET PROTECTION MEASURES OR DEVICES THAT COMPLETELY BLOCK THE INLET ARE PROHIBITED. THEY MUST ALSO INCLUDE A BYPASS CAPABILITY IN CASE THE PROTECTION MEASURES ARE CLOGGED. • A POSITIVE OVERLOW PATH SHALL BE CONSIDERED IN THE DESIGN OF INLET PROTECTION CONTROL MEASURED AT SUMP INLETS. nI IRR INI FT PRDT-TInN • MUNICIPALITY APPROVAL IS REQUIRED BEFORE INSTALLING INLET PROTECTION ON PUBLIC STREETS. • SPECIAL CAUTION MUST BE EXERCISED WHEN INSTALLING CURB INLET PROTECTION ON PUBLICLY TRAVELED STREETS OR IN DEVELOPED AREAS. ENSURE THAT INLET PROTECTION IS PROPERLY DESIGNED, INSTALLED AND MAINTAINED TO AVOID FLOODING OF THE ROADWAY OR ADJACENT PROPERTIES AND STRUCTURES, • A TWO INCH OVERFLOW GAP OR WEIR IS REQUIRED ON ALL CURB INLET PROTECTION DEVICES. • TRAFFIC CONES, WARNING SIGNS, OR OTHER MEASURES SHALL BE INSTALLED TO WARM MOTORISTS WHEN THE INLET PROTECTION MEASURES EXTEND BEYOND THE GUTTER LINE. • 2"X4" WEIR PROTECTION: BEND WIRE MESH AROUND THE 2" X4" BOARD AND STAPLE TO THE BOARD. BEND WIRE MESH AROUND THE BOTTOM OF THE BOARD, THE CURB OPENING, AND ALONG THE PAVEMENT TO FORM A CAGE FOR THE ROCK. ROCK BAGS SHALL BE PLACED PERPENDICULAR TO THE CURB, AT BOTH ENDS OF THE WOODEN FRAME, TO DISRUPT THE FLOW AND DIRECT WATER INTO THE ROCK FILTER. STACK THE BAGS TWO HIGH IF NEEDED. • 2"X4" WIRE (HOG WIRE) WEIR PROTECTION THE FILTER FABRIC AND WIRE MESH SHALL EXTEND A MINIMUM OF 12 INCHES PAST THE CURB OPENING ON EACH SIDE OF THE INLET. FILTER FABRIC SHALL BE PLACED ON 2" X 4" WIRE MESH TO PREVENT THE TUBE FROM SAGGING INTO THE INLET. ROCK BAGS ARE USED TO HOLD THE WIRE MESH AND FILTER FABRIC IN CONTACT WITH THE PAVEMENT, AT LEAST ONE BAG SHALL BE PLACED ON EITHER SIDE OF THE OPENING. PARALLEL TO AND UP AGAINST THE CONCRETE CURB. THE BAGS ARE INTENDED TO DISRUPT AND SLOW THE FLOW AND ENSURE IT DOES NOT GO UNDER THE FABRIC, ADD BAGS IF NEEDED. ROCK BAGS 2" GAP 2"X4" WIRE MESH FILTER FABRIC SECURED TO 2"X4' WIRE MESH FILTER FABRIC SECURED TO 2"X4' \/\\ WIRE MESH LEAVING \ 2 2" GAP FOR // WIRE MESH OVERFLOW BETWEEN MESH \ TOP OF INLET THROAT AND TOP OF FABRIC /.1 EXISTING CURB INLET (ALL TYPES) CITY OF FORT WORTH, TEXAS REVISED 04-30-2021 2"X4" WIRE WEIR 01 57 13-D430 CURB INLET PROTECTION tnp City of Fort Worth, Texas mPGLP233383338 Improvements for sheet HIGH SCHOOL #4 17 SWFMA EXHIBIT of EROSION CONTROL DETAILS (1 OF 2) 26 vent Rope with Blue Inlet 4" Sch 40 tip coupling 2" Sch 40 SOLID pvc connection barrel or "arm" SUPPLIED BY USER 2/° hose \i II(( � Skimmer shown in I 3" inlet P�rk.5,8N1,)51 floating position ertension J 'NOTE- SMALL SKIMMER SHOW FAR ILLUSTRATIVE PURPOSES ACTUAL SKIMMER SIZE TO BE BUNCH AVAILABLE FROM d W. FASaOTH It SOR W SILT FENCE N07ES L SILT FENCE MAY BE USED WHERE THE GROUND SLOPES ACROSS A DITCH OR SWALE 2 STEEL POSTS IIHICH SUPPORT THE SILT FENCE SHALL BE INSTALLED ON A SLIGHT ANGLE TOWARD THE ANTIC%PATED RUNOFF SOURCE THE PAST MUST BE EMBEDDED A MINIMUM OF ONE FOOT J. THE TOE OF THE SILT FENCE SHALL BE TRENCHED IN TWIN A SPADE OR MECHANICAL TRENCHER SO THAT THE DOMNSLOPE FACE OF THE TRENCH IS FLAT AND PERPENDICULAR RT THE LINE OF THE FLOW. 4. THE TRENCH MUST BE A MINIMUM OF 6' DEEP AND 6' WIDE RT ALLOW FOR THE SILT FENCE FABRIC 70 BE LAID IN THE GROUND AND RAO(FILLED WIN COMPACTED MATERIAL a THE SILT FENCE SHOULD 6£ SECURELY FASTENED 77 EACH STEEL SUPPORT POST ALTD?NATIVELY, SILT FENCE SHALL BE FASTENED TO MOVEN CURE MNICH IS FASTENED 70 THE STEEL POST. THE ENDS OF FABRIC SHALL OVERLAP THREE FEET. 6. INSPECTION WALL BE MADE NEEIQY AND AFTER EACH RAINFALL REPAIR OR REPLACEMENT SHALL BE MADE PROMP7LY AS NEEDED 7. SILT FENCE WALL BE REMOVED MNEN THE SITE IS COMPLETELY STABILIZED SO THAT NATURAL DRAINAGE IS NOT BLOO(ED DR IMPEDE. 6. ACCUMULATED SILT SHALL BE REMOVED WHEN IT REACHES A DEPTH OF HALF THE EIGHT OF THE FENCE THE SILT WALL BE DISPOSED OF AT A 97E APPROVED BY THE OWNER AND IN SUCH A MANNER AS 70 PREVENT ADDITIONAL SILTATION 9. CONTRACTOR RT MAINTAIN SILT FENCING AND ALL OTHER EROSION CONTROL MEASURES A T ALL TIMES DURING THE DURATION OF THE PRO.ECT. la THE SILT FENCE LOCA770V SHOW IS APPROXIMATE CONTRACTOR SHALL INSTALL SILT FENCE AS NEC'SSARY TO PRESERVE AND PROTECT DUSTING TREES, FENCES AND VEGETATION ALONG PROPERTY LINES 11. C INNTRACTOR SHALL STAKE THE PROPERTY UNE BEFORE SETTING SILT FENCE `SM PDNF Pafl (E' 9-AM tuc r' annnTT Yr.) TIP. \NnaPfiERFU mPn)PRO°NSE FARW \41' off aw BIOr74G' RT PO/S AK HT. M' AWIE MT.. GIVIAW) r \Fmw 7--N W Dal I1140M • CENFA m) ROM REAM NOTES 1. USE ONLY (OPEN GRADED ROW 4-6 INCHES IN DIAMETER FAR STREAM FLOW CONDITION. 2 THE ROC BERM SHALL BE SECURED W771 A 141 MIRE SHEATHING HA MNG A MAXIMUM OPENING OF 1' AND A MINIMUM MIRE SIZE OF 20 GAUGE AND SHALL BE BURIED IN A TRENCH APPROXIMATELY J TO 4 INCHES DEEP. J THE ROCK BERM SHALL BE INSPECTED MEEKLY OR AFTER EACH RAIN EVENT AND SHALL BE REPLACED WHEN THE STRUCTURE CEASES TO FUNCTION AS INTENDED DUE R) SILT AOCUMUUTION AMONG THE ROCK$ WASHOUT, CONSTRUCTION TRAFFIC DAMAGE, ETC 4. WHEN SILT REACHES A DEPTH EQUAL 70 ONE—THIRD OF THE HEIGHT OF THE BERM OR ONE FOOT, 111i EVER IS LESS, ONE 57LT SHALL BE REMOVED AND DISPOSED OF PROPERLY. S WHEN THE 9TE /S COffKMY STABLIZED, TIE BERM AND ACCUMULATED SILT SHALL BE REMOVED AND D1910SED OF IN AN APPROVED MANNER. 6. ROCK BERM SHOULD BE USED AS OIEOC DAMS FOR CONCDOP4TED FLOW AND ARE NOT INTENDED FOR USE IN PERIMETER PROTECTION. 1. A STABILIZED CONSTRUCTION ENTRANCE APPLIES TO POINTS OF CONSTRUCTION INGRESS AND EGRESS WHEN£ SEDIMENT MAY TRACKED OR FLOW OFF THE CONSTRUCTION 97E 2 THE ENTRANCE WALL BE MAINTAINED IN CCWDITIAV TWOCH CULL PREVENT TRACKING OR FLOWING OF SEDIMENT ON70 PUBLIC RIGHTS —OF— WAY. THIS MAY REQUIRE PERIODIC TAP DRESSING WITH ADDITIONAL STONE OR ADDIRGVAL LENGTH AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED ONTO PUBLIC RIGHTS —OF —WAY MUST BE REMOVED IMMEDIATELY. scale City of Fort Worth, Texas tnp proleC( teague Hall and perkins, inc hP,;z . Y GLP23338 5237 N. Riverside Drive, Suite 100 N/A t Improvements for sheet Fort Worth, Texas 76137 vert HIGH SCHOOL #4 817.336.5773 ph 817.336.2813fx N/A 18 --tnpinc.com date SWFMA EXHIBIT of TBPELS: ENGR F-230; SURV 10011600, 10011601, 10194381 MAY 2025 EROSION CONTROL DETAILS (2 OF 2) 26 SLAB OF DENSE LIMESTONE fROM A MONOLITHIC SEAM INCLINED OUT OF WATER AT MIDPOINT CONTINUOUS - POND LINER FILL VOIDS OF ROCK PEIR NTH GRAVEL/CEMENT STABILIZED SAND SLURRY HABITAT SHE txxe, n.TA N07ES • EACH OF THE 2 LIMESTONE SLABS SHALL HAVE A MINIMUM WDTH DIMENSION OF 7 FEET AND A DEPTH SUFFICIENT TO PREVFNT BREAKAGE DURING TRANSPORT AND INS7ALLA7I0N. STONE SHALL BE INSTALL FREE OF SCRAPES OR MECHANICALLY CAUSED BLEMISHES. PROVIDE A DIRECT ROUTE TO THE OPEN WATER FROM EACH SLAB BETWEEN PLAN77NGS FOR USE OF 7URTLES ALIGN THE AXIS OF THE 77LT OF THE SLABS TO MAXIMIZE THE MORNING SUN ANGLE. • ROCK PEIR SHALL BE INSTALLED IN LAYERS OF WELL FIT TOGETHER, STRUCTURALLY SOUND ROCK OF SIZES VARYING FROM 12 TO 18 INCHES. THE VOIDS OF THE PREVIOUS LAYER SHALL BE FILLED WITH GRAVEL/CEMENT STABILIZED SAND SLURRY. • 7HE SOGGY MATERIAL EXCAVATED FROM THE EXIS77NG PONDS ON SITE MAY BE USED AS THE HABITAT SHELF PLAN77NG MEDIUM. THE EXISTING VEGETA7ION IN THE PONDS CAN BE SHREDDED AND MIXED IN WITH THIS EXCAVATED MATERIAL FOR BEST RESULTS PROVIDED THAT ALL ORGANIC AND INORGANIC MATTER IS SUMCIENFLY SMALL TO OFFER NO IMPEDIMENT TO PLANTING. A LAYER OF CLEAN SOIL NITHOUT EXTRA ORGANIC MATERIAL SHOULD BE SPREAD OVFR THE TOP PRIOR TO POND FILLING AND PLANTING. • ENSURE THAT ALL PLANTS ARE POS177ONED VERTICALLY SUCH THAT THE TOP OF THE ROOT BALL IS SUMCIENRY CLOSE TO THE WATER SURFACE. FOLLOW GRONERS RECOMMENDA77ON BY SPECIES I—AQUA77C PLANTS REF LANDSCAPE PLANS I—ELEV. = 723.50 SILTY TO SANDY LOAM_ LOOSLY FORMED ON TOP OF CLAY LINER GENERAL NOTES.- 1.THE POND SHOULD BE 7REATED NTH GYPSUM (CALCIUM SULFATE) BEFORE FINAL ACCEPTANCE TO CLEAR THE WATER OF SUSPENDED CLAY PAR77CLES THROUGH FLOCCULATION AFTER FULL GROUND COVER HAS BEEN ESTABLISHED OVER ALL DISTURBED PERVIOUS AREAS ONCE THE POND HAS BEEN FILLED TO THE NORMAL POOL ELEVA770N, AND THE AERATORS HAVF BEEN INSTALLED, TREATMENT MAY BE APPLIED EVENLY ACROSS THE SURFACE OF THE POND FROM A BOAT. DOSAGE WILL VARY, AND AN EN77TY FAMILIAR WITH LARGE PONDS SHOULD BE CONSULTED FOR PRELIMINARY 7ES77NG BEFORE LARGE SCALE APPLICA770N. 2, MAXIMUM STORAGE VOLUME SHALL BE VERIFIED PRIOR 70 FINAL ACCEPTANCE. FINAL VOLUME HILL BE ESTABLISHED THROUGH A SURVEY CONDUCTED BY A LICENSED LAND SURVEYOR. THE MAXIMUM IMPOUND VOLUME SHALL NOT BE EQUAL TO NOR EXCEED A 7HRESHOLD OF 50ACREFT AS MEASURED FROM THE POND SIDE FLOW LEVEL OF THE EMERGENCY OUTFLOW PIPE. ENGINEER HAS NOT PROVIDED ANALYSIS NOR DESIGN N11CH WOULD BE REQUIRED FOR THE CONSTRUCTION OF A DAM ENGINEER HAS DESIGNED GRADING OF THE S17E SUCH THAT THE MAXIMUM STORAGE VOLUME NHICH CAN BE IMPOUNDED BEHIND THE BERM FALLS BELOW THE REGULATORY THRESHOLD OF A DAM. SHOULD A VOLUME IN EXCESS OF THE REGULATORY THRESHOLD BE MEASURED, THE CONTRACTOR WILL NO77FY THE ENGINEER OF RECORD AND PROVIDE A MECHANISM OF REMEDIAT70N TO BRING THE MAXIMUM STORAGE VOLUME BELOW A THRESHOLD OF 50ACREFT. J. CONTRACTOR SHALL PROVIDE A 24' CLAY LINER AT THE BOTTOM AND SIDES OF THE POND TO MINIMIZE SEEPAGE. THE CLAY MATERIAL USED SHALL HAVE A MINIMUM PI OF 25. CLAY SHALL BE PLACED IN 6-INCH LIFTS AND COMPACTED TO A MINIMUM OF 98% OF THE MAXIMUM DENSITY AS DETERMINED BY ASTM D 698 (STANDARD PROCTOR) TO AT LEAST +3 PERCENTAGE POINTS OF ITS OPTIMUM MOISTURE CONTENT. 4. GRAWL/CEMENT STABILIZED SAND MIXTURE SHALL CONSIST OF THESE DRY INGREDIENTS BY VOLUME 55% GRAVEL PASSING 1RN AND RETAINED BY 11N SIEVE 20% GRAVEL PASSING �N SIEVE 35% CEMENT STABILIZED SAND AQUATIC PLAN77NGS REF LANDSCAPE PLANS FLAT MOSS BOULDER 2 (SIZE AND SHAPE VARY) WATER SURFACE :\ MINIMUM TOP AREA OF 4SQFT ABOVE WATER � EXISTING GRADE � FILL AND TAMP VOIDS BE7NFEN ROCK RIP -RAP WITH A DRY MIXTURE OF GRAVEL, SAND, AND PORTLAND CEMENT DISCON77NUE ` STONE DUST BEDDING VOID FILL AT 720 ELEV LAYER N lT1NIMUMJ CONTINUOUS POND LINER STEPPING STONE AND HEADWATER 50ALE: N.T.S. teague nail and perkins, inc 5cale horiz 5237 N. Riverside Drive, Suite 100 N/A Fort Worth, Texas 76137 v rt 817.336.5773 ph 817.336.2813fx N/A www.tnpinc.com date tn TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 EXIS77NG NERAND DO NOT DISTURB LOOSE nACKFILL NTH MATERIAL EXCAVATED FROM EXISTING POND EDGE --MIN 41N OF THE GRAVEL/SAND MIX HYDRATED IN MIXER AND POURED AS SLURRY ON UPS7REAM SIDE AND BETWEEN STEPPING N07ES STONES • NET FILL MIX AFTER PLACEMENT TO BEGIN HARDENING PROCESS • MAINTAIN P05177W SLOPE OF CLAY LINER TOWARD POND • DIMENSION H VARIES DUE TO RELA77ONSHIP OF EXISTING GRADE TO PROPOSED POND WATER SURFACE. ADJUST BOULDER SIZE/tlEPTH AS NECESSARY AS H INCREASES • SPACE STEPPING STONES LINEARLY APPROXIMATELY 30' C-C • BRUSH THE POURED GRAVEL MIX BETWEEN STEPPING STONES NTH A MOIST SPONGE AFTER POURING TO EXPOSE THE SURFACE OF THE LARGE CRAWL AFTER SIGNIFICANT DRRNG, CLEAN THE GRAVEL AND STEPPING STONE SURFACES WITH MURIA77C ACID SOLUTION TO REMOVE ANY RESIDUAL CEMENT PASTE. FINISH SURFACES KITH A THOROUGH RINSE TO REMOVE ANY ACID. City of Fort Worth, Texas I tnp projeer GLP23338 Improvements for sheet HIGH SCHOOL #4 19 SWFMA EXHIBIT of POND DETAILS (I OF 5) 26 i ` 1 1 • 1' 1 PLAN PLANTING %06EVON 6" OF SANDY SOIL WITH HIGH CONCEN IRA 77ON OF ORGANIC MATTER LOAM TO CLAY LOAM SOIL LIGHTLY COMP NICK DRAINS EXTENDING DOW BELOW WATER SURFACE ELEVA77ON (INSTALLED 24• C-C) �7 FILL TOP SURFACE KOIDS WITH GRAVEL A dHT SURFACE/ - MEDIUM STONES VARI7NG FROM 6 TO 12 INCHES 77GH7LY INTERLOCKED MIDNATER I5LET 5GALEr N.T.S. PROLEC77ON OF TIPICAL POND BERM GRADE (4:1) CONCRETE GROUT THE SLOPE SURFACE AND IN BETWEEN THE ROCKS TOP AND BOTTOM LEDGE KITH FORMED SIDE (MOW S7RIP FOR \ �— CRD95110 11E WRE CONI 11ON AT OWN ED6m 77E WIRE OUTER EDGE OF GABION BASKETS NOTES • DECREASE THE STACKED ROCK HEIGHT ON THE fRONT SIDE OF THE ISLET NITHOUT SHOWING THE GABION BASKETS BELOW AND INCREASE THE ROCK HEIGHT ON THE BACK SIDE OF THE ISLET • AT PLANTING LOCA77ONS DO NOT CUT THE WICK DRAINS BACK, INSTEAD LEAVE THEM AT FULL LENGTH AND ALLOW THEM TO REST AGAINST THE SIDES OF THE PLAN77NG HOLE • 77E WIRE CROSS CONNECTING GABIONS SHALL BE 7 GAUGE (A IN) VINYL COATED STEAL WIRE ROPE OR ALUMINUM WTH AN EQUIVALENT TENSILE STRENGTH, INSURING CORROSION RESISTANCE "*FRONT — 2NO LINE OF UPRIGHT OR J- STACKED ROCK i 3~ q PLANTINGS Q -REF LANDSCAPE PLANS m o _ LOA�EXTEN G BELLIN€j Z 77E WIRES CONNECTED TO BASKET JJJ EDGES AT INTERVALS OF 6FT OR LESS CRISSCROSSING THE EN77RE ISLET -�:r3=6ABI0N BASKET -18FT AT WIDEST SECTION OF ISLET I CONTINUOUS POND LINER - T VN i INSIDE EDGE OF BERM TOP AS DEPICTED ON PLANS 1 v 1� "--WOVEN CE07EX77LE FABRIC STAKE INNER CORNERS BENCH CUT POND BERM I:I ( ROUTED Rn(',K RIP RAP SCALE: N.T.S. City of Fort Worth, Texas tnp pro,ecr teague nail and perkins, inc shale Y oriz GLP23338 5237 N. Riverside Drive, Suite 100 N/A Improvements for sheet Fort Worth, Texas 76137 rt ^,6, HIGH SCHOOL #4 817.336.5773 ph 817.336.2813 fx IZAt 20 --Mpinc.com dateKtn SWFMA EXHIBIT of TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 P POND DETAILS (2 OF 5) 26 CONCRETE RIP RAP 5/N fLA7Wr1RK CAP FlNISHED GRADE AS CALLED OUT ON 5IN FLA T*VRK CAP--,,, PLAN 7' T _�—. NO 3 BAR 012' O.C. g 20 NO 3 BARS ® 12' �—O.aaw 12IN ENERGY D1551PATION DROP WALL_ SCALE: N.T.5. LA77CE GRID PAVERS �FlNISFIED GRADE LAID W17H NCH GAP BETWEEN BLOCKS 1 INCH STONE DUST BEDDING MA7ERIAL 1 12IN MIN I 1, A. SIN THICK COMPAC70' FLEXBASE LATIG3= 5RID PAVER PATHWAY SCALE: N.T.S. MlN 6' rOP SOIL MOSS BOULDERS (SIZES VARY) MIN 18' RELA77VELY IMPERNOUS CLAY TYPICAL ELEV = 734.50 COMPACTED IN MlN PLACE UP TO 7J5.50 (REF PLA / 6 MIN .7.57 1 L ) 11 KFlLL W11H SAND 21N D GRADE 2WALL PIPE 77ED INTO RAP TOE DRAIN 2414 DEEPENED EDGE (TYPICAL ALL DOWNS7REAM EDGES) MIX LANDSCAPE DEFlNED GRASS SEED A r HALF THE SURFACE COVERAGE RATE OF THE EN77RE PATH WIDTH WITH THE VOLUME OF TOPSOIL NECESSARY TO FlLL THE VOIDS OF THE PAVERS EDGE RES7RAINr AND STAKE PER MANUFACTURER DETAIL TIIMA. NORMAL POOL ELEV (WELL SUPPLEMEN7ED) = 732.50 ELEV. a 729.25 —\ CLAY LIN CLAY LINER CONCRETE I—COMPAC7FD SUBGRADEJ 3' x 3' GABID BASKETS ELEV = 729.50 \ ELEV. = 723.50 BACKFlLL � LEVELING PAD y_y 7YPIGAL POND EDGE WALL 5E(.TInN SCALE: N.T.S. cale teague nail and perkins, inc 5horiz 5237 N. Riverside Drive, Suite 100 N/A Fort Worth, Texas 76137 v It 817.336.5773 ph 817.336.2813fx N/A www.tnpinc.com date t n TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 %— � w WOVEN 6EOIEX77LE FABRIC City of Fort Worth, Texas tnp prol0f GLP23338 Improvements for sheet HIGH SCHOOL #4 21 SWFMA EXHIBIT of POND DETAILS (3 OF 5) 26 GROUTED ROCK RIP RAP 2IN BELOW TOP OF WALL MIN SLOPED BACK TOWARD POND CON 7RAC77ON JOINT (MATCHED TO FLATwRK JOINTS) IIN BLOCK -OUT INSERTS ATTACHED TO FORMS ON EACH SIDE CONS 7RUC77ON JOINT w/ KEYWAY (TYPICAL AT MIDPOINT OF EACH NOSE AND CHANGES IN WALL TOP ELEVA770N) INCH CHAMFERED EDGES MATCHED TO FLATORK JOINT 10 INCH SAWCUT JOINT Wt7H SEALANT (ONE THIRD OF PAVEMENT DEP7H) (T)PICAL AT MIDPOINT OF EACH NOSE AND AT MIDPOINT OF WALL) -3' NO 3 BARS 0 15' O.C.B.W. SAWCUT CONIRAC770N JOINT (3) NO 3 PARALLEL BARS DEEPENED EDGE ALONG EN77RE POND SIDE FACE MCC 3 BARS 12' O.C. CON77N000S HORIZONTAL BARS EXTEND DOWN INTO DEEPENED EDGE (2) CON77N000S NO 3 BARS IN DEEPENED EDGE 14FT 8IN WEIR WALL CONTINUED � BEYOND TOP OF WALL=739.00 1 NO 3 BARS 012' O.C.B.W. NO J BAR KEY JOINT NO 3 BAR IN CONCRETE RIP H 5' GROUTED ROCK RIP RAP ROUGHENED SURFACE 5' VANES PER PION X 12IN OF LIME —� 1— 2r NN , - I - SLOPE STABILIZED SUBGRADE r • ' , 1 ` . S TABILIZA 77ON ` MAT 6IN CONCRETE FLATWORK 4 SM0077ILY 7RAN5177ONED TO SLOPE REINFORCED W/ NO 3 BARS 12' ADDtK Nd 3 B)9 Bq�l /j�/ IEIR TOP SPII_NAY SCALE: N.T.S. 51_OPI= PAVINr SCALE: N.7.5. teague nail and inc cale 5horiz perkins, 5237 N. Riverside Drive, Suite 100 N/A Fort Worth, Texas 76137 v :t It 817.336.5773 ph 817.336.2813fx date www.tnpinc.com TBPELS: ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 N07ES SEE POND CALCULA7701V SHEET FOR ALL WALL EL....._.._ • H= 3241N ADD 2 ADD17701VAL NO 3 PARALLEL BARS • H= 18IN TYPICAL WALL HEIGHT AS SHOWN (H=181NCH) • H= 3IN FORM AS MONOLITHIC CURB • H= DIN SM007HLY FILLET POND -SIDE EDGE WITH LARD RADIUS NO 3 BARS 015" a O.C.B.W. / � Y 6IN FLATWORK 2' DIA PVC WEEPS \� SPACED 10' O.C. r e fo• 10' y ° ate` i CRUSHED STONE *�. ENCLOSED BY i CON17N000S i RL 7ER FABRIC FOR LENGTH OF SLOPED e• _ PAVING. 4tnp City of Fort Worth, Texas tnp prol0f GLP23338 Improvements for sheet HIGH SCHOOL #4 22 SWFMA EXHIBIT of POND DETAILS (4 OF 5) 26 r�lnn�L .� 1 • rx.arFoa*ur q j.. N. . . ....� EROSION CONTROL INSTALLATION DETAILS ARMORM 75 MBrALIATON OETAh3 -Es SLOPE 5TABILIZRTION MAT scale Cit of Fort Worth, Texas League Hall and perkins, inc h,,;z GLP23338 ♦ Y tnp proieff 5237 N. Riverside Drive, Suite 100 N/A t Improvements for sheet Fort Worth, Texas 76137 ver, HIGH SCHOOL #4 817.336.5773 ph 817.336.2813 fx N/A 23 www.tnpinc.com date SWFMA EXHIBIT of TBPELS: ENGR F-230; SURV 10011600,10011601, 10194381 APR 2025 POND DETAILS (5 OF 5) 26 j STORM DRAIN %NU7- SEE CI.VK i � III �YAq q CqRVE TA6jLE j_PT-STA 12+14.54 WALL B.: CURVE DELTA RADIUS LENGTH TAN N 7033594.20 E 233581R27- C1 90 00'00" 50.00 78.54 50.00 750 730 A r 740 730 ELEVATION - RETAINING WALL B City of Fort Worth, Texas tnp project teague Hall and perkins, inc scale Y � orizGLP23338 5237 N. Riverside Drive, Suite 100 1 r'=40r Improvements for sheet Fort Worth, Texas 76137 verr HIGH SCHOOL #4 817.336.5773 ph 817.336.2813fx N.T.s. 25 --Mpinc.com dateKtn SWFMA EXHIBIT of TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 1 P RETAINING WALL B PLAN & PROFILE 26 740 730 ELEVATION - RETAINING WALL B City of Fort Worth, Texas tnp project teague Hall and perkins, inc scale Y � orizGLP23338 5237 N. Riverside Drive, Suite 100 1 r'=40r Improvements for sheet Fort Worth, Texas 76137 verr HIGH SCHOOL #4 817.336.5773 ph 817.336.2813fx N.T.s. 25 --Mpinc.com dateKtn SWFMA EXHIBIT of TBPELS; ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 1 P RETAINING WALL B PLAN & PROFILE 26 T • GENERAL STRUCTURAL NOTES: A ALL MODULAR BLOCK RETAINING WALLS SHALL BE GEOGRID REINFORCED STAYETERRA WALL SYSTEMS OR APPROI£D EQU& ARCH17EC7URAL FINISH SHALL BE COg401NA 1E0 KITH OWE? B. REFER 70 PROECT GEOTECHNICAL REPORT NO.. W233474, AND REWSONS THEREAFTER PREPARED BY UES PROFESSIONAL SOLUTIONS LLC FOR BORING, FILL MATERIAL, AND CONS7RUCTI0V REQUIREMENTS A COPY OF THE GEOTECHNICAL REPORT IS INaUDEO IN THE PROECT SPECTRCA77ON BOOK. C ALL WALL DESI6WS MUST BE IN CONFORMANCE NTH NCMA-09-ND EDIRON PUBUCAAGN D. ALLOWABLE BEARING PRESSURE FOR WALL FOUNDATIONS BEARING ON UNDISTURBED SOIL SHALL BE 20 KSF. E FREE DRAINING GRANULAR BACTKRLL SHOULD CONSIST OF A aEAN, NON -PLASTIC RELATIVELY HELL -GRADED GRANULAR SOIL CGWSIS77NG OF SAND, GRAIEI., OR A SAND AND GRA Y£L MIXTURE; NTH LESS THAN 5 PERCENT RNER THAN THE NO. 200 SIEVE SIZE 70 REDUCE SURFACE WATER SEEPAGE INTO THE FREE DRAINING BAC9KRLL, THE 70P 1-FT OF THE BACTKRLL SHOULD CONSIST OF ON- -7IF CXAY SOIL TN7H A PLASTICITY INDEX OF AT LEAST 25. COMPACTION SHALL BE ACCOMPLISHED USING HAND COMPACTION EQUIPMENT AND SHOULD BE COMPACTED TO A MINIMUM OF 95X AND A MAXIMUM OF 100% OF THE MAXIMUM DRY DENSITY DETERMINED BY THE STANDARD PROCTOR TEST AS7M 0698. HEAVY COMPACTION EQUIPMENT SHOULD NOT BE OPERATED NEAR THE WALLS F. WALL CONSTRUCTION SHALL BE IN CONFORMANCE 70 GEOMETRIC CONSTRAINTS PROWDED IN WALL PLAN AND PROFILE SHEETS G THE FREE DRAINING GRANULAR BACKFILL SHOULD BE SEPARATED FROM THE ADJACENT NAME SOILS USING A RLTER FABRIC (MIRAR 14M OR EQUIVALENT) 70 PREVENT INTRUSION OF NA77W SOILS INTO THE FREE DRAINING GRANULAR BACRTILL PLRFOIUTED PIE PIPE NEEP HOLES SHOULD BE P097IONED AT A DEPTH LOWER THAN THE BOTTOM/ ELEVATION OF THE WALL AND SHOULD ALSO BE #RAPPED NTH RLTER FABRIC (MHRAFT 140V, OR EQUIVALENT). H. ALL WALLS SHALL BE DESIGNED FOR THE FaLoWNG CRITERIA* FAC70R OF SAFETY FOR SLIDING AT BASE > 1.5 FAC70R OF SAFETY FOR OVERTURNING > 2.0 FACTOR OF SAFETY FOR BEARING 2 20 FAC70R OF SAFETY FOR EARTH RONF. PULLOUT 2 1.5 MATERIAL EFFECTIVE FRICTION EFFECTIVE COHESION MOIST UNR WEIGHT FACTOR OF SAFETY FOR CONNECTION 2 1.5 ANGLE (DEGREES) FACTOR OF SAFETY FOR aOBAL STABILITY 2 1.5 RETAINED SOIL 15 0 PSF 125 PCF BASE PRESSURE RESULTANT SHALL FALL NTHHN THE MIDDLE THIRD OF BASE INDTH FOUNDATION SOIL 15 0 PSF 125 PCF 1. ADD177ONAL LOADINGS REINFORCED SOIL: FREE DRAINING 35 0 PSF 125 PCF BUILDING LOADS N/A GRANULAR 9AC(FILL SURCHARGE 40 PSF CONS7RUCTION SEISMIC LOADING N/A J. HMROSTA77C DESIGN IS NOT CONSIDERED IN WALL DESIGN DUE TU SHORT TERM INUNDATION TIMES REZATIVELY IMPERWOUS HN-SIN CLAY SOILS AND POROUS BLOCK UN17S K. LENGTH OF GEOGRID (L) SHALL BE A MINIMUM OF 60% OF WALL HOGIHT (H) MEASURED HORIZONTALLY FROM THE BACK OF THE BLOCKS L BLOCK MUST BE PLACED ON A MIN/MUM 6' THICK LEVELING PAD cawszTNG OF LEAN CONCRETE OR %' CRUSHED STONE; CUSS 5 COMPACTED TO 95X OF STANDARD PROCTOR DENSITY. M. CONTRACTOR SHALL PROWDE MODULAR BLOC( SHOP DRATWNGS FOR RENEW AND APPROVAL PRIOR 70 INSTALLATIONS N. CCWTRACTO? STALL PROWDE DESIGN CALCULATIONS AND PLANS DESIGNED BY A TEXAS LICENSED PROFESSIONAL ENGINEER FOR RENEW AND APPROVAL PRIOR TO INITIATING CONSTRUCTION OF WALLS CONTRACTORS WALL DESIGN SHALL BE IN CONFORMANCE W7H GEOMETRIC CONSTRAINTS PROWDED CW WALL PLAN LAYW75 AND UPON THE FOLLONNG PARAMETERS• CONC. FLUME, SEE DET. E' FINISHED GRADE T78ACK =1' 8 Ml SAFETY RAIL NOT SHOWN 10' THICK LAYER OF �2' BATTER) IMPERWOUS CLAY MA7ERIAL o TOP OF WALL (SEE OWL) COMPACTED TO 95% _ �. Q - - : 7Kt l S70WETERRA STONEIERRA RILL BENCH STANDARD PROCTOR Z "zq FULL S70NE7VW MOCK NXIX AT AT 7A° COURSE u a� LOWER COURSES TOP O` WALL - - � 2 �i Q MOVE BLOCKS FORWARD DOW INS TALLA77ON START GEOGRID - - - _ _ - - - 3 O 70 ENGAGE 4/EAR KNOBS (FYl'?) ATfR B7 _ LOCK- _ _ _ - - _ - _ - 3 Z - - fREE BRAIN/TUG BACK AL TO EXTEND o SETBACK =1' r . - . .. LL = GEOTE kE FABRIC, —1 I L,-A.T.LEAS712' BEHINDALL 0 0 (1' BATTER) LAP GEOGRID 11 MIQIL-(rrP) N�I m BL8(YfS FORWARD DURING INSTALU RON TOfABR o Fes' STQVETERRA RAWdAR_8&XFZLL, 3 FULL BLOCK (TYP)� - -TYPICAL GRAVITY RETAINING WALL SECTION xo � _ .. _ . _ . _ _ "STRATAGRID SG600 B ZA _ _ _ GEOGRID SHALL HAVE CAE. MU 6i4ANULAR BACC l FRICTION CONNECTION WALL STATION _ - _ _ - _ _ I TEND �LL LENGTS AND H UNDERDRAIN POCKET SHALL BE 1=0" RLTER MATERIAL CONTROL LINf _ _ - _ - _ - _ - - BACK INTO REINFORCED WRAPPED NTH FILTER FABRIC MEERNG S NOTE f FINISHED - _ - - - - THE REQUIREMENTS OF T(DOT FILL ZONE (7YP) GRADE)� - - - _ - _ - _ DMS-610. TYPE 1. YIdL RETAINED SOIL BOTTOM Of - - - �--_-- -- WALL BOW I _ - - - - FOUNDA77ON SOIL (FILL) 4' PVC WEEPS AT 10' O.C. 1'-0' SO HARDWARE CLOTH o m HOI87., SLOPE 70 DRAIN CENTERED BEHIND OPENING 1'-0' I '-0 I1'-0" 12"X12" DRAIN POCKET W/ 4' PVC o it W WEEPS AT 10' O.C., SEE DET C'" LN SAFE SLOE DETERMINED BY UNDERDRAIN DETAIL COMPACTED 6' CRUSHED STONE AGG. CONTRACTOR OC Xk& xrs LEVELING PAD (SEE N07E TK) " OR APPROVED EQUAL CTIPICAL MODULAR BLOCK WALL SECTION COYVC. RUMS, SEE DET E srve w rs EXTEND GEOGRID ON70 /3 BARS 9 FACE FLANGE 18' O.C. FIN. -P_ RAILING POST GRADE BASE-SUBSTA77ON PRECAST CONCRETE 1/2' PREFORMED - _ E7ERRA' SYSTEM EXPANSION JUNT 3 - STONE7FRRA---- MATERIAL NTH SEALANT FULL BLOCK _ v (TIP)-- : j PAD NG STONEIERRA FULL BENCH (nP) LALIGN LONG AXIS (ROLL DIRECTION) OF TYPICAL FENCE DETAIL 3' CLR STRUCTURAL CEOGRID PERPENDICULAR TO OD 3 - 13 BARS (TTP) WALL FACE scuE xrs 0 EQ. SPA. C FLUME DETAIL Hrs C GEOGRID ORIENTA 77ON DETAIL SCALE srve Mrs City of Fort Worth, Texas tnp projeC( scale GLP23338 League Hall and perkins, Inc hPri� Y 5237 N. Riverside Drive, Suite 100 N/A Improvements for sheet Fort Worth, Texas 76137 NIA HIGH SCHOOL #4 817.336.5773 ph www.tn inc.co 6.2813 fx SWFMA EXHIBIT 26 www.fnpinc.com date t n MODULAR BLOCK RETAINING WALL off TBPELS: ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 DETAIL (1 OF 2) 26 i PLACE ADD177ONAL PIECES OF GEOGRID ' WHEN ANGLE EXCEEDS 20' OUTSIDE CURVES. 57ONE7ERRA MINIMUM RADIUS PER 7/M STANDARD GEOGRID7Fw MANUFAC711RER BLOCKS AT FACE �� WHERE NECESSARY C GEOGRID INSTALLATION ON CURVES SCALE N.T.S H H 4' 0' I 4'-0' iN 2'-0' `v 2'-0" `v I � � STANDARD BLOCK STANDARD BENCH HALF BLOCK HALF BENCH PLAN VIEW PLAN VIEW PLAN VIEW PLAN VIEW 2'-0' 2'-0' 2 O" I S'I 1'-6' N C4 N I N STANDARD BLOCK STANDARD BENCH HALF BLOCK HALF BENCH ELEVA77ON VIEW ELEVA77ON VIEW ELEVA77ON VIEW ELEVA77ON VIEW OH INDIVIDUAL BLOCK VIEWS SCALE, N.T.S City of Fort Worth, Texas inp 23338 teague nail and perkins, inc projeer Shape Y GLP23338 oriz 5237 N. Riverside Drive, Suite 100 N/A Improvements for sheet Fort Worth, Texas 76137 rt HIGH SCHOOL #4 817.336.5773 ph 817.336.2813 fx N/A 27 date SWFMA EXHIBIT www.tnpinc.com MODULAR BLOCK RETAINING WALL of TBPELS: ENGR F-230; SURV 10011600, 10011601, 10194381 APR 2025 DETAIL (2 OF 2) 26 0 i1 -64-4" 1--42'-l( .......... .... ........ .......... ..... ...... .......... ....... .. ........ .. .......... teaque nail and perkins, inc sale 5237 N. Riverside Drive, Suite 100 1 1. =80' Fort Worth, Texas 76137 vert 817.336.5773 ph 817.336.2813 fx www.tnpinc.com date TBIRELS: ENGR F-230; SURV 10011600,10011601, 10194381 APR 2025 M 010 (3) CHINQUAPIN OAK 6 RED OAK 0 (20) RED YUCCA — t City of Fort Worth, Texas Improvements for HIGH SCHOOL #4 n p SWFMA EXHIBIT POND LANDSCAPE E In, pr.,W GLP23338 sheet 28 of 26 Exhibit "C" CITY OF FORT WORTH STORMWATER FACILITY OPERATION AND MAINTENANCE PLAN FOR RETENTION / DETENTION The only responsibility the City of Fort Worth has in the operation and maintenance of this Facility is inspection. General Maintenance Procedures The structural and functional integrity of the Facility shall be maintained at all times, by removing and preventing drainage interference, obstructions, blockages, or other adverse effects into, through or out of the system. Periodic sediment and trash removal shall occur when the water level in the retention pond exceeds the additional storage volume above the standard water surface elevation by more than 10%. Sediment trash and debris shall be removed and the facility shall be returned to the original features, grades and water surface elevation shown on the approved exhibits attached to this Stormwater Facility Maintenance Agreement (SWFMA). In addition, corrective measures are required any time the additional storage volume above the standard water surface elevation of the retention portion of the facility does not drain within 72 hours of cessation of inflow. Detention facilities shall be mowed monthly between the months of April and October or anytime vegetation exceeds 12-inches in height. To prevent debris from entering and clogging the downstream storm sewer system a wire mesh screen or similar screening device shall be installed over the outlet until final acceptance. 4. PREVENTIVE MAINTENANCEANSPECTION Visual inspections of all components will be conducted every 6 months. A log shall be kept of maintenance actions, and inspections. The log should document the condition of the facilities primary components, mowing, silt, litter and debris removal dates. • Written maintenance and repair records shall be maintained by the party or parties signing the attached Agreement and shall be provided to the City upon request. SLOPE INSTALLATION '► ARMORMAX AND MAINTENANCE GUIDELINES Engineered Earth Armoring System Thank you for purchasing ARMORMAX® for Erosion Control or Slope Stability by Propex Operating Company, LLC (Propex). This document provides installation and maintenance guidelines for ARMORMAX used as slope armoring to improve earthen slope resiliency and slope stability. ARMORMAX provides permanent erosion protection of an earthen slope, promotes vegetation, and improves slope stability, consists of two components: • PYRAMAT® - High Performance Turf Reinforcement Mat (HPTRM) • Engineered Earth Anchor (Anchor) Temporary securing pins (pins) are used during installation to hold ARMORMAX in place while installing anchors. Pins also promote vegetation establishment keeping ARMORMAX in intimate contact with the soil. ARMORMAX is an Engineered Earth Armoring Solution TM with a unique design for each specific project. While Propex has made every effort to ensure general validity, this information should not be used for a specific application without independent professional examination and verification of its suitability, applicability, and accuracy. The information provided herein is for general information only, and is intended to present installation guidance. Project specific contract documents take precedence when pin and anchor placements are different than what is represented in this document. Depending upon the critical nature of the structure to be armored, work restrictions may be in place such as limiting work based on growing seasons, weather patterns, etc. Work should be performed under the provisions set forth for the specific project. Propex Engineering Services is available for support during installation to consult for solving constructability issues encountered in specific applications. Please feel free to contact our Engineering Serivices team at GeoEnaineering@Droaexglobal.com. BEFORE INSTALLATION BEGINS • Coordinate with a Propex Representative: A pre -construction meeting is suggested with the construction team and a representative from Propex. This meeting should be scheduled by the contractor with at least a two week notice. • Gather the Tools Needed: Tools that you will need to install ARMORMAX include a pair of industrial shears, tape measure, percussion hammer (sized appropriately for the anchors), ground rod driver compatible with the percussion hammer, drive steel compatible with the anchor, setting tool to set and load -lock the anchor, and wire/bolt cutters to cut the cable tendon of the anchor. If anchors will be load tested during construction, additional testing equipment may be necessary. Consult the "Anchor Load Test Manual" from Propex for further guidance. Available for purchase from Propex are drive steel, JackJaw® Setting Tools, wire cutters, and a gas powered anchor driver. • Determine how to Establish Vegetation: The method of vegetation establishment should be determined prior to the start of installation. • Different vegetation establishment methods require different orders of installation. Refer to VEGETATION ESTABLISHMENT for further guidance. INSTALLATION OF ARMORMAX ON SLOPES PREPARE THE SITE It is recommended during all stages of site preparation that disturbed soils remain unprotected for not more than a single day. Depending on project size this may require progressive site preparation during installation. 1. Grade and compact the area on the slope where ARMORMAX will be installed. The slope surface should be uniform and smooth, having all rocks, clods, vegetation or other objects removed so that during ARMORMAX LAYDOWN, ARMORMAX comes in direct, intimate contact with the slope surface. 2. Whether placing new fill or addressing a sloughed slope, appropriate placement and compaction is critical for the long term performance of the slope. In order to promote continuity of the slope and improve overall stability, any loose soil placed should be keyed into the existing slope and compacted in horizontal lifts per the engineer of record. To ensure compaction at the face of the slope, it is common practice to over -build the slope face, compact in lifts, and then regrade or trim the slope to the final grade. ARMORMAKPage 2of17 Engineered Earth Armoring System 3. Prepare the area to be armored with ARMORMAX by loosening the topsoil to promote better vegetation establishment. This may be accomplished with a rotary tiller on slopes 3:1 or flatter. For slopes greater than 3:1, prepare topsoil in a safe manner. COMPACTED BACKFILL ARMORMAX®, SEE NOTE III- III I(0.9 m3)MINtt (300 mm) 1 I ICI � III (300mm) ANCHOR ON HORIZONTAL SPACING PER ANCHOR/PIN SCHEDULE, SEE DETAIL 6, WITH PINS ON 12" (300 mm) CENTERS DETAIL 1: CREST OF SLOPE(COS)TRENCH Figure 1: Crest of Slope (COS) Trench 4. Excavate a Crest of Slope (COS) trench 12 in x 12 in (300 mm x 300 mm) minimum at a distance of 3 ft (900 mm) from the crest of the slope. (Figure 1). 5. Excavate a Toe of Slope JOS) trench 12 in x 12 in (300 mm x 300 mm) minimum at a minimum distance of 5 ft (1.5 m) from the toe of the slope. (Figure 2) 6. If seeding, refer to VEGETATION ESTABLISHMENT for additional considerations during site preparation. ARMORMAKPage 3of17 Engineered Earth Armoring System SEE DETAIL 3, TYPICAL COMPACTED ARMORMAX®, BACKFILL SEE NOTE 1 III III,,,III, Ilmu� (I.S miMINI I ANCHOR ON HORIZONTAL SPACING PER ANCHOR/PIN SCHEDULE, SEE DETAIL 6, WITH PINS ON 12" (300 mm)CENTERS DETAIL 2: TOE OF SLOPE (TOS) TRENCH Figure 2: Toe of Slope JOS) Trench I_1:7u[Q:7u/_A:NI_\'I1161TA0 1. Begin the ARMORMAX LAYDOWN process by starting with the downstream / downwind end of the site. To ensure proper anchoring of the overlapped areas the proceeding roll width must be laid out before the current roll width can be anchored with exception to the final roll width. For straight sections of a slope, ARMORMAX panel lengths should be long enough to construct COS and TOS trenches while also covering the surface of the slope being armored (Figure 12). Panel edges should rest approximately perpendicular to the slope center line. For best results, panels of ARMORMAX should be continuous and free from seams or roll end overlaps that are parallel to the centerline of the slope. Panel edge overlapping should follow a pattern of placing each proceeding panel's edge overtop the previous panel edge, shingling the panels in the direction of the water flow or prevailing wind. 2. Starting at the COS trench, lay ARMORMAX roll so that the roll ends points towards the crest of the slope (Figure 3), with a 3 inch (75 mm) overlap created at adjacent panel edge locations. Ensure that adjacent panel edges maintain a minimum 3 inch overlap during ARMORMAX LAYDOWN (Figure 8). TOS TRENCI ARMORMAX® ROLL 10 / /_ COS TRENCH Figure 3: Crest of Slope (COS) Trench Alignment 3. Secure ARMORMAX with pins and Secondary anchors in the COS trench. Pins should be made of steel with a 0.20 in (5 mm) minimum diameter, having a 1.5 in (38mm) diameter washer at the head, and a length between 12 and 24 in (300- 600 mm) with sufficient ground penetration to resist pullout (Figure 4). Longer pins may be required for looser soils. Heaver metal stakes may be required in rocky soils. Suggested placement of pins and Secondary anchors for the COS trench is ARMORMAKPage 4of17 Engineered Earth Armoring System along the bottom of the trench with pins on 12 in (300 mm) centers in between Secondary anchors on 4 ft (1.2 m) centers. Secondary anchors should also be installed on panel edge overlaps in the COS trench. 1.5" (38 mm) DIAMETER STEEL WASHER (5 mm) f0.20" DIAMETERSTEEL 12-24' SEE NOTE 2 FOR PIN DESCRIPTION DETAIL 7: PIN Figure 4: Securing Pin 4. Backfill and compact the COS trench in the location of the first ARMORMAX panel only (Figure 5). TOS TRENCI COS TRENCH Figure 5: Crest of Slope (COS) Trench Placement 5. Unroll the ARMORMAX roll on the slope surface in the area to be armored (Figure 6). Ensure that ARMORMAX has intimate contact with the ground and all irregular surfaces beneath ARMORMAX are removed. TOS TRENC ARMORMAX® ROLL COS TRENCH Figure 6: Placement of ARMORMAX across Slope 6. Secure ARMORMAX panels in place using pins, Primary anchors, and anchors across the slope surface according to the project's engineered design. Pin and anchor placement should reflect a staggered checkerboard pattern across the slope surface for best results (Figure 7 and Figure 8). • The leading edge of the first ARMORMAX panel should be secured on the Slope Armoring Edge (SAE) with pins on 12 in (300 mm) centers in between anchors on intervals based on the slope stability analysis. ARMORMAX® Page 5of17 Engineered Earth Armoring System • Roll edges shall be overlapped a minimum of 3 in (75 mm) with pins placed on 12 in (300 mm) centers in between anchors on intervals based on the slope stability analysis (Figure 8). • Roll ends shall be overlapped a minimum of 6 in (150 mm) with upstream / upwind panel on top. Secure roll end overlaps with two rows of pins staggered 6 in (150 mm) apart on 12 in (300 mm) centers and with one row of anchors on intervals based on the slope stability analysis (Figure 9) • For slope lengths greater than 45 ft (13.7 m), install simulated check slots. This method includes placing two rows of pins 12 in (300 mm) apart on 12 in (300 mm) centers and one row of anchors between the rows of pins on 4 ft (1.2 m) centers at 45 ft (13.7 m) maximum intervals or across the midpoint of the slope for slope lengths less than 60 ft (18.2 m) (Figure 10). • At the break in slope interface towards the TOS, it is suggested that anchors be installed on intervals based on the slope stability analysis (Figure 11). I I ARMORMAM SEE NOTE 1 I I VERTICAL PIN SPACING PER I I ANCHOR/PI N SCHEDULE 1----------1�- PIN, SEE DETAIL HORIZONTAL PIN SPACING PER ANCHOR/PIN SCHEDULE DETAIL 4: PIN PATTERN Figure 7: Example Pin Pattern FLOW OF WATER OR DIRECTION OF PREVAILING WIND HORIZONTAL PIN SPACING PER -PINS ON 12" (300 mm) CENTERS ANCHOR/PIN SCHEDULE PIN SPACING, ON ROLL EDGE OVERLAPS 3"OVERLAP MIN SEE DETAIL / BETWEEN ANCHORS 1 5 r Y14 r Y14 VERTICAL PIN SPACING PER I' F ANCHOR/PIN SCHEDULE U L G C. 1 I I I • I I I �. L ARMORMAX®, I I SEE NOTE 1 h C F o r 0 .. OFFSET ANCHOR AS SHOWN TO (D ANCHOR, SEE DETAIL CREATE A CHECKERBOARD PATTERN • PIN, SEE DETAIL 7 DETAIL S: ANCHOR/PIN PATTERN Figure 8: Example of Anchor Pattern - 0.5 Anchors/yd2 ARMORMAXO Page 6of17 Engineered Earth Armoring System TOP OF SLOPE I UP STREAM ARMORMAXO, SEE NOTE 1 FLOW OF WATER OR DIRECTION OF PREVAILING WIND F— 1� MAX L '1 I (300 mm) 6• MIN r T HORIZONTAL PIN SPACING (150 mm) PER ANCHOR/PIN SCHEDULE Nz 'A AAAA AA ROLL EDGE J rAPPING END BOTTOM OF SLOPE I DOWN STREAM NOTE: ARMORMAX SHOULD BE SHINGLED IN THE O ANCHOR, SEE DETAIL DIRECTION OF THE DOWN SLOPE AND FLOW . PIN, SEE DETAIL 7 DETAIL 8: OVERLAP AT ROLL END DETAIL Figure 9: Roll End Overlap ARMORMAXO, SEE NOTE 1 45MAX OR NEAR MIDPOINT OF SLOPE , • (13.5 m) HORIZONTAL PIN SPACING • 1'MAX �• PER ANCHOR/PIN SCHEDULE (300 mm) Q. .Q_ :n: O ANCHOR. SEE DETAIL V MAX Ji (650Mmm) • PIN, SEE DETAIL 7 (300 mm) DETAIL 9: SIMULATED CHECK SLOT DETAIL Figure 10: Simulated Check Slot ARMORMAX® Page 7of17 Engineered Earth Armoring System ARMORMAX®, ANCHOR ON HORIZONTAL SEE NOTE 1 SPACING, PER ANCHOR/PIN SCHEDULE, SEE DETAIL 6 DETAIL 3: BREAK IN SLOPE INTERFACE Figure 11: Break in Slope Interface 7. Secure ARMORMAX with pins and anchors in the TOS trench. Suggested placement of pins and anchors for the TOS trench is along the bottom of the trench with pins on 12 in (300 mm) centers in between anchors on 4 ft (1.2 m) centers (Figure 12). /- COS TRENCH TOS TRENCI Figure 12: Crest of Slope (COS) Trench and Toe of Slope JOS) Trench Complete 8. Backfill and compact the TOS trench. (Figure 12) 9. Continue to work down the length of the slope by repeating steps 1 through 8 overlapping each adjacent ARMORMAX panel by 3 inches (75 mm) (Figure 8). The last ARMORMAX panel should terminate on the Slope Armoring Edge (SAE) with pins on 12 in (300 mm) centers in between anchors on intervals based on the slope stability analysis. At a minimum, ARMORMAX panels should be pinned entirely across the slope surface, pins and anchors should be installed in the trenches, and the trenches should be backfilled and compacted at the end of each day to minimize rework in the case of a major rain event. Specific project conditions may warrant further evaluation of installation order for ease. An example elevation view (Figure 13) of a slope armored with ARMORMAX can be seen below for overall reference. Consult Propex Engineering Services at (800) 621-1273with any questions that you may have. ARMORMAX® Page 8of17 Engineered Earth Armoring System SEE DETAIL 1, TYPICAL ARMORMAMD / SEE NOTE SEE DETAIL 6, TYPICAL _ II II�III-III--I SEE DETAIL 10, _`-III-III ICI - II I TYPICAL , I --a SEE DETAIL 3, UI—III— III SEE DETAIL 2, TYPICAL -- -I I —I I I \ TYPICAL \ ' 1 1—I 1 a -I I �I =I I E I I u -I I I -I =1 I -III -III- I' --- -1 LFOREPINS ARE T SHOWN HE PURPOSE OOF CLARITY —III—III 1-III ELEVATION 1: INSTALLATION OF ARMORMAX ON A SLOPE Figure 13: Completed Slope Isometric View INSTALL ANCHORS The ARMORMAX anchor typically consists of an anchor head, a flexible cable tendon, and a load bearing plate. For quality control purposes and warranty claims, anchors should be delivered to the jobsite fully assembled and ready for installation. Anchors are to be installed in locations specified for the project, and are typically installed in conjunction with ARMORMAX LAYDOWN. There are several options available from Propex for different types of anchors. For optimal performance with the greatest risk reduction, it is important to select the proper anchor and perform the installation in accordance with the pattern designed for required resiliency and long term durability of the slope. Understanding the mechanics behind installing the anchor component of ARMORMAX will result in a quality ARMORMAX installation. TYPE B1 & B2 ANCHOR The installation of either Type B1 or Type B2 Anchor (Figure 14) is described below. The tools that you will need are a percussion hammer, a ground rod driver and drive steel compatible with the anchor and percussion hammer, a Jack -law setting tool, and wire cutters. ARMORMAX® Page 9of17 Engineered Earth Armoring System LOAD BEARING PLATE EMBEDMENT DE��A47_1 � SLOPE(PRPAREDESUBGRADE) ANCHOR/PIN SC_ ARMORMAX®,SEE NOTE 1 ANCHOR TENDON ANCHOR HEAD SEE NOTE 1.2 FOR ANCHOR / (LOAD -LOCKED POSITION) DESCRIPTION Figure 14: Anchor Detail 1. Use one piece drive steel or assemble segmental drive steel to the appropriate length in order to drive the anchor to the specified embedment depth. 2. Insert the tapered end of the drive steel into the hollow cavity of the anchor head. Position the anchor head/ drive steel tip above the ground at the drive location (Figure 15 and Figure 16). Figure 15: Insert Drive Steel into Anchor ARMORMAX® Page 10of17 Engineered Earth Armoring System Figure 16: Position Anchor Head / Drive Steel Tip 3. Using a percussion hammer, guide the drive steel into the ground perpendicular to the slope surface at a smooth pace. Continue driving until the desired embedment depth is reached (Figure 17). Figure 17: Drive Steel to Drive the Anchor into the Ground 4. Remove the drive steel from the ground. (Figure 18) Depending on soil conditions, this may require the use of a setting tool or leverage device. ARMORMAKPage 11of17 Engineered Earth Armoring System Figure 18: Remove Drive Steel from Ground 5. Slide the load bearing plate down the anchor tendon towards the slope surface using your hands (Figure 19). Figure 19: Slide Plate 6. Once the plate is close to the slope surface, place the JackJaw Setting Tool on the anchor plate and place the top of the anchor tendon into the grips, keeping the anchor tendon perpendicular to the slope surface (Figure 20). With gentle force, slowly start to press down on the JackJaw lever - towards the slope surface - causing the anchor tendon to start to move out of the ground (displace). During this step, the anchor head will turn in the ground - a process known as "anchor setting". The change in embedment depth to set a Type 131 Anchor can be up to 6 inches and up to 8 inches for Type B2 depending on soil conditions. When the anchor is set, there will be a noticeable change in the amount of force needed to displace the anchor any further. This is a good indication that the anchor head is now perpendicular to the anchor tendon and the anchor is ready to be load -locked. ARMORMAKPage 12of17 Engineered Earth Armoring System Figure 20: Use JackJaw Setting Tool to Set Anchor To load -lock an anchor, continue to apply tension to the anchor tendon using the JackJaw Setting Tool creating a slight depression on the slope surface. Visually, anchors across ARMORMAX will look similar to buttons across a mattress top when anchors have been properly load -locked. 8. Conduct anchor load tests when required for quality assurance during installation. Refer to the document entitled "Anchor Load Test Manual" by Propex for further details. 9. Once anchors have been load -locked, cut off the excess anchor tendon flush to the plate at the slope surface using wire cutters (Figure 21 and Figure 22). Figure 21: Trim Extra Cable Flush to Plate ARMORMAX® Page 13of17 Engineered Earth Armoring System Figure 22: Complete Anchor Installation VEGETATION ESTABLISHMENT Vegetation can be established with ARMORMAX by broadcast seeding, hydraulic seed application (hydroseeding), or sodding. Seed application rate, seed type, sod type, and irrigation rate should be selected based on local or site specific knowledge and time of year. For best results, consider having a site specific soil test performed to help determine what soil amendments, such as lime and fertilizer, need to be incorporated into the soil to promote healthy vegetation. Irrigate as necessary to establish and maintain vegetation until 75% of vegetation has established and has reached a height of 2 inches. Frequent, light irrigation will need to be applied to seeded areas if natural rain events have not occurred within two weeks of seeding. While watering seeded areas use a fine spray to prevent erosion of seeds or soil. Do not over irrigate. Proper irrigation guidance is provided under the Maintenance portion of this document. PROJECT SPECIFIC CONSIDERATIONS 1. For applications that require special transitions (i.e. connections to riprap, concrete, T-walls, etc.), refer to the project specific drawings or consult with Propex Engineering Services at (800) 621-1273. 2. A deeper terminal trench and/or hard armoring may be required when slopes have severe scour potential at the toe location. 3. For installing ARMORMAX panels around curved sections of a slope, trim panels at an angle so that no more than two layers of ARMORMAX overlap at any point in time. Additional pins and anchors may be needed to secure panel edges towards the toe of the slope depending upon the radius of the curved slope. Install pins or anchors as necessary to securely fasten ARMORMAX to the ground. 4. Allowable Vehicle Traffic: A. If using equipment on ARMORMAX, it should be of the rubber -tired type and should avoid sharp turns. Tracked equipment is not permitted to drive over the ARMORMAX without vegetation at any time. B. Avoid any traffic over ARMORMAX if loose or wet soil conditions exist. 5. Disturbed areas should be reseeded. If ruts or depressions develop for any reason, rework soil until smooth and reseed such areas. ARMORMAKPage 14of17 Engineered Earth Armoring System SHORT-TERM AND LONG-TERM MAINTENANCE OF ARMORMAX The purpose of this section is to provide some general guidelines for performing short-term and long-term maintenance of ARMORMAX with respect to maintaining vegetation reinforced with ARMORMAX, and patching of ARMORMAX (in the event it needs to be removed or replaced). These procedures are to be considered minimum guidelines for proper maintenance, and further maintenance techniques may be appropriate considering local practices and procedures. ARMORMAX PROTECTED SLOPES For ARMORMAX to be most effective, it is important to ensure that it is properly maintained both during construction and after construction. Identifying trouble areas is easy with ARMORMAX, and it can make identifying potential threats much simpler and manageable. Look for areas with sparse, dying, or no vegetation as these are obvious signs that ARMORMAX is losing intimate contact with the slope surface. If loss of ground surface occurs, ARMORMAX will need to be removed and reinstalled as described in PATCHING AND REPAIRS section after the eroded area is backfilled with compacted soil that is similar to material of the slope. After ARMORMAX is reinstalled, re-establish vegetation on the newly installed ARMORMAX and disturbed areas. Monitor the sites to determine if frequent watering may be required to establish vegetation. To minimize exposure to unwanted maintenance and repair, ARMORMAX armored slopes should be free of unauthorized vehicular traffic. Routine maintenance and slope inspections should be performed with rubber tired vehicles. Tracked equipment such as skid steers, excavators, or dozers should only be allowed to traffic over ARMORMAX in times of emergency after vegetation establishment is complete. Failure to control unauthorized traffic can result in ARMORMAX being damaged resulting in erosion below ARMORMAX during storm events. In addition, routine mowing maintenance should be used to keep the protected area free of unwanted brush, saplings, and trees. Selective herbicides that target only the unwanted plants can be used as long as the vegetation established with ARMORMAX is not impaired. Failure to control the sapling and tree growth can result in the trees being uprooted during a flood. MAINTAINING VEGETATION Good vegetative cover will ensure maximum performance of ARMORMAX. Vegetative cover care starts before a project is complete and is ongoing until all ARMORMAX is installed. Vegetative cover should be given every opportunity to grow and establish well. This will require that a contractor periodically fertilize, water, and mow the grasses as needed until a project is complete in the short-term, with the owner of the slope fulfilling the maintenance of the slope in a similar fashion for the long- term. For the entire lifecycle of ARMORMAX, every effort must be made to prevent unauthorized encroachments, grazing, vehicle traffic, the misuse of chemicals, or burning during inappropriate seasons. 1. After the installation of vegetation is complete, immediately water and soak the entire area using a fine spray to prevent erosion and loss of seeds. A suggested amount of water is identified below. Prior to installation if using sod, the sod pads in storage should be kept moist at all times and not stored for more than 24 hours from site arrival to installation. Warmer weather will necessitate more frequent applications than listed below. A. For each reach/segment of installed vegetation, watering shall be conducted immediately after each installation or the day's work. B. For initial vegetation establishment, water vegetation in a manner consistent with best practices for vegetation type and location. C. Establish a watering schedule and follow until vegetation is well established and will thrive in the absence of manual watering. D. Avoid excessive application of water, so that surface runoff does not occur. Runoff should be prohibited. However, additional watering may be required for repaired or damaged areas. 2. Fertilizer should be applied as needed to address any nutrient deficiencies revealed in soil testing. ARMORMAKPage 15of17 Engineered Earth Armoring System 3. Implement best practices for mowing over ARMORMAX. While ARMORMAX is designed to withstand non -hydraulic stresses such as mowing, there are procedures to minimize exposure to unwanted damage. A. Immediately after installation, signage and post shall be installed stating that "Vehicles and Pedestrians are Prohibited from Access" on the slopes and the newly installed vegetation. Signage shall be posted every 1,500 lineal feet. B. Vegetated areas should be mowed to a height no less than 6 inches and no greater than 12 inches from natural ground after a period of 60 days of growth. The excessive grass clippings created from mowing shall be evenly spread on the slope section outside of the armored area. Periodic and final grass mowing should be performed until final inspection and acceptance of slope work. Monitor the vegetated areas throughout winter months and generate reports as needed, noting any issues that should be addressed. Minimum mowing heights will depend on the vegetation density and should be as follows: i. 6" with 0 - 30% vegetation establishment ii. 4" with 30 - 70% vegetation establishment iii. 3" with 70 - 100% vegetation establishment C. To prevent damage to the newly established vegetation, the mowing tractor should be fitted with 3-rib agriculture tires. Note that tractors with 8-foot flail mowers provide best results. Tractors with 15-foot brush hogs should avoid sharp turns up the slope to prevent damage to vegetation. D. Mowing should not take place for a minimum of 48 hours after a rainfall event of 2 inches or more to minimize the potential for rutting and/or damage to the slope surface. Maintenance mowing of the slope should be done on a consistent basis to prevent vegetation growing to more than 3 feet in height. This will minimize thatch thickness and potential damage to ARMORMAX. If turn -around pads are present, operate mowing equipment utilizing the turn -around pads to the fullest extent. The mowing blade height over ARMORMAX should be a minimum of 8 inches. However, should vegetation grow to more than 3 feet in height, the mowing blade height for the condition should be a minimum of 12 inches. 4. Some special circumstances may exist. When mowing the crown of a slope with a crown or crest equal to or exceeding 20%, it should be mowed with an articulating arm mower to minimize the potential for the mower blades to catch ARMORMAX at the slope surface. The articulating arm mower should be level on the surface with the articulating arm extending over the crown. Pay close attention to areas where the slope changes. The mower blades should be set at a minimum height of 8 inches. If ARMORMAX is damaged by the mowing blades at any time, mowing should stop immediately and further direction should be obtained to continue activity. Repair the damaged area as described in the PATCHING AND REPAIRS section below. 5. ARMORMAX protected slopes are not as susceptible to animal burrowing due the tenacity of the ARMORMAX; however, inspections to detect the presence of burrowing animal activity are generally most effective immediately after the slope has been mowed. Animal burrows that are identified should be thoroughly excavated and inspected, backfilled with compacted soil that is similar to material of the slope, and vegetation re-established. This will avoid the possibility of water piping through unfilled portions of the burrows. Should ARMORMAX be damaged, it is to be repaired as described PATCHING AND REPAIRS section below. PATCHING AND REPAIRS ARMORMAX may require localized repair at times. For emergency repairs, an adequate supply of ARMORMAX should be maintained in inventory with the necessary tools to install. This will allow for a timely, initial repair of the system. 1. In order to identify areas in need of repair, the site should be patrolled immediately after mowing and after rain events of 2 inches or more. When patrolling look for areas of sparse vegetation, exposed edges of ARMORMAX, and areas where direct contact between ARMORMAX and the slope surface is compromised. ARMORMAX should be rated as Acceptable, Minimally Acceptable, or Unacceptable during inspection. ARMORMAX® Page 16of17 Engineered Earth Armoring System A. Acceptable (A) - The rated area is in satisfactory, acceptable condition, and will function as designed and intended during the rain event. ARMORMAX has no exposed edges, is installed tightly by maintaining direct contact to the slope surface with no rilling beneath, and has over 90% vegetation cover. There is no noticeable damage present. B. Minimally Acceptable (M) - The rated area has a minor deficiency that needs to be corrected. The minor deficiency will not seriously impair the functioning of the area during the next rain event; however, the overall reliability of the project will be lowered because of the minor deficiency. ARMORMAX has 75% vegetation cover with un-vegetated patches as large as one square yard. Edges of ARMORMAX are exposed with noticeable damage. Minimal erosion has occurred underneath ARMORMAX. C. Unacceptable (U) - The rated area is unsatisfactory. The deficiency is so serious that the area will not adequately function in the next rain event. ARMORMAX has been physically torn, ripped, or lifted from the slope surface. Less than 75% vegetation cover is present with un-vegetated patches being greater than 1 square yard, and there is evidence that erosion is occurring beneath ARMORMAX. 2. Repair any raised or exposed edges of ARMORMAX by driving existing and additional pins or anchors along the edges as necessary to securely fasten to the ground. Inspect areas where the vegetation is not growing on top of ARMORMAX. Many times this is an indicator that ARMORMAX has lost contact with the ground beneath. Check for voids beneath ARMORMAX and fill any holes, gullies, etc. with compacted fill material if possible. Replace ARMORMAX as described below. 3. To repair ARMORMAX, cut out and remove damaged areas in a square configuration a minimum size of 2 ft by 2 ft. Remove all vegetation and debris atop of ARMORMAX. Loosen the top 1 to 2 in of soil in the patch area then seed. The subgrade of area to be patched shall be prepared to be smooth and uniform and transition smoothly into the in -situ area. Cut a square ARMORMAX patch a minimum of 12 in greater than the damaged area for all four sides of the patch. Overlap the patch area in all directions a minimum of 12 in. The patch overlaps shall be tucked under the existing damaged ARMORMAX material (Figure 23 and Figure 24). FLOW 12" MINIMUM 12" MINIMUM 6"MINIMUM 6"MINIMUM 2' MINIMUM TmNp ===1 I I -I I1I I I -I I --I I II -I I -I -I I II -I 1-111-1 I- -1 I I I_1 1 ,2"'PW- III I I I_1 I I-- III -III-III 11-11 �- -1-I -I 1- 1=1 _-I I-ANCHOR__-III-1 1-1 EXISTING ARMORMAX —1 —�—� EXISTING ARMORMAX - ARMORMAXPATCH_ III -III III III III �- Figure 23: ARMORMAX Patch Cross Section ARMORMAX® Page 17of17 Engineered Earth Armoring System 2 FT MAXIMUM /CENTER ON CENTER/ i i i 2 FT MAXIMUM CENTER ON CENTER '- 6 IN MAXIMUM/ CENTER ON CENTER AREA OF DAMAGED ARMORMAX 2'MINIMUM 6 IN MAXIMUM CENTER ON CENTER / �MU 12 MINIMUM �,12"MINIMUM / ® TYPE 61 ANCHOR • PIN Figure 24: ARMORMAX Patch Plan View 4. Install anchors on 2 ft (600 mm) (max) centers, and pins on 6 in (150 mm) (max) centers. For larger areas of damage, anchors should be installed to match existing anchor pattern and type. Once ARMORMAX is in place, vegetate per project specifications. SUMMARY Maintenance should consist of watering and weeding, repair of all erosion, and any re -seeding as necessary to establish a uniform stand of vegetation during construction and beyond. A minimum of 70% of the armored area should be covered with no bare or dead spots greater than 10 ft2 (1 m2). Establishing vegetation should not be mowed prior to 70% vegetative density and a minimum grass growth of 4 in (100 mm). Throughout the duration of the project, the contractor should be responsible for mowing to facilitate growth and should not let the vegetation in the armored areas exceed 18 in (450 mm). In addition, the Contractor should water all grassed areas as often as necessary to establish satisfactory growth and to maintain its growth throughout the duration of the project. After the project is complete, it is the responsibility of the Owner to maintain and upkeep all ARMORMAX installed areas for long term performance and best results as described herein for superior slope armoring. FORT WO RT H Fort Worth °CS Stormwater Management " EXHIBIT D" STORMWATER RETENTION/DETENTION FACILITY MAINTENANCE CHECKLIST FREQUENT INSPECTION Inspection Item: Date: Repairs Required: Repairs Made: Notes: Remove: Trash and Debris Remove: Grass Clippings, Leaves, Etc. MINOR INSPECTION: Inspection Item: Date: Repairs Required: Repairs Made: Notes: Condition of Outfall Structure Amount of Silt in Outfall Structure Amount of Ponded Water the Water Pool Elevation in Facility MAJOR INSPECTION: Inspection Item: Date: Repairs Required: Repairs Made: Notes: Type / Condition of Outfall Structure Size and Condition of Outfall Pipe Evidence of Roots Infiltrating the Facility Evidence of subsidence around facility