Loading...
HomeMy WebLinkAbout065993 - Construction-Related - Contract - Fort Worth ISD (FWISD)Date Received: 10/5/2026 Time Received: 2:38 p.m. Permit No.: SWFMA-26-0045 City Secretary No.: 65993 UNDERGROUND STORMWATER FACILITY MAINTENANCE AGREEMENT THIS AGREEMENT, made and entered into this 3rd day of Octob 2026, by and between, Fort Worth Independent School District, a political subdivision of the State of Texas, and a legally constituted independent school district located in Tarrant County, Texas, acting by and through Kellie Spencer, its duly authorized Deputy Superintendent, hereinafter referred to as "Landowner", and the City of Fort Worth, hereinafter referred to as "City". WITNESSETH WHEREAS, the Landowner is the owner of certain real property described as being 21,368 square foot (0.4905) tract of land situated in Thomas B. Taylor Survey, Abstract No. 1539, City of Fort Worth, Tarrant County, Texas, being a portion of Tract 4, St. Augustine Addition, an addition to the City of Fort Worth, Texas according to the plat recorded in Volume 388-U, Page 82, Plat Records, Tarrant County Texas, hereinafter called the "Property"; WHEREAS, the Landowner is proceeding to build on and develop the Property according to the Site Plan/Subdivision Plan known as FWISD McLean MS hereinafter called the "Plan", which is expressly made a part hereof, as approved or to be approved by the City and the Landowner provides for management of storm water within the confines of the Property; and; WHEREAS, the City and the Landowner, and their successors and assigns, agree that the health, safety and welfare of the residents of the City of Fort Worth, Texas require OFFICIAL RECORD CITY SECRETARY FT. WORTH, TX UNDERGROUND STORMWATER FACILITY MAINTENANCE AGREEMENT Revised that all on -site Underground Stormwater Management Facilities be constructed and maintained on a portion of the Property; and WHEREAS, the City requires that on -site Underground Stormwater Management Facilities ("Facility") as shown on the Plan be constructed and adequately maintained by the Landowner, its successors and assigns, the location and dimensions of which is shown and more particularly described by metes and bounds in the attached Exhibit "A" ("Facility Property"); and NOW, THEREFORE, in consideration of the foregoing premises, the mutual covenants contained herein, and the following terms and conditions, the parties hereto agree as follows: 1. The Landowner, its successors and assigns, shall adequately construct and maintain the on -site Underground Stormwater Management Facility ("Facility") at no expense to the City of Fort Worth in accordance with the design specifications for the Facility, attached as Exhibit "B", and the current standards then in force and effect in the City of Fort Worth and with the Operations and Maintenance Plan attached to this Agreement as Exhibit "C". The Underground Stormwater Management Facility shall include all storage chambers, manifolds, overflow inlets, outfall pipes or other conveyances built to convey, detained and mitigate the stormwater from the facility to a final discharge location per city requirements, as well as all erosion protection, structures, improvements, and vegetation provided to control the quantity and quality of the Stormwater. Adequate maintenance is herein defined as good working conditions so that these facilities are performing their design functions. The Stormwater Underground Detention Facility Maintenance Checklists, attached to this Agreement as Exhibit "D", are to be used to establish what good working condition is acceptable to the City. 2. The Landowner, its successors and assigns, shall inspect the underground facility and submit the inspection checklist attached as Exhibit "D" to the City annually. The purpose of this inspection is to ensure the safe and proper functioning of the UNDERGROUND STORMWATER FACILITY MAINTENANCE AGREEMENT 2 revised Facility. The inspection shall cover the entire Facility, storage chambers, manifolds, overflow inlets, outfall pipes or other conveyances, etc. Components of the Facility, which need maintenance or replacement to perform their design function, shall be noted in the inspection report along with the corrective actions to be taken. 3. The Landowner, its successors and assigns, hereby grant permission to the City, its authorized agents and employees, to enter upon the Property and to inspect the Facility Property whenever the City deems necessary. The purpose of inspection is to follow-up on reported deficiencies and/or to respond to citizen complaints. The City shall provide the Landowner, its successors and assigns, copies of the inspection findings and a directive to commence with reasonable and necessary repairs. 4. In the event the Landowner, its successors and assigns, fail to maintain the Facility in good working condition as specified herein, the City, its authorized agents and employees, may enter upon the Facility Property and take whatever steps necessary to correct deficiencies identified in the inspection report and to charge the costs of such repairs to the Landowner, its successors and assigns. It is expressly understood and agreed that the City is under no obligation to routinely maintain or repair said Facility, and in no event shall this Agreement be construed to impose any such obligation on the City, such obligation is Landowner's. 5. The Landowner, its successors and assigns, will perform the work necessary to keep the Facility in good working order as appropriate. In the event the City pursuant to this Agreement, performs work of any nature, or expends any funds in performance of said work for labor, use of equipment, supplies, materials, and the like, the Landowner, its successors and assigns, shall reimburse the City upon demand, within thirty (30) days of receipt thereof for all actual costs incurred by the City hereunder. 6. This Agreement imposes no liability of any kind whatsoever on the City. 7. Landowner covenants and agrees that no habitable building shall be erected within the boundaries of the Property in which the Facility is located as outlined UNDERGROUND STORMWATER FACILITY MAINTENANCE AGREEMENT 3 Revised on Exhibit "A" but this paragraph shall not preclude construction of other improvements within the boundaries of the Property in which the Facility is located, which do not impede the function of the facility drainage. Landowner covenants and agrees' that no habitable building shall be erected on the above property. No habitable building will be abutting such boundaries of the Property in which the Facility is located, in which the finished floor elevation is less than two feet above the maximum capacity of water in the underground facility which would occur during a 100 -year frequency flood. 8. This Agreement shall be recorded among the land records of Tarrant County, Texas, shall constitute a covenant running with the land, and shall be binding on the Landowner, its administrators, executors, assigns, heirs and any other successors in interests, including any property owner's association. SIGNATURES ON FOLLOWING PAGE UNDERGROUND STORMWATER FACILITY MAINTENANCE AGREEMENT 4 Revised Executed this 3rd day of October CITY OF FORT WORTH Jesica McEachern Assistant City Manager City of Fort Worth Date: 10/03/2026 Approved as to Form and Legality: Al ke vl'n 14n'(e -s, /1 M. Kevin Anders. II (Sep 22, 2026 10:1308 CDT) M. Kevin Anders, II Assistant City Attorney II City Attorney's Office Date: 09/22/2026 O 0 onn p� �FORt�00 ATTEST: p°8 oo=d 0d4n t°nE°Xop°5av Jannette S. Goodall City Secretary Date: 10/05/2026 2026. LANDOWNER Fort Worth Independent School District By: K llie Spencer Its: Deputy Superintendent Date: 8/27/2026 Contract Compliance Manager: By signing, I acknowledge that I am the person responsible for the monitoring and administration of this contract, including ensuring all performance and reporting require s. Kandice Merrick Planning Manager Date: 09/22/2026 OFFICIAL RECORD CITY SECRETARY FT. WORTH, TX UNDERGROUND STORMWATER FACILITY MAINTENANCE AGREEMENT Revised STATE OF TEXAS § COUNTY OF TARRANT § October 3, 2026 This instrument was acknowledged before me on by Jesica McEachern, Assistant City Manager of the City of Fort Worth, on behalf of the City of Fort Worth. , f; _t ,R P` Po XATHLEEH BRADFORD r���, Notary Public Notary Public, State of Texas STATE OF TEXAS '� Notary ID, 12197197 of MY Comm, Ex . Apr. T2, 2027 LANDOWNER STATE OF TEXAS COUNTY OF TARRANT M BEFORE ME, the undersigned authority, a Notary Public in and for the State of on this day personally appeared Kellie Spencer (name), Deputy Superintendent of District Operations_ (title), known to me to be the person whose name is subscribed to the foregoing instrument, and acknowledged to me that he/she executed the same for the purposes and consideration therein expressed, as the act and deed of_Fort Worth Independent School District_ (entity), a _Independent School District (entity type) and in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE this 27th day of August 2026. Nota Public, Stat of Te a �,�� ,�;#,� LETICIA tA1NG ARRIAL3 `+�r `�' MY COMMISSION EXPIRES +>`,E'`�f1�c OCTOBER 20, 2027 %''; o ;;� NOTARY ID:124719386 UNDERGROUND STORMWATER FACILITY MAINTENANCE AGREEMENT 6 Revised EXHIBIT "A" LEGAL DESCRIPTION UNDERGROUND STORMWATER FACILITY MAINTENANCE AGREEMENT Revised DRAINAGE EASEMENT TRACT 4 ST. AUGUSTINE ADDITION THOMAS B. TAYLOR SURVEY, ABSTRACT NO. 1539 CITY OF FORT WORTH, TARRANT COUNTY, TEXAS Being a 21,368 square foot (0.4905 acre) tract of land situated in the Thomas B. Taylor Survey, Abstract No. 1539, City of Fort Worth, Tarrant County, Texas, being a portion of Tract 4, St. Augustine Addition, an addition to the City of Fort Worth, Texas, according to the plat recorded in Volume 388-U, Page 82, Plat Records, Tarrant County, Texas, being a portion of a tract of land occupied by Fort Worth Independent School District (no recording information found), and being more particularly described as follows: COMMENCING at the intersection of the west right-of-way line of Stadium Drive (a 60 foot right-of-way) and the south right-of-way line of Dryden Road (a variable width right-of-way), for the northeast corner of said Tract 4, from which a found chiseled "X" in concrete bears North 89°51'56" East, a distance of 59.93 feet; THENCE along the common line between said Dryden Road and said Tract 4, the following bearings and distances: South 89°30'46" West, a distance of 125.05 feet to a point; South 88°21'46" West, a distance of 483.65 feet to a point, from which the northwest corner of said Tract 4 bears South 88°21'46, a distance of 148.95 feet; THENCE over and across said Tract 4, the following bearings and distances: South 00°15'22" East, a distance of 11.84 feet to a 1/2" iron rod with yellow plastic cap stamped "RLG INC" set for the POINT OF BEGINNING; South 00°15'22" East, a distance of 177.55 feet to a 1/2" iron rod with yellow plastic cap stamped "RLG INC" set for corner, from which a found 5/8" iron rod in the south line of said Tract 4, for the northwest corner of Boyd Avenue (a 50 foot right-of-way) and the northeast corner of Lot 5, Block 10, Windsor Place Addition, an addition to the City of Fort Worth, Texas, according to the plat recorded in Volume 388-C, Page 53, Plat Records, Tarrant County, Texas bears South 01°55'09" West, a distance of 572.88 feet; South 89°44'38" West, a distance of 120.35 feet to a 1/2" iron rod with yellow plastic cap stamped "RLG INC" set for corner; North 00°15'22" West, a distance of 177.55 feet to a 1/2" iron rod with yellow plastic cap stamped "RLG INC" set for corner; North 89°44'38" East, a distance of 120.35 feet to the POINT OF BEGINNING, containing 21,368 square feet or 0.4905 acres of land, more or less. BASIS OF BEARINGS: State Plane Coordinate System, North Texas Central Zone 4202, North American Datum 1983, Adjustment Realization 2011. BR1gN R. W�ypE 6098' ..... 9��FFSSIoN. �` Brian R. Wade R.P.L.S. No. 6098 Date: 07/08/2026 Sheet I of 5 29,004X DR YDEN ROAD PO/NT OF (VARIABLE WIDTH PUBLIC RIGHT- OF- WA Y) e COMMENCING LINE TABLE LINE BEARING LENGTH Li N89 51 '56 "E 59.93' L2 S0075'22"E 11.84' Li S00 75'22 "E 177.55' L4 589 44'38"W 120.35' L5 N00 75'22 "W 17755' L6 N89 44'38"E 120.35' **NO TE: ALL CORNERS ARE WITH YELLOW PLASTIC CAP INC" SET UNLESS OTHERWISE SHEET 2 FOR EASEMENT TABLE, AND LEGEND** POINT OF BEGINNING DRAINAGE EASEMENT 21,368 SQ. FT 0.4905 ACRES TRACT 4 ST AUGUSTINE ADDITION VOL. 388-U, PG. 82 P.R. T.C. T. FORT WORTH INDEPENDENT SCHOOL DISTRICT (NO RECORDING INFORMA TION FOUND) iiII II II ii Q 0. EASEMENT 0 VER VIEW NOT TO SCALE 1/2" IRON ROD STAMPED 'RLG SPECIFIED. SEE OVERVIEW, LINE BASIS OF BEARINGS.• STA TE PLANE COORDINA TE SYSTEM, NORTH TEXAS CENTRAL ZONE 4202, NORTH AMERICAN DA TUM OF 1983, ADJUSTMENT REALIZATION 2011. CONTROLLING MONUMENTS: AS SHOWN. RAYMOND L. GOODSON JR., INC. 12001 N. CENTRAL EXPY, STE 300 DALLAS, TX. 75243 214-739-8100 rlg@rlginc. corn SCALE TEXAS PE REG #F-493 TBPELS REG #100341-00 JOB A LEGEND jr XF Cos (aw) P.R. T.G T. D.R.T.GT. QP.R.T.GT. INST. Na ►tiac.. pa PFC uww ........ PROPERTY LINE ........ EASEMENT LINE ........ 1/2' IRON ROD M7N YELLOW PLAS77C CAP STAMPED _ " FOUND ........ 1/2IRON ROD FOUND ........ CHISELED 'X' FOUND ........ 1' COPPER DISK STAMPED RLG INC' SET ........ CONTROLLING MONUMENT ........ PLAT RECORDS TARRANT COUNTY, 7EXAS ........ DEED RECORDS, TARRANT COUNTY, TEXAS ........ OFFICIAL PUBLIC RECORDS, TARRANT COUNTY, TEXAS ........ /NS7RUMENT NUMBER ........ 1'7LUME, PAGE ........ POINT FOR CORNER ........ UNABLE 70 MONUMENT DRAINAGE EASEMENT TRACT 4 ST. AUGUSTINE ADDITION THOMAS B. TAYLOR SURVEY, ABSTRACT NO. 1539 CITY OF FORT WORTH, TARRANT COUNTY, TEXAS BLOCK? SAINT AUGUSTINE ADDITION I DR YDEN ROAD (VARIABLE WIDTH PUBLIC RIGHT -OF -WA Y) zl S8821'46"W S8930'46"W il 483.65' 125.05' iI FORT WORTH INDEPENDENT SCHOOL DISTRICT I (NO RECORDING INFORMA TION FOUND) TRACT 4 BLOCK 2-R-1 SAINT AUGUSTINE ADDITION INST NO. D221377533 O.P.R. TC. T POINT OF �PFC I XF (CM) Li ST AUGUSTINE ADDITION VOL. 388-U, PG. 82 I Q v P.R.T.C.I Q m APPR0X/MA TE (n L0CA TI0N OF SUR VEY ABSTRACT LINE **NOTE. ALL CORNERS ARE 1/2" IRON ROD WITH YELLOW PLASTIC CAP STAMPED "RLG INC" SET, UNLESS OTHERWISE SPECIFIED. SEE SHEET 2 FOR EASEMENT OVER VIEW, LINE TABLE & CURVE TABLE, AND LEGEND ** BASIS OF BEARINGS: STA TE PLANE COORDINA TE SYSTEM, NORTH TEXAS CENTRAL ZONE 4202, NORTH AMERICAN DA TUM OF 1983, ADJUSTMENT REALIZA TION 2011. CONTROLLING MONUMENTS: AS SHOWN. RAYMOND L. GOODSON JR., INC. 12001 N. CENTRAL EXPY, STE 300 DALLAS, TX. 75243 214-739-8100 rig Orlginc. corn SC/ TEXAS PE REG #F-493 TBPELS REG #100341-00 JO 0 25 50 100 (FEET) 1 inch = 50 ft. DRAINAGE EASEMENT TRACT 4 ST. A UG US TINE ADDITION THOMAS B. TAYLOR SURVEY, ABSTRACT NO. 1539 CITY OF FORT WORTH, TARRANT COUNTY, TEXAS _______I 0 25 50 100 LOT 11, BLOCK 19 (FEET) LOT 10, BLOCK 19 WESTCLIFF ADDITION WESTCLIFF ADDITION VOL. 388—C, PG. 50 1 inch = 50 ft. VOL. 388—C, PG. 47 P.R. T.C. I P.R. T.C. I DR YDEN ROAD (VARIABLE WIDTH PUBLIC RIGHT-OF-WAY) PFC 1" /RF(BENT)(CM), BEARS S50 36'20 "E, 0.51' S88 21 '46 "W 148.95' 5882146W 46 "W 483.65' BUILDING LINE 28.5 i L6 •• L2 l/OL. 388-G PG. 47, P.R. T C.T. POINT OF i I BEGINNING j CENTERLINE OF STORM LOT 1, BLOCK 20 , SEWER EASEMENT WESTCLIFF ADDITION = . i VOL. 2752, PG. 602 VOL. 388-C, PG. 47 i .i D.R. T.C. T P.R. T C. T. i CENTERLINE OF STORM LOT 2 DRAINAGE SEWER EASEMENT VOL. 3121, PG. 537 UTILITY EASEMENT - EASEMENT 21, 368 SQ. FT h D.R. T.C. T. VOL. 388-C, PG. 47 i v- P.R. T.C T. 0.4905 ACRES '-I FORT WORTH INDEPENDENT SCHOOL DISTRICT (NO RECORDING LOT 3 = - i INFORMA TION FOUND) TRACT 4 i 28,3' •• •• i ST AUGUSTINE ADDITION VOL. 388-U, PG. 82 **NOTE: ALL CORNERS ARE L4 P.R. T.C. T 1/2" IRON ROD WITH YELLOW I PLASTIC CAP STAMPED "RLG INC" SET, UNLESS OTHERWISE I o SPECIFIED. SEE SHEET 2 FOR EASEMENT OVERVIEW, LINE ^i TABLE & CURVE TABLE, AND LEGEND** L\ BASIS OF BEARINGBEARINGS:STA TE - - - - - - - - - - - PLANE COORDINA TE SYSTEM, MA TCH LINE (SEE SHEET 5) NORTH TEXAS CENTRAL ZONE 4202, NORTH AMERICAN DA TUM OF 1983, ADJUSTMENT REALIZATION 2011. CONTROLLING MONUMENTS: AS SHOWN. RAYMOND L. GOODSON JR., INC. 12001 N. CENTRAL EXPY, STE 300 DALLAS, TX. 75243 214-739-8100 rlg®rlgtimc. con SC/ TEXAS PE REG #F-493 TBPELS REG #100341-00 J05 DRAINAGE EASEMENT TRACT 4 ST. AUGUSTINE ADDITION THOMAS B. TAYLOR SURVEY, ABSTRACT NO. 1539 CITY OF FORT WORTH, TARRANT COUNTY, TEXAS _ _ _ MATCH LINE (SEE SHEET 4) _ _ _ FORT WORTH T INDEPENDENT I SCHOOL DISTRICT I I (NO RECORDING INFORMA TION FOUND) p I CENTERLINE OF STORM TRACT 4 SEWER EASEMENT ST AUGUSTINE ADDITION I i VOL. 3121, PG. 537 ^ h I D.R. T. C. T. VOL. 388-U, PG. 82 I P.R. T. C. T. I i UTILITY EASEMENT UTILITY EASEMENT i VOL. 388-C, PG. 53 5 8 IRF VOL. 388-C, PG. 53 / P.R. T.C. T. \(CM) LU ZI UQ LOT 4 LOT 5 Wig O�Z�►� e1O m�OVC� BLOCK 10 WINDSOR PLACE ADDITION I, o VOL. 388—C, PG. 53 m O 0 25 50 100 P.R. T C. T. (FEET) 1 inch = 50 ft. **NOTE: ALL CORNERS ARE 1/2" IRON ROD WITH YELLOW PLASTIC CAP STAMPED "RLG INC" SET UNLESS OTHERWISE SPECIFIED. SEE SHEET 2 FOR EASEMENT 0 VER VIEW, LINE TABLE & CURVE TABLE, AND LEGEND** BASIS OF BEARINGS. S TA TE PLANE COORDINA TE SYSTEM, NORTH TEXAS CENTRAL ZONE 4202, NORTH AMERICAN DA TUM OF 1983, ADJUSTMENT REALIZATION 2011. CONTROLLING MONUMENTS: AS SHOWN. RAYMOND L. GOODSON JR., INC. 12001 N. CENTRAL EXPY, STE 300 DALLAS, TX. 75243 214-739-8100 �m � s r' • �' BRfAN R WA0,, 808 '`� FssioN''Q SRI . WADE, RPLS NO. 6098 DA TE: 07/08/2026 DRAINAGE EASEMENT TRACT 4 ST. A UGUSTINE ADDITION THOMAS B. TAYLOR SURVEY, ABSTRACT NO. 1539 CITY OF FORT WORTH, TARRANT COUNTY, TEXAS rlg®Tlgira,c. coma, SCALE 1" = 50' DA TE 05-28-2026 SHEET TEXAS PE REG #F-493 TBPELS REG #100341-00 JOB NO. 2621.006 E -FILE 2621.006DE D WG NO. 5OF5 29,004X EXHIBIT "B" DESIGN PLAN AND SPECIFICATIONS UNDERGROUND STORMWATER FACILITY MAINTENANCE AGREEMENT Revised JI) 760 STADIUM DR/VE ' PUBLIC RIGHT -OF -WA Y) PUBLIC J PR VA 7E I � l ii ii I I I I I I I, I I I I ICI 111�_ I1 O iii TRACT 4 Sr AUGUS77NE I ° QZ)iii I ADD/AON , V. 388—U, P. 82 Aj a T PR_T_GT_ Q o BJ. 3816 STADIUM DRIVE LX A FORT WORTH ad I INDEPENDENT I iii — SCHOOL DISTRICT 12/31/1900 Q I I — R __ - a PUBLIL PR/VA 7E } O X. 30" RCP S-163 REF S 147 o � � PROP. ( W SWFMA Al AZ `° o��� I BOUNDARY HI= _I T'\ UL11MATE ONSITE DRAINAGE CONDITIONS [Q�iA] o Drainage Area Cumulative Area (acres) C Al 9.1 0.73 A2 1.19 0.39 B 1.88 0.67 C 1.17 0.62 OWNED/DEVELOPED BY: FORT WORTH INDEPENDENT SCHOOL DISTRICT 700 N. UNIVERSITY DRIVE FORT WORTH, TEXAS 76107 ROBERTE BOWDEN ROBERT.BOWDEN8TFWISD.ORG 1100 "100 (in/hr) (cfs) Remarks INo 7.98 52.73 DRAT N TO PROPOS® DErB'J11 ON POND 0 60 120 (FEET) 7.98 3.73 DErBV11ON POND BYPASS 7.98 10.09 9-IEE f FLOWTO DRYDBV ROAD 7.98 5.78 5-18= f FLOWTO STADIUM DRIVE *NO SA VED OR PROPOSED TREES ARE WITHIN THE SWFMA BOUNDARY LIM/TS* 1 inch = 120 ft. �n (� 1PRC26-0037 Lt�L�J CG26-00166 RLG CONSULTING ENGINEERS PN26-00152 5601 BRIDGE STREET, SUITE 420 CPN: 106813 FORT WORTH, TEXAS 76112 817-687-0080 RL G: #2423. 015 E—MAIL. rlga-lginc.com FIRM RED. F-493 S WFMA SUBM/ T TA L SE T EXHIBIT B. 1 W.P. MCLEAN MIDDLE SCHOOL ADD177ON TRACT 4, ST AUGUS77NE ADD177ON CITY OF FORT WORTH', TARRANT COUNTY, TEXAS 8/10/2026 �i • - • • / - • -� �. �ITTTTTTTTTJ.t ' .., ._._.._., . ._._.._._----- �__ - �i9!i`tfi!YiilYiiYfiYilYfiY�iYiYfiaiY • YYIIIYYYYYY\YIYVIIYYE ■YY1 H\1 , LY II,■■lli 1111''IL" -" - II -• , ., , ��►111 If .. ii■h _ N PROP. MANHOLE W/ GRA TE RIM= 672.42' (OVERFLOW INLET) PR! VA TE ADS STORM TECH CHAMBER DETENTION POND: ALLOWABLE VOLUME = 41,709 CF ACTUAL VOLUME = 42,529 CF XXXXXXXXXXXX ALLOWABLE 0100 = 36.08 CFS ACTUAL 0100 = 36.08 CFS OWNED/DEVELOPED B Y FORT WORTH INDEPENDENT SCHOOL DISTRICT 700 N. UNIVERSITY DRIVE FORT WORTH, TEXAS 76107 ROBERTE BOWDEN ROBERT.BOWDEN6TFWISD.ORG *NO SA VED OR PROPOSED TREES ARE WITH/N THE SWFMA BOUNDARY LIMITS* Qn ( & /PRC26-0037 L CG26-00166 RLG CONSULTING ENGINEERS PN26-00152 5601 BRIDGE STREET, SUITE 420 CPN: 106813 FORT WORTH, TEXAS 76112 817-687-0080 RLG. #2423.015 E—MAIL: rlga-lginc.com FIRM RED. F-493 PROPSED STORM DRAIN EXISTING STORM DRAIN OVERFLOW FLOW PA TH SWFMA SUBM/ T TA L SE T EXHIBIT B.2 W.P. MCLEAN MIDDLE SCHOOL ADD177ON TRACT 4, ST AUGUS77NE ADD177ON CITY OF FORT WORThH, TARRANT COUNTY, TEXAS 8/10/2026 685 .:/ 675 670 L Ti Ti S 665 660 o a� Qz z o �n Woo PROP. SURFACE PROP. AREA DRAINS (SEE ADS NYLOPLAST ® 672.0' DETAILS) PROP. RETAINING WALL L OWES ROP A VING ELEV. 72 0 ISCHARGE WILL LEAD 7 OUTLET STRUCTURE lEN TO EXISTING YSTEM - - °` 61 ' 40TTMCr 666.5 BOTTOM OF STORM TECH CHAMBER 667.50' P O 685 680 675 sE 670 665 660 0+00 1+00 2+00 H: 1" =50' V 1" =5' UNDERGROUND DETENTION POND X -SECTION (A -A) OWNED/DEVELOPED BY: FORT WORTH INDEPENDENT SCHOOL DISTRICT 700 N. UNIVERSITY DRIVE FORT WORTH, TEXAS 76107 ROBERTE BOWDEN ROBERT.BOWDEN8TFWISD.ORG Qn ( /PRC26-0037 L�J CG26-00166 RLG CONSULTING ENGINEERS PN26-00152 5601 BRIDGE STREET, SUITE 420 CPN: 106813 FORT WORTH, TEXAS 76112 817-687-0080 RLG. #2423.015 E-MAIL: rlgalginc.com FIRM RED. F-493 S WFMA SUBM/ T TA L SE T EXHIBIT B.3 W.P. MCLEAN MIDDLE SCHOOL ADD177ON TRACT 4, ST AUGUS77NE ADD171ON CITY OF FORT WORThH, TARRANT COUNTY, TEXAS 8/10/2026 690 690 685 680 675 670 665 660 655 650 W J J O Z PUBL C PR/ ATE O CL 2- .H O Z Z W cv i W �W WW W SOW V W O aOW PROP GRADE EXIST GRADE HGL 0 TC 66700' __:LI_ . o rn "� o � Q •, 680 675 670 665 660 655 650 0+00 1+00 OWNED/DEVELOPED BY.' �//j FORT WORTH INDEPENDENT DETEN / / ON OU TFALL H.- 1" =40' SCHOOL DISTRICT 700 N. UNIVERSITY DRIVE V 1" 5' FORT WORTH, TEXAS 76107 ROBERTE BOWDEN /T-� ROBERT.BOWDEN�TFW/SOORG S w/ MA SUBMITTAL SET EXH/B/T B. 4 /PRC26-0037 W.P. MCLEAN MIDDLE SCHOOL ADD177ON CG26-00166 TRACT 4, ST AUGUS77NE ADD177ON RLG CONSULTING ENGINEERS PN26-00152 CI?)' OF FORT WORTH, TARRANT COUNTY, TEXAS 5601 BRIDGE STREET, SUITE 420 CPN: 106813 FORT WORTH, TEXAS 76112 817-687-0080 8/1 0/2 026 E—MAIL rlga-lginc.com FIRM RED. F-493 RLG. #2423.015 •:/ 1 675 1 670 1 665 1 660 PROP. AREA DRAINS ® 672 0' (SEE ADS NYLOPLAST DETAILS) ___ ___ ___ ___ _______ ___ ) �o v 0 PROP. ADS STORM TECH BETA/N/NG SC -800 CHAMBERS PROP. WALL 67 53" ® 666.50' BOTTOM OF STORM TECH CHAMBER 66750' 685 680 675 WS.E 670 665 660 0+00 1+00 1+50 -40' UNDERGROUND DETENTION POND X -SECTION (B -B) I v- 1'" =5' OWNED/DEVELOPED B Y FORT WORTH INDEPENDENT SCHOOL 0/STRICT 700 N. UNIVERSITY DRIVE FORT WORTH, TEXAS 76107 ROBERT E BOWDEN ROBERT.BOWDEN�TFWISOORG /T-- S w/ MA SUBM/ TTA L SET EXHIBIT B. 5 /PRC26-0037 W.P. MCLEAN MIDDLE SCHOOL ADD177ON CG26-00166 TRACT 4, ST AUGUS77NE ADD177ON RLG CONSULTING ENGINEERS PN26-00152 CITY OF FORT WORTH, TARRANT COUNTY, TEXAS 5601 BRIDGE STREET, SUITE 420 CPN: 106813 FORT WORTH, TEXAS 76112 817-687-0080 E-MAIL: rlgalginc.com FIRM RED. F-493 RLG. #2423.015 8/10/2026 Project: RevO Mclean Middle School //D Chamber Model - SG800 StormTech Units - Imperial Number of Chambers - 475 Number of End Caps - 54 Voids in the stone (porosity) - 40 % Base of Stone Elevation - 666.50 ft Amount of Stone Above Chambers - 9 in Amount of Stone Below Chambers - 12 in Area of system - 17283 1sf Min. Area - 16539 sf min. area 54 000 0.00 0.00 0.00 576.10 576.10 45647.82 671.00 53 0.00 0.00 0.00 0.00 576.10 576.10 45071.72 670.92 52 0.00 0.00 0.00 0.00 576.10 576.10 44495.62 670.83 51 0.00 0.00 0.00 0.00 576.10 576.10 43919.52 670.75 50 0.00 0.00 0.00 0.00 576.10 576.10 43343.42 670.67 49 0.00 0.00 0.00 0.00 576.10 576.10 42767.32 670.58 48 0.00 0.00 0.00 0.00 576.10 576.10 42191.22 670.50 47 0.00 0.00 0.00 0.00 576.10 576.10 41615.12 670.42 46 0.00 0.00 0.00 0.00 576.10 576.10 41039.02 670.33 45 007 0.00 35.37 0.02 561.94 597.33 40462.92 670.25 44 0.20 0.00 93.46 0.19 538.64 63229 39865.58 670.17 43 029 0.01 135.55 0.33 521.75 657.63 39233.29 670.08 42 0.51 0.01 239.89 0.47 479.96 720.32 38575.67 670.00 41 0.74 0.01 351.80 0.74 435.08 787.62 37855.35 669.92 40 0.89 0.02 423.83 1.31 406.04 831.18 37067.72 669.83 39 1.01 0.03 482.06 1.82 382, 55 866.43 36236.54 669.75 38 1.12 0.04 532.05 2.34 362.34 896.73 35370.11 669.67 37 1.21 0.05 576.05 2.85 344.54 923.44 34473.38 669.58 36 1.30 0.06 615.76 3.36 328.45 947.57 33549.94 669.50 35 1.37 0.07 651.81 3.80 313.85 969.47 32602.37 669.42 34 1.44 0.08 684.76 4.22 300.51 989.48 31632.90 669.33 33 1.51 0.09 715.19 4.63 288.17 1007.99 30643.41 669.25 32 1.57 0.09 743.56 5.07 276.65 1025.28 29635.42 669.17 31 1.62 0.10 770.04 5.52 265.87 1041.44 28610.14 669.08 30 1.67 0.11 794.84 5.95 255.78 1056.57 27568.70 669.00 29 1.72 0.12 818.14 6.35 246.30 1070.79 26512.13 668.92 28 1.77 0.12 840.07 6.69 237.40 108416 25441.33 668.83 27 1.81 0.13 860.72 6.93 229.04 109669 24357.18 668.75 26 1.85 0.14 880.20 7.36 221.07 1108.64 23260.49 668.67 25 1.89 0.14 898.60 7.72 213.57 1119.89 22151.85 668.58 24 1.93 0.15 915.98 7.83 206.58 1130.38 21031.96 668.50 23 1.96 0.15 932.41 8.05 199.92 1140.37 19901.57 668.42 22 200 0.16 947.95 8.42 193.55 1149.92 18761.20 668.33 21 203 0.16 962.64 8.84 187.51 115899 17611.28 668.25 20 206 0.17 976.54 9.05 181.86 1167.45 16452.29 668.17 19 2.08 0.17 989.67 9.25 176.53 1175.45 15284.84 668.08 18 2.11 0.18 1002.08 9.48 171.48 118304 14109.39 668.00 17 2,13 0.17 1013.80 9.36 166.84 1189.99 12926.35 667.92 16 2,16 0.18 1024.86 9.80 162.24 1196.90 11736.36 667.83 15 2.18 0.18 1035.28 9.91 158.02 1203.21 10539.46 667.75 14 2.20 0.19 1045.09 10.03 154.05 1209.17 9336.25 667.67 13 2,22 0.13 1055.82 7.14 150.92 1213.87 8127.07 667.58 12 0.00 0.00 0.00 0.00 576.10 576.10 6913.20 667.50 11 0.00 0.00 0.00 0.00 576.10 576.10 6337.10 667.42 10 0.00 0.00 0.00 0.00 576.10 576.10 5761.00 667.33 9 0.00 0.00 0.00 0.00 576.10 576.10 5184.90 667.25 8 0.00 0.00 0.00 0.00 576.10 576.10 4608.80 667.17 7 0.00 0.00 0.00 0.00 576.10 576.10 4032.70 667.08 6 0.00 0.00 0.00 0.00 576.10 576.10 3456.60 667.00 5 0.00 0.00 0.00 0.00 576.10 576.10 2880.50 666.92 OWNED/DEVELOPED BY 4 0.00 0.00 0.00 0.00 576.10 576.10 2304.40 666.83 3 0.00 0.00 0.00 0.00 576.10 576.10 1728.30 666.75 FORT WORTH INDEPENDENT SCHOOL DISTRICT 2 0.00 0.00 0.00 0.00 576.10 576.10 1152.20 666.67 700 N. UNIVERSITY DRIVE 1 0.00 0.00 0.00 0.00 576.10 576.10 576.10 666.58 FORT WORTH, TEXAS 76107 ROBERT E BOWDEN ROBERT.BOWDEPIPFWISOORG SWFMA SUBM/ TTA L SET EXH/B/T B. 6 /PRC26-0037 W.P. MCLEAN MIDDLE SCHOOL ADD177ON CG26-00166 TRACT 4, ST AUGUS77NE ADD/77ON RLG CONSULTING ENGINEERS PN26-00152 C/7)' OF FORT WORTH, TARRANT COUNTY, TEXAS 5601 BRIDGE STREET, SUITE 420 CPN: 106813 FORT WORTH, TEXAS 76112 817-687-0080 E—MAIL: FIRM F-493 PLC: #2423.015 8 10 2026 rlgR*iginc.com REG.' StormTech SC -800 Cumulative Storage Volumes Height of ncrementaIncremental Incremental ncrementa Incremental ncrementa mu ative System Single Chamber Single End Cap Chambers End Cap Stone EC and Stone System Elevation (inches) (cubic feet) (cubic feet) (cubic feet) (cubic feet) (cubic feet) (cubic feet) (cubic feet) (feet) Storm Frequency Volume (cuft) Actual Storage Approx WSE Elev in System 1 13,129 13,129 667.88 1.38 5 22,088 22,088 668.52 2.02 100 41,710 41,710 670.61 4.11 FL at Outlet 666.50 Orifice Center Height Width Area Top Bottom 1 666.75 0.5 2.650 1.33 667.00 666.50 2 668.00 1.000 2.750 2.75 668.50 667.50 Outflow Control Calculations Event WSE C orce Orifice 1 Area (A1) g H orifices Q orifices Corifice Orifice 2 Area (Az) g H orifcez Q orificez Total Q (cfs) ft2 ft /s2 ft cA1 2* *H1 1/2 ft2 ft/s2 ft cAZ 2* *HZ 1/2 Actual Req'd 1 Yr 667.88 0.6 1.33 32.2 1.13 6.78 0.6 2.75 32.2 0.38 8.16 14.94 15.01 5 Yr 668.52 0.6 1.33 32.2 1.77 8.49 0.6 2.75 32.2 1.02 13.37 21.86 21.98 100 Yr 670.61 0.6 1.33 32.2 3.86 12.5 0.6 2.75 32.2 3.11 23.4 35.89 36.08 Outflow Control Calculations L Event WSE Corifice H (Weir Qweir Total Q (cfs) (Height of Weir) Length) ft2 ft [(C +.4(H/Hc)] LH1 5 Actual I Req'd EMERGENCY OVERFLOW 3.27 1.49 6.00 35.68 35.68 36.08 OWNED/DEVELOPED B Y FORT WORTH INDEPENDENT SCHOOL DISTRICT 700 N. UNIVERSITY DRIVE FORT WORTH, TEXAS 76107 ROBERTE BOWDEN ROBERT.BOWDEN6TFWISD.ORG Qn ( /PRC26-0037 L�J CG26-00166 RLG CONSULTING ENGINEERS PN26-00152 G,/ 5601 BRIDGE STREET, SUITE 420 CPN: 1O6813 FORT WORTH, TEXAS 76112 817-687-0080 RLG. #2423.015 E—MAIL. r/ /9lnc.com FIRM RED. F-493 S WFMA SUBM/ T TA L SE T EXHIBIT B. 7 W.P. MCLEAN MIDDLE SCHOOL ADD177ON TRACT 4, ST AUGUS77NE ADD177ON TY OF FORT WOR771, TARRANT COUNTY, TEXAS 8/10/2026 PROPOSED RETAINING WALL ---------- (REFSTRUCTURAL) -- UNDERGROUND ADS DETENTION SYSTEM 1 ' L2x2x/4" 36" ADS PIPE 5'x5' BOX WALL RIM ELEV = 673.4, TOP OF WEIR 100- YR WSE = 670.61 STEEL PLATE 36" RCP I /NVEI 0 0 0 0 36" RCP PROPOSED 15'x5' PROPOSED ✓UNCTION BOX 7/6" GAL VAN/ZED STEEL 5x5' JUNCTION PLATE L,9 SEE SECTION B —B FOR BOX DETAILS DE7FV7faV OU7FZOW SYS7EM PLAN NEW NTS 5' o IoW o � 5' EMERGENCY OVERFLOW WEIR 1.00' k 3.00': 1.00' I I I1. II I. i.i 2.75'i I I I 0 0.67' PROPOSED 5'x11' I 21.65 1 I JUNG 170N BOX I �I DE7EN7l/7FLOW 30"x24 " ADS N-12 SEC77QN B -B - S7EEL PLA7F MANIFOLD N75 LE 11/ OWNED/DEVELOPED BY.' II OPEN FLOW AREA DE7DV71QN INFLOW FORT WORTH INDEPENDENT STRUCTURE PLAN SCHOOL DISTRICT 700 N. UNIVERSITY DRIVE ME FORT WORTHTEXAS 76107 N75 ROBERT E BOWDEN /T-- ROBERT.BOWDEN�TFW/SOORG S w/ MA SLBM/ TTA L SET EXHIBIT B. 8 /PRC26-0037 W.P. MCLEAN MIDDLE SCHOOL ADD177ON CG26-00166 TRACT 4, ST AUGUS77NE ADD177ON RLG CONSULTING ENGINEERS PN26-00152 CITY OF FORT WORTH, TARRANT COUNTY, TEXAS 5601 BRIDGE STREET, SUITE 420 CPN: 106813 FORT WORTH, TEXAS 76112 817-687-0080 E-MAIL rlgalginc.com FIRM RED. F-493 RLG: #2423.015 8/10/2026 .C.T. INSTALL INLET PROTECT/ON . (TYP) 20 INAON II 20 ADDITION P.376 aT. INSTALL INSTALL ORGAN/C TUBE (TYP.) �p J (VARIABLE WI�TN UIVLIC R�GNOF WAY) F JY INS TALL SILT FENCE ' ' `� L (TYP.) INSTALL ORGANIC INSTALL TUBE INLET rT s (TYP.) PROTECTION 1 ACT 4 (TYP) I Sr. Auays>eE AOOIAILW Y. Jee-L P. 62 INLET ,,L 7 PROTECTION (TYP) it PROPOSED 10' ONCOR EASEMENT BY SEPARA TE INSTRUMENT I I is D DrnON 316 T INSTALL SILT FENCE (TYP.) ecoar 1D {H OSOR PLA *NO SA VED OR PROPOSED TREES ARE WI THIN THE SWFMA BOUNDARY LIMI TS* OWNED/DEVELOPED BY' FORT WORTH INDEPENDENT SCHOOL DISTRICT 700 N. UNIVERSITY DRIVE FORT WORTH, TEXAS 76107 ROBERTE BOWDEN ROSERT.BOWDEN6TFWISD.ORG Qn /PRC26-0037 L�J CG26-00166 RLG CONSULTING ENGINEERS PN26-00152 5601 BRIDGE STREET, SUITE 420 CPN: 106813 FORT WORTH, TEXAS 76112 817-687-0080 RLG. #2423.015 E-MAIL rlgalginc.com FIRM RED. F-493 P.R. .7816 STADIJU %'IF FORT IK Th' AvBg mwr SL'f D T F IOSED MADM ~~67550 LANDSCAPE AREA DRAINS A0 LANA DSCAPE INSTALL INLET PROTECTION (TYP) O yIN L INSTALL ORGANIC TUBE (TYP.) 1� INSTALL SIL T FENCE ____ r -N- _____ (TYP.) 6A iglu IIILj LE2M INSTALL INLET PROTECTION INS TALL SILT FENCE ORGANIC FILTER TUBE 60 120 eBe PROPOSED CONTOUR LINE INSTALL 50' TEMPORARY (FEET) CONSTRUCTION ENTRANCE 1 inch = 120 ft. SWFMA SUBM/ T TA L SE T EXHIBIT B. 9 W.P. MCLEAN MIDDLE SCHOOL ADD/71ON TRACT 4, ST AUGUS77NE ADD/77ON CITY OF FORT WORThH, TARRANT COUNTY, TEXAS 8/10/2026 1-1/2" X 1-1/2" POST 75' (APPROX..) BEL TECH SIL T FENCE 751 37" WIDTH OR APPROVED EQUIVALENT. EXISTING GRADE-\ BACK FILL 1-1/2" X 1-1/2" POST \j\ \ ����6" X 6" TRENCH 7.5' (APPROX.)\\��\��`/� N FIL TER FABRIC TO I I EXTEND INTO TRENCH POST FABRIC 1 1 I I FLOW DIRECTION ' r PLAN VIEW SECTION BEL TECH SIL T FENCE 751 37" WIDTH OR APPROVED EQUIVALENT. EXCA VA TE 6" TRENCH & TOE IN FABRIC WITH TRENCH SPOIL OWNED/DEVELOPED BY: FORT WORTH INDEPENDENT SCHOOL 0/STRICT 100 N. UNIVERSITY DRIVE FORT WORTH. TEXAS 76107 ROBERTS BOWDEN ROBERT.BOWDEN�IFWISD.ORG 1-1/2" X 1-1/2" POST 7.5' (APPROX) Nrs I1U1U 111 llllllllllilllllllllllllllllllllll 1 lU ll U1 llllllllllllilllllllllllllll U U1 1 lU U U U llllllilllllllllllll111.11lllllllll 1 llllllllll llllllll ll lllllllllllllllllllU U 1 llllllllll 111111111111111111illlllllllllllll 1 llllllllll lllllllllllllllllllllllllllllU U 1 llllllllll 1111111111 llllll1U1UllllllllllUiiUUUU 1 1111111111111 1111111.11111111111111 1 ELEVA TION SIL T FENCE DETAIL SWFMA SUBMITTAL SE T EXHIBIT B. 10 IPRC26-0037 W.P. MCLEAN MIDDLE SCHOOL ADD171ON CG26-00166 TRACT 4, ST AUGUSTINE ADDITION RLG CONSULTING ENGINEERS PN26-00152 CITY OF FORT WORTH, TARRANT COUNTY, TEXAS 5601 BRIDGE STREET, SU/iF 420 CPN: 106813 FORT WORTH, TEXAS 76112 817-687-0080 /202610/ E—MAIL: r/g8-/ginc.com FIRM REG. F-493 RLG.• #2423.015 8 o� �I ORGANIC -1 r1 FILTER TUBE 25' MAX. METAL OR WOODEN WI STAKES AT 6 TO 8 FOOT INTERVALS PLAN VIEW TUBULAR MESH (GEOSYNTHETIC, PLASTIC, JUTE, OR DIAMETER AS COIR) SPECIFIED ON PLANS � r3' MIN. OVERLAP METAL OR WOODEN STAKES AT 6 TO 8 FOOT INTERVALS FILTER MATERIAL (COMPOST, -" MULCH, STRAW, COIR, OR MIXTURE) F®„O ENDS TIED CLOSED EXISTING GRADE ORGANIC FILTER TUBE DETAIL GRADE TO PREVENT PLAN VIEW OWNED/DEVELOPED BY.' FORT WORTH INDEPENDENT SCHOOL DISTRICT 700 N. UNIVERSITY DRIVE FORT WORTH, TEXAS 76107 ROBERTE BOWDEN ROBERT.BOWDEN6TFWISD.ORG STABILIZED CONSTRUCTION EN TRANCE NO TE: CON TRA C TOR TO L OCA TE A MINIMUM NTs OF ONE CONSTRUCTION ENTRANCE ON -SITE S WFMA SUBM/ TTAL SE T EXHIBIT B. 11 /PRC26-0037 W.P. MCLEAN MIDDLE SCHOOL ADD/770N CG26-00166 TRACT 4, ST AUGUS77NE ADD/77ON RLG CONSULTING ENGINEERS PN26-00152 CITY OF FORT WORTH, TARRANT COUNTY, TEXAS 5601 BRIDGE STREET, SUITE 420 CPN: 1O6813 FORT WORTH, TEXAS 76112 817-687-0080 E-MAIL rlgalginc.com FIRM RED. F-493 RLG. #2423.015 8/10/2026 WIRE SCREEN AROUND PERIMETER OF CONCRETE BLOCKS TO PREVENT MOVEMENT OF GRA VEL CONCRETE BLOCKS OVERFLOW WIRE SCREEN RUNOFF PA VEMEN T 2"x4" WOOD STUD FIL TERED RUNOFF CROSS-SECTION B -B GRA VEL FIL TER (APPROXIM ^ TC' " 3/4 "-INCH DIAMETER) Pb TOP OF CONCRETE BLOCKS WIRE SCREEN PLACE AROUND CONCRETE BLOCK PERIMETER OWNED/DEVELOPED BY: FORT WORTH INDEPENDENT SCHOOL DISTRICT 700 N. UNIVERSITY DRIVE FORT WORTH, TEXAS 76107 ROBERTS BOWDEN ROBERTBOWDEN1 FWISD. ORG �n (� 1PRC26-0037 CG26-00166 RLG CONSULTING ENGINEERS PN26-00152 5601 BRIDGE STREET, SUITE 420 CPN: 106813 FORT WORTH, TEXAS 76112 817-687-0080 RLG. #2423.015 E—MAIL: /g6Ylginc.com FIRM RED F-493 2'x4" WOOD STUD EXTENDED INTO CONCRETE BLOCKS GRA VEL FIL TER (APPROX/MA TEL Y 3/4 -INCH DIAMETER) PLACED TO TOP OF CONCRETE BLOCKS PLAN CONCRETE BLOCKS FIL TERED STACKED 2 HIGH WA TER OVERFLOW WIRE SCREEN TO PREVENT MOVEMENT OF GRA VEL CROSS-SECTION A -A NCRETE BLOCKS ACED AROUND DROP .ET PERIMETER AREA INLET WITH CRATE PLAN INLET PROTECTION DETAILS N TS SWFMA SUBMITTAL SE T EXHIBIT B. 12 W.P. MCLEAN MIDDLE SCHOOL ADDITION TRACT 4, ST AUGUSTINE ADDITION CITY OF FORT WORTH, TARRANT COUNTY, TEXAS 8/10/2026 EXHIBIT C Exhibit "C" CITY OF FORT WORTH STORMWATER FACILITY OPERATION AND MAINTENANCE PLAN The only responsibility the City of Fort Worth has in the operation and maintenance of this Facility is inspection. General Maintenance Procedures The structural and functional integrity of the Facility shall be maintained at all times by removing and preventing drainage interference, obstructions, blockages, or other adverse effects into, through, or out of the system. Periodic silt removal shall occur when standing water conditions occur or the pond's storage volume is reduced by more than 10%. Silt shall be removed and the pond/basin returned to original lines and grades shown on the approved engineering plans. In addition, corrective measures are required any time a basin does not drain completely within 72 hours of cessation of inflow. NO STANDING WATER IS ALLOWED in basins designed for dry detention purposes. Accumulated litter, sediment, and debris shall be removed every 6 months or as necessary to maintain proper operation of the basin. Disposal shall be in accordance with federal, state and local regulations. Detention facilities shall be mowed monthly between the months of April and October or anytime vegetation exceeds 12 -inches in height. To prevent debris from entering and clogging the downstream storm sewer system a wire mesh screen or similar screening device shall be installed over the outlet until final acceptance. 4. PREVENTIVE MAINTENANCE/INSPECTION • Visual inspections of all components will be conducted every 6 months. • A log shall be kept of maintenance actions, and inspections. The log should document the condition of the detention system's primary components, mowing, and silt, litter and debris removal dates. Document aeration of the basin bottoms and replanting to prevent the sealing of the basin bottom. • Written maintenance and repair records shall be maintained by the party or parties signing the attached Agreement and shall be provided to the City upon request. STORMWATER FACILITY MAINTENANCE AGREEMENT 10 Rev. 11/19/2020 JLE •I; Iry Row F Manual The Isolator® Row Plus Introduction An important component of any Stormwater Pollution Prevention Plan is inspection and maintenance. The StormTech Isolator Row Plus is a technique to inexpensively enhance Total Suspended Solids (TSS), Total Phosphorus (TP), Total Petroluem Hydrocarbons (TPH) and Total Nitrogen (TN) removal with easy access for inspection and maintenance. The Isolator Row Plus The Isolator Row Plus is a row of StormTech chambers, either SC -160, SC - 310, DC -780, SC -800, MC -3500, MC -4500 or MC -7200 models, are lined with filter fabric and connected to a closely located manhole for easy access. The fabric lined chambers provide for sediment settling and filtration as stormwater rises in the Isolator Row Plus and passes through the filter fabric. The open bottom chambers allow stormwater to flow vertically out of the chambers. Sediments are captured in the Isolator Row Plus protecting the adjacent stone and chambers storage areas from sediment accumulation. ADS Isolator Row and Plus fabric are placed between the stone and the Isolator Row Plus chambers. The woven geotextile provides a media for stormwater filtration, a durable surface for maintenance, prevents scour of the underlying stone and remains intact during high pressure jetting. The Isolator Row Plus is designed to capture the "first flush" runoff and offers the versatility to be sized on a volume basis or a flow -rate basis. An upstream manhole provides access to the Isolator Row Plus and includes a high/low concept such that stormwater flow rates or volumes that exceed the capacity of the Isolator Row Plus bypass through a manifold to the other chambers. This is achieved with an elevated bypass manifold or a high -flow weir. This creates a differential between the Isolator Row Plus row of chambers and the manifold to the rest of the system, thus allowing for settlement time in the Isolator Row Plus. After Stormwater flows through the Isolator Row Plus and into the rest of the chamber system it is either exfiltrated into the soils below or passed at a controlled rate through an outlet manifold and outlet control structure. The Isolator Row Plus FlampTM is a flared end ramp apparatus attached to the inlet pipe on the inside of the chamber end cap. The FLAMP provides a smooth transition from pipe invert to fabric bottom. It is configured to improve chamber function performance by enhancing outflow of solid debris that would otherwise collect at the chamber's end, or more difficult to remove and require confined space entry into the chamber area. It also serves to improve the fluid and solid flow into the access pipe during maintenance and cleaning and to guide cleaning and inspection equipment back into the inlet pipe when complete. The Isolator Row Plus may be part of a treatment train system. The treatment train design and pretreatment device selection by the design engineer is often driven by regulatory requirements. Whether pretreatment is used or not, StormTech recommend using the Isolator Row Plus to minimize maintenance requirements and maintenance costs. Note: See the StormTech Design Manual for detailed information on designing inlets for a StormTech system, including the Isolator Row Plus. Looking down the Isolator Row Plus from the manhole opening, ADS Plus Fabric is shown between the chamber and stone base. StormTech Isolator Row Plus with Overflow Structure (not to scale) T w/ELMVEo a.Pau E ISOLATOR ROW PL°s FL W THROUGH STOOD µF�'owwO �. INLET MANIFOLD L �� �� °nE,MAR1F°L° �� ° OUTLET CON -L - STRUCTURE 'I I, wo ER F�RR ° F°R E-UR RR°TE°T�°R Isolator Row Plus Inspection/Maintenance Inspection The frequency of inspection and maintenance varies by location. A routine inspection schedule needs to be established for each individual location based upon site specific variables. The type of land use (i.e. industrial, commercial, residential), anticipated pollutant load, percent imperviousness, climate, etc. all play a critical role in determining the actual frequency of inspection and maintenance practices. At a minimum, StormTech recommends annual inspections. Initially, the Isolator Row Plus should be inspected every 6 months for the first year of operation. For subsequent years, the inspection should be adjusted based upon previous observation of sediment deposition. The Isolator Row Plus incorporates a combination of standard manhole(s) and strategically located inspection ports (as needed). The inspection ports allow for easy access to the system from the surface, eliminating the need to perform a confined space entry for inspection purposes. If upon visual inspection it is found that sediment has accumulated, a stadia rod should be inserted to determine the depth of sediment. When the average depth of sediment exceeds 3" (75 mm) throughout the length of the Isolator Row Plus, clean -out should be performed. Maintenance The Isolator Row Plus was designed to reduce the cost of periodic maintenance. By "isolating" sediments to just one row, costs are dramatically reduced by eliminating the need to clean out each row of the entire storage bed. If inspection indicates the potential need for maintenance, access is provided StormTech Isolator Row Plus (not to scale) FLE77faFOlil INSOIIS M NIY LP'SIRGIIM SllgICNRES lVl1H OP@I0MTES BE�Al7RED fl A!9 MNMF= BURPPEPTHTBCRY NMCM1M FMJNffA 24 PM mma IDI RIMa via a manhole(s) located on the end(s) of the row for cleanout. If entry into the manhole is required, please follow local and OSHA rules for a confined space entry. Maintenance is accomplished with the JetVac process. The JetVac process utilizes a high pressure water nozzle to propel itself down the Isolator Row Plus while scouring and suspending sediments. As the nozzle is retrieved, the captured pollutants are flushed back into the manhole for vacuuming. Most sewer and pipe maintenance companies have vacuum/JetVac combination vehicles. Selection of an appropriate JetVac nozzle will improve maintenance efficiency. Fixed nozzles designed for culverts or large diameter pipe cleaning are preferable. Rear facing jets with an effective spread of at least 45" are best. StormTech recommends a maximum nozzle pressure of 2000 psi be utilized during cleaning. JetVac reels can vary in length. For ease of maintenance, ADS recommends Isolator Row Plus lengths up to 200' (61 m). The JetVac process shall only be performed on StormTech Isolator Row Plus that have ADS Plus Fabric (as specified by StormTech) over their angular base stone. or,==OAP ONE LAYER a UO SPIJl9e1S VKAM OEa7ERRF BElV1 MUNDATI N MMAN CKAMM sn.im)NlN WMEOMMOA FANSC Wmloura rt CD I CD CDV X CD CD CD CD CD '-r CD I!. 0 1 0 1 CD C) a CD C) CD C) CD U) CD (n w ry N co 0)cn 0 — . CD CD m cD < CD CD 0 0 -' cD CD m(0 m �. CD con O m v CDCD CDCDv v �, 0 v v rt ≤≤ 0 ,< C �. v << v (D o 0 -CD (D 0 N rt ,L C) 0 No -8 0 CD CD _ D C) CD CD 0 Q `< CZ 7 0 CD -5CDCD -s_ E CD CD 0 O� O 0 0 CCD 0 J O� -5 fn sll U) CD _ (n 0 j CD (D (np S CD O C) o0 -CD CDCD ' CD �, .�M. < O O < (D OCD CD m-0 o CD 0 0- CD 0 3 J ≤ v c CD' CD O J J 0 CD CD rnr CD CD CD CD O3 CD CD J QCD ((DD CZ CD N •J CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD (n CD 0 (n CD (1) CD (n Cn CD CD z z z z z z z z z z z z z 0 0 0 0 0 0 0 0 0 0 0 0 0 OOOOO OOOOOOOO 0 0 0 0 0 0 0 0 0 0 0 0 0 (D CD (D CD CD CD (D CD (D (D CD (D CD CD Cn Cn CD CD CD (n CD CD CD w N 0 0 CD CD CD CD CD v o 0- 0 oCD CD CD CD 0 0 CDCD 0 73 CD CD C) v C) CD C) •J CD CD CD (n z z 00 OO 00 CDCD CD CD W fu U. O 0 a O U) CD 0 h U) CD O 0 CD rR CD (D 0 0 CD 0 0 m CD 0 - CD CD CD C) CD CD CD N 0 a z a CD U) CD C) CD Q ou rt CD -n w C) 1< z CD -n w C) rt cQ CD CD 3 CD z 3 a - CD Isolator Row Plus Step By Step Maintenance Procedures Step 1 Inspect Isolator Row Plus for sediment. A) Inspection ports (if present) i. Remove lid from floor box frame ii. Remove cap from inspection riser iii. Using a flashlight and stadia rod,measure depth of sediment and record results on maintenance log. iv. If sediment is at or above 3 inch depth, proceed to Step 2. If not, proceed to Step 3. B) All Isolator Row Plus i. Remove cover from manhole at upstream end of Isolator Row Plus ii. Using a flashlight, inspect down Isolator Row Plus through outlet pipe 1. Mirrors on poles or cameras may be used to avoid a confined space entry 2. Follow OSHA regulations for confined space entry if entering manhole iii. If sediment is at or above the lower row of sidewall holes (approximately 3 inches), proceed to Step 2. If not, proceed to Step 3. Step 2 Clean out Isolator Row Plus using the JetVac process. A) A fixed floor cleaning nozzle with rear facing nozzle spread of 45 inches or more is preferable B) Apply multiple passes of JetVac until backflush water is clean C) Vacuum manhole sump as required Step 3 Replace all caps, lids and covers, record observations and actions. Step 4 Inspect & clean catch basins and manholes upstream of the StormTech system. Sample Maintenance Log 3/15/11 6.3 fE tnoR1e New L sEaLLeEioti, Fixed D0M poLtiE is CI frame o E grade 9/24/11 6,2 0,1 fE Some 9rLE f eLE SM /20/13 $.Fs 0.5 fE Mucky feel, debris visible Nd Lk vnek hole and tk IsoLo Eor Row PLus, rvtaL Eeka ce due 7/7/13 6.3 f E O SysEern jeEEeci oral T )M vacuumed ADS "Terms and Conditions of Sale" are available on the ADS website, www.adspipe.com The ADS logo. StormTeche, the Isolators Row Plus and the Green Stripe are registered trademarks Of Advanced Drainage Systems, Inc. Cc 2025 Advanced Drainage Systems, Inc, #11081 5/25 CS StormTech FORT WORTH® City Secretary's Office Contract Routing & Transmittal Slip Contractor's Name: Fort Worth Independent School District Subject of the Agreement: Underground SWFMA needed for new construction M&C Approved by the Council? * Yes ❑ No II If so, the M&C must be attached to the contract. Is this an Amendment to an Existing contract? Yes ❑ No 0 If so, provide the original contract number and the amendment number. Is the Contract "Permanent"? *Yes 0 No ❑ If unsure, see back page for permanent contract listing. Is this entire contract Confidential? *Yes ❑ No 0 If only specific information is Confidential, please list what information is Confidential and the page it is located. Effective Date: If different from the approval date. Expiration Date: If applicable. Is a 1295 Form required? * Yes ❑ No 21 *If so, please ensure it is attached to the approving M&C or attached to the contract. Project Number: If applicable. SW F MA -26-0045 *Did you include a Text field on the contract to add the City Secretary Contract (CSC) number? Yes 0 No 0 Contracts need to be routed for CSO processing in the following order: 1. Katherine Cenicola (Approver) 2. Jannette S. Goodall (Signer) 3. Allison Tidwell (Form Filler) *Indicates the information is required and if the information is not provided, the contract will be returned to the department.