Loading...
HomeMy WebLinkAboutContract 29949 CITY SECRETARY �1 "ONTRACT NO. SPECIAL CONTRACT DOCUMENTS FOR LAKE WORTH SOUTH SHORE GRAVITY SEWER SYSTEM WATER DEPARTMENT PROJECT NO. P171-070171131150 k GARY JACKSON CITY MANAGER r DALE A. FISSELER, P.E. DIRECTOR WATER DEPARTMENT A. DOUGLAS RADEMAKER, P.E. S. FRANK CRUMB, P.E. DIRECTOR ENGINEERING MANAGER DEPARTMENT OF ENGINEERING WATER DEPARTMENT All .:.'..I ...' .REY.... ... .......... ... tib; 81$96 ORIGINAL ' °it%'I'aw- City of Fort Worth, Texas Mayor and Council Communication COUNCIL ACTION: Approved on 3/23/2004 DATE: Tuesday, March 23, 2004 LOG NAME: 60TRITECH REFERENCE NO.: **C-20007 SUBJECT: Award of Contract to Tri-Tech Construction, Inc. for the Construction of the Lake Worth South Shore Gravity Sewer Improvements RECOMMENDATION: It is recommended that the City Council authorize the City Manager to execute a contract with Tri-Tech Construction, Inc. for the construction of the Lake Worth South Shore Gravity Sewer Improvements, in an amount not to exceed $869,786.00. DISCUSSION: On March 26, 2002 (M&C C-19022), the City Council authorized an engineering agreement with Alan Plummer and Associates, Inc., which included the design of the Lake Worth South Shore gravity, and low- pressure sanitary sewer system. This system would provide sewer service to existing residents along the south shore of Lake Worth. The Lake Worth South Shore Gravity Sewer Improvements Project will install approximately two miles of gravity sewer main from the 9600 block to the 8600 block of Heron Road and Castle Circle. This project will provide sewer service to approximately eighty one developed Lake Worth lots, and allow future service to be provided in the area south of Lake Worth. The project was advertised for bid on August 21 and 28, 2003. On January 15, 2004, the following bids were received: BIDDERS AMOUNT COMPLETION Tri-Tech Construction, Inc. $ 859,786.00 210 Calendar Days Jackson Construction, Ltd. $ 988,773.00 William J. Schultz, Inc. d/b/a Circle "C"Construction $1,092,545.00* AU I Contractors, L.P. $1,156,587.08 Patco Utilities, Inc. $1,188,515.72 Hall Albert Construction Company $1,206,016.00 Atkins Brothers $1,338,337.00 Note (*) reflects that total amount bid had been adjusted to reflect amount actual bid due to a mathematical error. In addition to the contract amount, $26,093.00 is included for possible change orders, and contingencies, $5,000.00 for Water Department staff support and review, and $26,000 for Department of Engineering construction services. Lnvnnme- 60TRTTP( T4 parte .,f7 This project is located in COUNCIL DISTRICT 7. Tri-Tech Construction, Inc. is in compliance with the City's M/WBE Ordinance by committing to 6% M/WBE participation and documenting good faith effort. Tri-Tech Construction, Inc. identified several subcontracting and supplier opportunities. However, the M/WBEs contacted in the areas identified did not submit the lowest bids. The City's goal on this project is 17%. FISCAL INFORMATION/CERTIFICATION: The Finance Director certifies that funds are available in the current capital budget, as appropriated, of the Sewer Capital Project Fund. TO Fund/Account/Centers FROM Fund/Account/Centers P173 541200 070173013245 $869.786.00 Submitted for City Manager's Office bk Marc Ott (8476) Originating Department Head: Dale Fisseler (8207) Additional Information Contact: Dale Fisseler (8207) 1.ognnme- 60TRITF.0 H 318-3200 ADDENDUM NO. 1 TO PLANS, SPECIFICATIONS, AND CONTRACT DOCUMENTS FOR CITY OF FORT WORTH LAKE WORTH SOUTH SHORE GRAVITY SEWER SYSTEM T TO: PROSPECTIVE BIDDERS AND PLAN HOLDERS The Plans, Specifications and Contract Documents shall be modified as required by the following items: Item 1-1 Specifications, PART B— PROPOSAL: Delete in its entirety and replace with the attached revised PROPOSAL(Attachment 1-AD1). Note the following items are modified in the attachment: Bid Item Nos. 7 through 24 are specified as SDR 26 PVC. Bid Item 38 is added. Several quantities are adjusted. The time of final completion is changed from "135 calendar days" to "210 calendar days". Item 1-2 Specifications, Appendix C—SOIL BORING LOGS: The location of the soil borings is shown on Sheet G-003. Item 1-3 Plans, Sheet C-6, LINE B—STATION 0+27.20 TO STATION 9+50: Delete in its entirety and replace with the attached revised Sheet C-6R (Attachment 2-AD1). Item 1-4 Plans, Sheet C-7, LINE B—STATION 9+50 TO STATION 19+00: Delete in its entirety and replace with the attached revised Sheet C-7R (Attachment 3-AD1). F.\projects\318\3200\,SpecsWDDENDUM_1.doc Addendum No. 1 - Page 1 318-3200 Item 1-5 Plans, Sheet C-8, LINE B—STATION 19+00 TO STATION 29+00: Delete in its entirety and replace with the attached revised Sheet C-8R(Attachment 4-AD1). ,. Item 1-6 Plans, Sheet C-10, LINE B—STATION 39+00 TO STATION 48+71.72: Delete in its entirety and replace with the attached revised Sheet C-1 OR(Attachment 5-AD1). Item 1-7 Plans, Sheet C-902, STANDARD DETAILS, SANITARY SEWER LATERAL: Add the following note: "6. DEPTH OF SEWER LATERAL SHALL BE DETERMINED IN THE FIELD. COORDINATE WITH HOME OWNER AND CITY. SOME HOUSES WILL NEED TO PUMP TO THE GRAVITY SEWER AND THOSE LATERALS MAY HAVE THE MINIMUM DEPTH;OTHERS MAY REQUIRE A DEEPER GRADE(8-FOOT MAXIMUM) FOR GRAVITY SERVICE. THE PRICE IN THE BID ITEM SHALL ALLOW FOR VARIABILITY OF DEPTH AT NO ADDITIONAL COST TO CITY." All items in conflict with this addendum are hereby deleted. THIS ADDENDUM IS MADE PART OF THE SPECIFICATIONS AND CONTRACT DOCUMENTS, AND SHALL BE ACKNOWLEDGED ON THE PROPOSAL AND ON THE BID ENVELOPE. ALAN PLUMMER ASSOCIATES, INC. ,.� of a ee ............................. Jeffrey E. Caffey, P.E. a. ' E.CAFFEII .� September 12, 2003 ®p 81896 ;meq, / •• stis•..a�. sf rL�d3 F.\projects4318\3200\.SpecsWDDENDUM_1.doc Addendum No. 1 - Page 2 318-3200 PART B - PROPOSAL (This proposal must not be removed from this book of Contract Documents.) TO: Mr. Gary Jackson City Manager Fort Worth, Texas PROPOSAL FOR: furnishing of all materials and equipment and labor and all necessary appurtenances and incidental work to provide a complete and operable project designated as: Lake Worth South Shore Gravity Sewer System Water Dept. Project No. P171-070171131150 Pursuant to the foregoing Notice to Bidders,the undersigned Bidder, having thoroughly examined the Contract Documents, including plans, special documents and the General Specifications for Water Department Projects, the site of the project and understanding the amount of work to be done, and the prevailing conditions hereby proposes to do all the work, furnish all the labor, equipment and material, except as specified to be furnished by the City,which is necessary to fully complete the work as provided in the plans and contract Documents and subject to the inspection and approval of the Director of the City Water Department of the City of Fort Worth, Texas; and binds himself upon acceptance of this proposal to execute a contract and furnish an approved Performance Bond, Payment Bond, Maintenance Bond, and such other bonds, if any, as may be required by the Contract Documents for the performing and completing of the said work. Contractor proposes to do the work within the time stated and for the following sums: F:Vrolectsl318\3200\Specs\Part B ADI Am B-1 ATTACHMENT 1-AD1 318-3200 Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 1 1 LS Connect 12-inch PVC gravity sewer pipe to existing 12-inch gravity sewer pipe at Line A: Station 1+01.76 in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, fittings, and accessories as specified or shown, complete in place for the lump sum of Dollars and Cents. $ $ 2 54 EA Furnish and install standard 6-foot deep concrete manholes in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, fittings, concrete, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per each. 3 287 VF Provide excavation to depths greater than 6 feet as required to construct manholes in accordance with the drawings and specification,complete in place for the sum of Dollars and Cents per vertical foot. $ $ 2 EA Furnish and install shallow concrete manhole,including excavation,backfill, fittings, and appurtenances as specified or shown, complete in place for the sum of Dollars and Cents per each. $ $ E FAprolects\318\3200\Specs\PartB_AD1 Am B-2 ATTACHMENT 1-AD1 318-3200 Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 5 40 VF Coat interior manhole surfaces for manholes shown to be coated in accordance with the drawings and specification, complete in place for the sum of Dollars and Cents per vertical foot of manhole depth. $ 6 5 EA Furnish and install sweet street air _ filters in manholes in accordance with the drawings and specification, complete in place for the sum of_ Dollars and Cents per each. $ $ 7 125 LF Furnish and install 8-inch SDR 26 PVC sewer pipe, 4-foot to 6 foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, detectable warning tape, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ 8 715 LF Furnish and install 8-inch SDR 26 PVC sewer pipe, 6-foot to 8-foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, detectable warning tape, and accessories as specified or shown, complete in place for the sum of— Dollars and Cents per linear foot. $ $ FAprojectO18k3200kSpecskPartB AD1.doc B-3 ATTACHMENT 1-AD1 318-3200 Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 9 625 LF Furnish and install 8-inch SDR 26 PVC sewer pipe, 8-foot to 10-foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, detectable warning tape, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ $ 0 50 LF Furnish and install 8-inch SDR 26 PVC sewer pipe, 10-foot to 12-foot trench,in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, detectable warning tape, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ $ 11 80 LF Furnish and install 8-inch SDR 26 PVC sewer pipe, 12-foot to 14-foot trench,in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, detectable warning tape, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ $ FAprojects\318\3200\Specs\Part B AD1.doc B-4 ATTACHMENT 1-AD1 318-3200 Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 12 750 LF Furnish and install 10-inch SDR 26 PVC sewer pipe, 6-foot to 8-foot _ trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, detectable warning tape, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ 13 830 LF Furnish and install 10-inch SDR 26 PVC sewer pipe, 8-foot to 10-foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, detectable warning tape, and accessories as specified or shown, complete in place for the sum Of Dollars and Cents per linear foot. $ 14 490 LF Furnish and install 10-inch SDR 26 PVC sewer pipe, 10-foot to 12-foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, detectable warning tape, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ R\prolecW\316\3200\Specs\PartB AD1.doc B-5 ATTACHMENT 1-AD1 318-3200 Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 15 145 LF Furnish and install 10-inch SDR 26 PVC sewer pipe, 12-foot to 14-foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, detectable warning tape, and accessories as specified or shown, complete in place for the sum Of Dollars and Cents per linear foot. $ 16 185 LF Furnish and install 12-inch SDR 26 PVC sewer pipe, 4-foot to 6-foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, boring, fittings, detectable warning tape, concrete blocking, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ $ 17 885 LF Furnish and install 12-inch SDR 26 PVC sewer pipe, 6-foot to 8-foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, boring, fittings, detectable warning tape, concrete blocking, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ $ FAprojects\318\3200\Specs\Part B AD1.doc B-6 ATTACHMENT 1-ADI 318-3200 Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 18 1040 LF Furnish and install 12-inch SDR 26 PVC sewer pipe, 8-foot to 10-foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, boring, fittings, detectable warning tape, concrete blocking, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ $ 19 2290 LF Furnish and install 12-inch SDR 26 PVC sewer pipe, 10-foot to 12-foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, boring, fittings, detectable warning tape, concrete blocking, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ 20 1010 LF Furnish and install 12-inch SDR 26 PVC sewer pipe, 12-foot to 14-foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, boring, fittings, detectable warning tape, concrete blocking, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. F.\projecW18\3200\Specs\Part 13AD1.doc B-7 ATTACHMENT 1-AD1 318-3200 Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 21 290 LF Furnish and install 12-inch SDR 26 PVC sewer pipe, 14-foot to 16-foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, boring, fittings, detectable warning tape, concrete blocking, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ $ 22 485 LF Furnish and install 12-inch SDR 26 PVC sewer pipe, 16-foot to 18-foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, boring, fittings, detectable warning tape, concrete blocking, and accessories as specified or shown, complete in place for the sum of_ Dollars and Cents per linear foot. 23 575 LF Furnish and install 12-inch SDR 26 PVC sewer pipe, 18-foot to 20-foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, boring, fittings, detectable warning tape, concrete blocking, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ FI Aprojects\318\3200\Specs\Part B AD1.doc B-8 ATTACHMENT 1-AD1 318-3200 Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 24 150 LF Furnish and install 12-inch SDR 26 PVC sewer pipe, 20-foot to 22-foot trench, in accordance with the drawings and specification, including clearing trees and brush, excavation, backfilling, boring, fittings, detectable warning tape, concrete blocking, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ 25 2320 LF Furnish and install a 4-inch PVC service line from sanitary sewer main to property line, including excavation, backfill,fittings,plug,pavement repair, as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ $ 26 77 EA Furnish and install tee on sanitary sewer main for service line connection, as specified or shown, complete in place for the sum of Dollars and Cents per each. $ $ 27 40 LF Furnish and install a 6-inch PVC service line from manhole to property line at Castle property, including excavation, backfill, fittings pavement repair, topsoil and sod around valve box, as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ FAprojects\318\3200\Specs\Part B ADI A= B-9 ATTACH M ENT 1-AD 1 318-3200 Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 28 3 EA Furnish and install 4-inch epoxy lined DIP stubouts for low-pressure sewer system connections including drop manhole piping, excavation, backfill, fittings, concrete blocking, plug, and accessories as specified or shown, complete in place and anchored for the sum of Dollars and Cents per each. $ $ 29 1 EA Furnish and install 8-inch DIP drop manhole piping including excavation, backfill, fittings, concrete blocking, plug, and accessories as specified or shown, complete in place and anchored for the sum of Dollars and Cents per each. $ 30 5700 LF Repair asphalt paved surfaces removed by trenching for main,laterals and service lines in accordance with the drawings and specifications, including backfill, compaction, concrete, asphalt, and accessories as specified or shown, complete in place for the sum of Dollars and Cents per linear foot. $ $ 31 6,300 LF Provide seeding and geotextile blanket in accordance with the drawings and specifications, complete in place and anchored for the sum of Dollars and Cents per linear foot. $ $ FAprojects\318132001Specs\Part B_AD1 Am B-10 ATTACHMENT 1-AD1 318-3200 Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 32 60 CY Type ""E" (1500 psi) concrete for miscellaneous placement, complete in place for the sum of Dollars and Cents per cubic yard. $ $ 33 60 CY Crushed limestone for miscellaneous placement, complete in place for the sum of Dollars and Cents per cubic yard. $ $ 34 40 CY Furnish and provide the rock riprap in accordance with the drawings and specifications, complete in place for the sum of Dollars and Cents per cubic yard. $ $ 35 34 EA Furnish and provide the clay collar on the sewer line in accordance with the drawings and specifications, complete in place for the sum of Dollars and Cents per square yard. $ $ 36 485 LF Furnish and provide concrete encasement of the sewer line in accordance with the drawings and specifications, complete in place for the sum of Dollars and Cents per linear foot. $ $ R\prolects\318\3200\Specs\PartB ADlAm B-11 ATTACHMENT 1-AD1 318-3200 Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 37 300 SY Furnish and install sod around service tap and over backfilled trenches located on managed or private lawns in accordance with the drawings and specifications, complete in place for . the sum of m Dollars and Cents per square yard. $ $ 38 500 SY Miscellaneous Asphalt Pavement Repair as directed by City for pavement not above trench, including base, asphalt, and accessories, in accordance with the drawings and specifications, complete in place for the sum of Dollars and Cents per square yard. $ $ 39 1 LS Mobilization, Bonds, and Demobilization, complete in place for the lump sum of Dollars and Cents. $ $ 40 1 LS For providing a pollution prevention system for stormwater discharge in accordance with the Specifications and the EPA regulations, and the assumption of the responsibility of said pollution prevention system, complete in place for the lump sum of Dollars and Cents. $ $ F:`projects\318\3200\Specs\Part B AD1.doc B-12 ATTACHMENT 1-AD1 318-3200 Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 41 13,000 LF For providing a trench excavation safety protection system in accordance with the Specifications and OSHA regulations, and the assumption of the responsibility of said protection system, z complete in place for the sum of Dollars and Cents per linear foot. $ TOTAL PROJECT BID: TOTAL AMOUNT BID FOR ITEMS (ITEMS 1-41) Dollars and Cents. $ Within ten days after acceptance of this Proposal,the undersigned will execute the formal contract and will deliver an approved Surety Bond and such other bonds as required by the Contract Documents,for the faithful performance of the Contract. The attached bid security in the amount of (5 percent) of the total amount bid is to become the property of the City of Fort Worth,Texas, in the event the contract and bonds are not executed and delivered within the time set forth,as liquidated damages for the delay and additional work caused thereby. The undersigned bidder certifies that he has been furnished at least one set of the General Contract Documents and General Specifications for Water Department Projects,dated July 21,2000,and all addenda thereto, and that he has read and thoroughly understands all the requirements and conditions of those General Documents and the Specific Contract Documents and appurtenant plans. F.\projecW18\3200\Specs\Part B AD1.doc B-13 ATTACHMENT 1-AD1 318-3200 The undersigned assures that its employees and applicants for employment and those of any labor organization, subcontractors, and employment agency in either furnishing or referring employee applicants to the undersigned are not discriminated against as prohibited by the terms of City Ordinance No. 7278 as amended by City Ordinance No. 7400. The bidder agrees to begin construction within 10 calendar days after issue of the work order. Construction shall be finally complete within 210 calendar days of issuance of work order. (Complete A or B below, as applicable:) A. The principal place of business of our company is in the State of Non-resident Bidders in the State of , our principal place of business are required to be percent lower than resident Bidders by state law. A copy of the statute is attached. Non-resident Bidders in the State of , our principal place of business are not required to underbid resident Bidders. _ B. The principal place of business of our company or our parent company or majority holder is in the State of Texas. The bidder understands that the ENGINEER and OWNER will evaluate the qualifications of the bidder to perform the specified project and that, although obtaining pre-qualification from the Fort Worth Water Department is necessary to bid the project, it does not guarantee a favorable recommendation of award of a construction contract for this project. P\proJects\318\3200\Specs\PartB ADi.doc B-14 ATTACHMENT 1-AD1 318-3200 ' Receipt is hereby acknowledged of the following addenda to the Contract Documents: Addendum No. 1 dated Received Addendum No. 2 dated Received Addendum No. 3 dated Received Addendum No. 4 dated Received .. Addendum No. 5 dated Received Respectfully submitted, Attested by: Signature Signature Printed Name and Title Printed Name and Title Company Name �. Mailing Address Street Address City and State Telephone Number Seal and Authorization kL (If Corporation) R\projecWl8\3200\Specs\PartB AD1.doc B-15 ATTACHMENT 1-ADI 318-3200 LAKE WORTH SOUTH SHORE GRAVITY SEWER SYSTEM CITY OF FORT WORTH Date/Time for Receiving Bids: 2:00 p.m. Thursday, September 18, 2003 PLANHOLDER'S LIST September 12, 2003 North Texas Construction Report& Plan Room S.J. Louis Construction Company 11325 Pegasus, S-233 West 520 South 6 th Avenue Dallas, Texas 75238 Mansfield, Texas 76063 (214)342-9200/Fax: (214) 342-9050 (817)477-0320/Fax: (817)477-0552 Ms. Linda Gant(6) Mr. Les Whitman (14) McGraw Hill Construction Dodge Plan Room Jackson Construction, LTD. 9155 Sterling Drive, Suite 160 5112 Sun Valley Drive Irving,Texas 75063 Fort Worth, Texas 76119 (972)819-1400/Fax: (972)819-1409 (817)572-3303/Fax: (817)478-0443 dw Ms. Dorothy Lorfing (7) Mr. Steve Haberstroh (15) Whitley&Siddons Ranier Company, Ltd. P.O. Box 461431 75046 222 West Exchange , Suite 203 1449 Lakeside Drive Fort Worth, Texas 76106 Garland, Texas 75042 (817)563-6288/Fax: (817) 563-6298 (972)487-0322/Fax: (972)487-8603 Mr. Scott Gentry(16) Ms.Valerie Henson (8) Holloman Corporation DFW Minority Business Council 1011 West Euless Blvd., Suite 240 1000 Tower South Euless, Texas 76040 2720 Stemmons Frwy. (817)283-3888/Fax: (817) 545-9935 Dallas, Texas 75207 Mr. Charles Brannon (17) (214)630-0747/Fax: (214)637-2241 Mr. Bill Hunter(9) Circle"C"Construction Company P.O. Box 40328 CMD/Associated General Contractors 500 W. Trammell -. 417 Fulton Fort Worth, Texas 76140 Fort Worth, Texas 76104 (817)293-1863/Fax: (817)293-1957 (817)882-9109/Fax: (817) 882-9163 Ms. Teri Skelly(18) Ms. Rachel Arts (10) MM Conaster Construction, Inc. Gin-Spen, Inc. P.O. Box 15804 780 W. Mansfield Hwy. 5327 Wichita Street Kennedale, Texas 76060 Fort Worth, Texas 76119 s (817)478-1119/Fax: (817)478-0899 (817)534-1743/Fax: (817) 534-4556 Mr. Doug Bisballe(11) Mr. Jerry Conaster(19) AUI Contractors, LP Tri-Tech Construction, Inc. 300 W. Ramsey 1133 E. Loop 820 South Fort Worth, Texas 76110 Fort Worth, Texas 76112 (817)926-4377/FAX: (817)926-4387 (817)496-5361/Fax: (817)446-3044 Ms. Jane Ratliff(12) Mr. Troy Woody(20) �- This list is furnished as a convenience only. Alan Plummer Associates, Inc. accepts no responsibility for its accuracy or completeness. F:\projects1318X3200\SpecsXPlanhldr Ist.doc 1 t 318-3200 LAKE WORTH SOUTH SHORE GRAVITY SEWER SYSTEM CITY OF FORT WORTH Date/Time for Receiving Bids: 2:00 p.m. Thursday, September 18, 2003 G PLANHOLDER'S LIST September 12, 2003 Texas Road and Utilities, Inc. P.O. Box 519 945 South Loop 4 Buda, Texas 78610 (512) 312-1166/Fax: (512) 312-1788 Mr. David Kallfelz(26) Hall Albert Construction Company 201 N.E. 29th Street Fort Worth, Texas 76106 (817)624-9391/Fax: (817)625-2941 Mr. Mike Plunk(27) Patco Utilities 1617 W. Pioneer Pkwy. Grand Prairie, Tx 75051 (972)641-7901/Fax; (972)641-8233 Mr. Darrell Hastings(28) This list is furnished as a convenience only. Alan Plummer Associates, Inc. accepts no responsibility for its accuracy or completeness. F:1projects131813200\,Specs\Planhldr Ist.doc 2 318-3200 ADDENDUM NO. 2 TO PLANS, SPECIFICATIONS, AND CONTRACT DOCUMENTS FOR CITY OF FORT WORTH LAKE WORTH SOUTH SHORE GRAVITY SEWER SYSTEM TO: PROSPECTIVE BIDDERS AND PLAN HOLDERS The Plans, Specifications and Contract Documents shall be modified as required by the following items: Item 2-1 Specifications, TABLE OF CONTENTS, PART E—TECHNICAL SPECIFICATIONS: Add the following to the Table of Contents: "02271 Rock Riprap". Item 2-2 Specifications, Section 02271 - ROCK RIPRAP: Add the attached Section 02271 (ATTACHMENT 1-AD2) to the specifications. All items in conflict with this addendum are hereby deleted. THIS ADDENDUM IS MADE PART OFTHE SPECIFICATIONS AND CONTRACT DOCUMENTS, AND SHALL BE ACKNOWLEDGED ON THE PROPOSAL AND ON THE BID ENVELOPE. ALAN PLUMMER ASSOCIATES, INC. ®"`o 4'q�`0�iF'rt1p ` y 1 ' e gyp:•' •.a , �............................... o JEFFREY E.CAFFEY Jeffrey E. Caffey, P.E. �........... .......... ......:.. September 16, 2003 'AEEi�StE�ER�� l,EMG F:\projects\318\3200\Specs\ADDENDUM_2.doc Addendum No. 2- Page 1 P0 318-3200 SECTION 02271 ROCK RIPRAP PART 1 - GENERAL 1.01 WORK INCLUDED A. Erosion protection of drainage channel side slopes including placement of: 1. Geotextile fabric; and 2. Filter blanket material; and 3. Stone riprap. 1.02 QUALITY ASSURANCE A. Standards and Applicable Specification: 1. ASTM C88: Test for Soundness of Aggregates by Use of Sodium Sulfate or Magnesium Sulfate. 2. ASTM C127: Test for Specific Gravity and Absorption of Coarse Aggregate. 3. ASTM C136:Test for Sieve or Screen Analysis of Fine and Coarse Aggregates. 4. ASTM C535:Test for Resistance to Abrasion of Large Size Coarse Aggregate by Use of the Los Angeles Machine. 5. ASTM D75: Sampling Aggregates. 1.03 SUBMITTALS A. Submittals shall be prepared and submitted in accordance with the Contract Documents. B. Submit Record Data on geotextile fabric, tests for filter blanket and riprap for compliance with specifications. 1.04 MATERIALS A. Sources and Evaluation for Compliance: 1. All material for filter blanket and riprap protection work shall be produced from approved sources, and tested for compliance with specification. 2. Tests to which the material may be subjected include specific gravity, adsorption, unit weight, Los Angeles Abrasion, soundness, freezing and thawing,wetting and drying,petrographic analysis,and such other tests as may be considered necessary to demonstrate the source will produce materials which are acceptable for use in the Work. �, F.VrojecWl8\3200\Specs\02271 AD2_DOC 02271-1 ATTACHMENT 1-AD2 318-3200 3. Tests may be conducted either by source supplying materials or an independent laboratory. The CONTRACTOR shall be responsible for all costs associated with compliance testing, all of which will be considered subsidiary to construction, and no separate measurement and payment will be made. 4. The CONTRACTOR shall furnish the OWNER with written certification from independent laboratory or supplier of material that riprap and filter blanket material comply with the conditions set forth in the specifications. C. Filter Blanket Material: 1. Composition: a. Composed of tough durable particles. b. Reasonably free from thin, flat and elongated pieces. C. Well graded between the prescribed limits as specified. . d. Contain no organic matter or soft, friable particles in quantities greater than 1 percent by weight. 2. Material shall meet the following specific requirements: a. Resistance to Abrasion: Maximum percentage of wear shall be 40 after 1,000 revolutions, as determined by ASTM C 535, Grading 1. b. Soundness: Maximum loss shall be 25 percent weighted average at 5 cycles when tested for soundness in compliance with ASTM C88. C. Gradation: Filter Blanket Sieve Size Percent Passing or No. By Weight 8" 100 6" 93-100 4" 83-98 2" 63-80 3/4" 35-55 No. 4 2-5 No. 10 0-10 d. In addition, the right is reserved to perform such other tests as may be considered necessary to determine the acceptability of the material. Additional testing as required will be at the expense of the OWNER. In the event the materials fail to meet the requirements specified,the tests shall be at the expense of the CONTRACTOR. e. Install filter blanket material to a 6-inch minimum thickness, unless otherwise noted. D. Riprap Stone: 1. Composition: a. Durable and of such quality to insure permanence in the structure and in the climate in which it is to be used. ,M F.\projecfs\318\3200\Specs\02271 AD2.DOC 02271-2 ATTACHMENT 1-AD2 318-3200 b. Free from cracks,seams and other defects which would tend to increase unduly its deterioration from natural causes. C. Reasonably well graded within the specified limits. 2. Material shall meet the following specific requirements: a. Weight: The weight shall be 165 pounds per solid cubic foot minimum calculated from the bulk specific gravity (saturated surface dry) of the sample, determined in compliance with the procedure in ASTM C127. b. Resistance to Abrasion: The maximum percentage of wear shall be 40 after 1000 revolutions as determined by ASTM C 535, Grading 1. C. Soundness: Maximum loss shall be 25 percent weighted average at five cycles when tested for soundness in compliance with ASTM C 88, using particles passing a 2-1/2 inch sieve and retained on a 1-1/2 inch sieve. After final drying the material shall be screened over a 1-1/4 inch sieve. d. Gradation: 1) Type 1: Install piping to a 36-inch minimum thickness using the following graded stone: 36-inch Riprap Sieve Size Percent Passing �. or No. By Weight 44" 100 36" 95-100 30" 45-70 24" 15-40 18" 5-20 12" 0-10 2) Type 2: Install riprap to an 18-inch minimum thickness using the following graded stone: 18-inch Riprap Sieve Size Percent Passing or No. By Weight 24" 65-100 18" 55-75 12" 15-40 8" 5-20 6" 0- 10 3) Shake and wash sample through sieves. _ e. Shape: Neither the breadth nor the thickness of any piece of riprap shall be less than one-third of its length. Stones shall be angular in shape. �, P\projectWl8\3200\specs\02271 AD2.DOC 02271-3 ATTACHMENT 1-AD2 318-3200 E. GEOTEXTILE FABRIC 1. The geotextile fabric shall be inert to commonly encountered chemicals, hydrocarbons, mildew and rot resistant, resistant to ultraviolet light exposure, insect and rodent resistant,and conform to the properties in the following table. Average Roll Minimum Value Physical Properties (Weakest Principal Direction* Grab Tensile Strength* 200 ASTM D-4632 (Lbs.) Elongation at Failure* 60 ASTM D-4632 (%) Mullen Burst Strength 320 ASTM D-3786 (psi) Average Roll Minimum Value Physical Properties (Weakest Principal Direction)* Water Flow Rate 100 (gal/mints ASTM D-4491 AOS(095) mm, ASTM D-4751 0.3 Trapezoid Tear Strength* 60 ASTM D-4533 (Lbs.) Permeability- k 0.1 (cm/sec) ASTM D-4491 Puncture Resistance 80 ASTM D-4833 (modified) (Lbs.) 2. The average roll minimum value (weakest principal direction) for strength properties of any individual roll tested from the manufacturing lot or lots of a particular shipment shall be in excess of the average roll minimum value (weakest principal direction) stipulated herein. F. Cost of Testing: Testing as required will be at the expense of the CONTRACTOR. F.\projecM318\3200\Specs\02271 AD2.DOC 02271-4 ATTACHMENT 1-AD2 318-3200 WE PART 2- PRODUCTS 2.01 COMPOSITION A. Geotextile shall be non-woven fabric consisting only of continuous chain polymer filaments or yarns of polyester, formed into a stable network by needle punching. Acceptable Products and Manufacturers: 1. Trivera- 1125 2. Auline - Q80 3. Polyfilter- FX80NW B. Stone for riprap shall be durable stone. Filter blanket material shall be crushed, angular stone approved for riprap or filter blanket material. Riprap and filter blanket material shall meet the specified gradations. PART 3- EXECUTION 3.01 PREPARATION OF FOUNDATION A. Trim and dress areas on which the filter blanket layers or geotextile fabric are to be placed. ! B. Immediately prior to placing the geotextile fabric or filter blanket,the prepared base will be inspected and no material shall be placed thereon until that area meets the requirements of these Specifications and is approved by the OWNER. C. No additional payment will be made for preparation of foundation, but will be considered subsidiary to placement of the riprap. 3.02 RIPRAP STONE PLACEMENT A. Place 24-inch minimum thickness riprap unless otherwise shown on the plans,on top of filter blanket or geotextile fabric and within the limits indicated on the Drawings or as directed by the OWNER. B. Place rock riprap on the filter blanket layers or geotextile fabric in such manner as to produce a well-graded mass of rock with the minimum practical percentage of voids. C. Construct toe on sides of riprap as shown on the Plans. Toe shall have a minimum width and depth of 2 times the minimum riprap thickness, or as shown on the plans. D. Construct within the specified tolerance to the lines and grades indicated on the Drawings or staked in the field. 1. A tolerance of plus 9 inches or minus 3 inches from the slope line and grades indicated on the Drawings will be allowed in the finished surface of the riprap in an area not exceeding 1,000 square feet. Such areas shall not be contiguous. 2. Place riprap to its full course thickness in one operation and in such manner as to avoid displacing filter blanket material. i FAprojects\,318\3200\Spec8\02271_AD2.D0C 02271-5 ATTACHMENT 1-AD2 318-3200 3. The larger stones shall be well distributed and the entire mass of stones in their final position shall comply with the gradation specified. The finished riprap shall be free from objectionable pockets of small stones and clusters of larger stones. 4. Placing riprap in layers will not be permitted. 5. Placing riprap by dumping into chutes,dumping from top of slope,pushing from top of slope, or by methods likely to cause segregation of the various sizes will not be permitted. 6. Obtain specified distribution of the various sizes of stones throughout the mass by selective loading of the material at the quarry or other source, or by other methods of placement which will produce the specified results. 7. Rearranging of individual stones by mechanical equipment or by hand will be required to the extent necessary to obtain a reasonably well graded distribution of stone sizes as specified above. 8. Maintain riprap protection until accepted and replace material displaced by any cause to the lines and grades indicated on the Drawings at no additional cost to the OWNER. 9. Finished surface of riprap shall not extend above preconstruction grade (contour) except in areas where riprap is placed in eroded areas. E. Riprap shall be furnished and installed in the locations designated on the drawings and/or as otherwise directed by the OWNER. F. Any changes and/or alternations will be performed as set forth in the Contract Documents. 3.03 FILTER BLANKET PLACEMENT A. Place 6-inch thick minimum filter blanket layer unless otherwise shown on drawings, under riprap and within the limits indicated on the Drawings or as staked in the field. B. Spread filter blanket material uniformly on the prepared base to the slope lines and grades indicated on the Drawings, or as directed. 1. Placing of material by dumping from top of slope or by other methods which will tend to segregate particle sizes within the layers will not be permitted. 2. Repair damage to the surface of the filter blanket base during placing of the filter blanket before proceeding with the work. 3. Compaction of the filter blanket layers will not be required but shall be finished to present a reasonably even surface free from mounds or windows. 4. A tolerance of plus 2 inches or minus 1 inch will be allowed. C. No additional payment will be made for furnishing and installing the filter blanket material, but will be considered subsidiary to placement of the rock riprap. 3.04 GEOTEXTILE FABRIC PLACEMENT A. Install the geotextile fabric under the rock riprap as shown on plans. Construction vehicles will not be allowed to traffic directly on the fabric or filter blanket. Overlaps when necessary shall be 36 inches minimum. Use securing pins when necessary to insure proper anchoring of the fabric, with securing pins spaced at 5 to 10 foot F:\projects4318\3200\Specs\02271 AD2.DOc 02271-6 ATTACHMENT 1-AD2 318-3200 centers. Securing pins shall be 3/16 inch steel bars, pointed at one end and fabricated with a head to retain a steel washer having an outside diameter of not less than 1-1/2 inches. The pin length shall not be less than 18 inches. U-shaped pins or special staples shall be an acceptable option, if approved by the Engineer. B. Place the riprap onto the fabric maintaining design aggregate thickness at all times. .� Avoid over-stressing the soil by utilizing equipment in spreading and dumping that exerts only moderate pressures on the soil. Severe rutting at the time of placement is an indication of over-stressing the soil. Such soil over-stressing must be avoided. Increasing aggregate depths and reducing loads are two methods of reducing pressures on the soil. Fill any ruts which develop during spreading or compacting with additional aggregate rather than blading from surrounding areas. C. No additional payment will be made for furnishing and installing the geotextile fabric, but will be considered subsidiary to placement of the rock riprap. END OF SECTION _, P\projects\318\3200\Specs\02271_AD2.D0C 02271-7 ATTACHMENT 1-AD2 16 TRANSMISSION FORM Date: September 16,2003 ASSOCLATES,INC. Time: 2:00 R.M. ENVIRONMENTAL ENGINEERS.DESIGNERS.SCIENTISTS Job No.: 318-3200 TO: Company: Address: City: Phone: Fax: FROM: Jeff Caffey 7524 Mosier View Court- Suite 200-Fort Worth, Texas 76118-7110 Phone 817-284-2724-Metro 817-589-2226-Fax Metro 817-589-0072 NO. PGS. 9 (Including cover) COMMENTS: ATTACHED IS ADDENDUM NO. 2 FOR THE LAKE WORTH SOUTH SHORE GRAVITY SEWER SYSTEM, WATER DEPARTMENT PROJECT NO. P171-070171131150. PLEASE ACKNOWLEDGE RECEIPT OF THIS ADDENDUM BY SIGNING BELOW AND RETURNING THIS COVER SHEET ONLY (BY FAX) TO ALAN PLUMMER ASSOCIATES' OFFICE AT 817-589-0072. THANK YOU. Planholder's Signature/Acknowledgement CIP F. . " to 318-3200 ADDENDUM NO. 3 TO PLANS, SPECIFICATIONS, AND CONTRACT DOCUMENTS FOR CITY OF FORT WORTH LAKE WORTH SOUTH SHORE GRAVITY SEWER SYSTEM TO: PROSPECTIVE BIDDERS AND PLAN HOLDERS The Plans, Specifications and Contract Documents shall be modified as required by the following items: Item 3-1 Specifications, PART A- NOTICE TO BIDDERS: - Change Bid Date from "2:00 PM, September 18, 2003"to "2:00 PM, October 2, 2003." Item 3-2 Specifications, PART B - PROPOSAL, MINORITY AND WOMEN ENTERPRISES SPECIFICATIONS: Delete the "Special Instructions for Bidders" in its entirety and replace with the attached "Special Instructions for Bidders" (ATTACHMENT 1-AD3). Delete the "Subcontractors/Suppliers Utilization Form" in its entirety and replace with the attached "Schedule of Subcontractors/Suppliers" (ATTACHMENT 2-AD3). Delete the "Prime Contractor Waiver Form" in its entirety and replace with the attached "Prime Contractor Waiver" (ATTACHMENT 3-AD3). Delete the"Good Faith Effort Form"in its entirety and replace with the attached "Good Faith Effort" (ATTACHMENT 4-AD3). Delete the"Joint Venture Eligibility Form"in its entirety and replace with the attached "Joint Venture Eligibility Form" (ATTACHMENT 5-AD3). ,� F:�proiec WI8�32o0\SpecsIADDENDUM 3.doc Addendum No. 3 - Page 1 318-3200 All items in conflict with this addendum are hereby deleted. THIS ADDENDUM IS MADE PART OF THE SPECIFICATIONS AND CONTRACT DOCUMENTS, AND SHALL BE ACKNOWLEDGED ON THE PROPOSAL AND ON THE BID ENVELOPE. ALAN PLUMMER ASSOCIATES, INC. �•'�E OF gp. Jeffrey E. Caffey, P.E. • :' September 16, 2003 E.CA. Y..� age EQ#STET!xG1+V. F:\projects\318\3200\Specs\ADDENDUM_3.doc Addendum No. 3 - Page 2 F-OR: :, TH City of Fort Worth Minority and Women Business Enterprise Specifications SPECIAL INSTRUCTIONS FOR BIDDERS APPLICATION OF POLICY If the total dollar value of the contract is$25,000 or more,the M/WBE goal is applicable. If the total dollar value of the contract is less than$25,000,the M/WBE goal is not applicable. POLICY STATEMENT It is the policy of the City of Fort Worth to ensure the full and equitable participation by Minority and Women Business Enterprises (M/WBE) in the procurement of all goods and services to the City on a contractual basis. All requirements and regulations stated in the City's current Minority and Women Business Enterprise Ordinance apply to this bid. M/WBE PROJECT GOALS The City's MBE/WBE goal on this project is_IT_%of the base bid value of the contract. COMPLIANCE TO BID SPECIFICATIONS On City contracts of$25,000 or more, bidders are required to comply with the intent of the City's M/WBE Ordinance by either of the following: 1. Meet or exceed the above stated M/WBE goal,or 2. Good Faith Effort documentation,or; - 3. Waiver documentation,or; 4. Joint Venture. SUBMITTAL OF REQUIRED DOCUMENTATION The applicable documents must be received by the Managing Department,within the following times allocated,in order for the entire bid to be considered responsive to the specifications. 1. Subcontractor Utilization Form, if goal is received by 5:00 p.m., five (5) City business days after the bid met or exceeded: opening date,exclusive of the bid opening date. 2. Good Faith Effort and Subcontractor received by 5:00 p.m., five (5) City business days after the bid Utilization Form, if participation is less than opening date,exclusive of the bid opening date. statedgoal: 3. Good Faith Effort and Subcontractor received by 5:00 p.m., five (5) City business days after the bid Utilization Form, if no M/WBEparticipation: opening date,exclusive of the bid opening date. 4. Prime Contractor Waiver Form, if you will received by 5:00 p.m., five (5) City business days after the bid perform all subcontracting/supplier work: opening date,exclusive of the bid opening date. 5. Joint Venture Form,if utilize a joint venture received by 5:00 p.m., five (5) City business days after the bid to met or exceed goal. opening date, exclusive of the bid opening date. FAILURE TO COMPLY WITH THE CITY'S M/WBE ORDINANCE,WILL RESULT IN THE BID BEING CONSIDERED NON-RESPONSIVE TO SPECIFICATIONS Any questions, please contact the M/WBE Office at(817)871-6104. Rev,5/30/03 ATTACHMENTI-AD3 ATTACHMENT IA Page 1 of 4 FORT WORTH City of Fort Worth Subcontractors/Suppliers Utilization Form PRIME COMPANY NAME: Check applicable block to describe prime PROJECT NAME: MNV/DBE NON-M/W/DBE BID DATE Lake Worth South Shore Gravity Sewer System City's M/WBE Project Goal: Prime's M/WBE Project Utilization: PROJECT NUMBER 17% % P171-070171131150 Identify all subcontractors/suppliers you will use on this project Failure to complete this form, in its entirety with requested documentation, and received by the Managing Department on or before 5:00 p.m. five (5) City business days after bid opening, exclusive of bid opening date, will result in the bid being considered non-responsive to bid specifications. The undersigned Offeror agrees to enter into a formal agreement with the M/WBE firm(s) listed in this utilization schedule, conditioned upon execution of a contract with the City of Fort Worth. The intentional and/or knowing misrepresentation of facts is grounds for consideration of disqualification and will result in the bid being considered non-responsive to bid specifications �- M/WBEs listed toward meeting the project goal must be located in the nine (9) county marketplace or currently doing business in the marketplace at the time of bid. Marketplace is the geographic area of Tarrant, Parker,Johnson, Collin, Dallas, Denton, Ellis, Kaufman and Rockwall counties. Identify each Tier level. Tier is the level of subcontracting below the prime contractor, i.e., a direct payment from the prime contractor to a subcontractor is considered 1"tier, a payment by a subcontractor to its supplier is considered 2"d tier ALL M/WBEs MUST BE CERTIFIED BEFORE CONTRACT AWARD. Certification means those firms, located or doing business at the time of bid opening within the Marketplace,that have been determined to be bonafide minority or women businesses by the North Central Texas Regional Certification Agency (NCTRCA), or the Texas Department of Transportation (TX DOT), highway division. Disadvantaged Business Enterprise(DBE) is synonymous with Minority/Women Business Enterprise (M/WBE). If hauling services are utilized, the prime will be given credit as long as the MMBE listed owns and operates at least one fully licensed and operational truck to be used on the contract. The M/WBE may lease trucks from another M/WBE firm, including M/WBE owner-operators, and receive full M/WBE credit. The MMBE may lease trucks from non-M/WBEs, including owner-operators, but will only receive credit for the Fees and commissions earned by the M/WBE as outlined in the lease agreement. '� ATTACHMENT 2-AD3 Rev.5/30/03 ATTACHMENT IA F'-O'RRTyWORTH Page 3 of 4 i Primes are required to identify ALL subcontractors/suppliers,regardless of status;i.e.,Minority,Women and non-M/WBEs. Please list M/WBE firms first,use additional sheets if necessary. Certification (check one) C SUBCONTRACTOR/SUPPLIER T r Company Name I N T Detail Detail Address M W C X P Subcontracting Work Supplies Purchased Dollar Amount T D Telephone/Fax r B B R 0 E E E C T E A Rev.5/30/03 ATTACHMENT2-AD3 ATTACHMENT 1 B F4 RT Wo RT H Page 1 of 1 v— City of Fort Worth Prime Contractor Waiver Form PRIME COMPANY NAME: Check applicable block to describe rime PROJECT NAME: MM/DBE NON-M/W/DBE BID DATE Lake Worth South Shore Gravity Sewer City's M/WBE Project Goal: PROJECT NUMBER 17% P171-070171131150 If both answers to this form are YES, do not complete ATTACHMENT 1C(Good Faith Effort Form). All questions on this form must be completed and a detailed explanation provided, if applicable. If the answer to either question is NO,then you must complete ATTACHMENT 1 C. This form is only applicable if both answers are yes. Failure.to complete this form in its entirety and be.received by the Managing:Department on or before`5c00 p m.,ffve(a)City business days after bid opening,exclusive of the bid opening date,will result in the bid being considered non-responsive to bid specifications. Will you perform this entire contract without subcontractors? YES If yes, please provide a detailed explanation that proves based on the size and scope of this project, NO this is your normal business practice and provide an operational profile of your business. Will you perform this entire contract without suppliers? YES If yes, please provide a detailed explanation that proves based on the size and scope of this project, this is your normal business practice and provide an inventory profile of your business. NO The bidder further agrees to provide, directly to the City upon request, complete and accurate information regarding actual work performed by all subcontractors, including M/WBE(s)on this contract,the payment therefore and any proposed changes to the original M/WBE(s) arrangements submitted with this bid. The bidder also agrees to allow an audit and/or examination of any books, records and files held by their company that will substantiate the actual work performed by the M/WBEs on this contract, by an authorized officer or employee of the City. Any intentional and/or knowing misrepresentation of facts will be grounds for terminating the contract or debarment from City work for a period of not less than three (3)years and for initiating action under Federal, State or Local laws concerning false statements. Any failure to comply with this ordinance creates a material breach of contract may result in a determination of an irresponsible offeror and barred from participating in City work for a period of time not less than one (1)year. Authorized Signature Printed Signature Title Contact Name(if different) Company Name Phone Number Fax Number Address Email Address City/State/Zip Date Rev.5/30/03 ATTACHMENT 3-AD3 ATTACHMENT IC Page 1 of 3 " FORT WORTH ---�•, City of Fort Worth Good Faith Effort Form PRIME COMPANY NAME: Check applicable block to describe rime PROJECT NAME: M/W/DBE NON-MIW/DBE Lake Worth South Shore Gravity Sewer System BID DATE City's M/WBE Project Goal: PROJECT NUMBER 17% P171-070171131150 If you have failed to secure M/WBE participation and you have subcontracting and/or supplier opportunities or if your DBE participation is less than the City's project goal,you must complete this form. If the bidder's method of compliance with the M/WBE goal is based upon demonstration of a "good faith effort", the bidder will have the burden of correctly and accurately preparing and submitting the documentation required by the City. Compliance with each item, 1 thru 6 below, shall satisfy the Good Faith Effort requirement absent proof of fraud, intentional and/or knowing misrepresentation the facts or intentional discrimination by the bidder. Failure to complete this form, in its entirety .with supporting documentation, and received by the Managing Department on or before 5:00 p.m.five(5)City business days after bid opening,exclusive of bid opening date,will result in the bid being considered non-responsive to bid specifications. 1.) Please list each and every subcontracting and/or supplier opportunity) for the completion of this project, regardless of whether it is to be provided by a M/WBE or non-M/WBE. (DO NOT LIST NAMES OF FIRMS) On Combined Projects, list each subcontracting and or supplier opportunity through the 2ndtier. (Use additional sheets, if necessary) List of Subcontracting Opportunities List of Supplier Opportunities ATTACHMENT 4-AD3 Rev.05/30/03 ATTACHMENT I Page 3 of 3 ADDITIONAL INFORMATION: Please provide additional information you feel will further explain your good and honest efforts to obtain M/WBE participation on this project. The bidder further agrees to provide, directly to the City upon request, complete and accurate information regarding actual work performed on this contract, the payment thereof and any proposed changes to the original arrangements submitted with this bid. The bidder also agrees to allow an audit and/or examination of any books, records and files held by their company that will substantiate the actual work performed on this contract, by an authorized officer or employee of the City. Any intentional and/or knowing misrepresentation of facts will be grounds for terminating the contract or debarment from City work for a period of not less than three (3) years and for initiating action under Federal, State or Local laws concerning false statements. Any failure to comply with this ordinance and creates a material breach of contract may result in a determination of an irresponsible offeror and barred from participating in City work for a period of time not less than one (1) year. The undersigned certifies that the information provided and the M/WBE(s) listed was/were contacted in good faith. It is understood that any M/WBE(s) listed in Attachment 1 C will be contacted and the reasons for not using them will be verified by the City's M/WBE Office. Authorized Signature Printed Signature Title Contact Name and Title(if different) Company Name Phone Number Fax Number Address Email Address City/State/Zip Date ATTACHMENT 4-AD3 Rev.05/30/03 Joint Venture Page 1 of 3 FOORT NORTH CITY OF FORT WORTH ,point Venture Eligibility Form All questions must be answered;use"NA"if applicable. Name of City project: A joint venture form must be completed on each project RFP/Bid/Purchasing Number: 1.Joint venture information: Joint Venture Name: Joint Venture Address: (If applicable) Telephone: Facsimile: E-mail address: Cellular: Identify the firms that comprise the joint venture: Please attach extra sheets if additional space is required to provide detailed explanations of work to be performed by each firm comprising the joint venture M/WBE firmNon-M/WBE name: T firm name: Business Address: Business Address: City,State,Zip: City,State,Zip: Telephone Facsimile E-mail Telephone Facsimile Cellular Cellular Certification Status: E-mail address Name of Certifying Agency: r f � 2.Scope of work performed by the Joint Venture: Describe the scope of work of the M/WBE: Describe the scope of work of the non-M/WBE: ATTACHMENT 5—AD3 Rev.5/30/03 on Joint Venture Page 3 of 3 AFFIDAVIT The undersigned affirms that the foregoing statements are true and correct and include all material information necessary to identify and explain the terms and operation of the joint venture. Furthermore, the undersigned shall agree to provide to the joint venture the stated scope of work, decision-making responsibilities and payments herein. The City also reserves the right to request any additional information deemed necessary to determine if the joint venture is eligible. Failure to cooperate and/or provide requested information within the time specified is grounds for termination of the eligibility process. The undersigned agree to permit audits, interviews with owners and examination of the books, records and files of the joint venture by any authorized representatives of the City of Fort Worth. Failure to comply with this provision shall result in the termination of any contract, which may be awarded under the provisions of this joint venture's eligibility and may initiate action under Federal, State and/or Local laws/ordinances concerning false statements or willful misrepresentation of facts. --— ------------------ ------------------------------------------- -- —-- ---- Name of M/WBE firm Name of non-M/WBE firm Printed Name of Owner Printed Name of Owner Signature of Owner Signature of Owner Printed Name of Owner Printed Name of Owner Signature of Owner Signature of Owner Title Title Date Date Notarization State of County of On this day of ,20 ,before me appeared and to me personally known and who, being duly sworn,did execute the foregoing affidavit and did state that they were properly authorized to execute this affidavit and did so as their free act and deed. Notary Public Print Name Notary Public Signature Commission Expires (Sean ATTACHMENT 5-AD3 Rev.5/30/03 318-3200 LAKE WORTH SOUTH SHORE GRAVITY SEWER SYSTEM CITY OF FORT WORTH Date/Time for Receiving Bids: 2:00 p.m. Thursday, October 2, 2003 PLANHOLDER'S LIST September 26, 2003 North Texas Construction Report& Plan Room S.J. Louis Construction Company 11325 Pegasus, S-233 West 520 South 6 th Avenue Dallas, Texas 75238 Mansfield, Texas 76063 (214) 342-9200/Fax: (214) 342-9050 (817)477-0320/Fax: (817)477-0552 Ms. Linda Gant(6) Mr. Les Whitman (14) McGraw Hill Construction Dodge Plan Room Jackson Construction, LTD. 9155 Sterling Street, Suite 160 5112 Sun Valley Drive Irving, Texas 75063 Fort Worth, Texas 76119 (972) 819-1400/Fax: (972) 819-1409 (817) 572-3303/Fax: (817)478-0443 Ms. Dorothy Lorfing (7) Mr. Steve Haberstroh (15) Whitley&Siddons Ranier Company, Ltd. P.O. Box 461431 75046 222 West Exchange , Suite 203 1449 Lakeside Drive Fort Worth, Texas 76106 Garland, Texas 75042 (817) 563-6288/Fax: (817) 563-6298 (972)487-0322/Fax: (972)487-8603 Mr. Scott Gentry(16) Ms. Valerie Henson (8) Holloman Corporation DFW Minority Business Council 1011 West Euless Blvd., Suite 240 1000 Tower South Euless, Texas 76040 2720 Stemmons Frwy. (817)283-3888/Fax: (817)545-9935 Dallas, Texas 75207 Mr. Charles Brannon (17) (214)630-0747/Fax: (214)637-2241 Mr. Bill Hunter(9) Circle"C"Construction Company P.O. Box 40328 CMD/Associated General Contractors 500 W. Trammell 417 Fulton Fort Worth, Texas 76140 '►'` Fort Worth, Texas 76104 (817)293-1863/Fax: (817)293-1957 (817) 882-9109/Fax: (817) 882-9163 Ms. Teri Skelly(18) Ms. Rachel Arts(10) Conaster Construction, Inc. Gin-Seen, Inc. P.O. Box 15804 780 W. Mansfield Hwy. 5327 Wichita Street Kennedale, Texas 76060 Fort Worth, Texas 76119 (817)478-1119/Fax: (817)483-0899 (817) 534-1743/Fax: (817)534-4556 Mr. Doug Bisballe (11) Mr. Jerry Conaster(19) AUI Contractors, LP Tri-Tech Construction, Inc. 300 W. Ramsey 1133 E. Loop 820 South Fort Worth, Texas 76110 Fort Worth, Texas 76112 (817) 926-4377/FAX: (817)926-4387 (817)496-5361/Fax: (817)446-3044 Ms. Jane Ratliff(12) Mr.Troy Woody(20) This list is furnished as a convenience only. Alan Plummer Associates, Inc. accepts no responsibility for its accuracy or completeness. F:\projects\318\3200\Spem\Planhldr Ist_doc 1 318-3200 LAKE WORTH SOUTH SHORE GRAVITY SEWER SYSTEM CITY OF FORT WORTH Date/Time for Receiving Bids: 2:00 p.m. Thursday, October 2, 2003 PLANHOLDER'S LIST September 26, 2003 Texas Road and Utilities, Inc. P.O. Box 519 945 South Loop 4 Buda, Texas 78610 (512) 312-1166/Fax: (512) 312-1788 Mr. David Kallfelz(26) Hall Albert Construction Company 201 N.E. 29th Street Fort Worth, Texas 76106 (817)624-9391/Fax: (817) 625-2941 Mr. Mike Plunk (27) Patco Utilities 1617 W. Pioneer Pkwy. Grand Prairie, Tx 75051 (972)641-7901/Fax: (972)641-8233 Mr. Darrell Hastings(28) Bowles Construction Company 1634 Eastside Wichita Falls,Texas 76301 (940) 766-3518/Fax: (940) 766-3564 Mr. Jim Loving (29) Brett Construction Company, Inc. 616 Cedar Street Hico, Texas 76457 (254)796-4817/Fax: (254) 796-4823 Mr. Rick Stringer(30) This list is furnished as a convenience only. Alan Plummer Associates, Inc. accepts no responsibility for its accuracy or completeness. F:\projects\318\3200\Specs\Planhidr—Ist.doc 2 318-3200 ADDENDUM NO. 4 TO PLANS, SPECIFICATIONS, AND CONTRACT DOCUMENTS FOR CITY OF FORT WORTH LAKE WORTH SOUTH SHORE GRAVITY SEWER SYSTEM TO: PROSPECTIVE BIDDERS AND PLAN HOLDERS The Plans, Specifications and Contract Documents shall be modified as required by the following items: Item 4-1 Addendum No. 1, Item 1-1, Specifications, PART B—PROPOSAL: Delete in its entirety and replace with the attached revised PROPOSAL(Attachment 1-AD4). Item 4-2 Specifications, PART DA—ADDITIONAL SPECIAL CONDITIONS: Add the attached ADDITIONAL SPECIAL CONDITIONS (Attachment 2-AD4). Item 4-3 Plans, Sheet C-901, TYPICAL PRECAST MANHOLE: Add the following note: "4-INCH DIP STUB OUTS FOR FUTURE LOW-PRESSURE SEWER TIE-INS SHALL BE PE X MJ WITH A WALL RING AND AN MJ CAP." All items in conflict with this addendum are hereby deleted. THIS ADDENDUM IS MADE PART OF THE SPECIFICATIONS AND CONTRACT DOCUMENTS, AND SHALL BE ACKNOWLEDGED ON THE PROPOSAL AND ON THE BID ENVELOPE. ALAN PLUMMER ASSOCIATES, INC. _ �$PSA tE el r! ........................ / ..e.... .................Y .. Jeffrey E. Caffey, P.E. 89898 :tee September 25, 2003 If/ pw0E cis F.W49cW318W44\.8pem\Qrav1tyLJnW=DENDUM 4.doc Addendum No. 4 - Page 1 318-3200 PART B -PROPOSAL TO: Mr. Gary Jackson FROM: (Bidder's Name) City Manager Fort Worth, Texas (Address) PROPOSAL FOR: furnishing of all materials and equipment and labor and all necessary appurtenances and incidental work to provide a complete and operable project designated as: Lake Worth South Shore Gravity Sewer System Water Dept. Project No. P171-070171131150 Pursuant to the foregoing"Notice to Bidders,"the undersigned has thoroughly examined the Plans, Specifications,and the site, understands the amount of work to be done and hereby proposes to do all the work and furnish all labor,equipment,and materials necessary to fully complete the work as provided in the Plans and Specifications,and subject to the inspection and approval of the Director, Depart of Engineering of the City of Fort Worth. Upon acceptance of this proposal, the bidder is bound to execute a contract and furnish Performance and Payment Bond approved by the City of Fort Worth for performing and completing the said work within the time stated and for the following sum,to-wit: do F.Vtolectt318132QQ \gravity UrKAPan B AD4Abc B-1 Attachment 1 -AD4 318-3200 Lake Worth South Shore Gravity Sewer System Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 1 54 EA Furnish and install standard 4-foot diameter, 6-foot deep concrete manholes, complete in place for the sum of Dollars and Cents per each. $ $ 2 287 VF Extra depth for standard 4-foot diameter manhole greater than 6 feet, complete in place for the sum of Dollars and Cents per vertical foot. $ $ 3 2 EA Furnish and install standard 4-foot diameter shallow concrete manhole, complete in place for the sum of_ Dollars and Cents per each. $ $ 4 40 VF Coat interior manhole surfaces, complete in place for the sum of Dollars and Cents per vertical foot of manhole depth. $ $ 5 5 EA Furnish and install sweet street air filters in manholes, complete in place for the sum of Dollars and Cents per each. $ $ 6 1,574 LF Furnish and install 8-inch SDR 26 PVC sewer pipe (all depths), complete in place for the sum of Dollars and Cents per linear foot. $ $ r FAproiects\318\3200\Specs\Gravity Line\Part B_AD4.doc B-2 ATTACHMENT 1-AD4 318-3200 Lake Worth South Shore Gravity Sewer System Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 7 2,362 LF Furnish and install 10-inch SDR 26 PVC sewer pipe (all depths),complete in place for the sum of Dollars and Cents per linear foot. $ $ 8 6,831 LF Furnish and install 12-inch SDR 26 PVC sewer pipe (all depths),complete in place for the sum of Dollars and Cents per linear foot. $ $ 9 1,570 LF Furnish and install 4-inch PVC service line from sanitary sewer main to property line, complete in place for the sum of Dollars and Cents per linear foot. $ $ 10 750 LF Furnish and install 4-inch DIP sanitary sewer at locations where service line crosses existing water line,complete in place for the sum of Dollars and Cents per linear foot. $ $ 11 77 EA Install 4-inch tap on sanitary sewer main, complete in place for the sum of Dollars and Cents per each. $ $ 12 40 LF Furnish and install a 6-inch PVC service line from manhole to property line at Castle property, complete in place for the sum of Dollars and Cents per linear foot. $ $ W. F.\prolects\318\3200\Specs\Gravity Line\Part B AD4.doc B-3 ATTACHMENT 1-AD4 318-3200 Lake Worth South Shore Gravity Sewer System Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 13 3 EA Furnish and install 4-inch epoxy lined DIP stubouts for low-pressure sewer system connections,complete in place and anchored for the sum of Dollars and Cents per each. 14 1 EA Furnish and install 8-inch DIP drop manhole piping, complete in place and anchored for the sum of Dollars and Cents per each. $ $ 15 5,700 LF Permanent asphalt pavement repair per Sheet C-902, Standard Detail Typical Trench with Asphalt Cut, complete in place for the sum of Dollars and Cents per linear foot. $ $ 16 6,300 LF Provide seeding and geotextile blanket, complete in place and anchored for the sum of Dollars and Cents per linear foot. $ $ 17 10 CY Type "E" (1500 psi) concrete for miscellaneous placement,complete in place for the sum of w Dollars and Cents per cubic yard. $ F:\projects\318\3200\Specs\Gravity UneTart B_AD4.doc B-4 ATTACHMENT 1-AD4 ,. 318-3200 Lake Worth South Shore Gravity Sewer System Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 18 10 CY Crushed limestone for miscellaneous placement, complete in place for the sum of Dollars and Cents per cubic yard. $ $ 19 40 CY Furnish and provide the rock riprap, complete in place for the sum of Dollars and Cents per cubic yard. $ $ 20 34 EA Furnish and provide the clay collar on the sewer line, complete in place for the sum of Dollars and Cents per each. $ $ 21 485 LF Furnish and provide concrete encasement, complete in place for the sum of Dollars and Cents per linear foot. $ $ 22 300 SY Furnish and install sod around service tap and over backfilled trenches located on managed or private lawns, complete in place for the sum of Dollars and Cents per square yard. $ R\projects\316\3200\Specs\Gravity Line\Part B AD4.doc B-5 ATTACHMENT 1-AD4 318-3200 Lake Worth South Shore Gravity Sewer System Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 23 120 CY Miscellaneous Asphalt Pavement Repair as directed by City for pavement not above trench, complete in place for the sum of Dollars and Cents per cubic yard. $ $ 24 56 EA Vacuum test manhole for the lump sum of Dollars and Cents per each. $ $ 25 77 EA Two-way service clean-out, complete in place for the sum of Dollars and Cents per each. $ $ 26 10,700 LF Post-construction television inspection, for the sum of Dollars and Cents per linear foot. $ $ 27 1 LS For providing a pollution prevention system for stormwater discharge in accordance with the Specifications and the TCEQ regulations, and the assumption of the responsibility of said pollution prevention system, complete in place for the lump sum of Dollars and Cents. $ $ FAprojects\318\3200\Specs\Grav1ty Line\Part B_AD4.doc B-6 ATTACHMENT 1-AD4 318-3200 Lake Worth South Shore Gravity Sewer System Item Approx. Description of Items with Unit Extended No. Quantity Bid Prices Written In Words Price Amount Bid 28 13,000 LF Trench safety system for trench greater than 5 feet in depth, complete in place for the sum of Dollars and Cents per linear foot. $ TOTAL PROJECT BID: TOTAL AMOUNT BID FOR ITEMS (ITEMS 1-28) Dollars and Cents. $ CIT ,.. R\projects\318\3200\Specs\Grav4 Line\Part B AD4.doc B-7 EST 1 AD4 318-3200 Within ten days after notification by the City, the undersigned will execute the formal contract and will deliver an approved Surety Bond and such other bonds as required by the Contract Documents, for the faithful performance of the Contract. The attached bid security in the amount of (5 percent) of the total amount bid is to become the property of the City of Fort Worth,Texas,in the event the contract and bonds are not executed and delivered within the time set forth, as liquidated damages for the delay and additional work caused thereby. The undersigned bidder certifies that he has been furnished at least one set of the General Contract Documents and General Specifications for Water Department Projects,dated July 21,2000,and all addenda thereto, and that he has read and thoroughly understands all the requirements and conditions of those General Documents and the Specific Contract Documents and appurtenant plans. The undersigned assures that its employees and applicants for employment and those of any labor organization, subcontractors, and employment agency In either furnishing or referring employee applicants to the undersigned are not discriminated against as prohibited by the terms of City Ordinance No. 7278 as amended by City Ordinance No. 7400. The bidder agrees to begin construction within 10 calendar days after issue of the work order. Construction shall be finally complete within 210 calendar days of issuance of work order. (Complete A or B below, as applicable:) A. The principal place of business of our company is in the State of Non-resident Bidders in the State of , our principal place of business are required to be percent lower than resident Bidders by state law. A copy of the statute is attached. Non-resident Bidders in the State of , our principal place of business are not required to underbid resident Bidders. _ B. The principal place of business of our company or our parent company or majority holder is in the State of Texas. The bidder understands that the ENGINEER and OWNER will evaluate the qualifications of the bidder to perform the specified project and that, although obtaining pre-qualification from the Fort Worth Water Department is necessary to bid the project, it does not guarantee a favorable recommendation of award of a construction contract for this project. F:\projects\318\3200\Specs\Gravity Une\Part B_AD4.doc B-8 ATTACHMENT 1-AD4 318-3200 Receipt is hereby acknowledged of the following addenda to the Contract Documents: Addendum No. 1 dated Received Addendum No. 2 dated Received Addendum No. 3 dated Received Addendum No. 4 dated Received Addendum No. 5 dated Received Respectfully submitted, Attested by: Signage Signature Printed Name and Title Printed Name and Title Company Name Mailing Address Street Address City and State Telephone Number Seal and Authorization (If Corporation) FAprojects\318\3200\Specs\Gravity Line\Part B_AD4.doc B-9 ATTACHMENT 1-AD4 PART DA - ADDITIONAL SPECIAL CONDITIONS DA-1 AWARD OF CONTRACT FOR PROJECTS WITH MULTIPLE UNITS............ Omitted DA-2 PIPELINE REHABILITATION CURED-IN-PLACE PIPE..................................Omitted DA-3 PIPE ENLARGEMENT SYSTEM..................................................................... Omitted DA-4 FOLD AND FORM PIPE.................................................................................. Omitted DA-5 SLIPLINING..................................................................................................... Omitted - DA-6 PIPE INSTALLED BY OTHER THAN OPEN CUT........................................... Omitted DA-7 TYPE OF CASING PIPE................................HN...........•.................................. Omitted DA-8 SERVICE LINE POINT REPAIR 1 CLEANOUT REPAIR.................................. Omitted DA-9 PROTECTIVE MANHOLE COATING FOR CORROSION PROTECTION...................4 DA-10 MANHOLE REHABILITATION ........................................................................ Omitted DA-11 SURFACE PREPARATION FOR MANHOLE REHABILITATION.................... Omitted - DA-12 INTERIOR MANHOLE COATING -MICROSILICATE MORTAR SYSTEM..... Omitted DA-13 INTERIOR MANHOLE COATING -QUADEX SYSTEM.................................. Omitted DA-14 INTERIOR MANHOLE COATING -SPRAY WALL SYSTEM.......................... Omitted DA-15 INTERIOR MANHOLE COATING - RAVEN LINING SYSTEM....................................6 DA-16 INTERIOR MANHOLE COATING: PERMACAST SYSTEM WITH EPDXY LINER ............................................................................................................A........... Omitted �. DA-17 INTERIOR MANHOLE COATING-STRONG-SEAL-SYSTEM.......................... Omitted DA-18 RIGID FIBERGLASS MANHOLE LINERS....................................................... Omitted DA-19 PVC LINED CONCRETE WALL RECONSTRUCTION.................................... Omitted DA-20 PRESSURE GROUTING................................................................................. Omitted DA-21 VACUUM TESTING OF REHABILITATED MANHOLES................................. Omitted DA-22 FIBERGLASS MANHOLES.............................................................................Omitted DA-23 LOCATION AND EXPOSURE OF MANHOLES AND WATER VALVES......... Omitted DA-24 REPLACEMENT OF CONCRETE CURB AND GUTTER................................ Omitted DA-25 REPLACEMENT OF 6" CONCRETE DRIVEWAYS ........................................ Omitted DA-26 REPLACEMENT OF H.M.A.C. PAVEMENT AND BASE.............................................9 DA-27 GRADED CRUSHED STONES........................................................................ Omitted DA-28 WEDGE MILLING 2" TO 0" DEPTH 6.0'WIDE............................................... Omitted DA-29 BUTT JOINTS -MILLED.................................................................................Omitted DA-30 2" H.M.A.C. SURFACE COURSE (TYPE"D" MIX)......................................... Omitted DA-31 REPLACEMENT OF 7" CONCRETE VALLEY GUTTER ................................ Omitted DA-32 NEW 7" CONCRETE VALLEY GUTTER......................................................... Omitted DA-33 NEW 4" STANDARD WHEELCHAIR RAMP................................................... Omitted DA-34 8" PAVEMENT PULVERIZATION................................................................... Omitted DA-36 REINFORCED CONCRETE PAVEMENT OR BASE (UTILITY CUT) .............. Omitted DA-36 RAISED PAVEMENT MARKERS.................................................................... Omitted DA-37 POTENTIALLY PETROLEUM CONTAMINATED MATERIAL HANDLING ..... Omitted DA-38 LOADING, TRANSPORTATION,AND DISPOSAL OF CONTAMINATED SOIL................................................................................................................Omitted DA-39 ROCK RIPRAP -GROUT- FILTER FABRIC .................................................. Omitted DA-40 CONCRETE RIPRAP....................................................................................... Omitted DA-41 CONCRETE CYLINDER PIPE AND FITTINGS............................................... Omitted DA-42 CONCRETE PIPE FITTINGS AND SPECIALS................................................ Omitted DA-43 UNCLASSIFIED STREET EXCAVATION........................................................ Omitted DA-44 6" PERFORATED PIPE SUBDRAIN............................................................... Omitted DA-45 REPLACEMENT OF 4" CONCRETE SIDEWALKS......................................... Omitted DA-46 RECOMMENDED SEQUENCE OF CONSTRUCTION.................................... Omitted 06104103 ASC-1 Attachment 2 -AD4 PART DA - ADDITIONAL SPECIAL CONDITIONS DA-47 PAVEMENT REPAIR IN PARKING AREA....................................................... Omitted DA-48 EASEMENTS AND PERMITS..........................................................................Omitted DA-49 HIGHWAY REQUIREMENTS ..........................................................................Omitted DA-50 CONCRETE ENCASEMENT.......................................................................................9 DA-51 CONNECTION TO EXISTING STRUCTURES.................................................Omitted DA-52 TURBO METER WITH VAULT AND BYPASS INSTALLATION......................Omitted DA-53 OPEN FIRE LINE INSTALLATIONS................................................................ Omitted DA-54 WATER SAMPLE STATION............................................................................ Omitted DA-56 CURB ON CONCRETE PAVEMENT............................................................... Omitted DA-56 SHOP DRAWINGS.......................................................................................... Omitted DA-57 COST BREAKDOWN................................................................................................10 .. DA-58 STANDARD STREET SPECIFICATIONS H.M.A.C. OVERLAY....................... Omitted DA-59 H.M.A.C. MORE THAN 9 INCHES DEEP........................................................ Omitted DA-60 ASPHALT DRIVEWAY REPAIR....................................................................... Omitted DA-61 TOP SOIL........................................................................................................ Omitted DA-62 WATER METER AND METER BOX RELOCATION AND ADJUSTMENT....... Omitted DA-63 BID QUANTITIES ............................................................................................ Omitted DA-64 WORK IN HIGHWAY RIGHT OF WAY............................................................ Omitted DA-65 CRUSHED LIMESTONE (FLEX-BASE).......................................................... Omitted DA-66 OPTION TO RENEW........................................................................................ Omitted DA-67 NON-EXCLUSIVE CONTRACT....................................................................... Omitted DA-68 CONCRETE VALLEY GUTTER....................................................................... Omitted DA-69 TRAFFIC BUTTONS........................................................................................ Omitted DA-70 PAVEMENT STRIPING.................................................................................... Omitted DA-71 H.M.A.C. TESTING PROCEDURES................................................................ Omitted DA-72 SPECIFICATION REFERENCES ..............................................................................10 DA-73 RELOCATION OF SPRINKLER SYSTEM BACK-FLOW PREVENTERICONTROL VALVEAND BOX.....R..................................................................................... Omitted DA-74 RESILIENT-SEATED GATE VALVES ............................................................. Omitted DA-76 EMERGENCY SITUATION, JOB MOVE4N..................................................... Omitted -. DA-76 I %" & 2" COPPER SERVICES................................................................................10 DA-77 SCOPE OF WORK(UTIL. CUT)...................................................................... Omitted DA-78 CONTRACTOR'S RESPONSIBILTY(UTIL. CUT)........................................... Omitted DA-79 CONTRACT TIME (UTIL. CUT).......................................................................Omitted DA-80 REQUIRED CREW PERSONNEL& EQUIPMENT(UTIL. CUT) ..................... Omitted DA-81 TIME ALLOWED FOR UTILITY CUTS (UTIL.CUT)........................................ Omitted DA-82 LIQUIDATED DAMAGES (UTIL. CUT)............................................................ Omitted DA-83 PAVING REPAIR EDGES(UTIL. CUT)........................................................... Omitted DA-84 TRENCH BACKFILL (UTIL. CUT)................................................................... Omitted DA-86 CLEAN-UP (UTIL. CUT).................................................................................. Omitted DA-86 PROPERTY ACCESS (UTIL. CUT).................................................................. Omitted DA-87 SUBMISSION OF BIDS (UTIL. CUT)............................................................... Omitted DA-88 STANDARD BASE REPAIR FOR UNIT I (UTIL. CUT).................................... Omitted DA-89 CONCRETE BASE REPAIR FOR UNIT II & UNIT III (UTIL. CUT).................. Omitted DA-90 2"TO 9" H.M.A.C. PAVEMENT(UTIL. CUT)..................................................Omitted DA-91 ADJUST WATER VALVE BOXES, MANHOLES,AND VAULTS (UTIL. CUT) Omitted DA-92 MAINTENANCE BOND (UTIL. CUT)...............................................................Omitted DA-93 BRICK PAVEMENT(UTIL. CUT)..................................................................... Omitted 06/04/03 ASC-2 Attachment 2 - AD4 PART DA - ADDITIONAL SPECIAL CONDITIONS DA-94 LIME STABILIZED SUBGRADE (UTIL. CUT)................................................. Omitted DA-95 CEMENT STABILIZED SUBGRADE(UTIL. CUT)........................................... Omitted DA-96 REPAIR OF STORM DRAINI STRUCTURES(UTIL. CUT) ............................. Omitted DA-97 "QUICK-SET" CONCRETE (UTIL. CUT)......................................................... Omitted DA-98 UTILITY ADJUSTMENT(UTIL. CUT)..............................................................Omitted DA-99 STANDARD CONCRETE SIDEWALK AND WHEELCHAIR RAMPS (UTIL. CUT) ..U. *..........9.,.UN.........P......................................... . P.U.............. s..\......... Omitted DA-100 LIMITS QF CONCRETE PAVEMENT REPAIR(UTIL. CUT)........................ Omitted DA-101 CONCRETE CURB AND GUTTER(UTIL. CUT).......................................... Omitted ................... DA-102 PAYMENT (UTIL. CUT)............................................................................... Omitted DA-103 DEHQLES (MISC. EXT.)..............................................................................Omitted DA-104 CONSTRUCTION LIMITATIONS (MISC. EXT.)...........................................Omitted ................... DA-105 PRESSURE CLEANING AND TESTING (MISC. EXT.)............................... Omitted DA-106 BID QUANTITIES (MISC. EXT.) .................................................................. Omitted DA-107 LIFE OF CONTRACT(MISC. EXT.).............................................................Omitted DA-108 DETERMINATION AND INITIATION OF WORK (MISC. REPL.)................. Omitted DA-109 WORK ORDER COMPLETION TIME (MISC. REPL.)................................. Omitted DA-110 MOVE IN CHARGES (MISC. REPL.)........................................................... Omitted DA-111 PROJECT SIGNS (MISC. REPL.).................................F.............................. Omitted DA-112 LIQUIDATED DAMAGES (MISC. REPL.).................................................... Omitted DA-113 TRENCH SAFETY SYSTEM DESIGN (MISC. REPL.)................................. Omitted DA-114 FIELQ.pRi R .1.............................................................................................. Omitted 06104/03 ASC-3 Attachment 2 - AD4 PART DA - ADDITIONAL SPECIAL CONDITIONS DA-9 PROTECTIVE MANHOLE COATING FOR CORROSION PROTECTION A. GENERAL: 1. Scope: This section governs all work, materials and testing required for the application of interior protective coating. Structures designated to received interior coating are listed on the construction drawings. The structures are to be coated, including interior wall, top and bench surfaces. Protective coating for corrosion protection shall meet the requirements of this Specification (and items DA-14 and DA-15) and the Manufacturers recommendations and specifications. 2. Description: The Contractor shall be responsible for the furnishing of all labor, supervision, materials, equipment, and testing required for the completion of protective coating of structures in accordance with manufacturer's recommendations. 3. Manufacturer's Recommendations: Materials and procedures utilized for the lining process shall be in strict accordance with manufacturer's recommendations. 4. Corrosion Protection: Corrosion protection may be required on all structures where high turbulence or high H2S content is expected. B. MATERIALS: 1. Scope: This section governs the materials required for completion of protective coating of designated structures. 2. Protective Coating: The protective coating shall be a two-park epoxy resin system using 100% solids based epoxy binder with fibrous and flake fillers, as manufactured by Raven Lining systems and designated as Raven 405. 3. Specialty Cement (If required for leveling or filling): The specialty cement-based coating material shall be either Quadex QM-1 s as manufactured by Quadex, Inc. or Reliner MSP as manufactured by Standard Cement Materials, 4. Material Identification: The protective coating material sprayed onto the surface of the structure shall be a urethane or epoxy resin system formulated for the application to a sanitary sewer environment. The spray system shall exhibit the minimum physical properties as follows: Property Standard Long Terra Value Tensile Strength ASTM D-633 5,000 psi Flexural Stress ASTM D-790 10,000 psi Flexural Modulus ASTM D-790 550,000 psi 5. Mixing and Handling: Mixing and Handling of specialty cement material and protective coating material, which may be toxic under certain conditions shall be in accordance with the recommendations of the manufacturer and in such a manner 06104103 ASC-4 Attachment 2 - AD4 PART DA - ADDITIONAL SPECIAL CONDITIONS as to minimize hazard to personnel. It is the responsibility of the Contractor to provide appropriate protective measures to ensure that materials are under control at all times and are not available to unauthorized personnel or animals. All equipment shall be subject to the approval of the Engineer. Only personnel thoroughly familiar with the handling of the coating material shall perform the spray coating operations and coating installations. C. EXECUTION: 1. General: Protective coating shall not be installed until the structure is complete and in place. 2. Preliminary Repairs: a. All foreign materials shall be removed from the interior of the structure using high pressure water spray (3500 psi to 4000 psi at spray tip). b. All unsealed lifting holes, unsealed step holes, and voids larger than approximately one-half (1/2) inch in thickness shall be filled with patching compound as recommended by the material supplier for this application. C. After all repairs have been completed, remove all loose material. 3. Protective Coating: a. The protective coating shall be applied to the structure from the bottom of the frame to the bench, down to the top of the trough. The top of the structure shall also be coated. b. The protective coating shall be installed in accordance with the manufacturer's recommendations and the following procedure. 1) The surface shall be thoroughly cleaned of all foreign materials and matter. 2) Place covers over the invert to prevent extraneous material from entering the sewers. 3) If required for filling or leveling, apply specialty cement product to provide a smooth surface for the coasting material. 4) Spray the urethane or epoxy onto the structure wall and bench/trough to a minimum uniform thickness of 125 mils (0.125 inches). Thickness to be verifiable through the use of methods acceptable to the Engineer. After the walls are coated, the wooden bench covers shall be removed. 5) The final application shall have a minimum of three (3) hours cure time or be set hard to the touch, before being subjected to active flow. 06104103 ASC-5 Attachment 2- AD4 PART DA - ADDITIONAL SPECIAL CONDITIONS 6) No applications shall be made to frozen surfaces or if freezing is expected to occur inside the structure within 24 hours after application. 4. Testing of Rehabilitated Manholes: Testing of rehabilitated manholes for watertightness shall be performed by the Contractor after operations are complete in accordance with the Section D-36 - VACUUM TESTING OF SANITARY SEWER MANHOLES. D. MEASUREMENT AND PAYMENT: Payment shall be based on the Contract Unit Price Bid per vertical foot, measured from the bottom of the frame to the top of the bench. The Contract Unit Price shall be payment in full for performing the work and for furnishing all labor, supervision, materials, equipment and material testing required to complete the work. Pressure grouting, if necessary to stop active infiltration prior to application of the protective coating, shall be included in the above unit price. Grouting of the pipe seals, bench and trough, and lower portion of a particular structure, if required by the Engineer, shall be paid for separately, as specified in Section DA-1 Q, MANHOLE REHABILITATION. DA-15 INTERIOR MANHOLE COATING - RAVEN LINING SYSTEM A- GENERAL 1. Scope This section governs all work, materials and testing required for the application of interior manhole coating. Manholes designated for interior coating are listed of the Manhole Rehabilitation Schedule, listed in Section I. Interior manhole coating shall meet the requirements of this Section, or of Section DA-12, DA-13, DA-14, DA-16 or DA-17. 2. Description The Contractor shall be responsible for the furnishing of all labor, supervision, materials, equipment, and testing required for the completion of interior coating of manholes in accordance with the Contract Documents. 3. Manufacturer's Recommendations Materials, mixture ratios, and procedures utilized for the coating process shall be in accordance with manufacturer's recommendations. 4. Manholes - Manholes to be coated are of brick, block, or concrete construction. All manholes shall have a minimum of one-half (1/2) specialty cement-based coating material (Quadex QM-1s or Reliner MSP) sprayed or trowelled on coating over the original interior surface. 06104/03 ASC-6 Attachment 2-AD4 PART DA - ADDITIONAL SPECIAL CONDITIONS B. MATERIALS 1. Scope This section governs the materials required for completion of interior coating of manholes. 2. Interior Coating Raven Ultra High-Build epoxy Coating, a two-part epoxy resin system using 100% solids based epoxy binder with fibrous and flake fillers, is manufactured by Raven Lining systems and designated as Raven 405. 3. Specialty Cement The specialty cement-based coating material shall be either Quadex QM-1 s as manufactured by Quadex, Inc. or Reliner MSP as manufactured by Standard Cement Materials. 4. Material Identification Contractors will completely identify the types of grout, mortar, sealant, and/or root control chemicals proposed and provide case histories of successful use or defend the choice of grouting materials based on chemical and physical properties, ease of application, and expected performance. These grouting materials shall be compatible with Raven 405 interior coating. The contractor shall be responsible for getting approval from Raven Lining systems and/or the grout manufacturers for the use of these grouting materials. 5. Mixing and Handling Mixing and handling of interior coating, which may be toxic under certain conditions shall be in accordance with the recommendations of the manufacturer and in such a manner as to minimize hazard to personnel. It is the responsibility of the Contractor to provide appropriate protective measures to ensure that materials are under control at all times and are not available to unauthorized personnel or animals. All equipment shall be subject to the approval of the Engineer. Coating shall be performed only by certified applicators approved by the manufacturers. - C. EXECUTION 1. General Manhole coating shall not be performed until sealing of manhole from frame and grade adjustments, partial manhole replacement, manhole grouting or sewer replacement/repairs are complete. 2. Temperatures Normal interior coating operation shall be performed at temperatures of 40°F or greater. No application shall be made when freezing is expected within 24 hours. 08/04/03 ASC-7 Attachment 2 -AD4 PART DA - ADDITIONAL SPECIAL CONDITIONS 3. Interior Manhole Coating a. Manholes scheduled for interior coating are shown on the Manhole Rehabilitation Schedule. The interior coating shall be applied to the manhole from the bottom of the manhole frame to the benchttrough, including the bench/trough. b. The interior coating shall be installed in accordance with the manufacturer's recommendations and the following procedure. 1) The surface preparation shall comply with the requirements of Section DA-11, SURFACE PREPARATION FOR MANHOLE RESTORATION. 2) Apply a minimum of one-half (1/2) inch specialty cement-based product (Quadex QM-1s or Reliner MSP) smooth surface for the urethane coating material. 3) The surface prior to application may be damp but shall not have noticeable free water droplets seeping or running water. Material shall be spray applied per manufacturer's recommendations with a minimum thickness of 125 mils(0.125 inch). 4) After the walls are coated, the wooden bench covers shall be removed and the bench sprayed to the same average and minimum thickness as required for the walls. 5) The final application shall have a minimum of three (3) hours cure time or be set hard to the touch, before being subjected to active flow. 6) No applications shall be made to frozen surfaces or if freezing is expected to occur in side the manhole within 24 hours after application. 4. Testing of Rehabilitated Manholes a. After the epoxy liner has set (hard to touch), all visible pinholes shall be repaired. Repairs shall be made by lightly abrading the surface and brushing the lining material over the area. All blisters and evidence of uneven cover shall be repaired according to the manufacturer's recommendations. Spot check of coating thickness may be made by Owner's Representative, and the contractor shall repair these areas as required, at no additional cost to the Owner. b. Testing of rehabilitated manholes for watertightness shall be performed by the Contractor after operations are complete in accordance with Section DA- 21 A21 —VACUUM TESTING OF REHABILITATED MANHOLES. 0e104103 ASC-8 Atttachment,2-,.A4 PART DA - ADDITIONAL SPECIAL CONDITIONS D. MEASUREMENT AND PAYMENT Payment shall be based on the Contract Unit Price per vertical foot, measured from the bottom of the frame to the top of the bench. The Contract Unit Price shall be payment in full for performing the work and for furnishing all labor, supervision, materials, equipment all testing necessary to complete the work. Payment for grouting of pipe seals, bench and trough and manhole walls shall be based on the Contract Unit Price for each manhole actually grouted. DA-26 REPLACEMENT OF H.M.A.C. PAVEMENT AND BASE The contractor shall remove all existing deformed H.M.A.C. pavement and/or bad base material that shows surface deterioration and/or complete failure. The Engineer will identify these areas upon which time the contractor will begin work. The failed area shall be saw cut, or other similar means, out of the existing pavement in square or rectangular fashion, The side faces shall be cut -. vertically and all failed and loose material excavated. As a part of the excavation process, all unsatisfactory base material shall be removed, if required, to a depth sufficient to obtain stable sub-base. The total depth of excavation could range from a couple of inches to include the -- surface-base-some sub-base removal for which the Engineer will select the necessary depth. The remaining good material shall be leveled and uniformly made ready to accept the fill material. All excavated material shall be hauled off site, the same day as excavated, to a suitable dump site. After satisfactory completion of removal as outlined above, the contractor shall place the permanent pavement patch, with "Type D" surface mix. This item will always be used even if no base improvements are required. The proposed H.M.A.C. repair shall match the existing pavement section or the depth of the failed material, whichever is greater. However, the patch thickness shall be a minimum of 2 inches. Generally the existing H.M.A.C. pavement thickness will not exceed 6". Before the patch layers are applied, any loose material, mud and/or water shall be removed. A liquid asphalt tack coat shall be applied to all exposed surfaces. Placement of the surface mix lifts shall not exceed 3 inches with vibrator compactions to follow each lift. Compactions of the mix shall be to standard densities of the City of Fort Worth, made in preparation to accept the recycling process. All applicable provisions of Standard Specification Item Nos. 300 "Asphalts, Oils, and Emulsions", 304 "Prime Coat", and 312 "Hot-Mix Asphaltic Concrete" shall govern work. The unit price bid per cubic yard shall be full compensation for all materials, labor, equipment and incidentals necessary to complete the work. DA-50 CONCRETE ENCASEMENT Concrete encasement shall be Class E (1500 psi) concrete and for sewer line encasements shall conform to Fig. 113; for water line encasements it shall conform to Fig. 20 of the General Contract Documents. Requirements for such encasement are specified in Sections Et-20 and E2-20 of the General Contract Documents. Payment for work such as forming, placing, and finishing including all labor, tools, equipment and material necessary to complete the work shall be included in the linear foot price bid for Concrete Encasement. 06104103 ASC-9 Attachment 2 - AD4 PART DA - ADDITIONAL SPECIAL CONDITIONS DA-67 COST BREAKDOWN In order to establish a basis upon which partial payments to the Contractor may be authorized, immediately after execution of the contract the Contractor shall famish a detailed cost breakdown of his contract price arranged and itemized to meet the approval of the Engineer. DA-72 SPECIFICATION REFERENCES When reference is made in these specifications to a particular ASTM, AWWA, ANSI or other specification, it shall be understood that the latest revision of such specification, prior to the date of these general specifications or revisions thereof, shall apply. DA-76 1 %" & 2" COPPER SERVICES The following is an addendum to E1-17, Copper Water Service Lines and Copper Alloy Couplings: All fittings used for 1 '/x" and 2" water services lines shall be compression fittings of the type produced with an internal"gripper ring" as manufactured by the Ford Meter Box Co., Inc., Mueller Company, or approved equal. Approved equal products shall submit shop drawings and manufacturer's catalog information for approval. Contractor shall make all cuts to the copper tubing with a copper tubing cutter tool specifically designed for this purpose in order to provide a clean, square cut. The use of hacksaws or any other type of cutter will not be allowed. Prior to installing the compression fittings, the copper tubing will be made round by the use of a. "rounding tube" specifically made for that purpose. Payment for all work and materials associated with 1 '/a" and 2" copper services shall be included in the price of the appropriate bid item. 06104103 ASC-10 Attachment 2-AD4 ADDENDUM NO. 5 TO PLANS, SPECIFICATIONS,AND CONTRACT DOCUMENTS FOR CITY OF FORT WORTH n LAKE WORTH SOUTH SHORE GRAVITY SEWER SYSTEM WATER DEPARTMENT PROJECT NO. P171-070171131150 TO: PROSPECTIVE BIDDERS AND PLAN HOLDERS The Plans, Specifications and Contract Documents shall be modified as required by the following item: Item 5-1 Specifications,Part A—Notice to Bidders: Change Bid Date from"2:00 PM,October 2,2003 (Addendum 3)to "2:00 PM, February 5,2004". NoF ° �* �:*ter f I :*:........................._....r . MADELENE RAFALKO d .w*.........................y.....� Y ,d 90266 Q Oma;�... E N EO.•`,�`c,�' F _3 �ZI Ss/0 M A1.0% row %WwwnasOINWatalGroups%Bngineerin&afaikolActive Projects%Cwde Sewer\Conduction%Adverlis==Mddendum No 5.doc enc=um No. 5 —Page 1 of 1 316-3200 ADDENDUM NO. 6 TO PLANS, SPECIFICATIONS, AND CONTRACT DOCUMENTS FOR CITY OF FORT WORTH LAKE WORTH SOUTH SHORE GRAVITY SEWER SYSTEM TO: PROSPECTIVE BIDDERS AND PLAN HOLDERS The Plans, Specifications and Contract Documents shall be modified as required by the following items: Item 6-1 Addendum Item 5-1 Specifications, Part A— Notice to Bidders: Change Bid Date from "2:00 PM, February 5, 2004" to"2:00 PM, January 15, 2004". Item 6-2 Drawings, Sheet G-002: GENERAL NOTES: GENERAL CONSTRUCTION NOTE 2`. Add the following sentence: "THERE IS BURIED TELEPHONE LINE ALONG PIPELINE A NOT SHOWN ON THE DRAWINGS. THERE WILL BE SERVICE CONNECTIONS CROSSING THE PIPE TRENCH. CONTRACTOR TO LOCATE BURIED LINE PRIOR TO CONSTRUCTION, IDENTIFY ANY CONFLICTS WITH MAIN SEWER LINE AND BRING TO THE OWNER'S ATTENTION. OWNER MAY MODIFY SEWER ALIGNMENT AS NECESSARY TO AVOID RELOCATING TELEPHONE LINE. " All items in conflict with this addendum are hereby deleted. THIS ADDENDUM IS MADE PART OF THE SPECIFICATIONS AND CONTRACT DOCUMENTS, AND SHALL BE ACKNOWLEDGED ON THE PROPOSAL AND ON THE BID ENVELOPE. ALAN PLUMMER ASSOCIATES, INC. +" �Q,OF r�, P.. .. ....................... !./ J frey E. fey., ..•...P.E. i,. .EY.. CAFFEY j December 23, 2003 81896 cis1EAF�� i F:\projects\318\3200\Specs\Gravity Une\ADDENDUM_6.doc Addendum No. 6- Page 1 318-3200 CITY OF FORT WORTH, TEXAS SPECIFICATIONS AND CONTRACT DOCUMENTS FOR LAKE WORTH SOUTH SHORE GRAVITY SEWER SYSTEM TABLE OF CONTENTS Table of Contents PART A Notice to Bidders Special Instructions to Bidders PART B Proposal Minority and Women Business Enterprises Specifications (Including MWBE Ordinance) PART C General Conditions PART C1 Supplementary Conditions PART D Special Conditions PART E Technical Specifications 01001 - General Construction Requirements 01010 - Construction Sequence Items 01301 -Contractor's Submittals 02778 - Erosion Control Blankets PART F Bonds and Insurance PART G Contract APPENDIX A—STORM WATER POLLUTION PREVENTION PLAN APPENDIX B— PROJECT SIGN APPENDIX C - SOIL BORING LOGS F:\projects\318\3200\Specs\Gravity Line\TableofContents.doc I PART A NOTICE TO BIDDERS 318-3200 PART A- NOTICE TO BIDDERS Sealed proposals for the furnishing of all labor, materials, equipment and all necessary for construction of the Lake Worth South Shore Gravity Sewer System, Water Department Project Number P171-070171131150,addressed to Mr. Gary Jackson, City Manager of City of Fort Worth, Texas,will be received until 1:30 p.m.on the date of the bid opening,at the Office of the Purchasing Manager,City of Fort Worth, located in the lower level of the Municipal Building, 1000 Throckmorton Street, Fort Worth, Texas 76102. The bids will be publicly opened and read aloud in the City Council Chambers at: 2:00 PM, September 18, 2003 Special Contract Documents, including plans and detailed specifications, have been prepared for this project and may be obtained from the office of Alan Plummer Associates, Inc., 7524 Mosier View Court, Suite 200, Fort Worth, Texas 76118. One set of documents will be provided to prospective bidders on a non-refundable basis for thirty dollars($30). Additional sets may be purchased on a non-refundable basis for eighty dollars ($80) per set. General Contract Documents and Specifications for the Water Department projects,dated July 20, 2000, with the latest revisions, also comprise a part of the Special Contract Documents for this project and may be obtained by paying a non-refundable fee of fifty dollars($50)for each set,at the Engineering Service Division Office of the Fort Worth Water Department, 1000 Throckmorton Street, Fort Worth,Texas 76102. Pre-qualification according to the Fort Worth Water Department Special Instructions to Bidders is required. A pre-bid conference will be held at 10:00 a.m., September 9, 2003, at the Eagle Mountain Water Treatment Plant Conference Room, 6801 Bowman Roberts Road, Fort Worth, Texas 76179. All bidders must be pre-qualified with the City of Fort Worth Water Department a minimum of seven(7) days prior to the bid opening. The City reserves the right to reject any and all Bids and waive any and all irregularities. No bid may be withdrawn until the expiration of ninety(90) days from the date the Bids are received. For additional information, please contact Jeff Caffey at Alan Plummer Associates, Inc., at (817) 806-1700. Gary Jackson City Manager Gloria Pearson City Secretary Publication: August 21, 2003 August 28, 2003 P\projectsW 8132001Specs\Part A.doc A-1